ProMinent ProMix S User manual

ProMinent ProMix ‘S & C’ Polymer Feeder
ProMix Series S&C User Manual
Operating Instructions
ProMinent® ProMix-S & C
Polymer Blending Systems
Please completely read through these operating instructions first! Do not discard!
The warranty shall be invalidated by damage caused by operating errors!
ProMix_S&C_IOM (02/26/2020): –P/N: 984704-(Rev-E)
ProMinent Fluid Controls, Inc. (USA) 136 Industry Drive, Pittsburgh, PA 15275
Tel: (412) 787-2484 www.prominent.us Fax: (412) 787-0704

ProMinent ProMix ‘S & C’ Polymer Feeder
ProMix Series S&C User Manual
Table of Contents
i. Overview: ...............................................................................................................................................4
ii. ProMix S Systems with Peristaltic Pumps:.............................................................................................5
ii. ProMix S Systems with Diaphragm Pumps:........................................................................................... 6
ii. ProMix C Systems with Peristaltic Pumps:............................................................................................7
ii. ProMix C Systems with Diaphragm Pumps:..........................................................................................8
iii. Peristaltic Polymer Pumps used on S & C Models: ...............................................................................9
iv. Diaphragm Polymer Pumps used on S & C Models:............................................................................10
1.0 INSTALLATION & QUICK START GUIDE.........................................................................................11
1.1 Safety:............................................................................................................................................11
1.2 Delivery & Storage Checklist:.........................................................................................................11
1.3 Installation Considerations: ............................................................................................................11
1.4 Installation:.....................................................................................................................................12
1.5 Quick Start Guide:..........................................................................................................................13
1.6 ProMix Options for Polymer Settings and Controller Door Switches..............................................14
1.7 Servicing Guidelines:......................................................................................................................15
2.0 CONTROLLER..................................................................................................................................16
2.1 Keypad Navigation......................................................................................................................... 16
2.2 Main Menu.....................................................................................................................................17
2.3 Adjust Setpoint............................................................................................................................... 18
2.4 Modify Timing.................................................................................................................................19
2.5 Manually Flush Mixer.....................................................................................................................22
2.6 Automatic Flush Mixer.................................................................................................................... 22
2.7 Status Message Summary..............................................................................................................24
2.8 Calibrate 4-20mA Input................................................................................................................... 25
2.9 Scale the 4-20mA Input..................................................................................................................26
2.9 Scale the 4-20mA Input (continued) ...............................................................................................27
2.10 Response on Loss of 4-20 mA Input.............................................................................................28
2.11 Calibrate 4-20mA Output..............................................................................................................29
2.12 Operation Configuration...............................................................................................................30
2.13 Feed Verification.......................................................................................................................... 31

ProMinent ProMix ‘S & C’ Polymer Feeder
ProMix Series S&C User Manual
2.15 4-20mA Controls.......................................................................................................................... 32
2.16 TroubleshootingGuide................................................................................................................. 32
2.17 Diagnostic Display........................................................................................................................33
2.18 Blue White A-100NV Pump..........................................................................................................34
3.0 SPARE PARTS & PREVENTIVE MAINTENANCE............................................................................35
3.1 BLUE WHITE A-100NV Pump Spare Parts.................................................................................... 35
3.2 GAMMA XL Pump Spare Parts......................................................................................................35
3.3 PVC Mixing Chamber Spare Parts ................................................................................................. 36
3.4 Piping ComponentsSpare Parts.....................................................................................................36
3.5 Control Panel Spare Parts..............................................................................................................36
3.6 Maintenance and Lubrication Schedule..........................................................................................31
Appendix A - TA Series Bill of Material....................................................................................................30
Appendix B –Control Panel “A Controls”.................................................................................................48
B.2 Control Panel Drawings.................................................................................................................50
B.3 4-20 mA Input Scaling....................................................................................................................56
Appendix C –Polymer Sizing /
Dosage
....................................................................................................57
Appendix D –Reference Documents.......................................................................................................58
Appendix E - Keypad Menu Overview.....................................................................................................59

ProMinent ProMix ‘S & C’ Polymer Feeder
ProMix Series S&C User Manual
i. Overview:
The ProMix S & C “TA Series” Polymer Feeder is a skid system designed to control feed water and polymer and
combine them to produce a high quality solution. The system is designed to receive liquid neat polymer while
mixing it with feed water to produce and discharge a quality solution from the system.
Research in the science of polymer activation indicates that the activation energy must decrease as the
polymeric chain is uncoiled to prevent rupture and hence decrease the performance of the product.
The mixing by the Polymer Feeder is accomplished
mechanically with three distinct mixing zones separated
by baffles. The first zone consists of a fast mixing blade
that delivers high shear at the precise point of polymer
injection, creating an immediate dispersion before
agglomeration takes place. The second mixing zone
induces a vortex and draws solution down through the
center of the chamber from zone one and forces the
solution outward to the sides and then down into the third
zone. Finally, the third zone mixing blade gently
agitates/blends the active polymer solution before it exits
the chamber via the discharge tube.
The ProMix S & C Polymer Feeder controller offers several operating options. These options are selected using
various combinations of the controller door switch positions and polymer type selections via the controller menu.
The controller allows the polymer pump speed to be controlled either locally via the keypad or remotely via a
customer supplied 4-20 mA signal over a 0 to 100% speed range. The polymer dosage rate must be calculated
and the pump adjusted for the desired ratio concentration of polymer to dilution water leaving the feeder by
volume. Different maximum concentrations are possible based upon the type of polymer. Emulsion polymers
should be limited to a maximum of 1% concentration in the mixing chamber and Mannich polymers should not
exceed 10% in the mixing chamber. The polymer type to be used is selectable from the keypad menu.
The System Start switch on the controller door has three positions, ON, OFF and REMOTE. ON enables the
controller locally and REMOTE allows the controller to be enable via a customer supplied dry contact. The
Polymer Pump switch has two positions, LOCAL and REMOTE. Placing the System Start switch in the OFF
position after having first been in either of the other two positions will initiate a flush cycle for the system before
shutting down.
The Polymer Pump switch on the controller front door has two positions to choose the source of the pump
control signal. In the LOCAL position the controller uses the keypad entry for polymer pump speed. In the
REMOTE position a user supplied 4-20 mA signal representing 0 –100% pump speed controls the pump. The
user must manually adjust the primary and post dilution valves for the desired dilution water flow rate and must
calculate the required pump speed to attain the desired concentration. Rotameters are provided to monitor the
dilution water flow rates.
The ProMix Polymer Feeder is equipped with all the necessary components for easy installation, reliable
performance and safe operation. The design incorporates an electric solenoid valve (water inlet), flow
meter/switch, manually adjustable rotameters for primary and secondary dilution flow, either a peristaltic or
diaphragm type neat polymer pump (depending on model), microprocessor based controller, manual ball valves,
pump calibration column, PVC piping and components, and polymer mixing chamber mounted on a skid to
facilitate proper mixing and delivery.

ProMinent ProMix ‘S & C’ Polymer Feeder
ProMix Series S&C User Manual
ii. ProMix S Systems with Peristaltic Pumps:
Peristaltic Pump Type Blue-White (A-100NV Series):
SYSTEM
PART NO.
MODEL
PUMP TYPE
MAX CAPACITY
1048346
60X1-0.22TA
Blue White A1N00V-1T
0.22 GPH
1048347
60X2-0.95TA
Blue White A1N30V-1T
0.95 GPH
1048348
120X2-0.95TA
Blue White A1N30V-1T
0.95 GPH
1048349
120X2-2.00TA
Blue White A1N30V-2T
2.00 GPH
1048351
300X2-2.00TA
Blue White A1N30V-2T
2.00 GPH
1048352
300X2-3.73TA
Blue White A1N20V-3T
3.73 GPH
**Refer to Appendix C for proper sizing**
Overall Skid Dimensions ..................................................................24” x 34” x 66” (L x W x H)
Overall Weight of Skid ......................................................................................Approx 170 lbs.
Power Requirements ..........................................................120 VAC, 60 Hz, 1 Phase, 15 Amp
Control panel FLA ...................................................................................................11.2 Amp
Volume of Mixing Chamber .....................................................................................2.0 Gallons
Maximum Rated Chamber Pressure .......................................................................... 150 PSIG
Maximum Operating Chamber Pressure .................................................................... 100 PSIG
Normal Operating Pressure .......................50 PSIG or 65 PSIG (Depends on Pump Selected)
Recommended Running Temperature ...............................................................+50°F to 100°F
Water Connection Size ............................................................................................... ¾” FNPT
Solution Discharge Connection Size ........................................................................... ¾” FNPT
Neat Polymer Inlet Connection Size............................................................................ ½” FNPT
Drain Connection......................................................................................................... ¼” FNPT

ProMinent ProMix ‘S & C’ Polymer Feeder
ProMix Series S&C User Manual
ii. ProMix S Systems with Diaphragm Pumps:
Diaphragm Pump Type ProMinent Gamma XL Series:
SYSTEM
PART NO.
MODEL
PUMP TYPE
MAX CAPACITY
1048353
60X1-1.01DA
GLXAUS1608PVT4V000UV4030EN
2.06 GPH
1048354
60X2-1.01DA
GLXAUS1608PVT4V000UV4030EN
2.06 GPH
1048355
120X2-1.01DA
GLXAUS1608PVT4V000UV4030EN
2.06 GPH
1048356
120X2-2.30DA
GXLAUS1020PVT4V000UV4030EN
5.18 GPH
1048357
300X2-2.30DA
GXLAUS1020PVT4V000UV4030EN
5.18 GPH
1048358
300X2-3.70DA
GXLAUS0730PVT4V000UV4030EN
7.76 GPH
**Refer to Appendix C for proper sizing**
Overall Skid Dimensions ..................................................................24” x 34” x 66” (L x W x H)
Overall Weight of Skid ...................................................................................... Approx 170 lbs.
Power Requirements ..........................................................120 VAC, 60 Hz, 1 Phase, 15 Amp
Control panel FLA ...................................................................................................11.5 Amp
Volume of Mixing Chamber .....................................................................................2.0 Gallons
Maximum Rated Chamber Pressure ..........................................................................150 PSIG
Maximum Operating Chamber Pressure .....................................................................100 PSIG
Normal Operating Pressure ........................................................................................100 PSIG
Recommended Running Temperature ..............................................................+50°F to 100°F
Water Connection Size ................................................................................................¾” FNPT
Solution Discharge Connection Size ...........................................................................¾” FNPT
Neat Polymer Inlet Connection Size.............................................................................½” FNPT
Drain Connection..........................................................................................................¼” FNPT

ProMinent ProMix ‘S & C’ Polymer Feeder
ProMix Series S&C User Manual
ii. ProMix C Systems with Peristaltic Pumps:
Peristaltic Pump Type Blue-White (A-100NV Series):
SYSTEM
PART NO.
MODEL
PUMP TYPE
MAX CAPACITY
1048360
60X1-0.22TA
Blue White A1N00V-1T
0.22 GPH
1048361
60X2-0.95TA
Blue White A1N30V-1T
0.95 GPH
1048362
120X2-0.95TA
Blue White A1N30V-1T
0.95 GPH
1048363
120X2-2.00TA
Blue White A1N30V-2T
2.00 GPH
1048364
300X2-2.00TA
Blue White A1N30V-2T
2.00 GPH
1048365
300X2-3.73TA
Blue White A1N20V-3T
3.73 GPH
**Refer to Appendix C for proper sizing**
Overall Skid Dimensions ..................................................................26” x 24” x 50” (L x W x H)
Overall Weight of Skid ..................................................................................... Approx. 130 lbs.
Power Requirements ..........................................................120 VAC, 60 Hz, 1 Phase, 15 Amp
Control panel FLA ...................................................................................................11.2 Amp
Volume of Mixing Chamber .....................................................................................2.0 Gallons
Maximum Rated Chamber Pressure ..........................................................................150 PSIG
Maximum Operating Chamber Pressure .....................................................................100 PSIG
Normal Operating Pressure .......................50 PSIG or 65 PSIG (Depends on Pump Selected)
Recommended Running Temperature ..............................................................+50°F to 100°F
Water Connection Size ................................................................................................¾” FNPT
Solution Discharge Connection Size ...........................................................................¾” FNPT
Neat Polymer Inlet Connection Size.............................................................................½” FNPT
Drain Connection..........................................................................................................¼” FNPT

ProMinent ProMix ‘S & C’ Polymer Feeder
ProMix Series S&C User Manual
ii. ProMix C Systems with Diaphragm Pumps:
Diaphragm Pump Type ProMinent Gamma XL Series:
SYSTEM
PART NO.
MODEL
PUMP TYPE
MAX
CAPACITY
1048460
60X1-1.01DA
GLXAUS1608PVT4V000UV4030EN
2.06 GPH
1048461
60X2-1.01DA
GLXAUS1608PVT4V000UV4030EN
2.06 GPH
1048462
120X2-1.01DA
GLXAUS1608PVT4V000UV4030EN
2.06 GPH
1048463
120X2-2.30DA
GXLAUS1020PVT4V000UV4030EN
5.18 GPH
1048474
300X2-2.30DA
GXLAUS1020PVT4V000UV4030EN
5.18 GPH
1048475
300X2-3.70DA
GXLAUS0730PVT4V000UV4030EN
7.76 GPH
**Refer to Appendix C for proper sizing**
Overall Skid Dimensions ..................................................................26” x 24” x 50” (L x W x H)
Overall Weight of Skid ..................................................................................... Approx. 170 lbs.
Power Requirements ..........................................................120 VAC, 60 Hz, 1 Phase, 15 Amp
Control panel FLA ...................................................................................................11.5 Amp
Volume of Mixing Chamber .....................................................................................2.0 Gallons
Maximum Rated Chamber Pressure ..........................................................................150 PSIG
Maximum Operating Chamber Pressure .....................................................................100 PSIG
Normal Operating Pressure ........................................................................................100 PSIG
Recommended Running Temperature ..............................................................+50°F to 100°F
Water Connection Size ................................................................................................¾” FNPT
Solution Discharge Connection Size ...........................................................................¾” FNPT
Neat Polymer Inlet Connection Size.............................................................................½” FNPT
Drain Connection..........................................................................................................¼” FNPT

ProMinent ProMix ‘S & C’ Polymer Feeder
ProMix Series S&C User Manual
iii. Peristaltic Polymer Pumps used on S & C Models:
Series
Part Number
Ident Code
RPM
Max
Flowrate (GPH)
Pressure
(PSIG)
Min
Rated
Max
Rated
A-100NV
1061489
A1N00V-1T
14
0.012
0.24
65
A-100NV
1061490
A1N30V-1T
60
0.053
1.06
65
A-100NV
1061491
A1N30V-2T
60
0.111
2.22
65
A-100NV
1061492
A1N20V-3T
45
0.207
4.14
50
Notes:
1. Blue White Peristaltic Pumps
2. GPH Rating above based upon pumping Water not Polymer
3. Power Requirements: 120VAC, 60Hz, Single Phase (0.35 Amp)
4. Suction Lift Capabilities: Approx 30ft. (based on water)
5. Tubing: Tygothane

ProMinent ProMix ‘S & C’ Polymer Feeder
ProMix Series S&C User Manual
iv. Diaphragm Polymer Pumps used on S & C Models:
Series
Identification Code
Factory
Default
Mode
SPM
Max
Flowrate (GPH)
Pressure
(PSIG)
Min @
100%
Stroke
Max @
100%
Stroke
GXLA
GLXAUS1608PVT4V000UV4030EN
HV2
120
0.008
1.27
145
GXLA
GXLAUS1020PVT4V000UV4030EN
HV2
120
0.019
3.23
145
GXLA
GXLAUS0730PVT4V000UV4030EN
HV2
120
0.031
4.76
102
Notes:
1. ProMinent –Gamma XL Solenoid Driven Metering Pump
2. Original Pump GPH rating is derated 20% due to Polymer viscosity. The
actual deration may vary depending on the polymer used
3. Control Modes Available *
a. Standard –200 spm: 0-50 cp
b. HV1 (slightly reduced discharge speed) –160 spm: 50-200 cp
c. HV2 (moderately reduced discharge speed) –120 spm: 200-500 cp
d. HV3 (maximum reduced discharge speed)–80 spm: 500-1000 cp
4. Connections: ½” x 3/8” or DN10 Depending on Model Selected
5. Power Requirements: 115VAC, 60 Hz, Single Phase
* Viscosity values are approximate and can vary widely per specific application. Use these
values as a guideline only and consult the factory for specific application capabilities

ProMinent ProMix ‘S & C’ Polymer Feeder
ProMix Series S&C User Manual
1.0 INSTALLATION & QUICK START GUIDE
1.1 Safety:
Utilize appropriate protective safety gear when operating or maintaining this equipment.
Recommended safety gear is as follows:
Personal Protective Equipment (PPE):
•Hard Hats (Where overhead hazards exist)
•Safety Glasses with side shields
•PVC Apron
•PVC Gloves
•Safety-Toed Work Boots
1.2 Delivery & Storage Checklist:
1. Check packing list for completeness and note any missing items immediately.
2. Inspect equipment and shipping container for damages before accepting delivery.
Make note of the carrier’s bill-of-lading the extent of the damage, if any, and notify the
carrier.
3. Store the equipment on firm level surface in original packing container. Do not store the
equipment where it may be exposed to extreme temperatures, precipitation, humidity, or
dust. Avoid direct sunlight that could overheat and damage equipment.
Ambient Conditions for storage and transport:
Temperature: 14°F to 120°F
Air Humidity: ≤92% relative humidity, non-condensing
1.3 Installation Considerations:
•Required Polymer System Voltage
•Available Water Pressure
•Injection Point Pressure
•Number of Injection Points
•Polymer Solution Discharge: For example (Length of Piping Run and Pipe Size)
•Neat Polymer Suction: Flooded or Lift
•Type of Application / Dewatering Device
•Type of Polymer: Emulsion, Dispersion, Solution

ProMinent ProMix ‘S & C’ Polymer Feeder
ProMix Series S&C User Manual
1.4 Installation:
1. Unpack and position equipment on sturdy level surface. Fasten to prevent movement.
2. Do not install equipment in areas of extreme heat, cold, dust or humidity. Avoid areas where
objects or fluids can drop from overhead.
3. Units are to be installed as close to the point of application as possible.
4. Inlet pressure is not to exceed 100 psig working pressure.
5. System pressure at the discharge is not to exceed 80% of inlet pressure.
6. Piping Internal to the System:
a. Inspect the piping for breakage. The system may have been jarred during shipping.
b. Check the tightness on all unions. Hand tighten only –no tools. Unions incorporate an
o- ring seal. Ensure that the o-ring is seated properly prior to tightening.
7. Piping External to the System (Reference Appendix A for connection location):
a. Install piping so that connections properly meet system termination points. Do not “stretch”
field installed piping to meet system termination points. Stressed piping will fail!
b. Piping should be at a minimum ¾” to and from the piping on the system.
c. Avoid gettingdirt and debris inside the piping during installation. Plug endsof piping with
rags if constructionactivitiesare underway. All debris must be flushed from pipingbefore
system start-up.
d. Connect to outlet piping ¾” FNPT from static mixer to associated customerapplication
point.
e. Connect to make-up water inlet piping ¾” FNPT (5 GPM maximum at 100 psig maximum).
f. Connect to Neat Polymer pump inlet piping ½” FNPT.
g. Install ¾” pressure regulator and ¾” y-strainer / basket strainer on the clean make-up
water line if equipment is currently not installed. (Recommended)
h. Allow provisions for draining the system piping. Skid components will require maintenance.
Ensure that chemicals can be evacuated from the skid piping and components for servicing.
8. Electrical Supply Needed for the System:
a. Note: Review local Electrical Code and follow accordingly.
b. Connect incoming power to skid mounted control panel (120VAC, Single Phase, 15 Amp,
60 Hz). Ensure panel is properly grounded.
c. Check electrical connections to be sure proper voltage is supplied to the system.
d. Power the unit using a dedicated, separate breaker in the local lighting distribution panel.
e. Do not route the AC power in common conduit with variable frequency pump drives.
f. Do not put conduitentries in the top of the control panel. Resulting conduit condensation
and failure to seal may damage controller circuit boards.
9. The Overload relay should be set to the Motor Nameplate Full Load Amps. Setting this to a
higher value will result in possible damage to the motor and associated wiring. Overload
conditions should be investigated and possible process changes may need to be made to
prevent overload conditions.
10. Connect Digital Remote Start Functions (note wiring termination points in Appendix B) for
polymer tank level and remote start permissive. Default jumpers should remain in place for any
input not available.
11. Refer to the Blue White A-100NV Installation & Maintenance Manual regarding pump information.

ProMinent ProMix ‘S & C’ Polymer Feeder
ProMix Series S&C User Manual
1.5 Quick Start Guide:
1. After the installation guidelines (Section 1.4) of the manual.
2. Open ball valve on the suction of the pump to allow chemical to flow into the system by gravity.
If the application is suction lift then ensure liquid is present in pump suction.
3. Start up pumps at 100% stroke length and frequency to purge all air and prime the system.
To prime the pump press and hold the PRIME button on the keypad until chemical is visible
in the suction line.
4. Verify motor rotation on Mixing Chamber motor. Normal rotation is CCW.
5. Do not run the mixing chamber motor dry. Damage to the mechanical seal could occur.
6. Close the Post Dilution flow control valve and adjust the Primary Dilution flow control valve
to obtain the flow range required. If additional dilution water is needed adjust the secondary
accordingly.
7. Verify that the maximum polymer injection pump pressure is higher than the system pressure.
8. Perform pump calibration using drawdown calibration cylinder.
9. Check flow calibration and be sure pump meets or exceeds the rated flow capacity.
10. Check flows at 100% capacity.
11. In System Start ON and Polymer Pump LOCAL switch positions the neat polymer pump speed is
adjusted manually using the controller keypad to change the pump rate from 0 to 100% of the
pump rated output.
12. In System Start ON and Polymer Pump REMOTE switch positions the controller receives a
remote customer supplied analog 4-20 mA signal to adjust the desired pump speed from 0 to
100% of the pump rated output. This remote 4-20 mA signal can be scaled at the controller to
enhance the resolution of the pump output control and bias the pump response to the remote
signal. A remote start permissive is optional –if used then System Start switch should be in the
REMOTE position.
13. Confirm proper operation of all instrumentation. For example: Gauge, Rotometer switch, etc.
14. Input functions checked and simulated (remote start/stop, 4-20mA, etc.).
15. Output functions checked.
16. Test the operation of all remaining circuits.
17. Observe system to assure that nothing looks or sounds abnormal.
ProMix S
ProMix C
CCC
Primary Dilution
Post Dilution

ProMinent ProMix ‘S & C’ Polymer Feeder
ProMix Series S&C User Manual
1.6 ProMix Controller Door Switches
Manually adjust the two door switches, ‘System Start’ and ‘Polymer Pump’ for the
desired operating conditions:
System Start door switch
Permits use of remote contact to enable system operation in REMOTE position.
Polymer Pump door switch
Determines the set point for pump control action which can be from the keypad entry in LOCAL or from a 4-20 mA
signal in REMOTE.
Door switch options:
System Start
ON-OFF-REMOTE
controller door
switch
Polymer Pump
LOCAL-REMOTE
controller door
switch
PROMIX OPERATION
ON
LOCAL
Remote Start Contact: N/A
Keypad Local Setpoint: 0 –100% pump speed
Remote Setpoint: N/A
Max. chamber concentration: 1.0%
ON
REMOTE
Remote Start Contact: N/A
Keypad Local Setpoint: N/A
Remote Setpoint: 4-20 mA = 0 –100% pump speed
Max. chamber concentration: 1.0%
REMOTE
LOCAL
Remote Start Contact: Close=start, open=stop
Keypad Local Setpoint: 0 –100% pump speed
Remote Setpoint: N/A
Max. chamber concentration: 1.0%
REMOTE
REMOTE
Remote Start Contact: Close=start, open=stop
Keypad Local Setpoint: N/A
Remote Setpoint: 4-20 mA = 0–100% pump speed
Max. chamber concentration: 1.0%

ProMinent ProMix ‘S & C’ Polymer Feeder
ProMix Series S&C User Manual
1.7 Servicing Guidelines:
•Disconnectelectrical power to the equipment prior to servicing.
•Relieve all pressure from the unit prior to servicing.
•Close all suction and discharge valves.
•Verify dilution water is closed.
•Drain chemical/waterfrom unit prior to disassembly.
•Maintain protective covers over all moving parts.
•Keep body parts, hair and foreign objects from contact with moving parts.
•Do not allow grease or oil to be used or stored around the feed equipment or chemicals.
•Review the Material Safety Data Sheets of the Polymer utilized and observe appropriate safety
measures.
•Mineral Oil can be utilized to aid in the polymer cleaning process.
Ensure all operating & maintenance personnel are instructed regarding the contents of this manual

ProMinent ProMix ‘S & C’ Polymer Feeder
ProMix Series S&C User Manual
2.0 CONTROLLER
2.1 Keypad Navigation
The ProMinent ProMix S Polymer Feeder uses a fixed configuration to deliver the operation
required to operate the feeder. The main board is not interchangeable with other
ProMinent controller hardware.
The top line of the main menu displays the
current feeder state on power ON
Press EXIT during any main menu display
& you’ll return to the top of the menu & the
current feeder state.
The other main menu displays show information
you’ll need to set & adjust feed rate and to verify
flowswitch, 4-20mA in & out…
UP & DOWN to view
options
or to EDIT
numbers
MoveRIGHT to select
next
fieldwhen
EDITing
ENTER to select an
option
& to execute
EDITing
EXIT to escape
option,
info display or
EDITing
EXIT goes to top of Main
Menu

ProMinent ProMix ‘S & C’ Polymer Feeder
ProMix Series S&C User Manual
2.2 Main Menu
This is the power ON, top of the menu display.
Press EXIT at any display to return here.
Displays the Polymer feed rate 0-100% and the current
state of the feeder. See 1.6 for complete state table.
Displays the Polymer Pump feed rate 0-100%
and the controlling 4-20mA current level,
Press ENTER @ Polymer Pump to view-adjust the Manual
Setpoint & Calibrate the 4-20mA controlling the pump.
Mixer ON time resets to zero every time
the Mixer turns
OFF.
Press ENTER during Remote RUN or Local RUN to turn
OFF the Polymer pump and flush the mixer.
The Remote Setpoint 4-20mA current loop controls the
Polymer Pump in Remote RUN mode.
Press ENTER to calibrate.
Flowswitch ON time resets to zero every time
the Flowswitch turns
OFF.
After 24 hours displays >1Day
.
The Remote Start contacts must be closed
for the polymer feeder to run.
Remote Start time resets to zero every time
the contact set opens.
We’re now back at the top of the main menu.
Sidebar:
Press ENTER at Polymer to view and adjust feeder Fill, Flush & Wait-for-Flow timing.
Press ENTER & UP at Polymer to view feeder Diagnostics. Refer to 2.17 for Diagnostic
displays.

ProMinent ProMix ‘S & C’ Polymer Feeder
ProMix Series S&C User Manual
2.3 Adjust Setpoint
Press ENTER @ Polymer Pump
to view or adjust the Local Setpoint
.
Local Setpoint may be adjusted at any time if
Polymer Pump switch is
set to Local mode.
The present Local Setpoint is 25.0%.
Press ENTER to adjust.
Key RIGHT to move the cursor &
UP or DOWN to change the digit.
Key EXIT to abandon or ENTER to execute.
Displays new, adjusted Local Setpoint
.
Press EXIT to return to main menu.
If the Polymer Pump switch is in the Local position, any
adjustment takes effect immediately, modifying the
4-20mA output to the pump.
Sidebar:
Local Setpoint only controls the polymer pump when the Auto-Manual switch is @ Local.
If the Local Setpoint is @ 25% the 4-20 mA current output loop will be at 8mA (4mA + 0.25 x
16mA = 8mA).
Remote Setpoint only controls the polymer pump when the Polymer Pump switch is @
Remote. The polymer pump speed is then controlled by the remote 4-20 mA signal.

ProMinent ProMix ‘S & C’ Polymer Feeder
ProMix Series S&C User Manual
2.4 Modify Timing
Press ENTER @ Polymer
to view or adjust the feeder timing.
Fill Time is the time that the feeder waits to fill the feeder
prior to turning on the Polymer Feed pump. This protects the
mechanical seal of the mixer motor shaft by keeping it wet.
Minimum time is 30 seconds for the first fill only. Thereafter
this step is skipped if operation pauses unless electrical
power to the controller is cycled. Key ENTER to modify.
Flush Time is the time water flows after initiation of a Flush
Cycle. This is a maintenance feature and can be manually
initiated by (1) placing the controller door System Start Switch
in the OFF position for more than 2 seconds or (2) by
opening the remote start contact for longer than 2 seconds or
(3) by using the keypad menu. Key ENTER to modify time.
Wait for Flow may be adjusted to any time
from 1 to 30 seconds.
Press ENTER to adjust.
Diagnostics displays the input current loop power voltage.
Press ENTER to view diagnostic data
set.
Refer to 4.2 for detail.
Interlock (CI) could be set to NO/NC using key
Feed Verify ON/OFF could be set to ON using for pulse
feedback from Metering pump (metering pump must have pulse
(dry contact output)
Feed Verify may be adjusted to any time from 1 to 300 seconds.
Press ENTER to adjust

ProMinent ProMix ‘S & C’ Polymer Feeder
ProMix Series S&C User Manual
Sidebar:
Wait for Flow: Water inlet solenoid open, ON. Mixer and Polymer Pump both OFF.
Factory default = 5 seconds.
The 4-20mA current loop control input may be powered by the site control system
or by the ProMix S 24VDC power supply.
Other manuals for ProMix S
1
This manual suits for next models
1
Table of contents
Popular Mixer manuals by other brands

Western
Western 1200 Operator's manual & parts breakdown

KitchenAid
KitchenAid *521.004 instructions

Medion
Medion MD 16480 instruction manual

A.G. PULIE
A.G. PULIE Easymix TU-MIX operating instructions

Altec Lansing
Altec Lansing 1684A SIGNAL PROCESSING Specifications

Behringer
Behringer Eurorack UBB1002 user manual