PURE Nanosteamer Clinical User manual

NANOSTEAMER CLINICAL
User Manual

IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, especially when children are present,
basic safety precautions should always be followed, including the following:
WARNING
– To reduce the risk of burns, electrocution, fire, or injury to persons:
1. An appliance should never be left unattended when plugged in.
Exception: This instruction is not required for a permanently installed
wall-mounted hair dryer.
2. Close supervision is necessary when this appliance is used by, on, or near
children or individuals with certain disabilities.
3. Use this appliance only for its intended use as described in this manual. Do not
use attachments not recommended by the manufacturer.
4. Never operate this appliance if it has a damaged cord or plug, if it is not working
properly, or if it has been dropped, damaged, or dropped into water. Return the
appliance to a service center for examination and repair.
Exception: The "or if it has been dropped" part of this instruction is not required for
a hand-supported hair dryer.
5. Keep the cord away from heated surfaces. Do not wrap the cord around the
appliance.
6. Never block the air openings of the appliance or place it on a soft surface,
such as a bed or couch, where the air openings may be blocked. Keep the air
openings free of lint, hair, and the like.
7. Never use while sleeping
READ ALL INSTRUCTIONS BEFORE USING
DANGER – To reduce the risk of electrocution:
1. Always unplug this appliance immediately after using.
Exception: This instruction is not required for a permanently installed
wall-mounted hair dryer.
2. Do not use while bathing.
3. Do not place or store appliance where it can fall or be pulled into a tub or sink.
4. Do not place in or drop into water or other liquid.
5. Do not reach for an appliance that has fallen into water. Unplug immediately.
Exception: The instruction for a permanently installed wall-mounted hair dryer
shall state "If hand unit falls into water, turn unit off immediately. Do not reach into
water. "

WARNING & SAFETY
Turn off & unplug the Nanosteamer Clinical before adding water to the water
tank.
Only use distilled water with the Nanosteamer Clinical.
Do not immerse any part of the Nanosteamer Clinical in water.
Avoid direct heat and damp surfaces when using the Nanosteamer Clinical.
Only water-soluble essential oils can be added to the aromatherapy basket.
Aromatherapy basket heats up while in use. Avoid direct contact.
Prior to your first use of Nanosteamer Clinical on your skin, it is recommended
to let one cycle of water run through and evaporate.
While using the Nanosteamer Clinical it is recommended to adjust distance
accordingly to allow proper ventilation between steam and skin. Caution:
STEAM IS HOT
If you experience pain or discomfort during your session, immediately stop
and consult your physician.
Do not shake or move the Nanosteamer Clinical during use.
It is recommended to clean out the aromatherapy basket after each use.
It is recommended to clean the outside of the Nanosteamer Clinical after each
use by wiping with a damp towel, followed with a dry towel.
Avoid using the Nanosteamer Clinical if you have sensitive skin or a medical
condition affecting your skin.
Keep out of reach of children and pets.
Unplug the Nanosteamer after each use, before cleaning, and before
maintenance.

NANOSTEAMER CLINICAL FUNCTIONS
Hot steam helps to open pores, hydrate and purify the skin.
Cold steam function helps to tighten pores and refresh the skin, and lock in
moisture.
Smart steam function provides an anti-aging
Aromatherapy function allows essence oil to penetrate the skin deeper.
STRUCTURE
Water Tank
Aroma Basket
Basket Cover
Long Nozzle
Short Nozzle
LED Display

MODE FUNCTIONS
Cleansing Mode: Makeup removal and deep cleanse. To be used prior to any
other function.
Cold Steam: Tightens pores to lock in moisture.
Hot Steam: Relaxes pores and allows them to be receptive to moisture.
Smart Steam Mode: A combination of hot & cold alternating steam for
maximum anti-aging benefits.
Hydration Mode: Hydrates dry skin and locks in moisture.
Oil-Control Mode: Locks in moisture while helping control oily skin types.
MODE USE
Cleansing Mode: 4 minutes of hot steam. The Nanosteamer Clinical will
automatically shut off.
Cold Steam: Appropriately adjust distance of steam to skin. Can be used for
60-70 minutes.
Hot Steam: Appropriately adjust distance of steam to skin. Use hot steam for
2-3 minutes. After hot steam, follow with skin care and additional treatments.
Smart Steam Mode: Cold, 3 minutes. Hot, 3 minutes. The Nanosteamer Clinical
will automatically shut off after 20 minutes.
Hydration Mode: Hot, 6 minutes. Cold, 1 minute. Hot, 3 minutes, Cold, 1 minute,
Hot, 3 minutes, Cold, 1 minute. The Nanosteamer Clinical will automatically
shut off.
Oil-Control Mode: Hot, 6 minutes. Cold, 3 minutes. Hot, 3 minutes, Cold,
2 minutes, Hot, 2 minutes, Cold, 1 minute. The Nanosteamer Clinical will
automatically shut off.

HOW TO USE - AROMATHERAPY BASKET
HOW TO USE - PREPARATION
Fully remove any makeup, dirt and oil with your face cleanser
Remove aromatherapy
basket & cover
Place drops of water-soluble
essential oils in basket
Place aromatherapy
basket back in the
Nanosteamer Clinical
Place cover back on
aromatherapy basket

HOW TO USE - PREPARATION (CONTINUED)
Pop out the water tank by
pressing the lid.
Fill water tank with 235ml
of pure or distilled water
Press the lid to place
water tank back in the
Nanosteamer Clinical
Remove water tank cap by
twisting counter-clockwise
Place water tank cap back on
and turn cap clockwise to close
Plug in the Nanosteamer Clinical

HOW TO USE - COLD STEAM
Press the M button to
choose the appropriate
mode on the LED display
After use - hold down on
power button to turn off
the Nanosteamer Clinical
Adequately adjust the distance
between skin and steam
Unplug after use
When power button turns orange it will shut off automatically after about 3 seconds

HOW TO USE - OTHER MODES
The Nanosteamer Clinical will shut off automatically when mode time is
complete
To stop, press the power button for three seconds
Press the M button to
choose the appropriate
mode on the LED display
Choose the mode and
time according to your
preference
Adequately adjust the distance
between skin and steam. 25cm
(9-10 inches) is recommended
Unplug after use
If there is low water, the power button will turn orange and will automatically shut off
after blinking for about 3 seconds.

HOW TO USE - REMOVING WATER
Wait three minutes
before removing water
tank basket, allowing the
temperature to decline
Drain water from the
base of the Nanosteamer
Clinical
Remove aromatherapy basket
and water tank
Wipe down the Nanosteamer
Clinical with a dry towel

HOW TO CLEAN THE NANOSTEAMER CLINICAL
Unplug the Nanosteamer Clinical and drain out water
Pour 1 cup of a 50/50 vinegar & water solution into the water tank
Turn on Hot Steam Mode for approximately 10 minutes
Hold down the power button to turn off the Nanosteamer Clinical
Allow Nanosteamer Clinical to cool for approximately 10 minutes and then drain
Pour distilled back into the water tank to rinse out any residual vinegar smell
It is recommended to clean your steamer every week if used regularly
TROUBLESHOOTING

TECHNICAL DATA
MAINTENANCE
The water tank can only use distilled water. Do not add other liquids.
Make sure your Nanosteamer Clinical is turned off and unplugged prior to adding
water to the water tank.
When using Hot Steam allow adequate distance between steam and face to
avoid any injuries.
When using the Nanosteamer Clinical, always exercise caution to prevent
accidents.
Do not submerge Nanosteamer Clinical in water.
Please use the correct supply voltage of 120V/60Hz/
Do not add any chemical solvents or cleaners to the water tank.
Keep power cord at a distance from hot surfaces
If power cord is damaged, it must be replaced by designated maintenance staff
or equivalent professional
Do not disassemble or install the Nanosteamer Clinical without permission
If there is any problem with the electrical equipment, please contact support@
puredailycare.com
After using the Nanosteamer Clinical unplug the power cord before cleaning.
Do not use abrasive cleaners or corrosive liquids to clean the Nanosteamer
SAVE THESE INSTRUCTIONS
Clinical.
Note: This manual is to ensure the accuracy and rigor of the information provided, but in view of the
continuous improvement and upgrades of the product, the company reserves the right to change the
manual without prior notice.
Nanosteamer Clinical
Voltage: 120V
Power: 320W
Frequency: 60Hz
Capacity: 235mL

Table of contents
Other PURE Kitchen Appliance manuals