Description
LANtest is a handheld tool that allows network professionals to quickly and easily check the integrity of balanced twisted-pair cables and
connections in Ethernet networks. In one step LANtest checks: opens, shorts, reversed pairs, crossed and split pairs in balanced twisted
pair cables. Just put the switch in the On position, press the TEST button and LANtest automatically scans the pairs, looking for mistakes
and failures. The remote unit allows for an accurate verification of the connections in data networks.
Packaging
−1 Lantest
−1 LANtest REMOTE
−Patch cord RJ45-RJ45
−User manual
−Protective case
Functionality
•It checks the nonconformity of cables, jacks, plugs and connections and detects: opens, shorts, crossed pairs, reversed pairs and split
pairs (to identify split pairs it requires a minimum cable length of 40 cm)
•It checks the integrity of the shielding
•The remote identifier allows a precise identification of the causes of anomalies
•Easy to read fault indicator (LED) and very rapid test
•Auto standby mode to reduce power consumption
Batteries
LANtest runs on 4 AAA alkaline batteries of 1.5 volts. The battery LED will light when it detects the condition of low batteries.
The use of LANtest with low batteries can affect the accuracy of tests. If LANtest is not used for over a month it’s better to remove the
batteries.
Recommendations
Do not connect LANtest to active circuits, the 2 units could be damaged. Radio frequency electromagnetic fields of high intensity can
cause erroneous readings. Do not open the two units or try to repair them in case of failures.
In case of malfunction, return the instrument to a local distributor by filling out the type of fault founded.
Pair and shield
LED
TEST botton
Remote unit
Switch ON-=OFF
Fault LED
Battery LED
Qubix SpA
Product Code :
2040039
Description :
LAN TEST
QUBIX S.p.A. Networking solutions –Via Canada, 22/A –35127 Padova –Italy
Tel. +39 049 7801994 –Fax +39 049 775667 –http://www.qubix.it
Rev. 05-12
Qubix S.p.A. si riserva di apportare modifiche e migliorie in qualsiasi momento senza preavviso
Qubix S.p.A. reserves the right to make changes and improvements at any time without notice
Specifications
Connector
RJ45 on main and remote units
Checking
On pairs 1-2, 3-6, 4-5, 7-8 and shield
Display LED
5 horizontal green LED to indicate the cable pair or shield
5 vertical red LED to indicate the fault type
Cable length
Minimum 40 cm –Maximum 200 mt
Power
4 d.c. alkaline batteries, type AAA 1,5V, on main unit
Dimensions
Main unit 125x52x39 mm
Remote unit 47x28x22 mm
Weight
125 g
Test procedure
01. Put switch on the right side in the ON position to turn on
02. Connect one end of the cable under test to the RJ45 jack of main LANtest unit
03. Connect the other end of the cable to the RJ45 jack of Remote LANtest unit
04. Press TEST to run the test and display the results
05. The horizontal LEDs indicate the status of the integrity of the cables
Green-> Pairs or shield correct
Blinking green -> Pair or shield not correct
No light -> Open pair or unshielded cable
06. The vertical LEDs indicate link failures, and battery status
The faults detected ccould be:
−Shorts
−Opens
−Incorrect connections
−Reversed pairs
−Split pairs
07. To locate a fault on a specific pair, use the diagnostic feature of LANtest
08. Press and hold TEST for more than 2 seconds; LANtest scans of each pair and the shield, flashing each LED separately. If a fault pair is
found, the corresponding error status is indicated by flashing of red LED
Note: Once the tests is finished, snap the Remote unit on LANtest main unit. This configuration allows also to easily test patch cords.
Fault types
4 batterie
c.c. alcaline
tipo AAA da
1,5V su
unità
principale
4 batterie
c.c. alcaline
tipo AAA da
1,5V su
unità
principale
4 batterie c.c.
alcaline tipo
AAA da 1,5V
su unità
principale
4 batterie
c.c. alcaline
tipo AAA da
1,5V su unità
principale
4 batterie
c.c. alcaline
tipo AAA da
1,5V su unità
principale
Qubix SpA

Popular Test Equipment manuals by other brands

BIRD 4029 Instruction book

BIRD

BIRD 4029 Instruction book

Apera Instruments GroStar GS3 Premium user manual

Apera Instruments

Apera Instruments GroStar GS3 Premium user manual

AMS SCRAM Quick reference guide

AMS

AMS SCRAM Quick reference guide

SIGLENT SDS1000CML series quick start

SIGLENT

SIGLENT SDS1000CML series quick start

BGS technic 62660 quick start guide

BGS technic

BGS technic 62660 quick start guide

Medivators VERISCAN LT user manual

Medivators

Medivators VERISCAN LT user manual

Factair F6001 operating manual

Factair

Factair F6001 operating manual

Metz Connect Kapri Plus user manual

Metz Connect

Metz Connect Kapri Plus user manual

EnOcean EPM 300 user manual

EnOcean

EnOcean EPM 300 user manual

Neware CE-6000n user manual

Neware

Neware CE-6000n user manual

LeCroy WAVESURFER Operator's manual

LeCroy

LeCroy WAVESURFER Operator's manual

Kurth KE3600 Firmware update instructions

Kurth

Kurth KE3600 Firmware update instructions

DACE OMEGA-HB instruction manual

DACE

DACE OMEGA-HB instruction manual

ACECO FC5002 quick start guide

ACECO

ACECO FC5002 quick start guide

Amprobe AM-42 user manual

Amprobe

Amprobe AM-42 user manual

JDS Uniphase TestifierPRO user guide

JDS Uniphase

JDS Uniphase TestifierPRO user guide

Silverline 282625 user manual

Silverline

Silverline 282625 user manual

Dräger Alcotest 9510 Technical manual

Dräger

Dräger Alcotest 9510 Technical manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.