Quadra-Fire DISCOVERY-II-C Instruction Manual

17033-353G 08/21
NOTICE: DO NOT DISCARD THIS MANUAL
R
DISCOVERY II WOOD APPLIANCE
AUTOMATIC COMBUSTION
CONTROL (ACC)
MODEL NUMBER:
DISCOVERY-II-C
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
WARNING
Hot glass and appliance will cause burns.
• Do not touch glass until it is cooled
• Use leather gloves when reloading fuel
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room
as appliance.
• Alert children and adults to hazards of
high temperatures
• High temperatures may ignite clothing or other
ammable materials.
• Keep clothing, furniture, draperies and other
ammable materials away.
WARNING
Fire Risk.
For use with solid wood fuel only.
Other fuels may over-re and generate
poisonous gases (i.e. carbon monoxide).
WARNING
If the information in these instructions is
not followed exactly, a re could result
causing property damage, personal injury,
or death.
• Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any
other appliance.
• Do not over-re - If appliance or chimney connector
glows, you are over-ring. Over-ring will void
your warranty.
• Comply with all minimum clearances to combustibles
as specied.
Failure to comply may cause house re.
NOTE: To obtain a French translation of this
manual, please contact your dealer or visit
www.quadrare.com
REMARQUE : Pour obtenir une traduction française de
ce manuel, s’il vous plaît contacter votre
revendeur ou visitez www.quadrare.com
Owner’s Manual
Operation & Care
INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
Contact your dealer with questions on installation, operation, or service.
Installation and service of this appliance should be performed by
qualified personnel. Hearth & Home Technologies recommends
HHT Factory Trained or NFI certified professionals.

27033-353G 08/21
1 7033-354 SERIAL RATING PLATE 1
7.75
9.5
LISTED ROOM APPLIANCE, SOLID FUEL TYPE. ALSO FOR USE IN MOBILE HOMES. (UM) 84 HUD . "For Use with
Solid Wood Fuel Only" / APPAREIL DE CHAUFFAGE DE PIÈCE, DE TYPE DE COMBUSTIBLE SOLIDE, POUR USAGE
DANS LES MAISONS MOBILES. (UM) 84 HUD. "Pour Usage Avec Bois Solide Seulement"
PREVENT HOUSE FIRES / PRÉVENTION DES FEUX DE MAISON
Install and use only in accordance with manufacturer's installation and operating instructions. Contact local building or fire
officials about restrictions and installation inspections in your area. Do not obstruct the space beneath appliance. WARNING
- For Mobile Homes: Do not install in a sleeping room. An outside combustion air inlet must be provided and unrestricted
while unit is in use. The structural integrity of the mobile home floor, ceiling and walls must be maintained. The appliance
needs to be properly grounded to the frame of the mobile home. Components required for mobile home installation: Outside
Air Kit, Part Number OAK-ACC. Refer to manufacturer's instructions and local codes for precautions required for passing
chimney through a combustible wall or ceiling and maximum offsets. Inspect and clean chimney frequently - Under Certain
Conditions of Use, Creosote Buildup May Occur Rapidly. Do not connect this unit to a chimney serving another appliance.
Optional Blower, Part BK-ACC. Electrical Rating: 115 VAC, 1.2 Amps, 60 Hz. Route power cord away from unit. Do not route
cord under or in front of appliance. DANGER: Risk of electrical shock. Disconnect power supply before servicing. Replace
glass only with 5mm ceramic available from your dealer. Do not use grate or elevate fire. Build wood fire directly on hearth.
Do not overfire - if appliance or chimney connector glows, you are overfiring. Operate only with the fuel loading door closed.
Open only to add fuel to the fire. / Installez et utilisez en accord avec les instructions d'installation et d'opération du fabricant.
Contactez le bureau de la construction ou le bureau des incendies au sujet des restrictions et des inspections d'installation
dans votre voisinage. Ne pas obstruez l'espace en dessous de l'appareil. AVIS - Pour Les Maisons Mobiles : Ne pas
installer dans une chambre à coucher. Un tuyau extérieur de combustion d'air doit être installé et ne doit pas être obstrué
lorsque l'appareil est en usage. La structure intégrale du plancher, du plafond et des murs de la maison mobile doit être
maintenue intacte. L'appareil de chauffage doit être fixé à la charpente de la maison mobile. Les composants requis pour
l'installation des maisons mobiles: Assemblage d'air extérieur, Numéro de Pièce OAK-ACC. Référez vous aux instructions
du fabricant et des codes locaux pour les précautions requises pour passer une cheminée à travers un mur ou un plafond
combustibles, et les compensations maximums. Inspectez et nettoyez la cheminée fréquemment. Sous certaines conditions,
il se peut que la créosote s'accumule rapidement. Ne pas connecter cet appareil à une cheminée servant un autre appareil.
tVentilateur Optionnel, Pièce BK-ACC. Puissance Électrique: 115 VAC, 1.2 Amps, 60 Hz. Éloignez le fil électrique de
l'appareil. Ne pas faire passer le fil électrique au dessus ou en dessous de l'appareil. DANGER : Il y a risque de décharge
électrique. Déconnectez le fil électrique de la prise de contact avant le service. Remplacez la vitre seulement avec une vitre
céramique de 5 mm disponible chez votre fournisseur. N'élevez pas le feu. Bâtissez le feu de bois directement sur l'âtre. Ne
pas surchauffer. Si l'appareil de chauffage ou le tuyau de cheminée rougissent, vous surchauffez. Opérez l'appareil
seulement lorsque la porte de chargement est fermée. Ouvrez la porte seulement lorsque vous devez ajouter des
combustibles dans le feu.
CAUTION
:
U.S. ENVIRONMENTAL PROTECTION AGENCY
Certified to comply with 2020 particulate emission standards using crib wood at 1.9 G/HR
This wood heater needs periodic inspection and repair for proper operation. Consult the
owner’s manual for further information. It is against federal regulations to operate this wood
heater in a manner inconsistent with the operating instructions in the owner’s manual.
2021 2022
Dec.Nov.Oct.Sept.Aug.JulyJuneMayApr.Mar.Feb.Jan.
2023
FLOOR PROTECTION:
Floor protector must be a 3/8 (9.5mm) inch min. thickness,
non-combustible material or equivalent, extending beneath
heater and to front/sides/rear as indicated on the diagram
below. Exception: Non-combustible floor protections must
extend beneath the flue pipe when installed with horizontal
venting and extend 2 inches (51mm) beyond each side.
HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS. KEEP FURNISHINGS
AND OTHER COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS.
VENT SPECIFICATIONS: / SPÉCIFICATIONS DE LA VENTILATION :
SINGLE WALL: Six inch (6 inches) (152mm) diameter, minimum 24 MSG black or blued steel connector pipe, with a listed factory-built UL103HT* Class "A" chimney, suitable for use with solid fuels, or a masonry chimney, and the referenced clearances.
/ MUR SIMPLE : De six (6 inches) (152mm) de diamètre le connecteur de conduit de minimum d'acier noir ou bleu de minimum de 24MSG, avec une cheminée bâtit en usine UL103HT* de Classe "A", adéquate pour usage avec les combustions solides,
ou une cheminée de briques, avec espaces libres référés.
DOUBLE WALL: Six inch (6 inches) (152mm) diameter, listed double wall air insulated connector pipe with listed factory-built UL103HT* Class "A" chimney, or a masonry chimney and the referenced clearances. / MUR DOUBLE : De six (6 inches)
(152mm) de diamètre, le connecteur du conduit d'air isolé pour mur double avec une cheminée bâtit en usine UL103HT* de Classe "A:, ou une cheminée de briques, avec espaces libres alloués.
MOBILE HOME: Use double wall pipe by Dura-Vent DVL, Selkirk Metalbestos DS or Security DL double wall connector pipe. Must be equipped with a spark arrestor. Apply double wall clearances below when installing unit. / MAISON MOBILE : Utiliser
un conduit de mur double par Dura-Vent DVL, Selkirk Metalbestos DS ou Security DL. Doit être équipé d'un arrêt d'étincelle. Utiliser les espaces libres pour mur double comme mentionné ci-bas.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS: In Inches & (Millimeters) / ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES:En Pouces & (millimètres)
NOTE: All "A" , "C" and "F" Dimensions are to inside diameter of the flue collar. / REMARQUE : Toutes les dimensions "A", "C", et "F" sont à partir du diamètre intérieur de l'entrée du conduit.
7033-354E
CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER DES
BRÛLURES À LA PEAU. GARDEZ LES MEUBLES ET LES MATÉRIAUX COMBUSTIBLES LOIN DE L'ESPACE DÉSIGNÉ DE L'APPAREIL. VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS
.
ATTENTION:
PROTECTION DU PLANCHER:
Le protecteur de plancher doit être d'un minimum de 3/8
inch (9.5mm) d'épaisseur, de matériel incombustible ou
équivalent, s'étendant du dessous de l'appareil de
chauffage à l'avant, aux cotés et à l'arrière comme indiqué
sur le diagramme suivant. Exception : Les protections
incombustibles du plancher doivent s'étendre en dessous
du conduit de cheminée lorsqu'installées avec une
ventilation à l'horizontale et s'étendre de 2 inches (51mm)
de chaque côté.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE
Manufactured by:
Fabriqué par :
CANADA
203mm (8")
203mm
(8")
203mm
(8")
457mm (18")
1243mm
(49")
minimum
1041mm (41") minimum
Made in U.S.A. of US and imported parts.
/ Fabriqué aux États-Unis-d’Amérique par
des pièces d’origine américaine et pièces
importées.
31M-ACC-C DISCOVERY-II-C
352 Mountain House Road,
Halifax, PA 17032
www.quadrafire.com
Serial No. / N° de série
HF
BARCODE LABEL
TESTED TO:/ TESTÉ À :
ASTM E2515, ASTM E2780, UL 1482-11 (R2015), ULC S627-00.
R
3100 ACC Series-C
Report / Rapport
0061WS066S
0061WS066E
16" from glass
8"
USA
Fuel loading door
Millennium 31-5/8" Min
39”
minimum
I
NSTALLATION: FULL VERTICAL OR HORIZONTAL WITH MINIMUM 2 FT VERTICAL OFF STOVE TOP / INSTALLATION : ENTIÈREMENT VERTICALE OU HORIZONTALE AVEC 609mm VERTICAL MINIMUM DU HAUT DU POÊLE
SINGLE WALL PIPE / CONDUIT DU MUR SIMPLE
A B C D E F G H
Discovery-II-C 18.25 (464) 11.75 (298) 28.5 (724) 16 (406) 8 (203) 20 (508) 48 (1220) 12 (305)
31M-ACC-C 18.25 (464) 11.75 (298) 28.5 (724) 16 (406) 8 (203) 20 (508) 48 (1220) 12 (305)
DOUBLE WALL PIPE /
CONDUIT DU MUR DOUBLE
Discovery-II-C 13.5 (343) 6.5 (165) 25 (635) 13 (330) 6.5 (165) 18.5 (470) 48 (1220) 9 (229)
31M-ACC-C 13.5 (343) 6.5 (165) 25 (635) 13 (330) 6.5 (165) 18.5 (470) 48 (1220) 9 (229)
INSTALLATION: 90° ELBOW OFF TOP OF STOVE THROUGH BACKWALL / INSTALLATION: 90° DU COURBURE AU DESSUS DE HAUT DU POÊLE A TRAVERS LE MUR ARRIÈRE
SINGLE WALL PIPE / CONDUIT DU MUR SIMPLE
Discovery-II-C 15 (381) 8.5 (216) 25 (635) 13 (330) 8 (203) 20 (508) 48 (1220) 12 (305)
31M-ACC-C 15 (381) 8.5 (216) 25 (635) 13 (330) 8 (203) 20 (508) 48 (1220) 12 (305)
DOUBLE WALL PIPE /
CONDUIT DU MUR DOUBLE
Discovery-II-C 11 (279) 4.5 (114) 20.5 (521) 8.5 (216) 6.5 (165) 18.5 (470) 48 (1220) 9 (229)
31M-ACC-C 11 (279) 4.5 (114) 20.5 (521) 8.5 (216) 6.5 (165) 18.5 (470) 48 (1220) 9 (229)
INSTALLATION: ALCOVE - Six inch (6 inches) (152mm) diameter listed DOUBLE WALL air insulated connector pipe with UL103 HT** listed factory-built Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a
spark arrestor.) Maximum depth of Alcove shall be no more than 48 inches (1219mm) and the referenced alcove clearances. /
INSTALLATION : ALCÔVE -
Six pouces (6 pouces) (152mm) de diamètre listé air isolé tuyau de
raccordement à double paroi avec UL103 HT ** cotée Classe usine construite "A" cheminée ou une cheminée de maçonnerie. (Mobile Home doit être équipé d' un pare-étincelles.) Profondeur maximale de Alcove ne doit pas être plus de
48 pouces (1219mm) et les dégagements en alcôve référencés
.
DOUBLE WALL PIPE / CONDUIT DU MUR DOUBLE
Discovery-II-C
14.75 (375) 8.25 (210) 26.5 (673) 14.5 (368) N/A N/A 48 (1220)
*
31M-ACC-C
14.75 (375) 8.25 (210) 26.5 (673) 14.5 (368) N/A N/A 48 (1220)
*
*In Canada must comply with Standard CAN/ULC-S629-M87 for the 650°C Factory-built chimney. / *Au Canada doit conformer a CAN/ULC-S629-M87 la norme pour 650°C cheminée bâtit en usine.
* SEE PIPE MANUFACTURERS CLEARANCES - NOT TESTED / VOIR LE FABRICANT POUR LES ESPACES LIBRES DES CONDUIT - PAS TESTÉ
90° OFF TOP
UP & OUT CEILING CLEARANCE
ESPACE LIBRE DU DESSUS DE
L'APPAREIL AU PLAFOND AVEC
90° DE COURBURE
STOVE TO CEILING CLEARANCE
ESPACE LIBRE DU POÊLEAU
PLAFOND
G
H
G
H
GA
B
ALCOVE SIDE VIEW /
VUE DE CÔTÉ DE
L'ALCÔVE
B
GA
ALCOVE TOP VIEW /
VUE DU HAUT DE
L'ALCÔVE
C
D
BACKWALL/SIDEWALL
MUR ARRIÈRE/MUR DE CÔTÉ
AB
C
D
CORNER INSTALLATION/
INSTALLATION DU COIN
E
F
E
F
SAMPLE
Serial
No.
Safety &
Emissions
Test
Report
Name
Test Lab &
Report No.
Mfg. Date
A. Sample of Serial Number / Safety Label
LOCATION: Back of appliance
NOTE: Clearances may only be reduced by means approved by the regulatory
authority having jurisdiction
and Welcome to the Quadra-Fire Family!
Model
Numbers

37033-353G 08/21
Quadra-Fire is a registered trademark of Hearth & Home Technologies.
TABLE OF CONTENTS
Safety Alert Key:
• DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.
• WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.
• CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
• NOTICE: Indicates practices which may cause damage to the appliance or to property.
A. Sample of Serial Number / Safety Label ........... 2
B. Warranty Policy .............................. 4
C. Quick Start Guide............................. 6
1 Listing and Code Approvals
A. Appliance Safety Certication ................... 7
B. Appliance Emissions Certication ................ 7
C. BTU & Efciency Specications.................. 7
D. Glass Specications........................... 8
E. Mobile Home Approved ........................ 8
F. Sleeping Room ............................... 8
G. California - Prop65............................ 8
2 Operating Instructions
A. Over-Firing Your Appliance ..................... 9
B. Wood Selection & Storage...................... 9
C. Burning Process.............................. 9
D. Air Controls ................................ 10
E. Using Burn Rate Air Control & ACC System ....... 11
F. Burn Rates and Operating Efciency ............. 12
G. Building A Fire .............................. 13
H. Blower Operating Instructions .................. 14
I. Opacity (Smoke) ............................. 14
J. Clear Space ................................ 15
K. Negative Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
L. Frequently Asked Questions.................... 16
3 Maintenance and Service
A. Quick Reference Maintenance Guide ............ 17
B. General Maintenance......................... 18
C. Correct Bafe & Blanket Placement.............. 20
4 Troubleshooting Guide ....................... 21
5 Service Part Replacement
A. Glass ..................................... 22
B. Firebrick ................................... 22
C. Snap Disc.................................. 23
D. Door Handle Assembly ....................... 23
E. Bafe ..................................... 24
F. Decorative Panel Removal & Installation . . . . . . . . . . 25
G. Tube Channel Assembly ...................... 26
6 Reference Materials
A. Service and Maintenance Log . . . . . . . . . . . . . . . . . . 27
B. Exploded View .............................. 29
C. Service Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
D. Accessories ................................ 33
= Contains updated information

47033-353G 08/21
Hearth & Home Technologies LLC
LIMITED LIFETIME WARRANTY
Hearth & Home Technologies LLC (“HHT”) extends the following warranty for HHT gas, wood, pellet and electric hearth appliances
(each a “Product” and collecvely, the “Product(s)”) and certain component parts set forth in the table below (“Component Part(s)”)
that are purchased from a HHT authorized dealer or distributor.
WARRANTY COVERAGE:
HHT warrants that the Products and their Component Parts will be free from defects in materials and workmanship for the applicable
period of Warranty coverage set forth in the table below (“Warranty Period”). If a Product or Component Parts are found to be
defecve in materials or workmanship during the applicable Warranty Period, HHT will, at its opon, repair the applicable Component
Part(s), replace the applicable Component Part(s), or refund the purchase price of the applicable Product(s). The maximum amount
recoverable under this Warranty is limited to the purchase price of the Product. This Warranty is transferable from the original purchaser
to subsequent owners, but the Warranty Period will not be extended in duraon or expanded in coverage for any such transfer. This
Warranty is subject to condions, exclusions, and limitaons as described below.
WARRANTY PERIOD:
Warranty coverage begins at the date of installaon. In the case of new home construcons, Warranty coverage begins on the date of
rst occupancy of the dwelling or six months aer the sale of the Product(s) by an independent, authorized HHT dealer or distributor,
whichever occurs earlier. However, the Warranty coverage shall commence no later than 24 months following the date of Product
shipment from HHT, regardless of the installaon or occupancy date.
The term “Lifeme” in the table below is dened as: 20 years from the beginning date of warranty coverage for gas appliances, and 10
years from the beginning date of warranty coverage for wood and pellet appliances. These me periods reect the minimum expected
useful lives of the designated Component Parts under normal operang condions.
Page 1 of 2
4021-645L 10/20
Component
Parts Labor Gas Pellet Wood Electric Venting Component Parts Covered by this Warranty
XAll parts except as covered by Warranty Conditions,
Warranty Exclusions, and Warranty Limitations listed
X X
Igniters, Auger Motors, Electronic Components, and
Glass
X
Electrical components limited to modules, remotes/wall
switches, valves, pilots, blowers, junction boxes, wire
harnesses, transformers and lights (excluding light bulbs)
X X Molded Refractory Panels, Glass Liners
XVent Free Burners, Vent Free Logs
X X Castings, Medallions and Baffles
6 years 3 years XCatalysts
7 years 3 years X X Manifold tubes, HHT Chimney and Terminations
10 years 1 year XBurners, logs and refractory
Limited
Lifetime 3 years XXX Firebox and heat exchanger, FlexBurn®System
(engine, inner cover, access cover and fireback)
1 Year None XXXXX All purchased replacement parts
Warranty Period HHT Manufactured Appliances and Venting
All parts including handles, external enameled
components and other material except as covered by
Warranty Conditions, Warranty Exclusions, and
Warranty Limitations listed
2 years
X1 Year X X X
2 Years
5 years 1 year
Firepots, burnpots, mechanical feeders/auger
assemblies
3 years X
B. Warranty Policy

57033-353G 08/21
WARRANTY CONDITIONS:
• Because HHT cannot control the quality of any Products sold by unauthorized sellers, this Warranty only covers Products that are
purchased through an HHT authorized dealer or distributor unless otherwise prohibited by law; a list of HHT authorized dealers
is available on the HHT branded websites.
• This Warranty is only valid while the applicable Product remains at the site of original installaon.
• This Warranty is only valid in the country in which the HHT authorized dealer or distributor that sold the applicable Product is
authorized to sell applicable Product.
• Contact your installing distributor or dealer for Warranty service. If the installing dealer or distributor is unable to provide
necessary parts, contact the nearest HHT authorized dealer or supplier. Addional service fees may apply if you are seeking
Warranty service from a dealer other than the dealer from whom you originally purchased the applicable Product.
• No HHT consumer should bear cost of warranty service or costs incurred while servicing warranty claims (i.e., travel, gas, or
mileage) when the service is performed within the terms of this Warranty. Check with your dealer or distributor in advance for
any costs to you when arranging a warranty call. Travel and shipping charges for parts are not covered by this Warranty.
WARRANTY EXCLUSIONS:
This Warranty does not cover the following:
• Changes in surface nishes as a result of normal use. As a heang appliance, some changes in color of interior and exterior surface
nishes may occur. This is not a aw and is not covered under the Warranty.
• Damage to printed, plated, or enameled surfaces caused by ngerprints, accidents, misuse, scratches, melted items or other
external sources and residues le on the plated surfaces from the use of abrasive cleaners or polishes.
• Repair or replacement of parts that are subject to normal wear and tear during the Warranty Period are not covered. These parts
include: paint, wood and pellet gaskets, rebricks, grates, ame guides, baeries and the discoloraon of glass.
• Minor expansion, contracon, or movement of certain parts causing noise. These condions are normal and complaints related to
this noise are not covered by this Warranty.
• Damages resulng from: (1) failure to install, operate, or maintain the applicable Product in accordance with the installaon
instrucons, operang instrucons, and lisng agent idencaon label furnished with the applicable Product; (2) failure to
install the applicable Product in accordance with local building codes; (3) shipping or improper handling; (4) improper operaon,
abuse, misuse, connued operaon with damaged, corroded or failed components, accident, or improperly/incorrectly performed
repairs; (5) environmental condions, inadequate venlaon, negave pressure, or draing caused by ghtly sealed construcons,
insucient make-up air supply, or handling devices such as exhaust fans or forced air furnaces or other such causes; (6) use of fuels
other than those specied in the operaon instrucons; (7) installaon or use of components not supplied with the applicable
Product or any other components not expressly authorized and approved by HHT; (8) modicaon of the appliance not expressly
authorized and approved by HHT in wring; and/or (9) interrupons or uctuaons of electrical power supply to the applicable
Product.
• Non-HHT venng components, hearth connecons or other accessories used in conjuncon with the applicable Product.
• Any part of a pre-exisng replace system in which an insert or a decorave gas applicable Product is installed.
• HHT’s obligaon under this Warranty does not extend to the Product’s capability to heat the desired space. Informaon is provided
to assist the consumer and the dealer in selecng the proper Product for the applicaon. Consideraon must be given to the
Product locaon and conguraon, environmental condions, insulaon and air ghtness of the structure.
This warranty is void if:
• The applicable Product has been over-red, operated in atmospheres contaminated by chlorine, uorine, or other damaging
chemicals. Over-ring can be idened by, but not limited to, warped plates or tubes, deformaon/warping of interior cast iron
structure or components, rust colored cast iron, bubbling, cracking and discoloraon of steel or enamel nishes.
• The applicable Product is subjected to prolonged periods of dampness or condensaon.
• There is any damage to the applicable Product due to water or weather damage which is the result of, but not limited to, improper
chimney or venng installaon.
LIMITATIONS OF REMEDIES AND LIABILITY:
• EXCEPT TO THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED
HEREIN. The owner’s exclusive remedy and HHT’s sole obligaon under this Warranty or in contract, tort or otherwise, shall be
limited to replacement of the Component Part(s), repair of the Component Part(s), or refund of the original purchase price of the
applicable Product(s), as specied above; provided, however, that (i) if HHT is unable to provide replacement of the Component
Part(s) and repair of the Component Part(s) is not commercially praccable or cannot be mely made, or (ii) the customer is
willing to accept a refund of the purchase price of the applicable Product(s), HHT may discharge all such obligaons by refunding
the purchase price of the applicable Product. In no event will HHT be liable for any incidental or consequenal damages caused
by defects in the applicable Product. Some States do not allow the exclusion or limitaon of incidental or consequenal damages,
so the above limitaon or exclusion may not apply to you. This Warranty gives you specic legal rights and you may also have
other rights which vary from State to State. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE
EXPRESSED WARRANTY SPECIFIED ABOVE FOR THE APPLICABLE PRODUCT. Some States do not allow limitaons on how long an
implied warranty lasts, so the above limitaon may not apply to you.
Page 2 of 2
4021-645L 10/20

67033-353G 08/21
C. Quick Start Guide
1 2 3
4 5
6 7
NOTE: These are generic drawings and may not represent your specifi c model.
ITEMS NEEDED FOR FIRST FIRE: 10 Pieces of Newspaper, 10-20 Pieces of Dry
Kindling and Few Pieces of Dry Split Wood.
OPEN AIR
CONTROLS
HIGH
BURN RA
TE
CONTROL
(Upper Right
Corner)
AUTOMATIC
COMBUSTION
CONTROL (ACC)
(Middle right hand side)
HIGH
LOAD WOOD ADD NEWSPAPER
ADD KINDLING
LIGHT THE PAPER
ADD MORE WOOD REDUCE AIR
CONTROLS
Set to desired heat output.
LOW
BURN RATE
CONTROL
(Upper Right
Corner)
AUTOMATIC
COMBUSTION
CONTROL (ACC)
(Middle right hand side)
LOW
The appliance is ready for
normal operation.
Warning! Risk of Fire.
Close and securely latch the door after
the fi re has started, and after refueling, to
prevent:
- Spillage of smoke, fl ame and carbon
monoxide
- Spillage of sparks, coals, and logs
- Over fi ring
DO NOT leave the appliance unattended
with the door open.
Starting a fi re may not require an open
door for draft. The air control should
supply adequate draft.

77033-353G 08/21
Model Number: DISCOVERY-II-C
Laboratory: OMNI Test Laboratories, Inc.
Report Number: 0061WS066S
Type: Listed Room Appliance, Solid Fuel
Type
Standard:
UL 1482-11 (R2015) and ULC
S627-00 and (UM) 84-HUD.
Mobile Home Approved.
Model Number: DISCOVERY-II-C
Laboratory: OMNI Test Laboratories, Inc.
Report Number: 0061WS066E
Standard: ASTM E2515, ASTM E2780
Can be found at:
www.quadrare.com/about-us/epa-certication
This wood appliance needs periodic inspection and repair
for proper operation. It is against federal regulations to
operate this wood appliance in a manner inconsistent with
operating instructions in this manual.
A. Appliance Safety Certication
B. Appliance Emissions Certication
C. BTU & Efciency Specications
NOTE: This installation must conform with local codes. In
the absence of local codes you must comply with (UM) 84-
HUD and NFPA211 in the U.S.A. and CAN/CSA-B365
Installation Codes in Canada.
1 Listing and Code Approvals
EPA Certication
Number: Number: 86-17
EPA Certied Emissions: 1.9 grams per hour
*LHV Tested Efciency: 78.3%
**HHV Tested Efciency: 72.5%
***EPA BTU Output: 13,900 to 29,100 / hr
****Peak BTU/Hour
Output: 51,000
Vent Size: 6 inches
Firebox Size: 2 cubic feet
Recommended Log
Length: 16 inches
Fuel Seasoned Cordwood
(20% moisture)
* Weighted average LHV (Low Heating Value) efciency
using Douglas Fir dimensional lumber and data collected
during EPA emission tests in accordance with the
requirements of CSA B415.1. LHV assumes the moisture
is already in a vapor state so there is no loss in energy
to vaporize.
** Weighted average HHV (High Heating Value) efciency
using Douglas Fir dimensional lumber and data collected
during EPA emission tests in accordance with the
requirements of CSA B415.1. HHV includes the energy
required to vaporize the water in the fuel.
*** A range of BTU outputs calculated using HHV
Efciency and the burn rates from the EPA tests, using
Douglas Fir dimensional lumber.
**** A peak BTU out of the appliance calculated using
the maximum rst hour burn rate from the High EPA Test
and BTU content of seasoned cordwood (8600) times
the efciency
The DISCOVERY-II-C is Certied to comply with
2020 crib wood particulate emission standards.

87033-353G 08/21
F. Sleeping Room
G. California - Prop65
WARNING
This product and the fuels used to operate this product (wood), and
the products of combustion of such fuels, can expose you to
chemicals including carbon black, which is known to the State of
California to cause cancer, and carbon monoxide, which is known to
the State of California to cause birth defects or other reproductive
harm. For more information go to: WWW.P65Warnings.ca.gov
When installed in a sleeping room it is recommended that
a smoke and/or CO alarm be installed in the bedroom. The
size of the room must be at least 50ft³ per 1,000 Btu/hr
stove input, if the stove exceeds the room size, outside air
must be installed.
NOTE: Hearth & Home Technologies, manufacturer
of this appliance, reserves the right to alter
its products, their specications and/or price
without notice.
E. Mobile Home Approved
• This appliance is approved for mobile home
installations when not installed in a sleeping room and
when an outside combustion air inlet is provided.
• The structural integrity of the mobile home oor, ceiling,
and walls must be maintained.
• The appliance must be properly grounded to the frame
of the mobile home with #8 copper ground wire, and
chimney must be listed to UL103 HT or a listed UL-
1777 full length six inch (152mm) diameter liner must
be used.
• Outside Air Kit, part OAK-ACC must be installed in a
mobile home installation.
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage.
For assistance or additional information, consult a qualied
installer, service agency or your dealer.
D. Glass Specications
This appliance is equipped with 5mm ceramic glass.
Replace glass only with 5mm ceramic glass. Please
contact your dealer for replacement glass.
WARNING
Fire Risk.
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be
voided by, the following actions:
• Installation and use of any damaged appliance.
• Modication of the appliance.
• Installation other than as instructed by Hearth &
Home Technologies.
• Installation and/or use of any component part not
approved by Hearth & Home Technologies.
• Operating appliance without fully assembling
all components.
• Operating appliance without legs attached (if
supplied with appliance).
• Do NOT Over re - If appliance or chimney
connector glows, you are over ring.
Any such action that may cause a re hazard.

97033-353G 08/21
User Guide
2 Operating Instructions
A. Over-Firing Your Appliance
B. Wood Selection & Storage
Burn only dry seasoned wood. Store wood under cover,
out of the rain and snow. Dry and well-seasoned wood will
not only minimize the chance of creosote formation, but will
give you the most efcient re. Even dry wood contains at
least 15% moisture by weight, and should be burned hot
enough to keep the chimney hot for as long as it takes to
dry the wood out - about one hour. It is a waste of energy to
burn unseasoned wood of any kind.
1. Symptoms of Over-Firing
Symptoms of over-ring may include one or more of
the following:
• Chimney connector or appliance glowing
• Roaring, rumbling noises
• Loud cracking or banging sounds
• Metal warping
• Chimney re
2. What To Do if Your Appliance is Over-Firing
• Immediately close the door and air controls to reduce
air supply to the re.
• If you suspect a chimney re, call the re department
and evacuate your house.
• Contact your local chimney professional and have
your appliance and appliance pipe inspected for
any damage.
• Do not use your appliance until the chimney
professional informs you it is safe to do so.
Dead wood lying on the forest oor should be considered
wet, and requires full seasoning time. Standing dead wood
can be considered to be about 2/3 seasoned. To tell if wood
is dry enough to burn, check the ends of the logs. If there
are cracks radiating in all directions from the center, it is
dry. If your wood sizzles in the re, even though the surface
is dry, it may not be fully cured.
Splitting wood before it is stored reduces drying time.
Wood should be stacked so that both ends of each piece
are exposed to air, since more drying occurs through the
cut ends than the sides. This is true even with wood that
has been split. Store wood under cover, such as in a shed,
or covered with a tarp, plastic, tar paper, sheets of scrap
plywood, etc., as uncovered wood can absorb water from
rain or snow, delaying the seasoning process.
C. Burning Process
In recent years there has been an increasing concern
about air quality. Much of the blame for poor air quality
has been placed on the burning of wood for home heating.
In order to improve the situation, we at Quadra-Fire
have developed cleaner-burning wood appliances that
surpass the requirements for emissions established by our
governing agencies. These wood appliances, like any other
appliances, must be properly operated in order to insure
that they perform the way they are designed to perform.
Improper operation can turn most any wood appliance into
a smoldering environmental hazard.
1. Kindling or First Stage
It helps to know a little about the actual process of
burning in order to understand what goes on inside
a appliance. The rst stage of burning is called the
kindling stage. In this stage, the wood is heated to a
temperature high enough to evaporate the moisture
which is present in all wood. The wood will reach the
boiling point of water (212°F) and will not get any hotter
until the water is evaporated. This process takes heat
from the coals and tends to cool the appliance.
Fire requires three things to burn - fuel, air and heat.
So, if heat is robbed from the appliance during the
drying stage, the new load of wood has reduced the
chances for a good clean burn. For this reason, it is
always best to burn dry, seasoned rewood. When
the wood isn’t dry, you must open the air controls and
burn at a high burn setting for a longer time to start it
burning. The heat generated from the re should be
warming your home and establishing the ue draft, not
evaporating the moisture out of wet, unseasoned wood,
resulting in wasted heat.
Fire Risk. Do not over-re.
Over-ring may ignite creosote or will damage
the appliance and chimney.
To prevent over-ring your appliance,
DO NOT:
• Use ammable liquids
• Overload with wood
• Burn trash or large amounts of
scrap lumber
• Permit too much air to the re
WARNING
Hearth & Home Technologies WILL NOT warranty
appliances that exhibit evidence of over-ring. Evidence
of over-ring includes, but is not limited to:
• Warped air tube
• Deteriorated refractory brick retainers
• Deteriorated bafe and other interior components
Visit www.quadrare.com/shopping-tools/videos to view
product and use & care videos.

10 7033-353G 08/21
2. Second Stage
The next stage of burning, the secondary stage, is the
period when the wood gives off ammable gases which
burn above the fuel with bright ames. During this
stage of burning it is very important that the ames be
maintained and not allowed to go out. This will ensure
the cleanest possible re. If the ames tend to go out,
it is set too low for your burning conditions. The air
control located at the upper right hand corner is used
to adjust for burn rates. This is called the Burn Rate Air
Control (Figure 10.1).
3. Final Stage
The nal stage of burning is the charcoal stage. This
occurs when the ammable gases have been mostly
burned and only charcoal remains. This is a naturally
clean portion of the burn. The coals burn with hot
blue ames.
It is very important to reload your appliance while
enough lively hot coals remain in order to provide the
amount of heat needed to dry and rekindle the next
load of wood. It is best to open the Burn Rate Air and
Start-Up Air Controls before reloading. This livens
up the coal bed and reduces excessive emissions
(opacity/smoke). Open door slowly so that ash or
smoke does not exit appliance through opening. You
should also break up any large chunks and distribute
the coals so that the new wood is laid on hot coals.
Air quality is important to all of us, and if we choose
to use wood to heat our homes we should do so
responsibly. To do this we need to learn to burn our
appliances in the cleanest way possible. Doing this
will allow us to continue using our wood appliances for
many years to come.
D. Air Controls
Users will need to nd their preferred setting between
high and low based on desired heat output, installation
conguration, and fuel type.
1. Burn Rate Air Control
This air supply enters at the upper front of the rebox,
near the top of the glass door. This preheated air
supplies the necessary fresh oxygen to mix with the
unburned gases, helping to create second, third and
fourth combustions. This air is regulated by the Burn
Rate Air Control. When the control is moved all the way
up it is on the High setting and when moved all the way
down it is on the Low setting (Figure 10.1).
2. Automatic Combustion Control System (ACC)
To engage the Automatic Combustion Control (ACC)
timer system push the lever towards the back of the
appliance to the “HI” position, then pull forwards
towards the front of the appliance until the knob stops.
The timer will slowly close in about 25 minutes. Use
this feature when reloading fuel or if you want more air
supplied to the re (Figure 10.2).
Figure 10.1
HIGH
MED
LOW
Burn Rate
Air Control
Start-Up
Air Control
Figure 10.2
Over rides timer & opens
rear air to open locked
position
Open rear air medium air
flow
Engages timer push knob
towards HI then back to
any point within dotted line
Open rear air medium-low
air flow
Closes front and rear air

11 7033-353G 08/21
Figure 11.1
Figure 11.2
HIGH
MED
LOW
Burn Rate
Air Control
Start-Up
Air Control
Manual
Timer (ACC)
Shut Down
PullForward
to Shut Down
E. Using Burn Rate Air Control & ACC System
Injury Risk.
• Gloves recommended
CAUTION
1. Start up and Reloading Fuel
Open both Burn Rate Air Control and ACC systems fully. To
do this with the Burn Rate Air Controls push spring handle
up to high. For the ACC timer system push knob towards
back of appliance until the knob is located under the high
position (Figure 11.1).
2. Maximize Heat with The ACC System
To maximize heat output with the ACC timer System or also
known as high burn push the ACC Air Control lever towards
the back of the appliance and leave. This combined with
having the main burn rate control lever pushed up will
deliver the most amount of air needed to achieve the
highest amount of heat output (Figure 11.1).
3. Manual Timer Over-Ride
If you need to shut the ACC system off before it goes
through the cycle of shutting itself off; 25 minutes, reach
towards the back of the appliance on the right side and pull
the lever towards the front of the appliance (Figure 11.2).

12 7033-353G 08/21
Figure 12.1
F. Burn Rates and Operating Efciency
For maximum operating efciency
This wood appliance has a manufacturer-set minimum
low burn rate that must not be altered. It is against federal
regulations to alter this setting or otherwise operate this
wood appliance in a manner inconsistent with operating
instructions in this manual.
• Burn dry, well-seasoned wood.
Burn Rates
1. Low burn setting:
• Burn Rate Air Control spring handle up to high
position for 5 minutes.
• Then activate the ACC timer system by pushing
the knob all the way back toward the appliance
to “HI” then pull forwards towards the front of the
appliance until the knob stops (Figure 10.1 on
page 10).
• At that point close the Burn Rate Air Control by
moving the spring handle to the low setting.
2. Medium low burn setting:
• Burn Rate Air Control spring handle up to high
position for 5 minutes.
• Then activate the ACC timer system by pushing
the knob all the way back toward the appliance
to “HI” then pull forwards towards the front of the
appliance until the knob stops.
• At that point move the Burn Rate Air Control spring
handle to 1/8”-1/2” from the low setting.
3. Medium high burn setting:
• Burn Rate Air Control spring handle up to
high position.
• Then activate the ACC timer system by pushing
the knob all the way back toward the appliance
to “HI” then pull forwards towards the front of the
appliance until the knob stops.
• At that point move the Burn Rate Air Control spring
handle to 1/2” – high.
4. High burn setting:
• Burn Rate Air Control spring handle up to
high position
• Also activate ACC timer system knob pushed back
to the “HI” position.
NOTE: The above information is provided as a guideline
only. Altitude and other circumstances may
require control adjustments to achieve the
desired burn rates.
NOTE: Operate appliance on High Burn 45 minutes a
day to help keep ue/chimney clean.
NOTE: If using the optional blower, for burn rate
settings 1-3, the blower shall be off for the rst
30 minutes and then be operated in the high
position at 30 minutes. For high burn setting,
blower may continue to be on full after the
loading of the fuel.
After activating the timer (ACC), if the control is placed
within the rear air section on the label it will allow rear air
to enter the rebox. This will not interfere with the timer
gradually closing the front air channel in 25 minutes. If
control is set on “HI” it over-rides the timer (ACC).
HIGH
LOW
Shown with Side
Shield Removed
Timer
Burn Rate
Air Control
Low (Closed)
High (Open)
Timer Manual
Shut-off
RearAir Channel
Operates independently
from Timer
Front Air Channel
Operated by Timer
Start-Up Air
Control
WARNING
Risk of Fire.
When set on High Burn Rate and over-riding
the Automatic Combustion Control system an
over re situation can occur and may result in
a chimney re.
Over ring will void the appliance warranty.

13 7033-353G 08/21
Figure 13.1
G. Building A Fire
Before lighting your rst re in the appliance:
NOTE: The special high temperature paint that your
appliance is nished with will cure as your
appliance heats. You will notice an odor and
perhaps see some vapor rise from the appliance
surface; this is normal. We recommend that you
open a window until the odor dissipates and
paint is cured.
Figure 13.2
1. Conrm the bafe is correctly positioned. It should
be even with the front tube and resting on all tubes
(Figure 13.1 and Figure 13.2).
2. Remove all labels from glass and inside of appliance.
There are many ways to build a re. The basic principle is
to light easily-ignitable tinder or paper, which ignites the
fast burning kindling, which in turn ignites the slow-burning
rewood. Here is one method that works well:
1. Open the Burn Rate Air and ACC Controls fully (Refer to
Start-Up Guide on page 6).
2. Place several wads of crushed paper on the rebox
oor. Heating the ue with slightly crumpled newspaper
before adding kindling keeps smoke to a minimum.
3. Lay small dry sticks of kindling on top of the paper.
4. Make sure that no matches or other combustibles
are in the immediate area of the appliance. Be
sure the room is adequately ventilated and the
ue unobstructed.
5. Light the paper in the appliance. NEVER light or
rekindle re with kerosene, gasoline, or charcoal lighter
uid; the results can be fatal.
6. Once the kindling is burning quickly, add several full-
length logs 3 inches (76mm) or 4 inches (102mm) in
diameter. Be careful not to smother the re. Stack the
pieces of wood carefully; near enough to keep each
other hot, but far enough away from each other to allow
adequate air ow between them.
7. Set the Burn Rate Air Control and activate the ACC
timer system.
8. When ready to reload, It is best to fully open both
the Burn Rate Air and Start-up Air Controls before
reloading. This livens up the coal bed and reduces
excessive emissions (opacity/smoke). Open door
slowly so that ash or smoke does not exit appliance
through opening. Large logs burn slowly, holding a re
longer. Small logs burn fast and hot, giving quick heat.
9. As long as there are hot coals, repeating steps 6
through 8 will maintain a continuous re.
NOTE:
• Build re on brick rebox oor.
• Do NOT use grates, andirons or other methods to
support fuel. It will adversely affect emissions.
Baffle Board even with front tube & resting
on all tubes
Burn Rate
Air Control
Start-Up Air
Control
Tube Channels
Ceramic Blanket on Top
2 pc Baffle Board
WARNING
Fire Risk.
Do NOT store wood:
• Closer than required clearances to
combustibles to appliance
• Within space required for loading or
ash removal.
Do NOT operate appliance:
• With appliance door open.
• With ash removal system door open.
Fire Risk.
• Do NOT burn wet or green wood.
• Store wood in dry location.
• Stack wood so both ends are exposed
to air.
Wet, unseasoned wood can cause
accumulation of creosote.
WARNING
Fire Risk.
• Do not leave the re unattended when
the door is unlatched or when using the
re screen.
• Unstable rewood could fall out of the
rebox creating a re hazard to your home.
WARNING

14 7033-353G 08/21
H. Blower Operating Instructions
Fire Risk.
Keep combustible materials, gasoline and
other ammable vapors and liquids clear
of appliance.
• Do NOT store ammable materials in the
appliance’s vicinity.
• DO NOT USE GASOLINE, LANTERN
FUEL, KEROSENE, CHARCOAL
LIGHTER FLUID OR SIMILAR LIQUIDS
TO START OR “FRESHEN UP” A FIRE IN
THIS APPLIANCE.
• Keep all such liquids well away from the
appliance while it is in use.
• Combustible materials may ignite.
WARNING
I. Opacity (Smoke)
This is the measure of how cleanly your appliance is
burning. Opacity is measured in percent; 100% opacity is
when an object is totally obscured by the smoke column
from a chimney, and 0% opacity means that no smoke
column can be seen. As you become familiar with your
appliance, you should periodically check the opacity. This
will allow you to know how to burn as nearly smoke-free as
possible (goal of 0% opacity).
Figure 14.1 Snap Disc Location
Figure 14.2
MANUAL
FAN
AUTO
LOW
HIGH OFF
MANUAL:
Over-rides
the Snap
Disc
AUTO: Fan
will turn
ON/OFF
Automatically
by the Snap
Disc
Controls
the Fan
Speed
NOTE: If your Quadra-Fire wood appliance is equipped
with an optional blower, you should follow
these guidelines:
1. Initial (cold) start-up and all Burn Settings
The blower can be plugged in and turned on right
away. The blower fan is turned on and off by a snap
disc. When your appliance has reached a certain
temperature the blower will turn on and when your
appliance has cooled down to a certain temperature
it will turn off. Switch on blower control must be set to
auto for this feature to work.
2. The blower is equipped with a speed control. Adjust
the fan speed by turning the speed control clockwise to
“Low” or counterclockwise to “High”.
3. Snap Disc Location
If you nd the blower coming on and off at undesirable
temperatures, relocate the snap disc to another
location in the designated zone on the back of the
appliance (Figure 14.1). There is a manual over-
ride switch to deactivate the snap disc, if necessary
(Figure 14.2).
When burning your rst re, you will experience
smoke and odor from the appliance resulting from the
curing of paint and burning off of any oils remaining
from manufacturing.
OPEN WINDOWS DURING INITIAL BURN TO
DISSIPATE SMOKE AND ODORS!
• Odors may be irritating to sensitive individuals.
• Smoke detectors may activate.
CAUTION
WARNING
Fire Risk.
• DO NOT BURN GARBAGE OR
FLAMMABLE FLUIDS SUCH AS
GASOLINE, NAPHTHA OR ENGINE OIL.
• Do NOT burn treated wood or wood with
salt (driftwood).
• May generate carbon monoxide if burn
material other than wood.
May result in illness or possible death.

15 7033-353G 08/21
Negative pressure results from the imbalance of air available
for the appliance to operate properly. It can be strongest in
lower levels of the house.
Causes include:
• Exhaust fans (kitchen, bath, etc.)
• Range hoods
• Combustion air requirements for furnaces, water
appliances and other combustion appliances
• Clothes dryers
• Location of return-air vents to furnace or air
conditioning
• Imbalances of the HVAC air handling system
• Upper level air leaks such as:
- Recessed lighting
- Attic hatch
- Duct leaks
To minimize the effects of negative air pressure:
• Install the outside air kit with the intake facing prevailing
winds during the heating season
• Ensure adequate outdoor air for all combustion
appliances and exhaust equipment
• Ensure furnace and air conditioning return vents are
not located in the immediate vicinity of the appliance
• Avoid installing the appliance near doors, walkways or
small isolated spaces
• Recessed lighting should be a “sealed can” design
• Attic hatches weather stripped or sealed
• Attic mounted duct work and air handler joints and
seams taped or sealed
K. Negative Pressure
J. Clear Space
Figure 15.1
Maintain 4 ft (1.22m) clearance to
combustible in front of appliance
WARNING
Asphyxiation Risk.
• Negative pressure can cause spillage
of combustion fumes, soot and
carbon monoxide.
• Appliance needs to draft properly
for safety.
WARNING
Do NOT place combustible objects in front of the
appliance. High temperatures may ignite clothing,
furniture or draperies.
NOTE: Do NOT place combustible objects within 4 ft
(1.2 m) of the front of appliance (Figure 15.1).
• Mantel:
Avoid placing candles and other heat-sensitive objects
on mantel or hearth. Heat may damage these objects.

16 7033-353G 08/21
L. Frequently Asked Questions
ISSUES SOLUTIONS
Odor from appliance When rst operated, this appliance may release an odor for the rst several hours. This is
caused by the curing of the paint and the burning off of any oils remaining from manufacturing.
Metallic noise
Noise is caused by metal expanding and contracting as it heats up and cools down, similar to
the sound produced by a furnace or heating duct. This noise does not affect the operation or
longevity of the appliance.
Whirring sound If the optional blower has been installed, the blower produces a whirring sound which
increases in volume as the speed is increased.
CONTACT YOUR DEALER for additional information regarding operation and troubleshooting.
Visit www.quadrare.com to nd a dealer.
WARNING
Fire Risk.
• DO NOT BURN GARBAGE OR
FLAMMABLE FLUIDS SUCH AS
GASOLINE, NAPHTHA OR ENGINE OIL.
• Do NOT burn treated wood or wood with
salt (driftwood).
• May generate carbon monoxide if burn
material other than wood.
May result in illness or possible death.
Fire Risk.
Keep combustible materials, gasoline and
other ammable vapors and liquids clear
of appliance.
• Do NOT store ammable materials in the
appliance’s vicinity.
• DO NOT USE GASOLINE, LANTERN
FUEL, KEROSENE, CHARCOAL
LIGHTER FLUID OR SIMILAR LIQUIDS
TO START OR “FRESHEN UP” A FIRE IN
THIS APPLIANCE.
• Keep all such liquids well away from the
appliance while it is in use.
• Combustible materials may ignite.
WARNING
Table 16.1

17 7033-353G 08/21
3 Maintenance and Service
A. Quick Reference Maintenance Guide
When properly maintained, your replace will give
you many years of trouble-free service. Contact your
dealer to answer questions regarding proper operation,
troubleshooting and service for your appliance. Visit
www.quadrare.com/owner-resources to view basic
troubleshooting, FAQs, use & care videos.
CAUTION
Allow the appliance to completely cool down before
performing any cleaning or maintenance. Start the
rst inspection after the rst 2 months of use, or if
performance changes, and adjust your schedule
accordingly. Maintenance is required for safe operation
and must be performed to maintain your warranty.
Table 17.1
FREQUENCY TASK
Baffl e & Blanket
MONTHLY
or after every
one (1) cord of
wood
Baffl e and blanket placement is critical to heat output, effi ciency and
overall life of the appliance. Make sure the baffl e is pushed all of the
way to the back of the fi rebox and the blanket is laying fl at. Inspect
baffl e for cracks.
Ceramic Blanket Back of Firebox
Baffle Board
Baffle Retainer
Bracket
Optional Blower
YEARLY or after
every four (4)
cords of wood Vacuum the blower impellers.
Chimney System
EVERY TWO
MONTHS
or after every
four (4) cords of
wood
The chimney and chimney cap must be inspected for soot and
creosote every two months during the burn season or more frequency
if chimney exceeds or is under 14-16 ft (4.3m-4.8m) measured from
bottom of appliance.
This will prevent pipe blockage, poor draft, and chimney fi res.
Always burn dry wood to help prevent cap blockage and creosote
build-up.
Firebrick & Ash Removal
WEEKLY
or after every 25
loads of wood
Ashes must be cool before you can dispose of the ashes in a non-
combustible container.
Firebrick is designed to protect your fi rebox. After ashes are removed,
inspect the fi rebrick and replace fi rebricks that are crumbling, cracked
or broken.
Door & Glass Assemblies
WEEKLY
or after every 25
loads of wood
Keep door and glass gasket in good shape to maintain good burn.
To test: place a dollar bill between the appliance and door and then
shut the door. If you can pull the dollar out, remove one washer from
door handle behind latch cam and try again. If you can still pull it out,
replace the door gasket.
Check the glass frame for loose screws to prevent air leakage.
Check glass for cracks.
Door Handles
WEEKLY
or after every 25
loads of wood
Check the door latch for proper adjustment. This is very important
especially after the door rope has formed to the appliance face.
Check door handle for smooth cam operation.
These are generic drawings and may not represent your model.

18 7033-353G 08/21
B. General Maintenance
1. Creosote (Chimney) Cleaning
• Frequency: Every 2 months during heating season or
as recommended by a certied chimney sweep; more
frequently if chimney exceeds or is under 14-16 ft.
(measured from bottom of appliance)
• By: Certied Chimney Sweep
Remove all ash from the rebox and extinguish all hot
embers before disposal. Allow the appliance to cool
completely. Disconnect ue pipe or remove bafe and
ceramic blanket from appliance before cleaning chimney.
Otherwise residue can pile up on top of the bafe and
ceramic blanket and the appliance will not work properly.
(See Bafe Removal on page 24). Close the door tightly.
The creosote or soot should be removed with a brush
specically designed for the type of chimney in use. Clean
out fallen ashes from the rebox.
It is also recommended that before each heating season
the entire system be professionally inspected, cleaned and
repaired if necessary.
Inspection:
Inspect the system at the appliance connection and at
the chimney top. Cooler surfaces tend to build creosote
deposits quicker, so it is important to check the
chimney from the top as well as from the bottom.
Formation and Need For Removal:
When wood is burned slowly, it produces tar and other
organic vapors which combine with expelled moisture
to form creosote.
The creosote vapors condense in the relatively cool
chimney ue of a newly-started or a slow-burning re. As
a result, creosote residue accumulates on the ue lining.
When ignited, this creosote creates an extremely hot re
which may damage the chimney or even destroy the house.
The chimney connector and chimney should be inspected
once every 2 months during the heating season to
determine if a creosote or soot buildup has occurred. If
creosote or soot has accumulated, it should be removed to
reduce the risk of a chimney re.
2. Disposal of Ashes
• Frequency:
When ash is within 1-3/4 in. (44mm) of
rebox lip
• By: Homeowner
WARNING
Fire Risk.
Prevent creosote buildup.
• Inspect chimney connector and
chimney once every two months during
heating season.
• Remove creosote to reduce risk of
chimney re.
• Ignited creosote is extremely HOT.
Fire Risk.
• Do not use chimney cleaners or ame
colorants in your appliance. Will corrode
chimney pipe.
WARNING
Fire Risk. Disposal of Ashes
• Ashes should be placed in metal container
with tight tting lid.
• Do not place metal container on
combustible surface.
• Ashes should be retained in closed
container until all cinders have
thoroughly cooled.
WARNING
Ashes should be placed in a metal container with a tight
tting lid. The closed container of ashes should be placed
on a non-combustible oor or on the ground, well away
from all combustible materials, pending nal disposal. If the
ashes are disposed of by burial in soil or otherwise locally
dispersed, they should be retained in the closed container
until all cinders have thoroughly cooled.
Fire Risk.
Ashes could contain hot embers.
WARNING
3. Appliance Inspection
• Frequency: Every 2 months at the same time the
chimney and chimney connector are inspected.
• By: Homeowner
Check for:
• Cracks in glass
• Door handle - smooth cam operation
• Bafe and ceramic blanket correct placement
• Bafe for warp-age
• Firebrick for cracks, broken or crumbly
• Door gasket (Dollar bill test): Place a dollar bill between
the stove and the door and then shut the door. If you
can pull the dollar bill out, replace the door gasket.
• Glass frame for loose screws

19 7033-353G 08/21
4. Glass Cleaning
• Frequency: As desired
• By: Homeowner
CAUTION
• Do not use polishes with abrasives. It will scratch
plated surfaces.
CAUTION
• Do not use polishes with abrasives. It will
scratch surfaces.
5. Cleaning Plated Surfaces
• Frequency: Prior to first burn and then as desired
• By: Homeowner
Clean all the ngerprints and oils from plated surfaces
BEFORE ring the appliance for the rst time. If not
cleaned properly before lighting your rst re, the oils can
cause permanent markings on the plating.
After the plating is cured, the oils will not affect the nish
and little maintenance is required. Wipe clean as needed.
Clean glass with a non-abrasive glass cleaner. Abrasive
cleaners may scratch and cause glass to crack. If the
deposits on the glass are not very heavy, normal glass
cleaners work well. Heavier deposits may be removed by
using a damp cloth dipped in wood ashes or by using a
commercially available oven cleaner.
After using an oven cleaner, it is advisable to remove any
residue with a glass cleaner or soap and water. Oven
cleaner left on during the next ring can permanently stain
the glass and damage the nish on metal surfaces.
A portion of the combustion air entering the rebox is
deected down over the inside of the door glass. This
air ow “washes” the glass, helping to keep smoke from
adhering to its surface.
When operated at a low burn rate, less air will be owing
over the glass and the smokey, relatively cool condition of a
low re will cause the glass to become coated.
Operating the appliance with the Burn Rate Air Control and
Start-Up Air Control all the way open for 30-45 minutes
should remove the built up coating.
CAUTION
Handle glass assembly with care. Glass is breakable.
• Avoid striking, scratching or slamming glass
• Avoid abrasive cleaners
• Do not clean glass while it is hot
6. Inspect Firebrick
• Frequency: After each ash removal
• By: Homeowner
Replace the rebrick if they become crumbly and/or if there
is a 1/4 inch (6.35mm) gap between the bricks.
The rebox is lined with rebrick, which has exceptional
insulating properties. Do not use a grate; simply build
a re on the rebox oor. Do not operate appliance
without rebrick.
1. After the coals have completely cooled, remove all old
brick and ash from unit and vacuum rebox.
2. Remove new brick set from box and lay out to the
diagram shown in the instructions that come with the
brick set or refer to the diagram on the service parts list
at the end of this manual.
3. Lay bottom bricks in unit.
4. Install rear bricks on the top of the bottom bricks. Slide
top of bricks under clip on back of rebox wall and push
bottom of bricks back.
5. Install side bricks. Slide top of brick under clips on side
of rebox and push the bottom of the brick until it is
ush with the side of the unit.

20 7033-353G 08/21
INCORRECT POSITIONS
C. Correct Bafe & Blanket Placement
Ceramic Blanket and Bafe Board are NOT in contact
with the back of the rebox.
Ceramic Blanket is NOT in contact with the back of the
rebox and NOT even with the Bafe Board in the front.
Ceramic Blanket is bunched up at the back of the rebox
and NOT even with the Bafe Board in the front.
Figure 20.2
Figure 20.1
CORRECT POSITION
Ceramic Blanket and Bafe Board MUST be in contact
with the back of the rebox and even with each other in
the front.
WARNING
Fire Risk.
Firebox damage due to improper bafe
placement is not covered by warranty.
Operate the wood burning appliance with the
bafe in the correct position only.
Not doing so could result in:
• Reduced efciency
• Overheating the chimney
• Overheating the rear of the rebox
• Poor performance
Ensure correct bafe placement and replace
bafe components if damaged or missing.
Ceramic Blanket
Back of
Firebox
Baffle Board
Ceramic Blanket Back of Firebox
Baffle Board
Baffle Retainer
Bracket
The bafe boards are FRAGILE. Use extreme caution
when loading rewood to prevent:
• Cracking, breaking or damaging the bafe boards
DO NOT operate the appliance without bafe boards
CAUTION
Table of contents
Popular Controllers manuals by other brands

Adaptec
Adaptec ASR-3085 Important information about issues and errata

Vega
Vega VEGATOR 141 operating instructions

RealSimulator
RealSimulator F16SGRH user guide

IR Robot
IR Robot mightyZAP user manual

GESTRA
GESTRA NRR 2-50 Original Installation & Operating Manual

RYTEC
RYTEC System 3 Installation & owner's manual

EUCHNER
EUCHNER CEM-A Series operating instructions

ZIEHL-ABEGG
ZIEHL-ABEGG Acontrol PKE-6 operating instructions

Sumpo Electric Co., Ltd.
Sumpo Electric Co., Ltd. P9000 instruction manual

Hunter
Hunter Hydrawise HC-1200M owner's manual

Danfoss
Danfoss vlt soft starter mcd 500 Pocket guide

ICP DAS USA
ICP DAS USA SMS-531 user manual