manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Qlight
  6. •
  7. Horn
  8. •
  9. Qlight SHDLR User manual

Qlight SHDLR User manual

This manual suits for next models

3

Other Qlight Horn manuals

Qlight QWH35T-TI User manual

Qlight

Qlight QWH35T-TI User manual

Qlight QWH35T User manual

Qlight

Qlight QWH35T User manual

Qlight SRN Operator's manual

Qlight

Qlight SRN Operator's manual

Qlight SN-1 User manual

Qlight

Qlight SN-1 User manual

Qlight SEHN25 User manual

Qlight

Qlight SEHN25 User manual

Qlight SN-1 User manual

Qlight

Qlight SN-1 User manual

Qlight SANA200 User manual

Qlight

Qlight SANA200 User manual

Qlight QWH35 User manual

Qlight

Qlight QWH35 User manual

Popular Horn manuals by other brands

Klenn Air Horns JL-JK-OBA installation manual

Klenn Air Horns

Klenn Air Horns JL-JK-OBA installation manual

Vixen Horns VXO8350 installation guide

Vixen Horns

Vixen Horns VXO8350 installation guide

Elk Products 45 user manual

Elk Products

Elk Products 45 user manual

Cooper Wheelock DB3 Series specification

Cooper Wheelock

Cooper Wheelock DB3 Series specification

Altec Lansing 811B HF HORN manual

Altec Lansing

Altec Lansing 811B HF HORN manual

RF Elements UltraHorn CC Series quick start guide

RF Elements

RF Elements UltraHorn CC Series quick start guide

Edwards Signaling 869DSTR-G1 Series Installation sheet

Edwards Signaling

Edwards Signaling 869DSTR-G1 Series Installation sheet

Valcom V-1050C user manual

Valcom

Valcom V-1050C user manual

Valcom V-1030C user guide

Valcom

Valcom V-1030C user guide

Valcom VIP-130AL-SA quick start guide

Valcom

Valcom VIP-130AL-SA quick start guide

Toa LE-M124 Specifications

Toa

Toa LE-M124 Specifications

AUSTRALIAN MONITOR MH30 brochure

AUSTRALIAN MONITOR

AUSTRALIAN MONITOR MH30 brochure

Valcom V-1069A datasheet

Valcom

Valcom V-1069A datasheet

Valcom V-9947A quick start guide

Valcom

Valcom V-9947A quick start guide

Vixen Horns VXO8805/3311C installation guide

Vixen Horns

Vixen Horns VXO8805/3311C installation guide

Federal Signal Corporation 350 Installation and maintenance instructions

Federal Signal Corporation

Federal Signal Corporation 350 Installation and maintenance instructions

Electro-Voice MH4020AC Specifications

Electro-Voice

Electro-Voice MH4020AC Specifications

Dynacord 18" Full-W Vented Bass Horn alpha B6 Specifications

Dynacord

Dynacord 18" Full-W Vented Bass Horn alpha B6 Specifications

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

5020
66
118
HORN
1
Ordering Specications
Heavy-Duty LED Revolving Warning Light & Electric Horn Combination for
Vessels and Heavy Industry Applications
SHDLR/ SHD2LR
SHDLR
-
WA
-
24
-
R
[Model number]
[Sound]
[Voltage] [Color]
| |
| |
• SHDLR
• SHD2LR
• SHDLRP
• SHD2LRP
• WS-Warning sounds
• WP-Special warning sounds
• WM-Melodies
• WA-Alarms
• WV-Customizable sounds
• 12 - DC12V
• 24 - DC24V
• 110 - AC110V
• 220 - AC220V
R-Red
A-Amber
G-Green
B-Blue
Please scan the QR code for more
detailed product information.
www.qlight.com
Thank you for purchasing Qlight’s products. Please read this user manual
carefully prior to installation and operation to ensure safe and correct use.
1. Please remove any objects that can interrupt ventilation around the product.
2. Please turn o-• the power of the product immediately if it fails to operate properly.
3. Carefully wire the product according to each product’s speci¿cation.
4. Please be careful in preventing chemicals such as thinner, benzene, etc. in contact with the surface of the product.
5. Do not apply excessive force/impact to the product.
6. Failure to follow any of the instructions above may cause malfunction or damage to the product, ¿re, and electric shock.
Precautions for Correct Use
Failure to follow the proper instructions may cause damage to property, the product, or malfunction of the product
that would void the warranty.
Precautions for Safety
Failure to follow the instructions below may cause a loss of life or serious physical injury.
1. During wiring or maintenance, please completely turn o-• the power of the product. (Failure to follow this may lead to an electric shock.)
2. Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection
    ratings indicated for each product. (Failure to follow these instructions may cause a ¿re to the product, electric shock, physical injury,
    malfunction or damage to the product.)
3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point. (Failure to
    follow these instructions may lead to ¿re, electric shock, or product damage.)
4. Please apply the correct voltage to the product. (Failure to follow these instructions may lead to ¿re, electric shock, or product damage.)
5. When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device. (Failure to
    follow this may cause damage to property, ¿re, electric shock and loss of life.)
Product Specications
• Protection rating : IP66
• Ambient operating temperature : -30°C to +50°C
Model number Voltage Current Sound pattern and volume Certi¿cate Weight Color
SHDLR
SHDLRP
DC12V
2.633A
• WS-5 Warning Sounds : Max.114dB
• WP-Special warning sounds : Max.114dB
• WM-5 Melodies : Max.110dB
• WA-5 Alarms : Max.114dB
• WV-5 Customizable sounds : 108-113dB
• SHDLR
DC-3.21kg AC-3.91kg
• SHDLRP
DC-3.46kg AC-4.16kg
R-Red
A-Amber
G-Green
B-Blue
DC24V
1.288A
AC110V
0.308A
AC220V
0.154A
SHD2LR
SHD2LRP
DC12V
4.844A
• WS-5 Warning Sounds : Max.114dBx2
• WP-Special warning sounds : Max.114dBx2
• WM-5 Melodies : Max.110dBx2
• WA-5 Alarms : Max.114dBx2
• WV-5 Customizable sounds : 108-113dBx2
-
• SHD2LR
DC-4.26kg AC-4.97kg
• SHD2LRP
DC-4.51kg AC-5.22kg
DC24V
2.555A
AC110V
0.535A
AC220V
0.267A
※CE compliant : DC24V, AC220V
※Max. built-in volume feature is based on WS, WP-Ch1 / WM-Ch4 / WA-Ch4.
※ In case of customized WV 5 tone type, there may be di-•erence of volume
     depending on user’s audio ¿le type
2
SHDLR/ SHDLRP SHD2LR/ SHD2LRP
Dimensions
(Units : mm)
※ *(227) represents without protection cage.
Volume Adjustment
• The volume output of this product
is adjustable.
• Turn the volume dial clockwise to
increase the volume, and
turn counter clockwise to decrease
the volume.
• There will be no sound when the
dial is put at MIN.
Volume Dial
VOL.
MIN.MAX.
Wiring Instructions for LC Type
Sound Setting - Select using the switch inside of the unit.
• LC type product with exposed sound selection signal line is
avaliable upon request. Please refer to the diagram below for
wiring.
SHDLR/ SHDLRP-DC/AC
SHD2LR/ SHD2LRP-DC/AC
134
152
136 136
359
134
152
116
237
136 40
263
263 359
* (227)
116
237
* (227)
87
121
87
121
PROTECTION CAGE
CABLE ENTRY
1/2"PF
PROTECTION CAGE
CABLE ENTRY
1/2"PF
Ø135 Ø135
Ø117
Ø117
4-Ø8.5 FITTING HOLES 4-Ø8.5 FITTING HOLES
• External power line - UL1015 AWG18(0.75sq) x 2C 400mm
• External signal line - UL1007 AWG22(0.3sq) 400mm
Category Sound
pattern Channel Sound tone volume
(Max.)
WS
5 Warning
sounds
Ch1 Fire.A-ANG
Max.
114dB
Ch2 Emergency WA-U
Ch3 Ambulance PI-PO
Ch4 Machinery Fault
Ch5 High Expansion
WP
5
Special
Warning
sounds
Ch1 Fire.A-ANG
Max.
114dB
Ch2 Abandon Alarm
Ch3 Machinery Fault
Ch4 High Expansion
Ch5 7 Short PI. / 1 Long
WM
5 Melodies
Ch1 Sweet Home
Max.
110dB
Ch2 For Elise
Ch3 Cuckoo's Waltz
Ch4 Piano Sonata
Ch5 Turkish March
WA
5Alarms
Ch1 Beep Intermittent
Max.
114dB
Ch2 Door Chime
Ch3 Phone Ring
Ch4 PI.PI.PI Short
Ch5 Tripping Beat
WV
5
Customiz-
able sounds
Ch1-Ch5
Available upon request
(customized voice type)
108-
113dB
■ Sound Type by Group
• Standard unit has 5 built-in sound tones.
   Select di-•erent built-in sounds using the sound setting switch.
• For standard type, once the unit is powered on, light and sound
are working simultaneously.
• For tone group settings, refer to the website [Customer Support] -
[Technical Data] - [Types of Tone and Combination of General
Tone products].
ON
ON
1 2 3
1 2 3 4 5
DP
sound setting switch
Sound group switch
channel selection
switch
※ In case of customized WV 5 tone type, there may be di-•erence of
     volume depending on user’s audio ¿le type.
Ch1
Ch2
Ch3
Ch4
Ch5
Ch1
Ch2
Ch3
Ch4
Ch5
EXTERNAL CONTACT
EXTERNAL TRASISTOR-NPN
Common
Common
Power
Power
Fuse
Fuse
Red
Amber
Green
Blue
White
White or Red
Black
Black
Red
Amber
Green
Blue
White
White or Red
Black
Black
3
4-Ø9 HOLES
134
87
SHDLR SHD2LR
Parts Denition/ Installation
•
First, machine holes on the mounting surface.
•
The mounting hole of this product is 8.5mm in diameter.
•
When machining taps, fasten the bolt through the mounting hole of the bracket.
• When machining holes, insert the bolt through the hole of the product,
and tighten the nut from the opposite side of the mounting surface.
•
When assembling using bolt and nut, please make sure to use at  washer and spring washer.
Horn
Lens
(PC)
Housing
(Al)
Protection cage
(STS316L)
Installation Environment and Protection Rating
• This product is designed for use with protection rating of IP66.
• If the product is installed in locations that subject it to excessive dust or water other than the designated IP protection rating
   indicated(IP66), it may cause malfunction or damage to the product.
• In case of outdoor applications, install the product in the upright position. Do not install the product horizontal or upside-
down positions where water can potentially penetrate into the product and impact it’s operation.
• For further information, please visit our website (www.qlight.com).
Mounting Hole Specications/Light bulb Replacement lnstructions
•
Machine holes on the mounting surface referring to the diagram below.
①
Terminal Box Wiring Instructions
• Terminal block is located inside of the product. Unscrew the 4 bolts located in the upper
body to get rid of the upper lighting element of the unit.
• Please apply fork (U-type) or ring (O-type) locking spade terminal at naked tip of the
wire for secure connection.
• Please wire the power line to terminal
①
• For AC type products, wire regardless of polarity.
• For DC type products, wire terminal of black line to (-) polarity.
※Applicable cable range : AWG16-AWG22
Qlight Co., Ltd. www.qlight.com | [email protected]
Head O-ce | Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea
                       Tel. +82-2-2679-6152(Toll free. +82-80-328-2222)  Fax. +82-2-2679-6154
Factory | 185-25, Mukbang-ro, Sangdong-myeon, Gimhae-si, Gyeongsangnamdo, Korea Tel. +82-55-328-1111(Toll free. +82-80-328-1111)
Qlight Overseas Sales Dept |
704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel : +82-51-620-4100
Qlight Public Relations & Marketing Team O-ce | 704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel. +82-51-245-0017
SHANGHAI Qlight Electronic Co., Ltd. www.qlight.com www.qlightcn.com | [email protected]
China Factory/ Shanghai Sales O-ce | #Room 333 Building B, #11, Lane 450, Zhenda Road, Baoshan District, Shanghai, China
Tel. +86
-
21
-
6651
-
7100 Fax. +86
-
21
-
6315
-
3929
China Factory Site 2 (Qidong) | #33, Haiyan Road, Qidong High-tech Industrial Development Zone, Qidong, Jiangsu Province, China  
Tel +86
-
513
-
8384
-
9999 Fax +86
-
513
-
8384
-
9910
Product Operation Inquiry / Customer Support +82-51-620-4100
You can expect prompt service if you have exact information such as model name, symptom, telephone number and address.
※ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
    RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Head office : Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea ( Postal Code : 08507)
Factory : 185-25, Mukbang-Ro, Sangdong-Myeon, Gimhae-Si, Gyeongsangnam-Do, Korea ( Postal Code : 50805)
For your safety
Speci¿cation and dimensions listed in this catalogue subject to change without notice for product quality improvement.
The newest product information is available on our website.(www.qlight.com)
Please read the instruction manual attached to the product carefully before installation and use.
www.qlight.com