Purelogic CQ Series User manual

CQ Serie s Coun ter /Timer
CQ Series Multi-function Timer/Counter
User’s Maual
KKCQE01-1
For your safe, please read the below content carefully before you use the timer/counter!
For your safe, please read the below content carefully before you use the timer/counter!
Safe Caution
Please comply with the below important points:
Warning An accident may happen if the operation does not comply with the instruction.
Notice An operation that does not comply with the instruction may lead to product damage.
The instruction of the symbol in the manual is as below:
An accident danger may happen in a special condition.
Warning
1. A safety protection equipment must be installed or please contact with us for the relative information if the product is used under
the circumstance such as nuclear control, medical treatment equipment ,automobile, train, airplane, aviation, entertainment or safety
equipment, etc. Otherwise, it may cause serious loss, fire or person injury.
2. Apanel must be installed, otherwise it may cause creepage (leakage).
3. Do not touch wire connectors when the power is on, otherwise you may get an electric shock.
4. Do not dismantle or modify the product, If you have to do so, please contact with us first. Otherwise it may cause electric shock
and fire.
5. Please check the connection number while you connect the power supply wire or input signal, otherwise it may cause fire.
.
Caution
1. This product cannot be used outdoors. Otherwise the working life of the product will become shorter, or an electric shock accident
may happen.
2. When you connect wire to the power input connector or signal input connectors, the moment of the No.20AWG (0.50 mm2) scrwew
tweaked to the connector is 0.74n.m-0.9n.m. Otherwise the connectors may be damaged or get fire.
3. Please comply with the rated specifications. Otherwise it may cause fire after the working life of the product becomes shorter.
4. Do not use water or oil base cleaner to clean the product. Otherwise it may cause electric shock or fire, and damage the product.
5. This product should be avoid working under the circumstance that is flammable, explosive, moist, under sunshine, heat radiation and
vibration.
6. In this unit it must not have dust or deposit, otherwise it may cause fire or mechanical malfunction.
7. Do not use gasoline, chemical solvent to clean the cover of the product because such solvent can damage it. Please use some soft
cloth with water or alcohol to clean the plastic cover.
With counting/length counting/timing function
Dual line 6 digits LED display
With up/down counting , timing function ,
8 kinds of output modes
Width of input signal can be selected
Mounting deepth is only 68mm , saving insalling space .
Features:

CQ□□-R C□□
Display digit
6
6digits
Output
:
R
:
Relay output
Power
F
24VDC powersupplyBlank
Switchpowersupply
Dimension
:
4
:
48W*48H*68 7
:
72W*72H*68
CQ series multi-functiontimer/counter
□□ □□
Alarm
:
B
:
1loop C
:
2loops
1.Code illurstration
KKCQE01-2
Code Panel Size
(
mm)
6digits
6digits
6digits
6digits
S/N
1
2
3
4
LEDDisplay DigitAlarmOutput
72H×72W
72H×72W
48H×48W
48H×48W
2
1
2
1
CQ7-RC60
CQ7-RB60
CQ4-RC60
CQ4-RB60
2.Ordering Code
3.TechnicalSpecification
Product series
Displaydigit
Allowablevoltage floating range
Input pulse counter
Timer
Input
Delaytime
Control output
Counter
Timer
Contacts
SolidStateRelay
Auxiliarypower
Ambient Temperature
Storetemperature
AmbientHumidity
TimeAccuracy
Anti-interference(ACPower)
LifeSpan
CQSeriestimer/counter
Duallinesof 6-digitLED
AC85-265VAC50/60Hz
90%-110% ofRatedvoltage(AC)
1cps,30cps,1kcps,5kcp
Countingspeed
CP1,CP2,PAUSE,EXTERNAL_RESET select1ms or20ms
Reset input:selecct1ms or20ms
Selectablevoltageinput orNo-voltageinput
0.01-9999.99Sselectable
0.01-9999.99Sselectable
NO:250VAC3AimpedanceNC:250VAC2Aimpedance
Max30VDC ,Max100mA
10years
12VDC±10%Beblow100mA
-10℃~50℃(Non-freezing)
-25℃~65℃(Non-freezing)
35-85%RH
PowerOn:±0.05%±0.05sec Startsignal:±0.05%±0.03sec
Min100MΩ(at500VDC )
2000VDC 50/60Hz1min
±2kVinterferencedbysquarewavegenerator(Pulsewideth:1us)
Amplitude
:0.75mmF
requency
:10to55Hzeachdirction ofX,Y,Z for1hour
Amplitude
:0.5mm F
requency
:10to55HzeachdirctionofX,Y,Zfor10min
Above10,000,000times
Above100,000times(NO:250VAC3AloadNC:250VAC2Aload)
DesignNo.
Ratedvoltage
wideth
voltageinput:inputimpedance 5.4KΩ,“H”:5-30VDC “L”:0-2VDC
Vibration Mechanical
Mechanical
Malfunction
Electric
Residualvoltage:Max2VDC Open-circuit impedance:Min100KΩ
No-voltageinput:Short-circuit impedance:Max 1KΩ,
capacity
capacity
Insulationresistance
Dielectricstrength
Memorytime

KKCQE01-3
4.PanelIndication
Functionandconfirm
Shift
Output indicator
Add/Decreace
Reset
CNT:Counting mode
TMR:Timingmode
H:Timingunit--hour
M:Timingunit--minute
S:Timingunit--second
5.Operation process
5.2
*
or mode
>5Senterfunction menu
SET
1
Measuringstatus
Confirmandenternext menu
SET
Selectcounting ortimingmode
2
>5Sreturntomeasuring satus
SET
*Ifenterthechangingmode offunctionmenu , pressSET for5sreturntomeasuringstatus, bothdisplayvalueandoutput willbereset.
5.1、How tochange the presetvalue oftiming/counting
*
2
Select the dataneeding revised on the second row
and makeit flick
Addthe flicking data
Decreasethe flicking data
Confirmthe changed dataand enter set value changing
mode of OUT2
SET
1
Enterpreset value changing modeof OUT1
Measuringstatus
Select the dataneededtoreviseof the second line
and shining it
Addthe shiningdata
Decreasethe shining data
Comfirmandreturntomeasuring status
SET
3
Withoutoperation forabove30S
,
returntomeasuring statusautomatically
If preset valueisn t,display ,pleasereset it .
it will
set as
If lockmenu select or , presetvaluechanging modecouldn tbe entered .
If enterthepreset value changing mode ,dont operateforabove30s, it willreturntomeasuringstatusautomatically, allthe changed value wouldnt be saved.
Howtoenterfunction menu
Notoperateforabove30s, it willreturntomeasuringstatusautomatically
If lockmenuisset as, themenu can just bereviewed, andcouldnt be changed.
If enterthe changingmode offunctionmenu, andnotoperatefor30s, it willreturntomeasuring statusand allthechangeddatawouldnt be saved .

KKCQE01-4
Menu Selection
Up/DownMode
() Up:Timefrom0(ZERO)tothesettingvalue
Down:Timefromsettingvalueto 0(ZERO)
CP1、CP2、RESET、PAUSE ,
TimeRange UnitIndication RangeIndication
FunctionSetting
0.01s~9999.99s
0.1s~99999.9s
1s~999999s
0.01s~99m59.99s
0.1s~999m59.9s
0.1m~99999.9m
1m~999999m
1s~99h59m59s
1m~9999h59m
SEC
SEC
SEC
S
S
HS
H
9999.99
99999.9
999999
99.59.99
999.59.9
99999.9
999999
99.59.59
9999.59
Output Mode
()
7.TimeRange
6.Timefunctionmodesetting
Counting/Timing
TimeRange
RST
Lock key
Lock key
RST
Lock
Output Time
() Timedelayrange:0.01-9999.99s
Select theneedriviseddataof thebelowline and shiningit
Addtheshining data
Input logic
()
signalinputtime
Savethe countingvalue
()
Lockkey
Poweroff Countingreset
Poweroff Savethecountingvalue
NPNorPNPinput
SET
SET
SET
SET
SET
SET
SET
SET
SET
Originalsettingvalue
CountingTiming
Decreadethe shining data
theminpulsewidthofsignal(ms)
Cancellocksatus
()
()

KKCQE01-5
A-U
(Up)
CP1:
CP2:
(The counting input isinfluenced byCP1)
When CP1isL ,
Setting forinhibit counting(CP2:LchangestoH)
Releaseinhibit counting(CP2:H changestoL)
Countinggraph
9.Input modeof counter
CP1
CP2
8.Setting the function mode of counter
▲
Maxcountingspeed
(CP)
Preset
() Value setting range ofP:0.001-99.999(Therealquantityofapulse)
▲
Input Mode
( )
decimalpoint
()
Counting/Timing Counter Timer
Addtheshining data
Delayrange:0.01-9999.99s
Selecttheneedreviseddataofthebelowlineand shiningit
Addtheshining data
Decreasethe shining data
Beused toselectthe output type of sensor:NPNorPNP
()
Poweroff Reset countingvalue
Poweroff Savecountingvalue
SET
SET
SET
SET
SET
Minreset time
()
Output mode
()
Delaytime
()
Input logic
()
()
SET
SET
SET
SET
SET
SET
RST
Lock
Lock Lock
RST
ModeSetting Selectionsetting(
Selecttheneedreviseddataofthebelowlineand shiningit
Decreasethe shining data
MinpulsewidthofRESET PAUSEsignal(ms)
Countingvaluesaving
Lockkey
key
Input mode Remark
Countinginput
Inhibit Countinginput
Countingvalue
Nocounting
Cancellock

KKCQE01-6
A-U
(Up)
A-D
(Down)
CP2:Countinginput
CP1:Inhibit counting input
(Countinginput islimittedbyCP2)
When CP2set toH,
CP1:Countinginput
CP2:Up/Downorderinput
When thesignalofCP2isL,counting up
When thesignalofCP2isH,counting down
CP1:Upcountinginput
CP2:Downcounting input
CP1andCP2change fromLtoH at the
same time,
theformercounting stauswillkeep .
Input Mode Countinggraph
Settingforinhibit counting
(CP1:H changestoL)
Releasecounting inhibit
(CP1:LchangestoH)
CP1:Countinginput
CP2:When n=settingvalue ,
inhibit countinginput
(thecountinginput islimittedbyCP1)
When CP1set toL ,
Settingforinhibit counting(CP2:Lset toH)
Releasecounting inhibit(CP2:H set toL)
CP2:Countinginput
CP1:When n=setting value,
inhibit countinginput
(thecountinginput islimittedbyCP2)
When CP2set toH,
Settingforcounting inhibit
(CP1:H changestoL)
Reseasecounting inhibit
(CP1:LchangestoH)
*WhenoutputfromphaseAandphaseBof encoderinputtoCP1andCP2, pleasesetphasedifferencemodeDofthecounter
Sign Input type
H
L
Voltageinput(PNP)
5-30VDC
0-2VDC
No-voltageinput(NPN)
Shortcircuit
Open circuit
B
(Up/Down-A)
Orderinput
C
(Up/Down-B)
separateinput
D
(Up/Down-C)
Phasedifferenceinput
CP1
CP2
CP1
CP2
CP1
CP2
CP1
CP2
CP1
CP2
CP1
CP2
B :
Counting
Nocounting
Remark
Counting
Counting
Counting
Counting
Counting
Nocounting
Nocounting
When phaseA phaseBofencoder
connect withCP1 CP2, thisfunction
couldbe used
*A :Abovethe widthof minsignal Abovethe halfof minsignalwidth

KKCQE01-7
Inputmode
Up Down
F
N
C
R
K
P
Q
A
10.Output action mode of counter
SV2
SV1
Display
OUT1 output
OUT2 output
0
SV2
SV1
Display
OUT1 output
OUT2 output
0
999999
SV2
SV1
Display
OUT1 output
OUT2 output
0
999999
SV2
SV1
OUT1
OUT2
Reset
Display
0
999999
SV2
SV1
OUT1
OUT2
Reset
Display
0
999999
SV2
SV1
OUT1
OUT2
0
999999
SV2
SV1
OUT1
OUT2
Reset
Display
0
SV2
SV1
Display
OUT1 output
OUT2 output
0
Action forcounting/timingwhen it
reachestothe setting value
Displaykeepsup ordown,
output maintaintillreset signalinput
Bothdisplayandoutput maintaintill
reset signalinput .
Reset
Display
Displayvalereturntothebeginning
statusautomatically,outputwon t return
tothe beginninguntillit reachestothe
setteddelaytime
(Output action isrepeated)
Bothdisplayvalueand output maintain
tillit reachestothe setteddelaytime
thenreturntothe beginningstatus.
(Output action isrepeated)
Displayvalue keepsupordowntill
reset signalinput,output won t returnto
thebeginning statusuntilit reaches
thesetted delaytime .
(Output action isrepeated)
Displayvalue maintainstillthe delaytime
output , then displaythevalueof next
round.(Counting/Timingof next round
startsfromthe beginning valueduring
thedelaytime)
(Output action isrepeated)
Displayvalue and outputof OUT1keep
tillresetsignalinput .OUT2returntothe
beginningstatuswhen it reachesto
theoutput delaytime.
Reset
999999
Reset
Reset
999999
999999
Reset
Displayvaluekeepupordown
duringtheoutput delaytime,
whenitcomestothesetteddelay
time,boththedisplayvalueand
outputwillreturntothebeginning
status.
(Output action isrepeated)

13
.
Dimension(mm)
11
.
Inputconnection
12
.
Connecting Drawing
+12V
5.4kΩ
Tothe internalcircuit
OV
(CQSeries)
Counting speed:setting to1or30cps(counter)
Counter/Timer
⑵Contactsconnectingin
11 +12V
5.4kΩ
Tothe internalcircuit
OV
(NPNNo-voltage input) (CQSerise)
1、Input logic:No-voltageinput(NPN)
Counter/Timer
Sensor
⑴Solidstaterelayinput
Standardsnesor:NPNoutputsensor
+12V
5.4kΩ
Tothe internalcircuit
OV
(CQSeries)
Countingspeed:setto1or30cps(counter)
Counter/Timer
⑵Contcatsconnectingin
+12V
5.4kΩ
Totheinternalcircuit
OV
(PNPvoltageinput) (CQSeries)
2、Input logic:voltageinput(PNP)
Counter/Timer
Sensor
⑴Solidstaterelayinput
Standardsensor:PNPoutput sensor
※
※
※
※
KKCQE01-8
10
11
10
11
10
11
10
Note:Please subject totheconnecting drawingon theactual meter if any changes
←
←
72
←
←
←
←
32
45
67.5
+0.8
-0
67.5
+0.8
-0
CQ7
←
←
68
67
72
←
←
48
48
45
←
←
←
←
30
45
+0.5
-0
45
+0.5
-0
CQ4
←
←
45
68
5
4
2
1
CP1
+12VDC
GND
CP2
RESET
100mA
100-240VAC
50/60Hz
POWER
OUT2
3
10
9
8
7
6
12
11
OUT1
CQ4seriescounter/timer
8
8
6
5
3
2
1
CP1
+12VDC
GND
CP2
PAUSE
RESET
100mA
100-240VAC
50/60Hz
POWER
OUT1
OUT2
14 7
4
13
12
11
10
9
CQ7seriescounter/timer
This manual suits for next models
4
Table of contents
Popular Cash Counter manuals by other brands

Nautilus Hyosung
Nautilus Hyosung MONiMAX7600TA installation manual

MZ electronic
MZ electronic EV030-Radio Instructions for use

PCE Health and Fitness
PCE Health and Fitness PCE-MPC 10 manual

DS Produkte
DS Produkte AP2110 instructions

Alphasense
Alphasense OPC-N2 user manual

Seedburo