On pairs 1-2, 3-6, 4-5, 7-8 and shield
5 horizontal green LED to indicate the cable pair or shield
5 vertical red LED to indicate the fault type
4 d.c. alkaline batteries, type AAA 1,5V, on main unit
01. Put switch on the right side in the ON position to turn on
02. Connect one end of the cable under test to the RJ45 jack of main LANtest unit
03. Connect the other end of the cable to the RJ45 jack of Remote LANtest unit
04. Press TEST to run the test and display the results
05. The horizontal LEDs indicate the status of the integrity of the cables
Green-> Pairs or shield correct
Blinking green -> Pair or shield not correct
No light -> Open pair or unshielded cable
06. The vertical LEDs indicate link failures, and battery status
The faults detected ccould be:
−Shorts
−Opens
−Incorrect connections
−Reversed pairs
−Split pairs
07. To locate a fault on a specific pair, use the diagnostic feature of LANtest
08. Press and hold TEST for more than 2 seconds; LANtest scans of each pair and the shield, flashing each LED separately. If a fault pair is
found, the corresponding error status is indicated by flashing of red LED
Note: Once the tests is finished, snap the Remote unit on LANtest main unit. This configuration allows also to easily test patch cords.