Quantum BARRACUDA BAR811 User manual

OPERATING INSTRUCTIONS

BAR811/ BAR844
1000 meter Automatic
Helium Escape Valve
BAR822/ BAR833
1000 meter Manual
Helium Escape Valve
BAR81/Automatic Helium Escape Valve
SCREW CHRONO BUTTON
CHRONOGRAPH/START and STOP
SCREW CROWN/CLOSE
CALENDAR ADJUSTMENT
HELIUM ESCAPE VALVE
HOUR ADJUSTMENT
SCREW CROWN/OPEN
CHRONOGRAPH/START POINT
SCREW CHRONO BUTTON
BARRACUDA
Your Barracuda Diver is the watch for
professional and amateur divers, as
well as demanding sportsmen. The new
helium escape valve together with all the
protection systems, offer optimal security
and reliability. In order to ensure that your
watch remains watertight, we recommend
that you have it checked by an authorised
service center.
ALWAYS MUST BE CLOSED POSITION
Helium escape valve
When carrying out work at great depths, professional divers stay in a diving bell for several days, breathing a mixture of
gases containing a high proportion of helium. The pressure is gradually increased to reach the pressure at the working
depth. The divers, still inside the bell, are then lowered to the working site. They leave the bell to carry out their work.
Once their work is complete, they re-enter the bell, which is then raised to the surface. Pressure is then returned to
atmospheric levels and this is when the valve must be opened (only for deep-sea dives lasting several days) The helium
molecules diffuse and penetrate the material of the gas kets. The quantity is sufficient to push out the crystal during the
return to atmospheric pressure. To avoid this, the Barracuda Diving watch is equipped with a valve specially produced
by Quantum Watches.
CAUTION:
PLEASE PAY MORE ATTENTION TO KEEP CLOSED HELIUM ESCAPE VALVE, CHRONO BUTTONS AND SCREW
CROWN. OTHERWISE YOURWATCHWILL LOSE IT’SWATERPROOF SPESIFICATION.

BAR822/Manual Helium Escape Valve BAR833/Manual Helium Escape Valve
SCREW CHRONO BUTTON
CHRONOGRAPH/START and ST OP
SCREW CHRONO BUTTON
CALENDAR ADJUSTMENT
SCREW CHRONO BUTTON
CHRONOGRAPH/START and STOP
SCREW CHRONO BUTTON
CALENDAR ADJUSTMENT
SCREW CROWN/OPEN
HOUR ADJUST MENT
HOUR ADJUSTMENT
SCREW CROWN/OPEN
CHRONOGRAPH/START POINT
CHRONOGRAPH/START POINT
HELIUM ESCAPE VALVE
SCREW CHRON O BUTTON
HELIUM ESCAPE VALVE
ALWAYS MUST BE CLOSED POSITION
SCREW CHRONO BUTTON
ALWAY S MUST BE CLOSED POSITION
How to use the helium escape valve? (fig.2)
In its normal position (fig.2.1), the helium escape
valve is perfectly watertight thanks to the gaskets
During the decompression phase, unscrew the crown of the
valve in order to release the mechanism (fig.2.2). The valve is now
watertight from the outside. As the interior pressure becomes
greater than the exterior pressure, it pushes the gasket (A) out of
its seating, thus releasing the gas (fig.2.3). Once the pressure is
equalised, gasket (A) returns to its original position, pushed by the
SCREW CHRONO BUTTON
SCREW CROWN/CLOSE
HELIUM ESCAPE VALVE
(B), but it is not functional, since it is screwed down. spring (C) (fig.2.2).This operation is automatically repeated several
times during the decompression phase. Once atmospheric
pressure is reached, screw down the crown of the valve (fig. 2.1).
Note: Even if the valve is unscrewed, we strongly recommend that
the valve remains screwed down whenever the watch is immersed
in water, the watch is still water-resistant to a relative pressure of
in water, the watch is still water-resistant to a relative pressure of
5 Bar (50 metres). However, complete water-resistance tothe dial
depth can only be achieved with gasket (B) andthe valve in the
screwed down position.
Automatic helium escape valve: if your watch is equipped with an
automatic helium escape valve, no manipulation is required.
NOTE: Automatic helium escape
valve: if your watch is equipped
with an automatic helium escape
valve, no manipulation is required.
CALENDAR ADJUSTMENT
HOUR ADJUSTMENT
SCREW CROWN/OPEN
SCREW CHRONO BUTTON
BAR844/Automatic
Helium Escape Valve

NSOR
ONO
BAR855/ BAR866200 meter Ana-
DigiCitizen CS00 Diving Movement
SCREW CHRONO BUTTON
SCREW CHRONO
BUTTON
PRESSURE SENSOR
SCREW CHRONO
BUTTON
SCREW CROW N/
CLOSE
SCREW CROW N/
OPEN
SCREW CHRONO BUTTON
SCREW CHRONO
BUTTON
PRESSURE SE
SCREW CHR
BUTTON
SCREW CROWN/
CLOSE
SCREW CROWN/
OPEN
BAR866/Citizen CS00 Diving Movement
BAR855/Citizen CS00 Diving Movement

Cal. No CS00
INSTRUCTION MANUAL
Highly reliable water resistance for use at depths of up to 200 meters
A. Diving with this Watch
WARNING:
Safe diving
Do not use the depth meter when...

CAUTION:
Stop using this product while diving when...
B. Name of Parts
D. Time/Calendar Mode
Switching in the digital display (II)
When manipulating the crown...About the screw lock
Screw locked position Freed from the screw lockedposition
C.Switching Modes
From any mode shown in
the boxbelow:
Setting the Time and Calendar
a. AlwaysperformtheDigitalsetting�irst, then the
Analogsetting.
a. Digitalsetting
Setting theTime
A
SEL
SET
CA
SEL

b. Analog setting Setting
the Analog Time
E. Alarm Mode
F. Chronograph Mode
Using the chronograph
<Standard measurement>
Setting the alarm
<Split time measurement>
<Note>
Alarm ON/OFF
Alarm monitoring
<Auto-return system>
Additional feature
<Auto-return system>
Split time:

G. Log Mode
The dive log data can be retained in the watch, counting the last 4 dives.
1. Number ofdives:
2. Dive month and date:
3. Maximum depth:
4. Dive time:
5. Dive start time:
6. Dive end time:
7. Averagedepth:
8. Minimumtemperature:
Changing the Log Display
Todelete all logdata;
In case the depth indication �lashes:
In case ER(error) is shown:
H. Dive AlarmModes

The following two alarm functions are provided as divealarms used in this watch.
1. Depth alarm function:
2. Dive time alarm function:
Setting the depth alarm/ dive time alarm
İ.Diving Mode
Dive Alarm Monitor
Additional feature
<Water Sensing Function>

Depth Measurement Readings
Depth Measurement
1. Depth Measurement
3. Water Temperature Measurement
Dive the measurement
2. Dive Time Measurement
High altitude & Freshwater diving
However,an accurate measurement is
notpossible at altitudesover4,000 meters (13,124 ft).
Before diving
During diving
After diving
J. Precautions for Diving Mode Use
Making accurate depth readings
K. Various Alert Functions
1. AscendingSpeedWarning

2. Abnormal DepthAlert
M. All Reset
3. Water Sensor Check Alert
L. In Case of the Following:
The second hand goes at 2-second intervals.
Changeover cannot be performed from thediving mode [Ready display] or [0m Reading after Depth
Measurement]tothetime/calendarmode.
•In case the depth reading is one meter or more, though the watch is used on land
•Digitaldisplaymalfunction
•Afterbatteryreplacement
* Note 1
N. The Battery
a. Batterylife
Number of dives:
Duration of dives:
b. Theoriginalbattery
c. Batteryreplacement
O. Other Functions
Register ring
Example:
DIV
CA
P
SEL
CA
DIV
CA
40

No decompression limits
The range of time when it is unnecessary to stop to decompress while surfacing from a dive is determined by the depth
and time ofthe dive.Thesevaluesarereferred to as “No Decompression Limits.” Use these as estimateswhendiving.
<Reading the chart>
DEPTH. m....N.D. Time12
m. ..............................200
Min.15 m. ................100
Min.18 m. ................ 60
Min.21 m. ................ 50
Min.24 m. ................ 40
Min.27 m. ................ 30
Min.30 m. .................25
Min.33 m. ................ 20
Min.36 m. ................ 15
Min.39 m. ................ 10
Min.42 m. ................ 10
Min.45 m............5 Min.
P.
Speci�ication
1. Calibernumber
2. Accuracy oftime
measurement
3. Accuracyofdepth
reading
4. Accuracy of
temperaturereading
5. Watchoperational
temperaturerange
6. Displayfunction
Caution:
Example:
Dive alarm mode:
Dive:

Cal. No CS00
GEBRAUCHSANWEISUNG
7. Alarmfunctions
8.Additional features
9.Battery to be used
10.Batterylifetime

VORSICHT:
Wasserdicht bis zu einer Tiefe von 200 Metern
1. Einsatz der Uhr beim Tauchen
BESONDERE VORSICHT:
Sicheres Tauchen
Keine Benutzung des Tiefenmessers unter den folgenden Umständen...
Notwendigkeit zum Beenden des Betriebs dieses Produkts unter den folgenden Umständen
B.Bezeichnung derTeile
C.Umschalten-Zwischen den
Betriebsarten
A
SE L
SET
CA
SEL

D. Uhrzeit/Kalender-Modus
UmschaltenzurDigitalanzeige(II)
Handhabung der Krone Über die Schraubarretierung
To remove th
i
s not
i
ce
,
v
i
si
b. Analog-Einstellung
EinstellenderAnalogzeit
E. Alarm-Modus
Einstellen der Alarmzeit
Einstellen der Uhrzeit und des Kalenders
a.Immer zuerst die Digital-Einstellung und
dann die Analog-Einstellungdurchführen.
a. Digital-Einstellung
EinstellenderUhrzeitunddesKalenders
Ein-undAusschaltendesAlarms
Überprüfen des Alarms
<Rückschaltautomatik>

F. Stoppuh-Modus
G. Protokoll-Modus
Verwendung der Stoppuhr
<Normale Zeitmessung>
Die Tauch-Protokolldaten für die letzten 4 Tauchgänge können in der Uhrgespeichert werden.
<Aufeinanderfolgende Zeitmessungen mit Summierung>
<Messung von Zwischenzeiten>
Wechseln derProtokoll-Anzeige
<Hinweis>
Zusätzliche Funktion
<Rückschaltautomatik>
Zwischenzeit:

1.Anzahl Tauchgänge:
2. Monat und Datum:
3. Größte Tiefe:
4. Tauchzeit:
5. Tauch-Anfangszeit:
6. Tauch-Endezeit:
7. DurchschnittlicheTiefe:
8. Niedrigste Temperatur:
Bei dieser Uhr stehen die folgenden beiden Tauchalarm-Funktionen zuVerfüg
r
1.Tiefenalarm: To remove this
www
.
fox
i
tsoftware
.
c
2. Tauchzeit-Alarm:
LöschenallerProtokolldaten;
WenndieTiefenanzeigeblinkt;
Einstellen des Tiefenalarms/Tauchalarms
Wenn ER (Fehler) angezeigt wird;
H. Tauchalarm-Modus
(Hinweis)
Überprüfen des Tauchalarms

İ.Tauch-Modus
Tiefenmessung-Anzeigen
Tiefenmessung
1. Tiefenmessung
Wenn ER (Fehler) angezeigt wird und
dieTiefenanzeige blink
3. Wassertemperatur-Messung
2. Tauchzeit-Messung
J. Vorsichtsmaßnahmen bei Versendung desTauch-Modus
Maßnahmen für präzise Tiefenmessungen
Maßnahmen für präzise Tiefenmessungen
Tiefe
Zusätzliche Funktion
<Wassersensor-Funktion>

Tauchen in Gewässern in großer Höhe und in Binnengewässern 2.WarnungvoranomalerTiefe
Vor dem Tauchen
Während des Tauchens
Nach dem Tauchen
K. VerschiedeneWarnfunktionen
1. Aufstiegsgeschwindigkeit-Warnung
3. Wassersensor-Prüfwarnung
L. IAbhilfemaßnahmen in der Folgenden Fällen:
Der Sekundenzeiger bewegt sich in 2-Sekunden-Schritten.
•Es kann nicht vom Tauch-Modus [Bereitschaft-Anzeige] oder [0 m-Anzeigenach Tiefenmessung] in den
Uhrzeit/Kalender-Modus umgeschaltet werden.•Die Tiefenanzeige beträgt ein Meter oder mehr, obgleich die
Uhr an Land benutztwird.
•Fehlfunktion der Digitalanzeige
•Nach Batteriewechsel
)
*Hinweis 1
DIV
CA
DIV
CA

M. Gesamtrückstellung
DekompressionsfreieBereiche
Der Zeitbereich, in dem ein Aufstieg an die Ober�läche ohne Dekompression spausen möglich ist, richtet sich nach der
Tauchtiefe und der Tauchzeit. DiesWertpaare de�inieren jeweils e
Tionernem“Doevkeomthp
i
srenssoito
i
cnsef
,
revi
i
esnit:
Bereich”. VerwendeSie diese Werte als Richtlinien beim Tauchen.
N. Die Batterie
a. Lebensdauer
<Ablesen der Tabelle>
Tiefe-in KeineDekom-Meternpressionnach
Time12 m. ............ 200
Anzahl der Tauchgänge:
Dauer eines Tauchgangs:
b. Mitgelieferte Batterie
C. Batteriewechsel
O. Sonstige Funktionen
Registrierring
Min.15 m.............. 100
Min.18 m.............. 60
Min.21 m.............. 50
Min.24 m.............. 40
Min.27 m.............. 30
Min.30 m.............. 25
Min.33 m.............. 20
Min.36 m.............. 15
Min.39 m.............. 10
Min.42 m.............. 10
Min.45 m...........5 Min.
P. TechnischeDaten
1. Kaliber-Nummer
2. Genauigkeit der
Zeitanzeige
3. Genauigkeit der
Tiefenmessung
4. Genauigkeit der
Temperaturmessung
Beispiel:
5.
Betriebstemperaturbereich
6.Anzeigefunktione
P
SEL
CA
40
This manual suits for next models
3
Table of contents