Qlight SHDLR User manual

5020
66
118
HORN
1
Ordering Specications
Heavy-Duty LED Revolving Warning Light & Electric Horn Combination for
Vessels and Heavy Industry Applications
SHDLR/ SHD2LR
SHDLR
-
WA
-
24
-
R
[Model number]
[Sound]
[Voltage] [Color]
| |
| |
• SHDLR
• SHD2LR
• SHDLRP
• SHD2LRP
• WS-Warning sounds
• WP-Special warning sounds
• WM-Melodies
• WA-Alarms
• WV-Customizable sounds
• 12 - DC12V
• 24 - DC24V
• 110 - AC110V
• 220 - AC220V
R-Red
A-Amber
G-Green
B-Blue
Please scan the QR code for more
detailed product information.
www.qlight.com
Thank you for purchasing Qlight’s products. Please read this user manual
carefully prior to installation and operation to ensure safe and correct use.
1. Please remove any objects that can interrupt ventilation around the product.
2. Please turn o-• the power of the product immediately if it fails to operate properly.
3. Carefully wire the product according to each product’s speci¿cation.
4. Please be careful in preventing chemicals such as thinner, benzene, etc. in contact with the surface of the product.
5. Do not apply excessive force/impact to the product.
6. Failure to follow any of the instructions above may cause malfunction or damage to the product, ¿re, and electric shock.
Precautions for Correct Use
Failure to follow the proper instructions may cause damage to property, the product, or malfunction of the product
that would void the warranty.
Precautions for Safety
Failure to follow the instructions below may cause a loss of life or serious physical injury.
1. During wiring or maintenance, please completely turn o-• the power of the product. (Failure to follow this may lead to an electric shock.)
2. Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection
ratings indicated for each product. (Failure to follow these instructions may cause a ¿re to the product, electric shock, physical injury,
malfunction or damage to the product.)
3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point. (Failure to
follow these instructions may lead to ¿re, electric shock, or product damage.)
4. Please apply the correct voltage to the product. (Failure to follow these instructions may lead to ¿re, electric shock, or product damage.)
5. When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device. (Failure to
follow this may cause damage to property, ¿re, electric shock and loss of life.)
Product Specications
• Protection rating : IP66
• Ambient operating temperature : -30°C to +50°C
Model number Voltage Current Sound pattern and volume Certi¿cate Weight Color
SHDLR
SHDLRP
DC12V
2.633A
• WS-5 Warning Sounds : Max.114dB
• WP-Special warning sounds : Max.114dB
• WM-5 Melodies : Max.110dB
• WA-5 Alarms : Max.114dB
• WV-5 Customizable sounds : 108-113dB
• SHDLR
DC-3.21kg AC-3.91kg
• SHDLRP
DC-3.46kg AC-4.16kg
R-Red
A-Amber
G-Green
B-Blue
DC24V
1.288A
AC110V
0.308A
AC220V
0.154A
SHD2LR
SHD2LRP
DC12V
4.844A
• WS-5 Warning Sounds : Max.114dBx2
• WP-Special warning sounds : Max.114dBx2
• WM-5 Melodies : Max.110dBx2
• WA-5 Alarms : Max.114dBx2
• WV-5 Customizable sounds : 108-113dBx2
-
• SHD2LR
DC-4.26kg AC-4.97kg
• SHD2LRP
DC-4.51kg AC-5.22kg
DC24V
2.555A
AC110V
0.535A
AC220V
0.267A
※CE compliant : DC24V, AC220V
※Max. built-in volume feature is based on WS, WP-Ch1 / WM-Ch4 / WA-Ch4.
※ In case of customized WV 5 tone type, there may be di-•erence of volume
depending on user’s audio ¿le type

2
SHDLR/ SHDLRP SHD2LR/ SHD2LRP
Dimensions
(Units : mm)
※ *(227) represents without protection cage.
Volume Adjustment
• The volume output of this product
is adjustable.
• Turn the volume dial clockwise to
increase the volume, and
turn counter clockwise to decrease
the volume.
• There will be no sound when the
dial is put at MIN.
Volume Dial
VOL.
MIN.MAX.
Wiring Instructions for LC Type
Sound Setting - Select using the switch inside of the unit.
• LC type product with exposed sound selection signal line is
avaliable upon request. Please refer to the diagram below for
wiring.
SHDLR/ SHDLRP-DC/AC
SHD2LR/ SHD2LRP-DC/AC
134
152
136 136
359
134
152
116
237
136 40
263
263 359
* (227)
116
237
* (227)
87
121
87
121
PROTECTION CAGE
CABLE ENTRY
1/2"PF
PROTECTION CAGE
CABLE ENTRY
1/2"PF
Ø135 Ø135
Ø117
Ø117
4-Ø8.5 FITTING HOLES 4-Ø8.5 FITTING HOLES
• External power line - UL1015 AWG18(0.75sq) x 2C 400mm
• External signal line - UL1007 AWG22(0.3sq) 400mm
Category Sound
pattern Channel Sound tone volume
(Max.)
WS
5 Warning
sounds
Ch1 Fire.A-ANG
Max.
114dB
Ch2 Emergency WA-U
Ch3 Ambulance PI-PO
Ch4 Machinery Fault
Ch5 High Expansion
WP
5
Special
Warning
sounds
Ch1 Fire.A-ANG
Max.
114dB
Ch2 Abandon Alarm
Ch3 Machinery Fault
Ch4 High Expansion
Ch5 7 Short PI. / 1 Long
WM
5 Melodies
Ch1 Sweet Home
Max.
110dB
Ch2 For Elise
Ch3 Cuckoo's Waltz
Ch4 Piano Sonata
Ch5 Turkish March
WA
5Alarms
Ch1 Beep Intermittent
Max.
114dB
Ch2 Door Chime
Ch3 Phone Ring
Ch4 PI.PI.PI Short
Ch5 Tripping Beat
WV
5
Customiz-
able sounds
Ch1-Ch5
Available upon request
(customized voice type)
108-
113dB
■ Sound Type by Group
• Standard unit has 5 built-in sound tones.
Select di-•erent built-in sounds using the sound setting switch.
• For standard type, once the unit is powered on, light and sound
are working simultaneously.
• For tone group settings, refer to the website [Customer Support] -
[Technical Data] - [Types of Tone and Combination of General
Tone products].
ON
ON
1 2 3
1 2 3 4 5
DP
sound setting switch
Sound group switch
channel selection
switch
※ In case of customized WV 5 tone type, there may be di-•erence of
volume depending on user’s audio ¿le type.
Ch1
Ch2
Ch3
Ch4
Ch5
Ch1
Ch2
Ch3
Ch4
Ch5
EXTERNAL CONTACT
EXTERNAL TRASISTOR-NPN
Common
Common
Power
Power
Fuse
Fuse
Red
Amber
Green
Blue
White
White or Red
Black
Black
Red
Amber
Green
Blue
White
White or Red
Black
Black

3
4-Ø9 HOLES
134
87
SHDLR SHD2LR
Parts Denition/ Installation
•
First, machine holes on the mounting surface.
•
The mounting hole of this product is 8.5mm in diameter.
•
When machining taps, fasten the bolt through the mounting hole of the bracket.
• When machining holes, insert the bolt through the hole of the product,
and tighten the nut from the opposite side of the mounting surface.
•
When assembling using bolt and nut, please make sure to use at washer and spring washer.
Horn
Lens
(PC)
Housing
(Al)
Protection cage
(STS316L)
Installation Environment and Protection Rating
• This product is designed for use with protection rating of IP66.
• If the product is installed in locations that subject it to excessive dust or water other than the designated IP protection rating
indicated(IP66), it may cause malfunction or damage to the product.
• In case of outdoor applications, install the product in the upright position. Do not install the product horizontal or upside-
down positions where water can potentially penetrate into the product and impact it’s operation.
• For further information, please visit our website (www.qlight.com).
Mounting Hole Specications/Light bulb Replacement lnstructions
•
Machine holes on the mounting surface referring to the diagram below.
①
Terminal Box Wiring Instructions
• Terminal block is located inside of the product. Unscrew the 4 bolts located in the upper
body to get rid of the upper lighting element of the unit.
• Please apply fork (U-type) or ring (O-type) locking spade terminal at naked tip of the
wire for secure connection.
• Please wire the power line to terminal
①
• For AC type products, wire regardless of polarity.
• For DC type products, wire terminal of black line to (-) polarity.
※Applicable cable range : AWG16-AWG22

Head O-ce | Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea
Tel. +82-2-2679-6152(Toll free. +82-80-328-2222) Fax. +82-2-2679-6154
Factory | 185-25, Mukbang-ro, Sangdong-myeon, Gimhae-si, Gyeongsangnamdo, Korea Tel. +82-55-328-1111(Toll free. +82-80-328-1111)
Qlight Overseas Sales Dept |
704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel : +82-51-620-4100
Qlight Public Relations & Marketing Team O-ce | 704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel. +82-51-245-0017
China Factory/ Shanghai Sales O-ce | #Room 333 Building B, #11, Lane 450, Zhenda Road, Baoshan District, Shanghai, China
Tel. +86
-
21
-
6651
-
7100 Fax. +86
-
21
-
6315
-
3929
China Factory Site 2 (Qidong) | #33, Haiyan Road, Qidong High-tech Industrial Development Zone, Qidong, Jiangsu Province, China
Tel +86
-
513
-
8384
-
9999 Fax +86
-
513
-
8384
-
9910
Product Operation Inquiry / Customer Support +82-51-620-4100
You can expect prompt service if you have exact information such as model name, symptom, telephone number and address.
※ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Head office : Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea ( Postal Code : 08507)
Factory : 185-25, Mukbang-Ro, Sangdong-Myeon, Gimhae-Si, Gyeongsangnam-Do, Korea ( Postal Code : 50805)
For your safety
Speci¿cation and dimensions listed in this catalogue subject to change without notice for product quality improvement.
The newest product information is available on our website.(www.qlight.com)
Please read the instruction manual attached to the product carefully before installation and use.
www.qlight.com
EN - SHDLR - 2310A