Quilo AVIANCE QE2RIVKG User manual

4- IN- 1 ALL SEASON AIR CLIMATIZER
CLIMATISEUR D’AIR TOUTES SAISONS 4-EN-1
CLIMATIZADOR DE HABITACIÓN 4 EN 1 PARA TODAS LAS ESTACIONES
4-IN-1 ALLE-SEIZOENEN KAMER KLIMAATREGELAAR
4-IN-1 RAUMKLIMAGERÄT FÜR JEDE JAHRESZEIT
KLIMATYZATOR POKOJOWY 4 W 1 NA CAŁY SEZON
User Manual
Read these instructions before use and
Keep the manual safe for future reference
Mode d'emploi
Lire ces instructions avant l'utilisation et
Les conserver
Manual de Usuario
Lea y guarde estas instrucciones antes de
Usar la unidad
Gebruiksaanwijzing
Lees de gebruiksaanwijzing zorgvuldig en
Bewaar deze goed
Benutzerhandbuch
Lesen sie die anleitung vor dem gebrauch und
Heben sie sie auf
Instrukcja obsługi
Przeczytaj i zachowaj tę instrukcję przed użyciem
EN
FR
ES
NL
DE
PL

1EN
THANK YOU
USER TIPS
Congratulations on your purchase of the versatile QUILO® AVIANCE™.
With 4 functions in 1 device, AVIANCE™ helps to provide comfort all year long:
• Air purifier – Removes up to 99.5%* of airborne particles up to 0.3* microns. Helps
minimize the spread of allergens and bacteria in the air, such as pollen, smog, and
viruses.
• Fan - Circulates the room air and provides ventilation.
• Evaporative Cooler - Transforms warm, dry air into moist, cool air during warmer
months. See below for a detailed description of evaporative cooling.
• Humidifier - Helps counteract static air and irritating dryness during autumns and
winters.
What is Evaporative Cooling?
QUILO® AVIANCE™ Evaporative Cooler is built to maximize energy efficiency and keep
energy costs low. Warm air is drawn into the cooler and enters the Honeycomb Cooling
Media. Water pumped from the water tank pours over the Honeycomb Cooling Media. As
the warm air passes through the Honeycomb Cooling Media, the water absorbs the heat,
naturally cooling and humidifying the air. A fan propels the cooled air out into the room. This
no-compressor system cools naturally, efficiently, and inexpensively.
Water
The recommended maximum relative humidity level is 60%* or less, which allows a noticeable
temperature decrease. The temperature will be lower in drier climates because higher
evaporation occurs when the humidity is low.
NOTE
When the product is used for the first time the Honeycomb Cooling Media will have an odor
which will dissipate in a few hours or so of initial use.
Cool Air
Honeycomb
Cooling Media
Carbon Dust
Filter
Warm Air

2EN
PURIFICATION SYSTEM
1: Efficient HEPA Filter
Removes up to 99.5%* of airborne particles up to 0.3* microns. Helps minimize the spread of
allergens and bacteria in the air, such as pollen, smog, and viruses.
2: Activated Carbon Filter
Removing volatile organic compounds, such as secondhand smoke and kinds of polluting
gases.
3: UV light sanitization
Effectively kills up to 99.96%* of common bacteria and viruses by inducing changes in their
DNA.
HEPA Filter Activated Carbon Filter

3EN
SET UP
To maximize efficiency, position the QUILO® AVIANCE™ according to the following guidelines:
Cooling
For the maximum cooling effect, place the unit in front of an open door or window. Ensure
that there is adequate cross-ventilation in the room by leaving a door or window open
opposite the cooler.
QUILO® AVIANCE™ must be kept level and there must be sufficient water in the tank. Doors
and windows should be opened to allow free airflow. The QUILO® AVIANCE™ works best when
placed near an open window, so that outside air is drawn into the unit, circulates in the room,
then exits via the door. The maximum cooling effect is felt when a person is near the flow of
air coming out of the unit.
Humidification
The QUILO® AVIANCE™ produces moist air through the evaporative cooling process and can
be used to humidify dry air. When the device is to be used for humidification, it must be
ensured that the windows and doors are closed.
Air Purification
To ensure that your room air is purified properly on both sides of the cycle, please make sure
that the gap between the air inlet and the wall is at least 50 cm and the gap to the air outlet
is at least 30 cm. Please keep the device at least 1 meter away from television, radio, etc.
Please do not insert the power plug in the same socket as the television, radio, and other
electrical devices to avoid any electrical interference on the other devices.
Keeping the device placed at the same spot for a long time may result in the walls near the
device getting dirty.
To ensure that the device has adequate ventilation and works with maximum efficiency,
please keep it away from anything that might cause interference with the air inlet or outlet.

4EN
SAFETY RULES
WARNING — READ AND SAVE THE USER MANUAL
The QUILO® AVIANCE™ User Manual is intended to provide important information needed to
set up, operate, maintain and troubleshoot your QUILO® AVIANCE™. Failure to follow these
instructions may damage and/or impair its operation, create hazards, and void the warranty.
In case there is any inconsistency or conflict between the English version and any other
language version of the content of this material, the English version shall prevail.
When using electrical appliances, basic safety precautions should always be followed.
Note: Always ensure the water tank is filled with water above the ‘Min’ level mark when
operating the unit in the evaporative cooling & humidification modes.
WARNING – Skin or eye damage may result from directly viewing the light produced by the
lamp in this apparatus.
CAUTION! -This equipment should be inspected frequently and collected dirt removed from
it regularly to prevent excessive accumulation that may result in flashover or a risk of fire.
WARNING: Disconnect power supply before servicing.
This product complies with the maximum allowable concentration of ozone of 0.050 parts
per million by volume (0.001ppmv) in a 24-hour period. The Health Canada Guideline 2010
recommends that the maximum exposure limit, based on an average time of 8 hours, is 0.020
ppmv or less when tested in a sealed, controlled room of approximately 30 m3size.
WARNING: RISK OF ELECTRIC SHOCK – These servicing instructions are for use by
qualified personnel only. To reduce the risk of electric shock, do not perform any servicing
other than that contained in the operating instructions unless you are qualified to do so.
To reduce the risk of electric shock, this equipment has a grounding-type plug that has a
third (grounding) pin. This plug will only fit into a grounding-type power outlet. If the plug
does not fit into the outlet, contact qualified personnel to install the proper outlet. Do not
alter the plug in any way.

5EN
SAFETY RULES (CONTINUED)
WARNING:
• Unplug power supply before servicing.
• This appliance contains a UV emitter. Do not stare at the light source.
• This appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and knowledge
if they have been given supervision or instruction concerning use of the appliance
in a safe way and understand the hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall not be made by children without
supervision.
• Be aware that high humidity levels may encourage the growth of biological organisms
in the environment.
• Do not permit the area around the humidifier to become damp or wet.If dampness
occurs, turn the output of the humidifier down. If the humidifier output volume cannot
be turned down, use the humidifier intermittently. Do not allow absorbent materials,
such as carpeting, curtains, drapes, or tablecloths, to become damp.
• Unplug the appliance during filling and cleaning.
• Never leave water in the reservoir when the appliance is not in use.
• Empty and clean the humidifier before storage. Clean the humidifier before next use.
• Keep the appliance out of the reach of children. Steam and boiling water may cause
burns.
• This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
• Children should be supervised to ensure that they do not play with the appliance. If the
supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.
• The method, frequency of cleaning, and necessary precautions to be taken.
• This appliance contains a UV-C emitter.
• Unintended use of the appliance or damage to the housing may result in the escape of
dangerous UV-C radiation. UV-C radiation may, even in little doses, cause harm to the
eyes and skin.
• Appliances that are obviously damaged must not be operated.
• The replacement of the UV-C emitter by the user is not allowed.
• Check the household voltage to ensure it matches the appliance’s rating specifications.
• Before operating the product, remove the packaging and check that product is in good
condition.
• DO NOT operate with a damaged cord or plug.
• DO NOT use an extension cord with this unit.

6EN
SAFETY RULES (CONTINUED)
• DO NOT run power cord under carpeting, or cover it with rugs or runners. Keep the cord
away from areas where it may be tripped over.
• Always unplug the QUILO® AVIANCE™ before refilling the water tank, cleaning, servicing,
or relocating the unit.
• Never pull the cord. Remove it from the electrical outlet/ socket by grasping and pulling
on the plug-end of the cord.
• Be aware that high humidity levels may encourage the growth of biological organisms
in the environment.
• Never leave water in the reservoir when the appliance is not in use.
• Empty and clean the machine and dryer 3 cartridges before storage. Clean the machine
& cartridges before next use.
• Keep the appliance out of the reach of children. Steam and boiling water may cause
burns.
• Children should be supervised to ensure that they do not play with the appliance.
• Appliances that are visibly damaged must not be operated.
• This appliance has been manufactured for use in domestic environments and must not
be used for other purposes.
• DO NOT use in areas where gasoline, paint, or other flammable goods and objects are
stored.
• When using the Cool & humidify Mode setting, make sure the water in the tank is above
the Min. water level mark in the tank. Operating the unit on the Cool & humidify mode
setting with an empty tank may result in damage to the water pump.
• DO NOT attempt to repair or adjust any electrical or mechanical functions of the QUILO®
AVIANCE™, as this may void the warranty.
• DO NOT cover the unit air inlet or outlet, as this may damage the motor.
• DO NOT insert or allow objects to enter any ventilation or exhaust opening, as this may
damage the unit and may cause electrical shock or fire.
• DO NOT leave the operating appliance unattended for an extended period of time.
• DO NOT allow children to play with this appliance, packaging, or plastic bags.
• DO NOT continue to operate the unit if it is damaged or if it malfunctions. Refer to the
TROUBLESHOOTING section and contact the CUSTOMER SUPPORT CENTER.
• Always place the unit on a dry level floor.
• DO NOT use in bathrooms or near water. DO NOT keep the product where it may fall
into a water container.
• Store in a dry area when not in use.
• Always grip the side handles to move the QUILO® AVIANCE™.
WARNING: To reduce the risk of fire or electric shock, do not use this appliance with any solid
state speed control device.

7EN
SECURITY NOTE
To avoid possible damage to you or others or financial damages, please be sure to pay
attention to the following safety precautions.
Warning
If the machine's power supply cord is damaged, you must ensure that the manufacturers
of the machine, maintenance service center or qualified technicians replace it to avoid any
potential hazard.
Don’t touch the power plug
with wet hands.
Before cleaning the appliance,
please make sure have power off.
Before start the machine,
please insert the plug
completely into the socke.
Please clean the power plug
regularly.
Do not insert rods or other metal
objects in the air outlet or inlets.
Do not plug in the device
on an electrical socket with
greater than the specified
output.
Do not damage the power
cable and socket.
Do not disassemble or
modify the device on your
own.
No wet
hands!
Pull the
plug!
Caution
Caution
Caution Caution
Otherwise, it may cause the risk
of an electric shock.
Otherwise, machine may run suddenly,
causing the risk of getting an electric shock.
Failure to fully insert the plug into the socket
may cause an electric shock and the risk
of overheating or fire hazard.Do not use a
damaged plug or loose power socket
Using a universal socket or a socket
exceeding the specified value of the
equipment may cause overheating
and a fire hazard.
In the use of the machine, don't bind,
wires. Using a broken wire may cause
an electric shock, short circuit, or fire
hazard.
Do not cut, modify, excessively distort,
twist, pull, or put any weight on the
wires or plugs.
Otherwise it may cause electric shock,
failure, or fire accident.
Otherwise, it may affect the internal parts
and cause electric shock or damage
Accumulation of dust or moisture on the
power plug can damage the insulation,
resulting in a fire hazard.
Pull out the power plug, then wipe with a dry
cloth (do not use a wet cloth).
Remember to remove the power plug from
the socket if it is not used for a long time.

8EN
SECURITY NOTE (CONTINUED)
Attention
In case any of the below mentioned situations occur, please power off the machine
immediately:
• A switch does not work.
• A circuit breaker or fuse burned.
• The power cord or plug abnormal fever. Finding the burning odor or abnormal sound
or vibration.
• Any other anomalies or failure.
Do not use solvents such as
benzene or thinners to clean
the machine and avoid
spraying the device with
insecticides.
Do not insert metal or hard
objects into the inlet &
outlet.
Do not use the air
purifier(installed HEPA
cartridge)indoor when the
room has been sprayed with
insecticides or pesticides.
While pulling out the power plug,
hold the plug, instead of pulling
the wires.
Do not use the device in areas
where it might get damp or wet
such as the bathroom.
Away
from
the fire
No
wet!
Otherwise, the machine may rupture
and get damaged or short circuit,
which may cause an electric shock or
a fire hazard.
Such as inside the kitchen, can reduce
the service life of air purifier filter.
The air purifier (installed HEPA
cartridge) should not be used as
ventilation or extraction equipment
Otherwise, it may cause a short circuit and
cause fire or electric shock, or injury.
The machine may short circuit causing an
electric shock or fire hazard.
Do not keep volatile substances
or combustible materials, such as
tobacco near the machine.
Keep the device away from any fire or fire
causing substances to avoid any fire risk
Chemical residue could be
accumulated inside the machine,
and then released from the outlet to
cause a health hazard.
After using insecticides or pesticides,
please thoroughly ventilate the room
before using
Caution
Caution
Banned!

9EN
WARNING - Read the manual before using this product and save it for future reference.
Failure to follow these instructions may damage and/ or impair its operation
and void the warranty. in case there is any inconsistency or conflict between the english
version and any other language version of the content of this material, the english version
shall prevail.
1. Ice Compartment
2. Handle
3. Smart Sensors Detect
4. Castors
5. Drain Plug
6. Touch Control Panel
PARTS DESCRIPTION
7. Louvers
8. Water Level Indicator
9. Rear Grill
10. Water Tank
1
5
7
6
10
8
9
3
2
4

10 EN
USE & OPERATION
CONTROL PANEL
Icons on Display Screen
BUTTON FUNCTIONS
When the machine is connected to the power supply, the unit will detect which cartridge has
been selected.
WARNING: Before turning on the unit, please select one of the cartridges to start the
operation.
When Honeycomb is used, “HC” letter will be displayed on the display screen and icon will
light up along with a beep.
When Humidify PP Filter is used, “HU” letter will be displayed on the display screen and
icon will light up along with a beep.
When HEPA is used, “HP” letter will be displayed on the display screen and icon will light
up along with a beep.
Note: When there are no cartridges installed, the number ‘888’ will be displayed on the
display screen and the power button will not work.

11 EN
USE & OPERATION (CONTINUED)
WHEN HONEYCOMB IS USED:
Power Button/ Power or ION Button :
Press the button to turn the unit on. The unit will start automatically at medium speed.
After a few seconds the speed will switch to low. Once the unit is switched on, the Ionizer#is
automatically activated. Ionizer reduces particles in the air. To turn the unit and Ionizer#off,
press the button again.
When the icon light is on, this means that evaporative cooling is activated. The water
pump will operate and you will feel the cooler air after the Honeycomb Cooling Media is
completely wet.
When icon light is flashing, it is a reminder to the user to fill/refill the tank with water.
Speed Button :
Press button repeatedly to change the speed between LOW-HIGH-MID-LOW.
The indicator light will show the selected speed.
Press button for 3 seconds to select your desired wind type:
+ or + (Variable). The indicator light will show the selected wind type.
+ : The fan speed alternates between High, Middle, Low and Off to mimic a natural
breeze.
+ : This mode is for comfort during the night. When the SLEEP mode is selected, the
airflow will randomly vary between High, Middle,Low as below.
+ : Running at High speed for 30 mins, then change to middle speed for 30mins, and
then Low speed until the unit is switched off.
+ : Running at middle speed 30mins then change to low speed until the unit is switched
off.
+ : Running at low speed until the unit is switched off.
Swing Button :
Vertical air direction - Press the button and ‘SWING’ indicator light will turn on and the
louvers will begin to move left to right automatically. Press button again, the louver will
stop moving and the indicator light will turn off. Horizontal Air direction- You can manually
adjust the louvers to change the horizontal airflow.

12 EN
USE & OPERATION (CONTINUED)
Timer Button :
Press the button, the display screen will display 0 hr, press the button once again,
and the time increases by 1hr until the desired time duration setting is selected. When the
set time has passed, the unit will automatically turn off. The TIMER function allows you to
program the unit up to 8 hours.
UV Button :
Press button to turn on the UV light, press the button again to turn off the UV light.
Mode Button :
When the water in the tank is above the minimum level, press the button to control
cooling with the cooling icon lights on or off.
When the water in the tank is below the minimum level, press the button and the cooling
icon light will flash with a beep.
Press the button again to deactivate.
Auto Button :
Press the button to run the unit in Auto mode as explained below:
When temperature is ≤20°C (68°F), the unit runs at low speed, when the temperature is
between > 21~25°C (70~77°F), the unit runs at mid speed, when temperature >25°C(77°F), unit
runs at high speed.
When the water in the tank is above the minimum level, and when the detected humidity
level is less than the last humidity setting, the water pump works automatically.
When the detected humidity level is more than the last humidity setting, the water pump
stops working automatically.
Press the button again to quit Auto mode.
Humidity Setting :
Press the button for 3 seconds to change the Humidity setting. The humidity data is
displayed on the display screen and flash, and the % indicator light is on.
Press the MODE button to increase the humidity setting by 5%, Press the TIME button to
reduce the humidity setting by 5%. The humidity can be set in the range of 40% ~70%RH.

13 EN
USE & OPERATION (CONTINUED)
WHEN HUMIDITY PP FILTER IS USED:
Power Button/ Power or ION Button :
Press the button to turn the unit on. The unit will start automatically at medium speed.
After a few seconds the speed will switch to low. Once the unit is switched on, the Ionizer#is
automatically activated. Ionizer reduces particles in the air. To turn the unit and Ionizer#off,
press the button again.
When icon light is on, this activates the humidity function.
When icon light flashes, it reminds the user to fill/refill the tank with water.
Speed Button :
When the water in the tank is above the minimum level, fan speed will be locked at low
speed.
When the water in the tank is below the minimum level, the speed button operates as below :
Press the button repeatedly to change the speed between LOW-HIGH-MID -LOW. The
indicator light will show the selected speed.
Press the button for 3 seconds to select your desired wind type:
+ : + (Variable). The indicator light will show the selected wind type.
+ : The fan speed alternates between High, Middle, Low, and Off to mimic a natural
breeze.
+ : This mode is for comfort during the night. When the SLEEP mode is selected, the
airflow will randomly vary between High, Medium, Low as below.
+ : Running at High speed for 30 mins, then change to middle speed for 30mins, and
then Low speed until the unit is switched off.
+ : Running at mid speed 30mins then change to low speed until the unit is switched off.
+ : Running at low speed until the unit is switched off.
Swing Button :
Vertical air direction - Press the button and the SWING indicator light is on, the louvers
will begin to move left to right automatically. Press button again, the louver will stop to
move and the indicator light will turn off. Horizontal Air direction- You can manually adjust the
louvers to change horizontal air flow.

14 EN
USE & OPERATION (CONTINUED)
Timer Button :
Press the button, the display screen will display 0 hr, press the button once again,
and the time increases by 1hr until the desired time duration setting is selected. When the
set time has passed, the unit will automatically turn off. The TIMER function allows you to
program the unit for up to 8 hours.
UV Button :
Press button to turn on UV light, Press button again to turn off the UV light.
Mode Button :
When the water in the tank is above the minimum level, humidify led light automatically
turns on and the pump starts working. Press the button again and the humidify led light
will turn off and the pump stops working.
When the water in the tank is below the minimum level, humidify light automatically turns
off, and the pump stops working.
Press the button again to deactivate.
Auto Button :
Press the button to get the unit running in Auto mode as below :
When the water in the tank is above the minimum level and when the detected humidity level
is less than the last humidity setting,the water pump works automatically.
When the detected humidity level is more than the last humidity setting, the water pump
stops working automatically.
Press the button again to quit Auto mode.
Humidity Setting :
Press the button for 3 seconds to change the Humidity setting. Initially, 55%RH is
displayed on the display screen, and the % indicator light flashes.
Press the MODE button to increase the humidity setting by 5%, Press the TIME button to
reduce the humidity setting by 5%. The humidity can be set in the range of 40%RH~70%.

15 EN
USE & OPERATION (CONTINUED)
WHEN HEPA CARTRIDGE IS USED:
Power Button/ Power or ION Button :
Press the button to turn the unit on. The unit will start automatically at medium speed.
After a few seconds the speed will switch to low. Once the unit is switched on, the Ionizer#is
automatically activated. Ionizer reduces particles in the air. To turn the unit and Ionizer#off,
press the button again.
When icon light is on, this activates the air purification function.
Speed Button :
Press the button repeatedly to change the speed between LOW-HIGH-MID-LOW. The
indicator light will show the selected speed.
Press the button for 3 seconds to select your desired wind type:
+ – + (Variable). The indicator light will show the selected wind type.
+ : The fan speed alternates between High, Mid, Low, and Off to mimic a natural
breeze.
+ : This mode is for comfort during the night. When the SLEEP mode is selected, the
airflow will randomly vary between High, Medium, Low as below.
+ : Running at High speed for 30 minutes, then change to mid speed for 30mins, and
then Low speed until the unit is switched off.
+ : Running at mid-speed for 30 minutes then change to low speed until the unit is
switched off.
+ : Running at low speed until the unit is switched off.
Swing Button :
Vertical air direction - Press the button and the SWING indicator light is on, the louvers
will begin to move left to right automatically. Press the button again, the louver will stop
moving and the indicator light will turn off
Horizontal Air direction- You can manually adjust the louvers to change the horizontal airflow.
Timer Button :
Press the button until the desired time duration setting is selected. When the set time
has passed, the unit will automatically turn off (the unit remains in Standby mode until
the power cord is unplugged from the electrical socket). The TIMER function allows you to
program the unit for up to 8 hours of use.

16 EN
USE & OPERATION (CONTINUED)
Power
UV light
Fan Speed
Natural/Sleep
Swing
Auto
Mode
Timer
ON/OFF
UV light ON/OFF
Low/Middle/High
Natural/Sleep
Controls the Motion of the Louvers/
Humidity Setting
Auto mode
Cooling mode/HumidificationMode/
Air Purification mode/Adjust humidity setting
Controls the timer function for
Automatic off/Adjust humidity setting
:
:
:
:
:
:
:
:
REMOTE CONTROL
Mode Button : Deactivate
Humidity Setting : Deactivate
Auto Button :
Press button, Auto button LED light is on, unit running at Auto mode as below :
PM2.5 in the range of 0~50, runs at low speed, PM2.5 >50~100, runs at mid speed, PM2.5 >100,
runs at high speed.
UV / HEPA Cartridge Alert :
Press button to turn on UV light, Press again to turn off UV light.
When the life cycle of HEPA expires, LED light will flash to remind the user to replace it. Once
HEPA is replaced, press button for 3 seconds and the unit will record the expiration date of the
new HEPA.

17 EN
NOTE:
Humidity Setting:
Press button for 3 seconds to adjust the humidity setting. Press button and press
to adjust the humidity setting for 40%RH~70%.
Mode+ :
When cartriage is used, press button to select the mode. You can select the
corresponding mode according to the icon displayed on the remote control but the display
Icon on control panel must be same as the display icon on remote control.
NOTE:
• The remote control requires two AAA (2 x 1.5 V) batteries or equivalent battery for
replacement.
• Open the battery compartment at the back of the remote control and insert the battery
inside. Care must be taken to insert the batteries according to the correct polarity (+ / –)
markings shown inside the battery compartment.
• Always point the remote control signal transmitter towards the unit when operating.Make
sure that the signal path is not obstructed.
• Remove the batteries if the unit is not going to be used for an extended period of time.
• Do not drop the remote control.
• Do not mix different types of batteries such as alkaline, carbon-zinc, or rechargeable
batteries.
• Do not mix old and new batteries.
• Do not recharge the battery.
• Exhausted batteries are to be removed from the product and safely disposed of as per
local regulations.
• Do not dispose of batteries in fire. Batteries may explode or leak.
• If the battery compartment does not close securely, stop using the product and keep it
away from children.
• If you think batteries might have been swallowed or placed inside any part of the body,
seek immediate medical attention.
• The batteries contain materials, which are hazardous to the environment; they must be
removed from the appliance before it is scrapped and that they are disposed of safely.
WARNING: Caution for ingestion of the small battery. Keep away from children and
animals.
WARNING: Chemical Burn Hazard. Keep batteries away from children.See Manual.
This product contains a lithium button/coin cell battery. If a new or used lithium button/coin
cell battery is swallowed or enters the body, it can cause severe internal burns and can lead
to death in as little as 2 hours. Always completely secure the battery compartment. If the
battery compartment does not close securely, stop using the product, remove the batteries,
and keep it away from children. If you think batteries might have been swallowed or placed
inside any part of the body, seek immediate medical attention.
WARNING: Even used cells may cause injury.
USE & OPERATION (CONTINUED)

18 EN
USE & OPERATION (CONTINUED)
CAUTION:
Remove the power cord from the unit and the electrical
outlet before emptying or refilling the water tank.
Note: Water tank is semi-detachable design
Slide out the Water Tank. Refill the tank when the water
level is low.
Do not fill water above the "Max." The Max water level
mark to avoid water spilling out when moving the
machine. Check the water level in the tank before running
the Cool & humidify Mode function.
The Low Water Alarm will sound when water is low.
Running the unit in Cool&humidity Mode with
inadequate water may cause pump failure.
If ice is available, you may add ice in the top ice
compartment to enhance the cooling performance.
Note: The water capacity refers to the total volume of
water that can be contained within the air cooler water
tank and water distribution system. The water capacity in
the tank at the “Max.” indicator
level may be lower than the actual water capacity of the
air cooler.
WARNING: Do not fill the water tank with dirty water or
salt water. This can damage the unit and Honeycomb
media.
FILLING WITH WATER & ICE (COOL & HUMIDIFY MODE)
Ice compartment
Semi-Detachable
Water Tank
for Easy Tank Refill

19 EN
USE & OPERATION (CONTINUED)
LOW WATER ALARM
The unit is equipped with a low water sensor. In & Mode, when water in the tank is
below the minimum level, you will hear 10 times alarm sounds, and the indicator light will flash
continuously. The unit will automatically pause evaporative cooling & humidification.
Refill the water tank to deactivate the alarm in cool & humidity Mode.
First switch OFF the unit and unplug from the electrical socket. Fill the water tank with water
above the minimum water level mark. Plug in and switch it ON again.
To deactivate the alarm and continue using the unit as a fan (without evaporative cooling &
humidification), switch the unit OFF and then ON again. The Low Water Alarm will activate and
keep running at Fan mode.
CLEANING & DRAINING THE WATER TANK
Warning:
Before cleaning the unit, switch the unit OFF and disconnect from the electrical socket.
• Use a damp cloth to remove dirt and dust from the surface of the unit. Never use corrosive
elements or chemicals to clean this product.
• When the product is not in use, store the unit in a dry place out of direct sunlight.
• Do not put the product into water or any other liquid. Do not use corrosive or flammable
gas(e.g. bleach or alcohol) to clean any part of the product.
CLEANING THE CARBON DUST FILTER/ HONEYCOMB COOLING CARTRIDGE/
HUMIDITY PP FILTER CARTRIDGE
WARNING:
Before cleaning the unit, switch the unit OFF and disconnect the power cord from electrical
socket.
CAUTION: HEPA CARTRIDGE CAN NOT BE WET AND WASHED.
• The appliance is supplied with a Carbon Dust Filter#and 3 cartridges.
• The Carbon Dust Filter#and one of cartridge are located inside the Rear Grill. See Figure 1
for instructions on how to remove them from the unit for cleaning and maintenance.
• Do not run the unit in Cool & Humidity mode with stale water in the tank. You must empty
the water tank and refill it with fresh water, especially if the tank has not been cleaned in
a long time.
• The cleaning frequency for the Honeycomb & humidifier media depends on local air and
water conditions. In areas where the mineral content of water is high, mineral deposits
may build up on the Honeycomb Cooling Media & humidifer filter and restrict the
performance. Draining the water tank and refilling it with fresh water at least once a week
will help reduce mineral deposits. If mineral deposits remain on the Honeycomb Cooling
Media & humidifer filter, the media should be removed and washed under fresh water. The
media should be cleaned every two months or sooner, depending on your needs.
• For best results allow the Honeycomb Cooling Media & humidifer filter to dry after each
use by turning off the cool function 15 minutes before turning the unit off.
Table of contents