Thermostat Quick Reference
The low battery indicator is displayed when the AA battery power is low. If the user
fails to replace the battery within 21 days, the screen will only show the low battery
indicator but maintain all functionality. If the user fails to replace the batteries after
an additional 21 days (days 22-42 since rst“low battery” display) the setpoints will
change to 55˚F (Heating) and 85˚F (Cooling). If the user adjusts the setpoint away from
either of these, it will hold for 4 hours then return to either 55˚F or 85˚F. After day 63
the batteries must be replaced immediately to avoid freezing or overheating because
the thermostat will shut the unit o until the batteries are changed.
Important
Indicates the current room temperature
Time and day of the week
Setpoint: Displays the user selectable setpoint temperature.
Hold is displayed when the thermostat program is permanently overridden.
System Operation Indicators:
The COOL ON, HEAT ON or icon will display when the COOL, HEAT, or (fan) is on.
1
2
3
7
8
Low Battery Indicator: Replace batteries when this indicator is shown.
Button Options
Program Time Periods: This thermostat has 4 programmable time periods
per day.
7
3
2
2
1
8
Getting to know your thermostat
Wiring
Private Label Badge
Hold
LOW
COOL ON
HEAT ON
Sun Mon Tue Wed Thu Fri Sat
Temperature
Tech Set
Next Step
Set Time
Run Sched
Set Sched
Hold
Prev Step
Menu
Done LEAVE SLEEP
RETURN WAKE
Wiring Tips
RH & RC Terminals
For single transformer systems, leave the
jumper wire in place between RH and RC.
Remove jumper wire for two transformer
systems.
Heat Pump Systems
If wiring to a heat pump, use a small
piece of wire (not supplied) to connect
terminals W and Y.
(With NO AUX or
Emergency Heat)
C Terminal
The C (common wire) terminal does
not have to be connected when the
thermostat is powered by batteries.
Wire Specications
Use shielded or non-shielded
18-22 gauge thermostat wire.
Caution:
Electrical Hazard
All components of the control
system and the thermostat
installation must conform to
Class II circuits per the NEC Code.
Warning:
Installation Tip: Do not overtighten terminal block screws, as this
can damage the terminal block. A damaged terminal block can
keep the thermostat from tting on the subbase correctly or cause
system operation issues. Max Torque = 6in-lbs.
Wiring
If you are replacing a thermostat,
make note of the terminal
connections on the thermostat
that is being replaced. In some
cases the wiring connections will
not be color coded. For example,
the green wire may not be
connected to the Gterminal.
Loosen the terminal block
screws. Insert wires then
retighten terminal block screws.
Place nonammable insulation
into wall opening to prevent
drafts.
1.
2.
3.
Failure to disconnect the power
before beginning to install this
product can cause electrical shock
or equipment damage.
Terminal Designations
C
OHeat pump changeover valve
energized in cooling
Heat pump changeover valve
energized in heating
WHeat relay
RH Transformer power for heating
RC Transformer power for cooling
GFan relay
YCompressor relay
B
Common wire from secondary side of
cooling system transformer
Features
Temporary and Permanent Hold Feature
When cool or heat is turned on, the thermostat will display HOLD
and RUN SCHED on the left of your screen when you press the
or button.
Temporary Hold: At this time if you do nothing, the temperature will
remain at this setpoint temporarily until next time period.
Permanent Hold: If you press the HOLD key on the left of your
screen, you will see HOLD appear below the setpoint temperature in
the display. The thermostat will now permanently stay at this
setpoint and can be adjusted using the or keys.
To Return to Running Schedule: Press the RUN SCHED button on
the left of your screen to exit either temporary or permanent hold.
Filter Change Reminder
If your installing contractor has congured the thermostat to remind
you when the air lter needs to be changed, you will see FILT in the
display when your air lter needs to be changed.
Resetting the lter change reminder: When FILT reminder is
displayed, you should change your air lter and reset the reminder
by holding down the second button from the top left side of the
thermostat for 3 seconds.
(If using programming)
FAN
ON AUTO
SYSTEM
COOL OFF HEAT
Hold down 3 seconds,
to reset lter reminder.
Gently slide a screwdriver into the
bottom edge of the badge. Gently turn
the screwdriver counter clockwise. The
badge is held on by a magnet in the well
of the battery door. The badge should pry
o easily. DO NOT USE FORCE.
About The Badge
All of our thermostats use the same universal magnetic badge. Visit the
company website to learn more about our free private label program.
Magnet in door
Use the bevel on lower ridge