P a g e | 7
Operation
WIRED ROCKER
If using the wired rocker, press and hold either the up or down key of the desired direction of travel to move the actuators.
Release the rocker when the desired position of the actuators is reached.
TROUBLESHOOTING/LEARN MODE
Reset Mode
Use the reset mode to clear failure modes after they have been identified and handled. The reset mode will retract all
actuators, so they align after a scenario occurs which forces them to misalign. Only use this reset function if the below
happens:
1. All actuators have stopped on their own and the control box is beeping continuously.
2. The actuators have become misaligned in any way from each other without the intervention of the control box. For
example, one actuator retracts slightly over a long period of time without action from the control box.
Warning: It is best if the actuators are reset while completely uninstalled from the application. During reset, the
actuators are not operated synchronously.
The steps to initiate the reset procedure are described below:
1. Disconnect power to the control box.
2. Install the included rocker switch if it was not already installed before.
3. This step will retract the actuators. Hold down the Up direction of the rocker. While holding the rocker direction, plug
back the power to the control box.
4. Allow the actuators to fully retract.
If any actuator is not moving and all connections are verified, contact Progressive Automations directly for further
troubleshooting.
5. Once the actuators have fully retracted, a single beep should be heard from the control box to confirm the reset was
successful. Resume normal use of the actuators.
If no single beep was heard, disconnect the power from the control box and contact Progressive Automations directly for
further troubleshooting.