EXAMPLE RELAY WIRING AND TEMPERATURE SETTINGS
The G031 is designed primarily for a heating setup but can also be used for cooling. The wiring is
different depending on whether you are using the relay for a heating or cooling function.
Heating:
Connect your heating equipment to the G031 in the normal open configuration as seen in the
table below.
In the Android APP, in the ‘OTHER’ section : set your temperature ranges to the relevant relays.
Relay ON: the lowest heating activation temperature. (when colder than ‘xx‘, turn on.)
Relay OFF: the highest heater operating temperature. (if warmer than ‘xx‘, turn off.)
(The ON temperature must be at least 1°C lower than the OFF temperature.)
Cooling:
For cooling, reverse the way the relays are wired. Connect your cooling equipment in the Normal
closed configuration as seen in the table below.
It is important to understand that relays wired in ‘normal closed’ position will operate in
the opposite way than expected. In this setup off will turn the relay on. This needs to be
taken into account during setup.
In the Android APP, in the ‘OTHER’ section : set your temperature ranges to the relevant relays.
Relay OFF: the highest cooling activation temperature. (when warmer than ‘xx‘, turn on.)
Relay ON:the lowest cooling operating temperature. (if colder than ‘ xx‘, turn off.)
(The ON temperature must be at least 1°C lower than the OFF temperature.)
Example setting and wiring to maintain temperature at 25-40°C
Connected Device Heater Cooler
ON-OFF settings 25°C - 30°C 35°C - 40°C
Relay configuration
SET-UP GUIDE
 What You Need
 Installation Overview
 Notes
QK-G031 GSM REMOTE
TEMPERATURE CONTROLLER
All products are CE, RoHS certified
www.quark-elec.com
Please recycle your packaging
Blue LED - Network
YOU WILL NEED:
1. SIM card:
 SIM must operate on the GSM (2G) network for this version. Check with your SIM
supplier.
 Credit on the SIM (we recommend automatic top-ups)
 The SIM is not PIN protected
 The SIM is set to disable voicemail
 Avoid SIM cards that deactivate automatically if the SIM is not used often. If your G031 is
likely to be unused for long periods of time, you will have to send the G031 an update
request periodically to keep the SIM card active. The time limit is often three months.
2. Power supply cable: long enough to reach your device in its final location.
3. Check there is mobile network reception for your SIM card in the location that your device
will be installed (you can check the SIM card in a mobile phone).
4. Temperature sensors (included) which come in 1, 2 and 6 metre lengths and can be shortened
or extended (we recommend a maximum of 8 metres for best results).
5. Optional liquid cell 12.0V battery: Can be plugged into G031 for back up power.
QK-G031
Red LED - System
This is an overview only. Familiarize yourself with the manual and the manuals of
any connecting devices before installation. It is always recommended that
electronic equipment be installed by an experienced installer.
 Blue Network LED: LED will flash blue at start up as it is connecting to a network. Once
connected, the LED will flash once every 2 to 3 seconds.
 Red System LED: will flash at 1 second intervals once the system has finished initialization. The
LED will not flash while the G031 is processing a command.
INSTALLATION
1. Download and install the APP https://www.quark-elec.com/downloads/APPs/
2. Select G031 location: location must be indoors and not exposed to water or high humidity.
3. Connect the relay outputs (if required): check relay setup for whether you want relays in
normal open (NO) or normal closed (NC) position. See back page .
4. Connect alarm inputs (if required) to the correct terminal: alarm inputs (INT) 1/2 will activate
relay 1/2 respectively. The G031 is compatible with inputs that send signals as a switch (by closin
g the circuit) and alarm inputs that send a low voltage signal.
5. Connect temperature sensors by inserting the connector block into the slots at the back of the
G031. Good practice is to label each sensor and its corresponding relay. This will help later on.
6. Insert your SIM into the G031 device (make a note of the SIM number first for reference).
7. Connect to power: Check LEDs are working correctly.
QK-G031
8. Hold down reset button for 10 seconds.
9. Register the main phone number that will control the device within 10 minutes of powering
up the G031 by texting ‘88888888’ from your chosen phone to G031 SIM card. If registration is
successful, the module will reply with ‘Your phone has been registered’. If unsuccessful, the
module will reply with ‘registered disabled’. If registration is unsuccessful, Hold down reset
button for 10 seconds and reattempt registration within 10 minutes . The system LED will flash at
one second intervals once the registration is completed. You can add up to three additional
control mobile phones (check the manual for full list of text command codes).
OPERATION
You can send commands and receive updates by SMS text or the text generating android APP.
QUICK SMS COMMANDS
 Set the temperature limit for relays, text TEMPnxxxxtoxxxx# ’ (replace 'n' with the relay
number). Xxxx is a 4 bit signed number ranges from -055 to +125, indicating the setting
temperature. The first xxxx is the ‘switch on’ temperature and the second xxxx is for ‘switch
off’ temperature s. ON temperature must be at least 1°C lower than the OFF temperature.
 To turn relay on, text 'DKYn' (replace 'n' with the relay number).
 To turn relay off, text 'GBYn' (replace 'n' with the relay number).
 To run a relay for a short while, text 'ONOFFRnxxx#'. Replace 'n' with the relay number (1 or
2) and replace ‘xxx’ with the delay times (from 001 to 999 seconds). This is a one off
command and will not affect future actions.
 To disable the external alarm input, text 'EXTGBn' (replace ‘n’ with the relay number).
To reset all external alarm inputs, text 'EXTRT'.
 To add an additional mobile number, text 'BDn(mobile number)F', replacing 'n' with '1', '2'
or '3' according to a number of an additional mobile device.
A full list of SMS commands can be found in the manual.
Daily timer settings: Relays 1 and 2 support a daily timer function. This is useful for turning the
relays on and off without having to message the device. The relays will switch ON/OFF daily
according to the timer settings.
Remember, the device processes one command at a time. Each command will have a reply
to confirm the command has been received and executed. You must wait for a reply
message before sending another command. All SMS text commands must always be sent
using CAPITAL letters. Do not add spaces or any other characters.
Automated relay operating setting for relay 1/ 2 can be changed by adjusting the
small jumpers inside the enclosure.
 Self-lock control: When activated, the relay will stay on until it receives a different command.
 Latching control: When activated, the relay will stay on for a period of seconds, determined
by the user (3, 6, 9 or 12 seconds). It will then return to its normal state.
 When an alarm is triggered, the relay will stay locked ON until you send the
command “EXTRT” to reset alarm (even if set to latching mode).
 Temperature settings will always override alarm inputs and commands.

Other manuals for QK-G031

1

Other Quark-Elec Controllers manuals

Quark-Elec QK-G021 User manual

Quark-Elec

Quark-Elec QK-G021 User manual

Quark-Elec QK-G033 User manual

Quark-Elec

Quark-Elec QK-G033 User manual

Popular Controllers manuals by other brands

Tescom 44-4600 Series Instructions for use

Tescom

Tescom 44-4600 Series Instructions for use

Danfoss ERC 211 installation guide

Danfoss

Danfoss ERC 211 installation guide

Festo CMXR-C2 Assembly and installation

Festo

Festo CMXR-C2 Assembly and installation

Boston Acoustics GT-RSL install guide

Boston Acoustics

Boston Acoustics GT-RSL install guide

Honeywell CN100 Planning and installation guide

Honeywell

Honeywell CN100 Planning and installation guide

ISDT ESC70 user manual

ISDT

ISDT ESC70 user manual

Rutenbeck Control Plus IP4 installation instructions

Rutenbeck

Rutenbeck Control Plus IP4 installation instructions

Cisco Firepower 4100 Series Product guide

Cisco

Cisco Firepower 4100 Series Product guide

Progres Agronic instruction manual

Progres

Progres Agronic instruction manual

Calian SatService sat-nms ACU2-19V2 user manual

Calian

Calian SatService sat-nms ACU2-19V2 user manual

Siemens Acvatix SAX Series Basic documentation

Siemens

Siemens Acvatix SAX Series Basic documentation

Toshiba TE2 Series instruction manual

Toshiba

Toshiba TE2 Series instruction manual

CAME Z Series Technical documentation

CAME

CAME Z Series Technical documentation

Texas Instruments TPS2151 user guide

Texas Instruments

Texas Instruments TPS2151 user guide

YASKAWA CIMR-VC*****H**-00 series quick start guide

YASKAWA

YASKAWA CIMR-VC*****H**-00 series quick start guide

ICM Controls ICM600 Application guide

ICM Controls

ICM Controls ICM600 Application guide

Fisher 1032 instruction manual

Fisher

Fisher 1032 instruction manual

Controlli MVT5 Series Mounting instructions

Controlli

Controlli MVT5 Series Mounting instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.