GENERAL INSTRUCTIONS
ELECTRICAL SPECIFICATIONS
DIMENSIONS
Voltage
(V) Phases Freq.
(Hz)
Power
(kW) Circuit
(A)
Consum.
(kWh) Cable Socket
Rocket
Express
32A
(2P+T)
208/240 5.7 30
Single 60 3x10AWG NEMA 6-30
4
USA
5.7 30
Single 60 3x10AWG NEMA 6-30
4
Canada
230 7.2 32
Single 50 5
Europe
220 6.3 32
Single 60 3x4mm²
4.4
Brazil
220 6.3 32
Single 60 4.4
Latin
America 60Hz
32A
(2P+T)
32A
(2P+T)
3x4mm²
3x4mm²
230 7.2 32
Single 50 5
Latin
America 50Hz
32A
(2P+T)
3x4mm²
Rocket Express
Speed Oven
Product dimencions Packing dimensions
Capacity
Rocket
Express
Chamber
Dimensions
Height Width
5 ¾"
146mm
Depth
14 ¼"
362mm
15 ½"
394mm
Height Width Depth Weight Width Depth Weight
194lbs
88kg
242lb
110kg
25 ³⁄"
644mm
21"
532mm 31 ³⁄"
805mm
31 ¹⁄"
800mm
22"
560mm 33 ⁷⁄"
860mm
Height
Ensure that the electrical characteristics of the building network
are in accordance with the technical specifications printed on the
data badge located on the rear panel of the unit. The receptacle
should be located no more than 5ft /1.5m away from the unit.
This unit must be properly grounded to avoid electrical shock. This
unit is equipped with a 3-prong plug. This plug must be connected
to a properly installed and grounded outlet. The building electrical
characteristics are the customer's responsibility.
PRODUCT DIMENSIONS
27 ⁄"
(700 mm)
11 ⁄"
(294 mm)
40"
(1015 mm)
1 ⁄"
(38 mm)
1 ⁄"
(38 mm)
3"
(75 mm)
30 ⁄"
(767 mm)
21 ⁄"
(546 mm)
4"
(100 mm)
21"
(532 mm)
21 ⁄"
(544 mm)
25 ⁄"
(644 mm)
17 ⁄"
(435 mm)
3"
(76 mm)
INSTALLATION
Exhaust
Outlets
Power
Cable
5 ft
(1.5m)
Maximum
Distance
Receptacle
Air Inlet
The oven must be installed on a base or counter that supports the
weight of the unit (approximately 194 lbs. / 88 kg)
For proper ventilation, a minimum space of 3" (76mm) between the
rear of the oven and the wall is required.
Do not block the air inlets and exhaust outlets located on the bottom
and rear of the oven.
It is not recommended for the unit to be positioned near stoves,
deep fryers, hot plates and other equipment that releases fat, fumes
and heat.
The oven must be installed at a leveled and ventilated location.
Improper installation may void the equipment warranty.
Wall
Clearance
Back
3"
76mm
Right SideLeft Side
0.74 cu.ft
21L
0"
0mm
0"
0mm
208/240