1
Introduction
To the user of PURE Humidifier Co.’s Electric
Humidifiers
We at PURE Humidifier Co. thank you for choosing one of
our quality products. PURE Humidifier Co. Electric Series
Humidifiers are models of simplicity to install, operate, and
maintain. However, they must be maintained to provide
maximum operating efficiency.
PLEASE READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY. PROPER OPERATION AND HUMIDITY
CONTROL IS POSSIBLE ONLY WITH PROPER
INSTALLATION AND MAINTENANCE.
The “ER” Series Humidifier utilizes a Tri-Probe conductive-
type water control system, which is designed for use with
standard (hard or soft) tap water. Use of deionized,
demineralized, or reverse osmosis water will cause a failure
of the water level control system and void the warranty.
High chloride content in feed water can cause chloride stress
cracking and chloride pitting in stainless components.
Chloride stress corrosion cracking (CSCC) and chloride
pitting of stainless steel components is not covered by
warranty. Do not use hydrochloric acid descalers or bleach
to clean the tank. Consult the factory if you are unsure about
which chemical descaler to use.
PURE Humidifier Co.’s “ERDDR” Series should be installed
on applications that require deionized, demineralized, or
reverse osmosis water.
To ensure proper installation of this product, it must be
installed by qualified HVAC and electrical contractors, and
must be in compliance with local, state, federal, and
governing codes. If installed improperly this product may
cause damage to property, severe personal injury, or death
as a result of electric shock, burns, and/or fire.
Do not adjust any components inside humidifier control box
without consulting the factory.
The PURE Humidifier Co. Warranty
PURE Humidifier Co. guarantees its products to be free from
defects in material and workmanship for a period of one year
from the date of shipment; provided the product is properly
installed, serviced, and put into the service for which it was
intended.
PURE Humidifier Co. is obligated under the terms of this
warranty to the repair or replacement of the defective part(s),
excluding any labor charges, or to refund the purchase price
at our option. PURE Humidifier Co. assumes no obligation
for incidental or consequential damages. The above
provisions are in lieu of all other guarantees, obligations,
liabilities or warranties, expressed or implied.
Table of Contents
Introduction 1
Capacity & Weights 2
Electrical Specifications 2
Dimensions & Layout 3
Humidifier Layout 4
Location 5
Drain Pan Mounting 6
Flexible Hose Kit Installation 7
Piping 8
Blower Pack 9-10
Pre-Startup Checklist 11
Non-INTAC® Start-Up Procedure 12
INTAC® Start-Up Procedure 13
Maintenance & Cleaning Instructions 14
Cover Gasket Replacement Instructions 15
Troubleshooting 16
Tool Requirements & Torque List 17
Maintenance Notes 18
Exploded Parts Drawing 19
Parts List 20