ATSC LEVEL
Press LEVEL from the HOME Screen.
The SignalScout continously scans for
ATSC LEVELS on the selected Chan-
nel and Frequency. There are 2 graphs
displayed - the Power Level (Left) and
Signal-to-Noise Ratio (SNR) (Right)
which show the signal strengh, if de-
tected. The signal levels are displayed
numerically under the graphs and can
be toggled between dBm and dBmV.
PRE errors are coding errors in the data that are automati-
cally corrected by a TV’s error correction algorithm. POST
errors cannot be corrected and cause picture problems. The
8 VSB encoding format is displayed.
Select the UP and DOWN ARROW buttons to change the
Channel and Frequency or select the white CHANNEL or
FREQUENCY box to enter a specic number. Select the
GREEN ARROW button to enter a specic number or select
the “X” to cancel and go back to the ATSC LEVEL Screen
without saving the entered data.
Select the SPEAKER icon to enable an audible tone that is
proportional to the received signal strength. (No tone below
-79 dBm)
The built-in COMPASS gives a direc-
tion for aiming the antenna.
When the LOCK icon is shown as
locked and blue, the channel is locked
and being measured.
If AMP is displayed below the LOCK
icon, then the SignalScout is using an
internal amplier to boost the signal
and the system may require an ampli-
er for channel reception.
Psiber Data Systems Inc. warrants that the product shall be free from defects in
parts or workmanship for a period of 12 months from the date of purchase if used
in accordance with Psiber Data Systems Inc. operating specications.
THIS IS THE ONLY WARRANTY MADE BY PSIBER DATA SYSTEMS INC.
AND IS EXPRESSLY MADE IN LIEU OF ALL OTHER WARRANTIES, EX-
PRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR
PURPOSE.
Should any parts or workmanship prove defective, Psiber Data Systems Inc.
will repair or replace at Psiber’s discretion, with no cost to the Buyer except for
shipping costs from the Buyer’s location to Psiber’s location. This is the Buyer’s
SOLE AND EXCLUSIVE REMEDY under this agreement. This warranty does
not apply to products which have been subject to neglect, accident or improper
use, or to units which have been altered or repaired by other than an authorized
repair facility.
Return of Equipment - Return of product to Psiber Data Systems Inc. requires a
Return Merchandise Authorization (RMA). To obtain an RMA, contact us at 619-
clearly marked on the shipping label or package. See sample label:
To: Psiber Data Systems Inc.
RMA# XXXXXXXX
7075-K Mission Gorge Rd., San Diego, CA 92120
Press SNR from the HOME Screen in
the ATSC mode.
ATSC SCAN SNR screen is identical
to the ATSC SCAN screen with the
SNR of the selected channel displayed
instead of TOTAL POWER.
Press ATSC from the HOME Screen to change to CAT V.
Select the LEVEL button to display the CAT V Signal Level
and SNR. This screen setup is identical to the ATSC LEVEL
Screen. The QAM encoding level is displayed. The Sig-
nalScout is 64/256 QAM compliant and DOCSIS 3.1 (OFDM)
signal level compatible.
Select SCAN from the HOME Screen in ATSC mode.
The SignalScout will scan all chan-
nels from the selected frequencies in
the channel plan entered in SETUP
and displays the power levels for each
frequency in a single graph. The chan-
nels are displayed under the graph in
the black bar. The blue bar displays the
virtual channels if entered in SETUP.
Select the UP and DOWN ARROW
buttons to scroll through the channels/
frequencies. The selected channel
POWER LEVEL (dBm) will be displayed as a blue column
with the measured level shown below the graph. The TOTAL
POWER (dBm) is the sum of the power levels of all detected
channels and is used to optimize anten-
na alignment when multiple channels
are present.
TILT is displayed for CATV SCAN in-
stead of TOTAL POWER. TILT is calcu-
lated as the last channel power minus
the rst channel power.
Select the LEARN button to scan all
channels and display the number of
channels detected. 5 64
WARRANTY/SERVICE OPTIONS
ATSC SCAN SNRCATV LEVEL
SCAN
NOISE
Press NOISE from the HOME Screen
in the CATV mode.
The NOISE Power Level graph is dis-
played with the power level number
shown below the graph.