INSTALLATION OF FM-2000 AIR CLEANER
EQUIPMENT:
1. Each FM-2000 unit is equipped with two (2) eye bolts, two (2) eye lags and
industrial hanging wire for easy installation.
2. The FM-2000 has a ten foot power cord and a three prong grounded plug.
Electrical: 120 Volts, 9 Amps.
3. Each unit includes a 1-year supply of filters, which consists of twelve (12) pre-
filters, three (3) charcoal filters and one (1) H.E.P.A. filter.
INSTALLATION:
Step 1. Remove the system from the shipping container. Remove the adjustable louver
door from inside the system. After you have removed the adjustable louver door, remove
the industrial staples and the H.E.P.A. bar and then slip out the H.E.P.A. filter. The
H.E.P.A. filter is a pleated media surface with a particle board frame. Removing the
H.E.P.A. filter will make the system lighter for installation purposes.
Step 2. On either side of the system there are two mounting holes where the eye bolts are
inserted. It is easiest to screw the eye bolts into these mounting holes before mounting
into the ceiling. If the area above the drop ceiling is tight for space, then you may need to
put the eye bolts in the mounting holes after you have the system into the drop ceiling.
Step 3. Remove the ceiling tile(s). The system will fit into either one 2’x 4’ or two 2’x 2’
tiles.
Step 4. A system being installed into a drop ceiling that has joints, steel girders or
exposed beams above can be hung without the eye lags (see step 5). At least one eye lag
will be needed if your system is being installed into a ceiling that is solid above (see step
6).
Step 5. Locate either a joist, girder or beam that is directly above the tile where your
system will be installed. After you have located a joist, girder or beam, drape the
industrial hanging wire over the apparatus so that either side is evenly dispersed. Line up
the eye bolts with the hanging wire so they are vertical. Thread one end of the hanging
wire through one of the eye bolts, loop the wire and twist tightly together. Thread the
opposite end of the hanging wire through the opposite eye bolt. Pull the wire tight. The
system should be only slightly resting on the grid work of the drop ceiling. After you
have adjusted the weight of the system on the grid work, then loop the wire and twist
tightly together.