Features
Long-life, 99.97% HEPA (High Efficiency Particulate Air) Media Filter
removes particles 0.3 micron and larger
Carbon Prefilter removes lint and large particles, to extend life of HEPA Filter
Two High Output Ultraviolet Germicidal Lamps
CinQuartz™ Photo Catalytic Oxidation Filter removes unpleasant odors
and Volatile Organic Compounds
Carbon/ Potassium Permanganate Final Filter removes non-organic gases
Kills or inhibits bacteria, viruses, mold, fungi and microbial growth
Easy-to-change filters and lamps
Mobile ….Easily moves from room to room
Powerful Variable Speed motor delivers up to 250 CFM of clean, sterilized air
Ideal for rooms up to 625 ft² (58 m²) for one room air change every 20 minutes
FOR TECHNICAL SUPPORT AND REPLACEMENT FILTERS CALL: 416-410-3450

WHAT THE HEPA, ULTRAVIOLET LIGHT &
PHOTO CATALYTIC AIR CLEANER DOES
The Console HEPA, Ultraviolet Light & Photo
Catalytic Air Cleaner has been designed to remove
particulate such as atmospheric and household
dust, coal dust, insecticide dust, mites, pollen, mold
spores, fungi, bacteria, viruses, pet dander, wood
smoke, cooking smoke and grease, tobacco and
cannabis smoke, and more.
The two non-ozone producing, high output
Ultraviolet lamps provide germicidal sterilization for
bacteria, viruses, mold and fungi and provide
photons to the CinQuartz™ Media (Photo Catalytic
Oxidation Filter) to reduce odors and Volatile
Organic Compounds (VOC’s).
A Final Filter containing a mixture of Carbon and
Potassium Permanganate further reduces odors,
light and non-organic gases.
BENEFITS
Helps provide relief from allergies, asthma, and
other respiratory illness.
Kills or inhibits bacteria, viruses, mold, fungi
and microbial growth.
Eliminates or reduces odors and gases emitted
from air fresheners, carpets, construction
materials, glues, household cleaners, paints,
varnishes, personal care products, press board
furniture, cigarette and cannabis smoke, and
lots more.
Helps reduce housekeeping time and
redecorating costs.
Provides a healthier, more comfortable
environment, year-round.
HOW IT WORKS
Millions of airborne pollutants are carried the Air
Cleaner by a powerful variable speed motor where
they passes through a 5-stage filtration system.
The air passes through a pleated Carbon Prefilter
to remove lint, large particles and heavy weight
gases to extend the life of the HEPA and PCO
filter.
Smaller particles then pass through a long-life,
99.97% HEPA (High Efficiency Particulate Air)
Media Filter which captures particles 0.3 micron
(1/84,000 of an inch) and larger. The filter becomes
more efficient as it gets dirtier with time. This HEPA
filter has more than 40 ft² of collection surface
area.
The clean air passes through a reflection chamber
where two High Output Ultraviolet (C band)
Germicidal Lamps emit powerful UVC light rays
which are designed to kill or inhibit bacteria,
viruses, mold, fungi and microbial growth. These
are non-ozone producing lamps. The Ultraviolet
Light is also used to activate the unique
CinQuartz™ Media located above the UVC lamps.
The CinQuartz™ Photo Catalytic Oxidation (PCO)
Filter is a Quartz media coated with nanoparticles
of Titanium Dioxide (TiO2). The combined action of
the UVC light and the TiO2 decomposes organic
materials into basic molecules such as H2O and
CO2 and reduces odors and VOC’s as a result.
Air then passes through a Final Filter containing a
mixture of Carbon and Potassium Permanganate
pellets further reducing odors and light gases.
Clean air is discharged back into the room.
OPERATING INSTRUCTIONS
Lean Air Cleaner on side panel and pull out of box.
If your unit has any signs of damage, immediately
contact the store where the Air Cleaner was
purchased.
Keep the shipping carton and packaging in case
the need arises to store or transport the unit.
Remove all packaging from the unit. Choose a
suitable location to allow unobstructed circulation
from the front and top of the unit.
The Air Cleaner plugs into a regular outlet at the
voltage shown on rating label.
The Control Switch for the Air Cleaner is located on
the rear of the unit. To turn the Air Cleaner on,
rotate the Control Switch knob clockwise. This
controls the power to the Fan and to the UVC
Lamps. When the Control Switch is turned just
past the click position, the fan is on high speed.
Rotating the Control Switch completely clockwise
reduces the fan speed to it’s lowest setting. When
the Control Switch is turned ON, the Indicator on
the rear of the unit will be illuminated.
The Air Cleaner is designed to run continuously
to provide clean, filtered air 24 hours a day.
Running the Air Cleaner intermittently will
shorten the effective life of the lamps.
Note: Do not allow the cord to be placed
where it may be walked on or allow anything to
roll over it.
WARNING
This unit is designed to emit powerful ultraviolet radiation
to sterilize microorganisms. It is dangerous to come in
contact with or look at the light from this unit. Always
turn the Air Cleaner OFF and UNPLUG the unit before
opening panels or the lamp access door.
2
WARNING
The air cleaner has been shipped without the 2 UVC
lamps installed. The filters are enclosed in plastic bags.
Before running the unit remove the plastic bags and
discard safely. Install the lamps following the
instructions given in the maintenance instructions. Use
the cotton gloves provided when handling the lamps.

MAINTENANCE
For efficient operation, the filters must be
changed on a regular basis. If you notice a
reduction in air flow from the system, check the
filters.
Replacing the HEPA Filter and Prefilter
1. To access the filters, turn the Air Cleaner
OFF at the switch and open the Rear,
Bottom Filter Access Door.
2. Carefully remove the filters to avoid spilling of
collected contaminants. Dispose of filters in a
plastic bag and discard with regular
household trash.
3. Remove the plastic from the new filters
before installing. Discard plastic safely. Take
care not to damage the filters. Hold by the
filter frame only.
4. Date the replacement filter in the space
provided.
5. Place the filters in their appropriate track with
the arrows pointing up.
6. Use genuine replacement filters only. Call
your dealer for parts or call 1-800-267-8305.
Note: When the filters are new, you may
notice a new smell from the system. This is
normal and will dissipate within a few hours.
Prefilter (#DM900-0855): This must be
replaced every 3-6 months. A clean Prefilter will
increase the life of the HEPA Filter and improve
airflow.
HEPA Filter (#DMH4-0400): Replace every 2-3
years. The life of this filter depends on the
amount of contaminants in the air and the
frequency in which the Prefilter has been
changed. Renovations in the home that create
wood, drywall dust or similar contaminants will
shorten the life expectancy of the HEPA filter.
Note: Handle the HEPA filter by the frame
only. The paper is fragile and a puncture or tear
will reduce efficiency.
Replacing the UVC Lamps, PCO Filter and
Final Filter
1. To change the PCO filter, Final filter and UVC
lamps, turn the Air Cleaner OFF and
UNPLUG it. Remove the screws from the
Rear Top Lamp Access Panel and remove
the panel. DO NOT misplace the parts.
2. Carefully remove the filters to avoid dusting
of filter. Dispose of the filters in a plastic bag
and discard with regular household trash.
3. To remove the lamp from the lamp socket,
pull the lamp, by the base, away from the
lamp socket. Remove the lamp from the
support clip. Remove the plastic lamp support
clips by pinching the back of the clip and
lightly pulling away from the reflector.
3
Fig. 1 – Air Cleaner Layout
CAUTION
When replacing the filters wear disposable gloves and a
dust mask.
CAUTION
This unit is not intended for use where there are high
levels of industrial chemicals present.
WARNING
Never use the Air Cleaner without all of the filters in
place and all cover panels and doors closed. Make sure
all the screws are in place.
CAUTION
Make sure to turn the Air Cleaner OFF before
performing any maintenance or removing any filters.
WARNING
Make sure the Air Cleaner is OFF and UNPLUGGED
before opening the lamp access panel.
WARNING
Eye and skin damage may result from direct exposure to
the light produced by the lamp used in this product.
NEVER open the lamp access panel without having
the Air Cleaner unplugged.

4. Before replacing the lamps, the reflector should be
cleaned with a soft cloth and mild non-abrasive
soap.
5. Replace the support clips by pressing them into
the hole in the reflector.
6. NEVER use any lamp other than from the
original manufacturer. NEVER run the Air Cleaner
with only one lamp.
7. When replacing the lamp, use gloves to prevent
oil from being deposited on the glass. Hold the
lamp by the base and slide the glass end into the
plastic support clip. Slide the lamp straight into the
lamp socket until the lamp locks into place.
8. Remove the new PCO filter from the bag and slide
into the upper track above the lamps with the
fuzzy side down towards the lamps. During
shipping and handling a small amount of white
dust is created. This can be cleaned by
vacuuming. DO NOT vacuum the filter.
9. Remove the final filter from the bag and slide it
into the track above the PCO filter with the arrow
pointing up.
Note: The Air Cleaner will not operate with this
filter removed.
10. Replace the lamp access panel tightening all
screws. Do not over tighten.
The PCO Filter will discolor with use. This is
normal.
PCO Filter (#DM900-0450): This must be replaced
every 2-3 years.
Final Filter (#DM900-0810): This must be replaced
at least once a year.
UVC Lamp (#DM900-0191) (2 required): Replace
every 2-3 years. Includes lamp support clip. Lamp
may still light after 2 years but intensity of the
germicidal wavelength will be reduced.
UVC Lamp / PCO Maintenance Kit (#DM900-1002):
Kit contains 2 UVC lamps, 2 lamp support clips, 1
PCO filter and gloves.
Complete 2-3 Year Maintenance Kit (#DM900-
1003): Contains 1 HEPA filter, 4 carbon prefilters, 2
UVC lamps, 1 PCO filter, 2 carbon/potassium
permanganate final filters, gloves.
4
WARNING
Eye and skin damage may result from direct exposure to
the light produced by the lamps used in this product.
Make sure the Air Cleaner is OFF and UNPLUGGED
before the lamp access panel is open.
CAUTION
Do not touch the lamp glass with bare hands. Always
use the gloves provided when installing the lamps. The
oil from your hands may reduce the effectiveness of the
lamp. The lamp may be cleaned with a soft cloth
dampened with water to remove finger prints.
CAUTION
The lamps operate at a very high temperature. Allow the
lamps to cool 10 minutes before touching.
WARNING
Never use the Air Cleaner without all of the filters in
place and all cover panels and doors closed. Make sure
all the screws are in place.
CAUTION
When the unit is new or after the lamps have been
replaced there may be a temporary odor. An odor may
also occur with high concentrations of chemicals in the
home such as paint or strong cleaning solutions. Both
odors are temporary and should dissipate within a short
time.
CAUTION
Always dispose of plastic bags safely. Do not allow
children or pets to play with empty plastic bags.
CAUTION
The lamps contain a very small amount of mercury
(Hg). In case of accidental breakage, handle with
extreme care. According to the EPA website, open
windows in the affected area and leave the room for 15
minutes. Do not vacuum or use a broom to clean.
Wear a dust mask and use disposable gloves. Scoop
fragments using stiff paper or cardboard. Place
fragments in a plastic bag. Wipe area with damp paper
towels and place towels in the plastic bag. Seal bag
and dispose of waste following local guidelines. Wash
hands with mild detergent and water. See the EPA
website (www.epa.gov) for more information.
CAUTION
The lamps used in this air cleaner contain a very small
amount of mercury (Hg). The lamps should be
disposed of according to local ordnances or refer to
www.lamprecycle.org.

Dimensions
(including casters) Height
Width
Depth
30.25 in
16.5 in
15.5 in
76.8 cm
41.9 cm
39.4 cm
Unit Weight 46 lbs 20.9 kg
Input Voltage 120 V 60 Hz
Power Consumption 180 Watts
Air Flow 250 CFM 424.8 m³/hr
Cabinet 22 gauge
Power Cord 9.0 ft 2.74 m
Filter Dimensions Prefilter
HEPA Filter
PCO Filter
Final Filter
16 x 12 x 1 in
16 x 12 x 2.5 in
16 x 10 x 0.375 in
16 x 10 x .5 in
40.6 x 30.5 x 2.5 cm
40.6 x 30.5 x 5 cm
40.6 x 25.4 x 0.95 cm
40.6 x 25.4 x 1.3 cm
Ultraviolet Power in Reflector >10,000 μW/cm²
HEPA Collecting Surface Area 40 ft²3.7 m²
TECHNICAL DATA
5
IMPORTANT SAFEGUARDS
Safety points you should know about your Air Cleaner
Caution:
** Read Owner’s Manual and safeguards before using
** Save Owner’s Manual for later use
** Follow all warnings and instructions marked on Air Cleaner
FOR YOUR PERSONAL SAFETY
1. The Air Cleaner is equipped with a grounded plug. Do not
defeat the purpose of this plug by removing the grounding pin,
as this may result in an electrical shock or create an unsafe
condition.
2. When the power cord or plug is damaged or frayed, unplug the
Air Cleaner from the wall outlet and refer servicing to qualified
service personnel.
3. Do not overload wall outlets and extension cords, as this can
result in fire or electric shock.
4. Do not allow anything to rest on or roll over the power cord, and
do not place the unit where power cord is subject to traffic or
abuse. This may result in a shock or fire hazard.
5. Do not attempt to service the Air Cleaner yourself as opening or
removing switch cover may expose you to dangerous voltage or
other hazards. Refer all servicing to qualified personnel.
6. Never push objects of any kind into the Air Cleaner through
cabinet slots, as they may touch dangerous voltage points, or
short out parts that could result in a fire or electric shock.
7. If the Air Cleaner has been dropped or the cabinet has been
damaged, unplug the unit from the wall outlet and refer
servicing to qualified service personnel.
8. Unplug the Air Cleaner from the wall outlet before cleaning. Do
not use liquid cleaners or aerosol cleaners on cabinet. Use a
damp, lint-free cloth for cleaning.
9. Do not use the Air Cleaner near water, i.e. near a bathtub, sink,
laundry tub, in a wet basement, in the rain or near a swimming
pool, etc.
If liquid has been spilled into the Air Cleaner, unplug the unit
from the wall outlet and refer servicing to qualified service
personnel.
10. Do not use the Air Cleaner near open fire or flame, or sources
of heat i.e. fireplaces, wood burning stoves, kerosene heaters,
stove tops, ovens, etc.
11. Do not use the Air Cleaner on soft surfaces i.e. beds, sofas.
12. Do not use the Air Cleaner when oxygen is being used or when
combustible gases are present.
13. The Air Cleaner has slots or openings in the cabinet for
ventilation purposes, to provide reliable operation of the unit,
and to protect it from overheating. These openings must not be
blocked or covered.
14. The Air Cleaner should be operated only from the type of power
source indicated on the rating label. If you are not sure of the
type of power supply at your home, consult your local power
company.
15. If the Air Cleaner does not operate normally by following the
operating instructions, unplug the unit from the wall outlet and
refer servicing to qualified service personnel.

PURDist-PD900P
01/20
CONSOLE HEPA, ULTRAVIOLET LIGHT & PHOTO CATALYTIC AIR CLEANER
LIMITED FIVE (5) YEAR WARRANTY
FIVE YEAR WARRANTY - This PUR product is warranted to the original owner, to be free from electrical and
mechanical defects in material and workmanship, under normal use and maintenance, within its listed capacity, for a
period of five (5) years from the date of purchase, excluding the lamps or lamp ballast which are warranted for one (1)
year from the date of purchase. This warranty does not include the Prefilter, HEPA Filter, CinQuartz™ Photo Catalytic
Oxidation Filter or Carbon/Potassium Permanganate Final Filter. A new or remanufactured part to replace the
defective part will be provided without charge for the part itself, through PUR Distribution, provided the defective part
is returned to PUR Distribution prepaid, together with the serial number and proof of purchase. Defective parts must
be packaged well and depending on the part, may require images emailed to PUR Distribution prior to shipping, to
confirm condition of parts. If goods arrive damaged due to improper packaging, warranty will be void. The
replacement part assumes the unused portion of the warranty. Failing this, PUR Distribution will guarantee the unit
for a period of sixty (60) months from the date of manufacture, according to the manufacturer’s records and conditions
stated in this warranty.
THIS WARRANTY DOES NOT INCLUDE ANY ADDITIONAL LABOR ALLOWANCE OR OTHER COSTS incurred
for diagnosis, repairing, removing, installing, shipping, servicing, or handling of either defective parts or replacement
parts.
LIMITATIONS OF WARRANTY - All implied warranties (including implied warranties of merchantability) are hereby
limited in duration to the period for which the limited warranty is given. The expressed warranties made in this
warranty are exclusive and may not be altered, enlarged, or changed by any distributor, dealer or other person
whatsoever.
PUR DISTRIBUTION LTD. WILL NOT BE RESPONSIBLE FOR:
1. Normal maintenance as outlined in the Owner’s Manual including cleaning and/or replacement of filters and
ultraviolet lamps.
2. Damage or repairs needed as a consequence of any misapplication, failure to perform normal maintenance,
negligent handling, improper servicing, unauthorized alteration, or improper operations.
3. Damage or repairs required as a consequence of faulty installation or application by others.
4. Failure to start due to voltage conditions, blown fuses, open circuit breakers or other damages due to the
inadequacy or interruption of electrical service.
5. Damage as a result of floods, winds, fires, lightning, accidents, corrosive atmosphere, or other conditions beyond
the control of PUR DISTRIBUTION LTD.
6. Parts, including filters and ultraviolet lamps, not supplied or designated by PUR DISTRIBUTION LTD.
7. PUR DISTRIBUTION LTD. products installed outside of Canada.
8. Any personal injury, special indirect or consequential property or commercial damage of any nature whatsoever.
Some jurisdictions do not allow the exclusion of incidental or consequential damages, so the above limitation may
not apply to you.
Model No. Serial No.
Date of Purchase Owner’s Name & Address
RETAIN THIS CERTIFICATE WITH YOUR DOCUMENTS
PUR DISTRIBUTION LTD.
Tel: (416) 410-3450
Table of contents
Other PUR Air Cleaner manuals