Automatic Closure Time After the open ng the gate wa ts for F0 seconds before beg nn ng the clos ng. To d sable the automat c closure set
F0 = St. To set St hold down or keep press ng button C unt l the d splay shows St.
F0
Pedestrian Time A pedestr an command opens the gate for F1 seconds.
F1 s settable from 00 to A1.
F1
Kick Back Function
During Closing
When the gate s clos ng and the slowdown s f n shed, a ramp pulse s executed by motor. Th s pulse s F2
seconds long and the obstacle detect on sensor s d sabled for the same amount of t me. After the pulse the clos ng
phase s f n shed. F2 s settable from 0.0 to 2.5 seconds
F2
Pre-blinking Time Before start ng the motor, the flash ng lamp bl nks for F3 seconds. After th s t me the flash ng lamp st ll bl nks and
the motor start mov ng. F3 s settable from 0.0 to 5.0 seconds
F3
Kick Back Function
During Opening
F4 = SI → ENABLED F4 = no → DISABLED
Before open ng motor closes for 0.5 seconds. The force of the motor A s set to max mum power and the obstacle
detect on s d sabled. Th s funct on can be useful when the electr c lock s nstalled and open ng s d ff cult.
F4
Start Commands
Functionality
STANDARD F6 = no and F5 = no
During the opening: The start
commands stop the open ng.
During the closing : The start
commands stop the clos ng and beg n
the open ng.
COMMUNITY MODE F6 = SI
During the opening :The start
commands don't have any effect.
During the closing :The start commands
stop the clos ng and beg n the
open ng.
STEP-BY-STEP F6 = no and F5 = SI
During the opening : The start
commands stop the gate.
During the closing The start
commands stop the gate.
F5
F6
Rapid Closure delay During the opening: once all photocells have been act vated, both nternal and external, the gate starts
clos ng after F7 seconds. The fast closure s allowed only f gate has been started by a remote stored through
r4 funct on. F7 s settable from 1.5 to 5.0 seconds.
F7
Photocells Logic F8 = SI → STANDARD MODE
During the opening: If the internal photocell s
act vated the control board stops the open ng and
starts the clos ng. After 3 seconds the closure s
stopped and the control board state s stop-
open ng. The act vat on of the external photocell
doesn't have any effect Instead.
During the closing: If the external photocell s
act vated the control board stops the clos ng and
starts the open ng.The act vat on of the internal
photocell doesn't have any effect nstead.
F8 = no → REVERSE MODE
During the opening: Wh le the internal photocell s act vated
the control board stops the open ng. When the internal
photocell s deact vated the control board cont nues the
open ng. The act vat on of the external photocell doesn't have
any effect nstead.
During the closing:If the external photocell s act vated the
control board stops the clos ng and starts the open ng.
If the internal photocell s act vated the control board stops the
clos ng and wa ts for the open ng. The open ng starts only
when the internal photocell s deact vated.
F8
Before the gate starts the o ening hase:
f E3 = tC : The open ng cannot be starte d f external photocell s detect ng an obstacle. ← SAFER SETTING
f E3 = td : The open ng can be started even f external photocell s detect ng an obstacle.
Electric Lock L0 = SI → ENABLED
The electr c-lock module s managed. The module
must be nstalled on the electr c-lock socket.
L0 = no → DISABLED
The electr c-lock s not managed. The module s not nstalled
on the electr c-lock socket.
L0
Cold Winter
L1
The cold winter funct on s useful n countr es w th very cold w nters. The motor s act vated w th the m n mum
power for L1 m nutes out of 10 m nutes to keep the control board box and the motor warm. When the motor s
act vated w th the m n mum power, the gate doesn't move. The funct on runs when the gate s completely open or
n stand-by only. When L1 s set to 00 the funct on s d sabled. L1 s settable from 00 to 10.
Assistance Request
from cycle counter
L5 = no → DISABLED
When the gate has completed L5 work ng cycles, the d splay shows 5L. Each 20 m nutes the flash ng lamp s on
for 1 m nutes. Th s funct on s useful for programm ng ass stance request. L5 s programmable from A.1 to G.9.
The letter s the mult pl er of the number A (x 1) , B (x 10) , C (x 100), D (x 1 000), E (x 10 000) , F (x 100 000) and G
(x 1 000 000). In th s way you can program assistance request function from: 1-9 (A), 10-90(b) , 100 – 900 (C) ,
1000 – 9000 (d) , 10 000 – 90 000 (E) , 100 000 – 900 000 (F) , 1 000 000 – 9 000 000 (G) work ng cycles.
L5
Working Cycle Counter It s the total work ng cycle counter. The d splay shows a letter and a number. The letter s the mult pl er of the
number: A (x 1) , B (x 10) , C (x 100), D (x 1 000), E (x 10 000) , F (x 100 000) and G (x 1 000 000).
For instance f a gate has completed 1365 work ng cycle then L6 shows d.1. Press ng button D the d splay shows
the complete value:
d.1 C.3 b.6 A.5
1 6 5
L6