Contents
(English Version)
I. Disclaimers, Exclusions and Limitations
of Liability pg. 04
II. About this book pg. 05
III. About your Presidium Gem Computer
Gauge pg. 06
IV. IMPORTANT NOTICE pg. 10
1. GETTING STARTED with your Presidium
Gem Computer Gauge pg. 12
2. PERFORMING A TEST with your
Presidium Gem Computer Gauge pg. 13
a. Measurement
b. Weight Estimator
c. S.G. Dictionary
d. Gemstone Estimator
e. Calculator
f. Inventory
g. PC connectivity
3. READING TEST RESULTS with your
Presidium Gem Computer Gauge pg. 32
4. TAKING CARE of your Presidium Gem
Computer Gauge pg. 34

4
PLEASE READ AND NOTE PRESIDIUM WARRANTY
TERMS AND CONDITIONS as stated in the warranty
card. Presidium warranty for its testers are subject to
proper use by its users in accordance with all the terms
and conditions as stated in the relevant user handbook
and shall cover only manufacturing defects.
Due to continuous product improvement, Presidium
reserves the right to revise all documents including the
right to make changes to the handbook without notice
and without obligation to notify any person of such
revisions or changes. Users are advised to check
Presidium’s website http://www.presidium.com.sg/ from
time to time.
Presidium shall not be responsible for any damage or
loss resulting from the use of this gauge or handbook,
and under no circumstances shall Presidium, its
manufacturer or any of its subsidiaries, licensors,
distributors, resellers, servants and/or agents be liable for
any direct or indirect damages, resulting from the use of
this gauge.
TO THE MAXIMUM EXTENT PERMITTED BY
APPLICABLE LAW, under no circumstances shall
Presidium, its manufacturer or any of its subsidiaries,
licensors, distributors, resellers, servants and/or agents
be responsible for any special, incidental, consequential
or indirect damages howsoever caused.
The gauge or Presidium Gem Computer Gauge (PGCG)
referred to in this handbook is provided and/or sold on
an “as is” basis. Except as required by applicable law,
no warranties of any kind, either expressed or implied,
including, but not limited to, the implied warranties of
merchantability and tness for a particular purpose.
I. Disclaimers, Exclusions and Limitations of
Liability

5
II. About this book
Thank you for purchasing the Presidium Gem Computer
Gauge (“PGCG” or “gauge”).
This handbook is designed to help you set up your gauge
and describes all you need to know about how to use
your gauge accurately and take care of it in line with its
requirements. Please read these instructions carefully
and keep them handy for future reference.
This book also contains the terms and conditions in
relation to the use of the gauge including the
Disclaimer, Exclusion and Limitation of Liability
clauses stated above in Section I.

6
The Presidium Gem Computer Gauge has been
developed as an extension to the existing Presidium
Electronic Gemstone Gauge with additional features to
perform more functions, including:
• Measures actual gemstone dimensions and
estimates gemstone weight and identity
• Measures 74 gemstones and 9 different shapes
• Accurate measurement up to 0.01mm
• Direct carat conversion for round brilliant cut
diamonds
• Clear and visible display for ease of reading
measurements
• Light and portable instrument that can be used
anywhere
• PC connectivity for ease of importing and printing
measurement results
Product specications:
Measurement range: 0.00mm to 25.00mm or 0.000ct to
57.343ct
Recommended battery: CR 2450 3V or equivalent
Battery lifespan: generally about 26 hours of continuous
usage
Included in your package:
• Presidium Gem Computer Gauge
• CR-2450 3V battery
• High setting jewelry attachment
• Mini CD ROM
• USB Cable
• User handbook
• Warranty card
• Protective box
IIl. About your Presidium Gem Computer Gauge

7
1 LCD Display
2Base Anvil
3Wedge-shaped Points
4 Slider
5 Slider Platform
6 Protruding Probe
7Jewelry Attachment
8 Battery Compartment
9 USB Cable
10 USB Port
11 Selection Keypad
12 Mode Button
13 Clear Button
14 Enter Button
15 Navigation Button
16 Calculator Activation Button
17 Unit Conversion Button
Gauge parts

8
Display Conguration
The LCD display of PGCG is generally divided into three
sections.
1. Interactive display
2. Scroll bar
3. Instruction bar
Keypad Conguration
Please refer to table below for the function of each key
on the selection keypad. Some keys will have more than
one function.
Front View

9
Name Normal Function Additional
Function
1 Carat
mm
Press to change
measurement unit
between millimeter
(mm) and carat (Ct)
In “Weight
Estimator” and
“Stone
Estimator”
mode, press
to toggle
between
“Measure-
ment” and
“Keypad” to
input
dimension
2 Mode Press to display the
function selection
menu
3 Cancel Press to delete
items
• Press to
turn on
PGCG
• In ‘Mea
surement”
mode,
press
for tare/
zero
function
4 Calcula-
tor
Press to activate
calculator mode
In “Weight
Estimator”
mode, press
for price
calculation
5 Enter Press to conrm
selection
6 Naviga-
tion
keypad
Press to navigate
data in interactive
display

10
• Keep the gauge dry. Precipitation and all types of
liquids or moisture can contain minerals that will
corrode electronic circuits. If your tester does get wet,
remove the battery, and allow the tester to dry
completely before replacing it.
• Do not use, store or expose the gauge in dusty and
dirty areas. Its moving parts and electronic
components can be damaged.
• Do not use, store or expose the gauge in hot areas.
High temperatures can damage or shorten the life of
tester, damage batteries, and warp or melt certain
plastics.
• Do not use, store or expose the gauge in cold areas.
When the tester returns to its normal temperature,
moisture can form inside the tester and damage
electronic circuit boards.
• Do not attempt to open the gauge other than as
instructed in this handbook.
• Do not drop, knock, or shake the gauge. Rough
handling might break internal circuit boards and ne
mechanics.
• Do not use harsh chemicals, cleaning solvents, or
strong detergents to clean the gauge.
• Do not paint the gauge. Paint can clog the moving
parts and prevent proper operation.
IV. IMPORTANT NOTICE

11
If the gauge is not working properly, kindly contact
sg or:
Presidium Instruments Pte Ltd
No. 6 Penjuru Lane
Singapore 609187
Singapore
(65) 6379 5000
Attn: Customer Service Executive

12
1. Pull the battery slider sideway outward using either
ngernail or screw driver.
2. Place a CR 2450 3V battery with the (+) sign facing
upward in the battery compartment and close by
pushing the battery slider sideway inward.
3. The use of alkaline batteries is preferred, as it should
generally give approximately two and a half hours of
continuous operation, while the use of ordinary
batteries will give a shorter working life.
Turning on your Presidium Gem Computer Gauge
1. Press the “C” button on the selection keypad.
2. The word “Presidium” will appear and the device will
automatically go to “Measurement” mode.
3. The screen will display two lines; the rst being
measurement in millimeter unit and the second line
being measurement in carat unit.
Please note that the PGCG will automatically shut down
after 5 minutes of inactivity.
Battery information
Do not leave worn out batteries in the battery
compartment as the batteries may corrode, leak or
damage the gauge. Batteries should be removed when
the instrument is expected to be stored for an extended
period of time.
1. GETTING STARTED with your Presidium Gem
Computer Gauge
Inserting a battery into your Presidium Gem
Computer Gauge

13
1. By default, upon power up, the device will be in
“Measurement” mode.
2. PGCG comes with the following functions:
a) Measurement
b) Weight Estimator
c) S.G. Dictionary
d) Gemstone Estimator
e) Calculator
f) Inventory
g) PC connectivity
3. To use other functions, press “Mode” on the
selection keypad and choose a function from the
list.
a. Measurement
2. PERFORMING A TEST with your Presidium Gem
Computer Gauge
Requirement Activation Key Display
1 Upon turning on,
PGCG will dis-
play dimension in
mm and weight in
Carat:
1. Press “C” to
turn on
0.00 mm
0.000 ct
2 For display of
dimension in mm
only:
1. Press “Ct/
mm”
0.00 mm
3 For display of
weight in Carat
only:
1. Press “Ct/
mm”
0.000 ct

14
• The Presidium Gem Computer Gauge should be held
in the palm of either hand. Control the slider with the
thumb.
• When measuring loose stones, pull the Slider and
place the stone on the Slider platform. The base of
the stone should be parallel to the platform to prevent
it from moving.
• When measuring mounted stones, insert the jewelry
attachment to the gauge and place the stone
between the jewelry attachment and slider anvil.

15
• Press “ct/mm” to alternate between the following
displays:
1. Display of both dimension in mm and weight in
carat (by default)
2. Display of dimension in mm only
3. Display of weight in carat only
The default setting of Presidium Gem Computer
Gauge (PGCG) is programmed for American
Standard Round Brilliant Cut
For other gemstones of other shapes, please
directly proceed to the following steps.
b. Weight Estimator
Presidium Gem Computer Gauge (PGCG) estimates the
weight of the gemstone from the shape, diameter, depth
and nature of the gemstone.
The different shapes of gemstones as shown in diagram
below:
• Slowly close the Slider. The reading will be displayed
on the window immediately.

16
Requirement Activation
Key
Display
1. Select Weight
Estimator:
Select Mode
Scroll to Weight
Estimator
Press “ENT” to
conrm
2. Select New or
Previous Set
ting:
Scroll to select
Press “ENT” to
conrm
[SELECT SETTING]
New Setting
Previous Setting
Round
Marquise
Cushion
Oval
Heart
Square
Emerald
Pear
Cabochon
[MODE]
Measurement
Weight Estimator
S.G. Dictionary

17
3.1 New Settings
Select Gem
stone name:
Scroll to select
gemstone
name by the
rst alphabet.
Press “ENT” to
conrm
Select a Gem
stone:
Scroll to select
Press “ENT” to
conrm
Select a Shape:
Scroll to select
Press “ENT” to
conrm
Note: The different
dimensions to be
input depend on
the shape of the
gemstone. Please
refer to Page 16
for shape and
their respec-
tive dimensions
required.
3.2 Previous Settings
Setting of previ-
ous gemstone will
be displayed:
• Press “ENT”
to conrm
[SELECT NAME]
A B C D E F
G H I J K L
M N O P Q R
[SELECT STONE]
Diamond
Danburite
Diopside
[SELECT SHAPE]
Round
Oval
Emerald
[PREV. SETTING]
Diamond
Round

18
4 Select method
of measure
ment:
Scroll to select
from measure
ment or keypad
Press “ENT” to
conrm
4.1 Measurement
Measurement of
Diameter:
• Place gem
stone’s
diameter on
base anvil
• Press “ENT”
to conrm
Measurement of
Depth:
1. Place gem
stone’s depth
on base anvil
2. Press “ENT”
to conrm
4.2 Keypad
Keying of
Diameter:
Key in gem
stone’s
diameter
To conrm
entry,
navigate
cursor to
and press
“ENT”
[SELECT INPUT]
Measurement
Keypad
[MEASURE]
0 1 2 3 4 5
6 7 8 9 .
Dep.= 3.11 mm
CT/MM
[MEASURE]
0 1 2 3 4 5
6 7 8 9 .
Dia .= 4.55 mm
CT/MM
[KEY IN]
0 1 2 3 4 5
6 7 8 9 .
Dia .= 4.55 mm
CT/MM

19
Keying of
Depth:
Key in gem
stone’s depth
To conrm
entry,
navigate
cursor to
and press
“ENT”
Please note that
at any point,
pressing Ct/mm
will toggle
between
“Keypad” or
“Measurement”
input methods
5. Summary of gem-
stone’s diameter
and depth.
• Press “ENT” to
conrm
6. Estimated weight
of gemstone will
be displayed. At
this point, user
can either press
“Ent” to store or
“Cal” for price
calculation.
Details will be
given in 6.1 and
6.2 below
[KEY IN]
0 12 3 4 5
6 7 8 9 .
Dep.= 3.11 mm
CT/MM
[SUMMARY P1]
Dia . = 4.55 mm
Dep. = 3.11 mm
[SUMMARY P2]
Diamond
Round
weight = 0.299 ct
CAL

20
6.1 Storing Data
Storing of data
into inventory:
Press “ENT” to
store data
Scroll to select
“YES/NO”
If user selects
“NO”, display
will return to
“Select Setting”
for next
measurement.
User will have
the liberty to
choose
between
previous or
new
stones setting.
Press “ENT” to
conrm
[SAVE STONE?]
No
Yes
[SELECT SETTING]
New Setting
Previous Setting
Table of contents
Languages:
Other PRESIDIUM Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Tektronix
Tektronix VM700T Programmer's manual

Hioki
Hioki 3293-50 instruction manual

Leica
Leica TCR307 quick start guide

Keysight Technologies
Keysight Technologies X Series Custom Installation Notes

PCE Instruments
PCE Instruments PCE-AM 45 user manual

BRONKHORST
BRONKHORST Mini CORI-FLOW MI Series instruction manual

Parker Balston
Parker Balston GC-4000 Installation, operation and maintenance manual

NOMIS Seismographs
NOMIS Seismographs Mini-SuperGraph II user guide

Endress+Hauser
Endress+Hauser Prothermo NMT 539 operating instructions

Lufft
Lufft CHM 15k user manual

STAUFF
STAUFF LPM-II-plus manual

R&S
R&S NRPM user manual