F10R REFLECTIVE PHOTOCELL DETECTOR
INSTRUCTION MANUAL
COMFORT AND SECURITY
INSTALLATION
X
F10R Reective
photocell detector
PHOTOCELL DETECTOR FEATURES:
P04985 - Rev. 2
PRECAUTIONS
SPECIFICATIONS
- Max range: 08 meters (~26.25 feet)
- Operating voltage: 12Vdc - 24Vdc;
- Current drain: 80mA;
- NO and NC outputs;
- Immediate triggering;
- Pulsed output for PPA Control boards.
Round Reector
Connection terminal
( + ) ( - ): The device must be powered
by a 12Vdc - 24Vdc auxiliary power
supply;
P: Pulsed output for PPA Control
boards;
NA, C and NF: Relay dry contact
outputs. Used for circuit keying
when the photocell is used in
normal mode, either open or closed.
Step 1: Attach the photocell detector the same side the control
board is installed, since it will both receive commands from it and
power it up. The receiver is attached the opposite side, with the
transmitter and receiver facing each other. When attaching the
round reector, mind the (Installation) Position Indicator, it must
face up. ( ). The photocell detector must be attached so
that the opening for the wiring faces down, in order to
avoid accidental water entering.
A installation diagram can be seen on the previous page.
- Make sure the
wiring is facing down;
- Install the photocell
away from obstacles
which could block the
beam.
LED Indicator
Transmitter
Receiver
Wiring Position indicator
(for installation)
The height indicated by an “X” refers to the height of the
possible objects which will be detected by the device, such as
vehicles, people and pets. For example, for a 50cm (~1.65f) high
vehicle, the photocell detector must be installed over this
height, otherwise it will not detect the vehicle. One must
observe the minimum height (30 cm - ~0.99f), in order to both
ensure a proper operation and avoid false alarms.
Note: There is no maximum height for installing the photocell
detector.
Step 2: Set the operation mode according to the
following procedures :
'Coded PPA' Mode:
NO (Normally Open) Mode:
NC (Normally Closed) Mode:
LED indicator on: Misaligned
or blocked sensor.
LED indicator off: optimal alignment.
LED indicator blinking: Function used for
installation; the blinking LED indicates
to the installer that the photocell detector
is sending the signal to the control board and
it is operating, but it is partially aligned, and
only needs a simple adjustment for optimal
alignment and proper operation.
NOTE: The slower the LED blinks, the closer to
the optimal alignment the photocell detector is;
if the LED starts blinking faster, it is less aligned.
'P' output of the photocell's connection terminal
connected to the 'FOT' output of the control board
'NA', 'C' and 'NF' outputs of the connection terminal
not connected.
'NF' output of the photocell's connection terminal
connected to the 'FOT output of the control board
'C' output of the photocell's connection terminal
connected to the ( - ) output of the control board.
'NA' output of the photocell's connection terminal
connected to the 'FOT' output of the control board
'C' output of the photocell's connection terminal
connected to the ( - ) output of the control board.
LED FUNCTIONS
F10R REFLECTIVE PHOTOCELL DETECTOR
INSTRUCTION MANUAL
Step 1: Attach the photocell detector the same side the control
board is installed, since it will both receive commands from it and
power it up. The receiver is attached the opposite side, with the
transmitter and receiver facing each other. When attaching the
round reector, mind the (Installation) Position Indicator, it must
face up. ( ). The photocell detector must be attached so
that the opening for the wiring faces down, in order to
avoid accidental water entering.
A installation diagram can be seen on the previous page.
STEP 3: Connect power to the
sensor by using an auxiliary power
supply, such as the control board.
Observe the polarity, the wires
must be connected to the auxiliary
power supply according to the
diagrams of the connection
terminal .
The height indicated by an “X” refers to the height of the
possible objects which will be detected by the device, such as
vehicles, people and pets. For example, for a 50cm (~1.65f) high
vehicle, the photocell detector must be installed over this
height, otherwise it will not detect the vehicle. One must
observe the minimum height (30 cm - ~0.99f), in order to both
ensure a proper operation and avoid false alarms.
Note: There is no maximum height for installing the photocell
detector.
ATIV/PASS Jumper: This jumper changes the relay operation
mode.
- Closed: Passive relay (Factory default setting).
- Open: Active relay (In this mode, the relay keeps activated
while the photocell detector is aligned, i.e., NO mode becomes
NC and vice versa).
COMFORT AND SECURITY

Other PPA Security Sensor manuals

PPA SENSOR SMART SLIM PET User manual

PPA

PPA SENSOR SMART SLIM PET User manual

PPA BOTOEIRA TOUCH PVC User manual

PPA

PPA BOTOEIRA TOUCH PVC User manual

Popular Security Sensor manuals by other brands

Respirex GLS 300 A User instructions

Respirex

Respirex GLS 300 A User instructions

EINHELL TC-MD 50 Original operating instructions

EINHELL

EINHELL TC-MD 50 Original operating instructions

Korno GT-1000 SERIES user manual

Korno

Korno GT-1000 SERIES user manual

DMP Electronics 1129 WIRELESS GLASSBREAK DETECTOR installation guide

DMP Electronics

DMP Electronics 1129 WIRELESS GLASSBREAK DETECTOR installation guide

Radiodetection RD8100 Operation manual

Radiodetection

Radiodetection RD8100 Operation manual

VOSS.farming FS10 instruction manual

VOSS.farming

VOSS.farming FS10 instruction manual

PCE Health and Fitness PCE-186 CB user manual

PCE Health and Fitness

PCE Health and Fitness PCE-186 CB user manual

Honeywell ADEMCO 5808EU installation instructions

Honeywell

Honeywell ADEMCO 5808EU installation instructions

HP 423A Operating note

HP

HP 423A Operating note

Hyundai WS SENZOR 2061 user manual

Hyundai

Hyundai WS SENZOR 2061 user manual

MICRO-EPSILON capaNCDT 6228 operating instructions

MICRO-EPSILON

MICRO-EPSILON capaNCDT 6228 operating instructions

Takex PIR-T15WE(W) instruction manual

Takex

Takex PIR-T15WE(W) instruction manual

Centsys FLUX SA installation manual

Centsys

Centsys FLUX SA installation manual

Lechange WP1 Series quick start guide

Lechange

Lechange WP1 Series quick start guide

Crowcon Xgard IR Installation, operating and maintenance instructions

Crowcon

Crowcon Xgard IR Installation, operating and maintenance instructions

B.E.G. LUXOMAT PD4-S-DAA4G Installation and operating instruction

B.E.G.

B.E.G. LUXOMAT PD4-S-DAA4G Installation and operating instruction

Inficon HLD6000 Translation of the original operating instructions

Inficon

Inficon HLD6000 Translation of the original operating instructions

Bentel Security ZT100H quick start guide

Bentel Security

Bentel Security ZT100H quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.