RACOM M!DGE2 User manual

User manual
.
M!DGE2
GPRS/UMTS/HSPA+/LTE
router
.
fw 4.2.x.x
6/11/2019
version 1.2
www.racom.eu
RACOM s.r.o. | Mirova 1283 | 592 31 Nove Mesto na Morave | Czech Republic
Tel.: +420 722 937 522 | E -mail: [email protected]


Table of Contents
Important Notice .................................................................................................................................. 5
Getting started ..................................................................................................................................... 6
1. M!DGE router .................................................................................................................................. 7
1.1. Introduction ........................................................................................................................... 7
1.2. Key features ......................................................................................................................... 7
1.3. Standards ............................................................................................................................. 8
2. M!DGE in detail ............................................................................................................................... 9
3. Implementation notes .................................................................................................................... 11
3.1. Ethernet SCADA protocols ................................................................................................. 11
3.2. Serial SCADA protocols ..................................................................................................... 11
3.3. Network center ................................................................................................................... 11
3.4. VPN tunnels ....................................................................................................................... 11
4. Product .......................................................................................................................................... 12
4.1. Dimensions ......................................................................................................................... 12
4.2. Connectors ......................................................................................................................... 12
4.3. Indication LEDs .................................................................................................................. 18
4.4. Technical specifications ...................................................................................................... 19
4.5. Model offerings ................................................................................................................... 22
4.6. Model offerings ................................................................................................................... 24
4.7. Accessories ........................................................................................................................ 25
5. Bench test / Step-by-Step guide ................................................................................................... 26
5.1. Connecting the hardware ................................................................................................... 26
5.2. Powering up your wireless router ....................................................................................... 26
5.3. Connecting M!DGE to a programming PC ......................................................................... 26
5.4. Basic setup ......................................................................................................................... 27
6. Installation ..................................................................................................................................... 28
6.1. Mounting ............................................................................................................................. 28
6.2. Antenna mounting .............................................................................................................. 28
6.3. Power supply ...................................................................................................................... 28
7. Web Configuration ......................................................................................................................... 29
7.1. HOME ................................................................................................................................. 29
7.2. INTERFACES ..................................................................................................................... 30
7.3. ROUTING ........................................................................................................................... 71
7.4. FIREWALL .......................................................................................................................... 85
7.5. VPN .................................................................................................................................... 90
7.6. SERVICES ....................................................................................................................... 102
7.7. SYSTEM ........................................................................................................................... 137
7.8. LOGOUT .......................................................................................................................... 159
8. Command Line Interface ............................................................................................................. 160
8.1. General usage .................................................................................................................. 161
8.2. Print help .......................................................................................................................... 162
8.3. Getting config parameters ................................................................................................ 162
8.4. Setting config parameters ................................................................................................ 163
8.5. Updating system facilities ................................................................................................. 163
8.6. Manage keys and certificates ........................................................................................... 163
8.7. Getting status information ................................................................................................ 164
8.8. Scan ................................................................................................................................. 165
8.9. Sending e-mail or SMS .................................................................................................... 166
8.10. Restarting services ......................................................................................................... 166
8.11. Debug ............................................................................................................................. 167
8.12. Resetting system ............................................................................................................ 167
3© RACOM s.r.o. – M!DGE2 GPRS/UMTS/HSPA+/LTE router

8.13. Rebooting system ........................................................................................................... 168
8.14. Running shell commands ............................................................................................... 168
8.15. CLI commands history .................................................................................................... 168
8.16. CLI–PHP ........................................................................................................................ 168
9. Troubleshooting ........................................................................................................................... 174
9.1. Common errors ................................................................................................................ 174
9.2. Messages ......................................................................................................................... 174
9.3. Troubleshooting tools ....................................................................................................... 174
10. Safety, environment, licensing ................................................................................................... 176
10.1. Safety instructions .......................................................................................................... 176
10.2. RoHS and WEEE compliance ........................................................................................ 177
10.3. EU Declaration of Conformity ......................................................................................... 178
10.4. Country of Origin ............................................................................................................ 182
10.5. Warranty ......................................................................................................................... 183
A. Glossary ...................................................................................................................................... 184
Index ................................................................................................................................................ 186
B. Revision History .......................................................................................................................... 189
List of Figures
1. Cellular router M!DGE ..................................................................................................................... 6
2.1. M!DGE front and terminal panel ................................................................................................... 9
4.1. Dimensions in millimeters ........................................................................................................... 12
4.2. Antenna connectors SMA ........................................................................................................... 12
4.3. 4× Eth RJ45 Plug ....................................................................................................................... 13
4.4. MicroSIM cards slots .................................................................................................................. 15
4.5. Screw terminal ............................................................................................................................ 15
4.6. Reset button ............................................................................................................................... 17
4.7. Indication LEDs .......................................................................................................................... 18
4.8. Flat bracket ................................................................................................................................. 25
4.9. Flat bracket dimensions ............................................................................................................. 25
10.1. EU Declaration of Conformity ................................................................................................. 178
10.2. EU Declaration of Conformity ................................................................................................. 181
10.3. Country of Origin declaration ................................................................................................. 182
List of Tables
4.1. Pin assignment Ethernet interface ............................................................................................. 13
4.2. Ethernet Port Specification ......................................................................................................... 13
4.3. USB 2.0 Host Port Specification ................................................................................................ 13
4.4. USB pin description .................................................................................................................... 14
4.5. Screw terminal pin assignment .................................................................................................. 16
4.6. Digital input levels ...................................................................................................................... 16
4.7. Digital output parameters ........................................................................................................... 16
4.8. Voltage Polarity connector misconnection Risks ........................................................................ 16
4.9. M!DGE interfaces and status indicators ..................................................................................... 18
4.10. Technical specifications ............................................................................................................ 19
4.11. Pin Assignments of COM/IO module ........................................................................................ 24
M!DGE2 GPRS/UMTS/HSPA+/LTE router – © RACOM s.r.o.4
M!DGE2
GPRS/UMTS/HSPA+/LTE router

Important Notice
Copyright
© 2019 RACOM. All rights reserved.
Products offered may contain software proprietary to RACOM s. r. o. (further referred to under the ab-
breviated name RACOM). The offer of supply of these products and services does not include or imply
any transfer of ownership. No part of the documentation or information supplied may be divulged to
any third party without the express written consent of RACOM.
Disclaimer
Although every precaution has been taken in preparing this information, RACOM assumes no liability
for errors and omissions, or any damages resulting from the use of this information. This document or
the equipment may be modified without notice, in the interests of improving the product.
Trademark
All trademarks and product names are the property of their respective owners.
Important Notice
• Due to the nature of wireless communications, transmission and reception of data can never be
guaranteed. Data may be delayed, corrupted (i.e. have errors), or be totally lost. Significant delays
or losses of data are rare when wireless devices such as the M!DGE are used in an appropriate
manner within a well‐constructed network. M!DGE should not be used in situations where failure to
transmit or receive data could result in damage of any kind to the user or any other party, including
but not limited to personal injury, death, or loss of property. RACOM accepts no liability for damages
of any kind resulting from delays or errors in data transmitted or received using M!DGE, or for the
failure of M!DGE to transmit or receive such data.
• Under no circumstances is RACOM or any other company or person responsible for incidental, acci-
dental or related damage arising as a result of the use of this product. RACOM does not provide the
user with any form of guarantee containing assurance of the suitability and fit for purpose.
• RACOM products are not developed, designed or tested for use in applications which may directly
affect health and/or life functions of humans or animals, nor to be a component of similarly important
systems, and RACOM does not provide any guarantee when company products are used in such
applications.
5© RACOM s.r.o. – M!DGE2 GPRS/UMTS/HSPA+/LTE router
Important Notice

Getting started
M!DGE Wireless Router will only operate reliably over the cellular network if there is a strong signal.
For many applications a flexible stub antenna would be suitable but in some circumstances it may be
necessary to use a remote antenna with an extension cable to allow the antenna itself to be positioned
so as to provide the best possible signal reception.
1. Install the SIM card
Insert a SIM card into the SIM socket. Make sure the SIM is enabled for data transmission.
2. Connect and fit the cellular antenna
If needed, contact RACOM for suitable antennas and other details.
3. Connect the LAN cable
Connect one M!DGE Ethernet port to your computer using an Ethernet cat.5 cable.
4. Connect the power supply
Connect the power supply wires to the M!DGE screw terminals, ensuring correct polarity. Switch
on the power supply.
5. Setting of IP address of the connected computer
By default the DHCP server is enabled, thus you can allow the Dynamic Host Configuration Protocol
(DHCP) on your computer to lease an IP address from the M!DGE. Wait approximately 20 seconds
until your computer has received the parameters (IP address, subnet mask, default gateway, DNS
server).
As an alternative you can configure a static IP address on your PC (e.g. 192.168.1.2/24) so that it
is operating in the same subnet as the M!DGE. The M!DGE default IP address for the first Ethernet
interface is 192.168.1.1, the subnet mask is 255.255.255.0.
6. Start setting up using a web browser
Open a web browser such as Internet Explorer or Firefox. In the address field of the web browser,
enter default IP address of M!DGE (i.e. http://192.168.1.1); initial screen will appear. Follow the in-
structions and use the M!DGE Web Manager to configure the device.
Fig. 1: Cellular router M!DGE
Note
M!DGE can be safely turned off by unplugging the power supply.
M!DGE2 GPRS/UMTS/HSPA+/LTE router – © RACOM s.r.o.6
Getting started

1. M!DGE router
1.1. Introduction
Although M!DGE wireless routers have been specifically designed for SCADA and telemetry, they are
well suited to a variety of wireless applications. M!DGE HW and SW are ready to maintain reliable and
secure connections from a virtually unlimited number of remote locations to a central server. Both
standard Ethernet/IP and serial interfaces are available. Moreover, a digital input and a digital output
can be used for direct monitoring and control of application devices; the second DI and DO are available
using an extension module.
M!DGE versatility is further enhanced by four independent Ethernet ports. These can be configured to
either support independent LANs (e.g. LAN and WAN settings), or simply connect up to four devices
within one LAN (effectively replacing an Eth switch). M!DGE software is based on proven components,
including an Embedded Linux operating system and standard TCP/IP communication protocols.
Thanks to the compact size and versatility of M!DGE, wireless routers prove indispensable in many
SCADA and telemetry, as well as POS, ATM, lottery and security/surveillance applications.
M!DGE together with RACOM RipEX radio router offers an unrivalled solution for combining cellular
and UHF/VHF licensed radios in a single network.
1.2. Key features
Mobile Interface Parameters
• Mobile Connection options: LTE, HSPA+, HSDPA, HSUPA, UMTS, EDGE, GPRS and GSM
• Global connectivity
• Transparent hand-over between 2G, 3G and 4G
Power supply
• Input voltage: 12 – 24 VDC
• Average power consumption: 7 W
Services / Networking
• Fallback Management
• Connection supervision, Automatic connection recovery
• Quality of Service (QoS)
• OpenVPN, IPsec, PPTP, GRE, Dial-In, Mobile IP
• VRRP
• OSPF, BGP
• DHCP server, DNS proxy server, DNS update agent, NTP
• Telnet server, SSH server, Web server
• Device server, Protocol server, SDK, LXC containers
• Port Forwarding (NAPT), Firewall, Access Control Lists
• Modbus TCP - Modbus RTU conversion
7© RACOM s.r.o. – M!DGE2 GPRS/UMTS/HSPA+/LTE router
M!DGE router

Interfaces
• 4 Ethernet ports: LAN, WAN/LAN
• RS232
• 1× DI, 1× DO
• USB host
Diagnostic and Management
• Web interface, CLI available
• File configuration
• OTA SW update
• Advanced troubleshooting
• SMS remote control, SMS and E-mail notification
• SNMPv1/v2c/3
1.3. Standards
EN 62368-1:2014Safety / Health
EN 62311:2008
EN 55032:2015EMC
EN 55035:2017
EN 61000-6-2:2016
EN 61000-6-3:2007+A1:2011+AC:2012
EN 301 489-1 V2.1.1
EN 301 489-3 V2.1.1
EN 301 489-7 V1.3.1
EN 301 489-17 V3.2.0
EN 301 489-24 V1.5.1
EN 301 489-52 V1.1.1
EN 300 328 V2.1.1RF Spectrum
EN 301 511 V9.0.2
EN 301 908-1 V11.1.1
EN 301 908-2 V11.1.1
EN 301 908-13 V11.1.1
M!DGE2 GPRS/UMTS/HSPA+/LTE router – © RACOM s.r.o.8
M!DGE router

2. M!DGE in detail
Fig. 2.1: M!DGE front and terminal panel
All M!DGE Wireless Routers run M!DGE Software. Software offers the following key features:
•Interfaces and Connection Management (Section 7.2, “INTERFACES”)
○ Dial-out (permanent, on switchover, distributed)
○ Link Supervision
○ Fallback to backup profile
○ SIM and PIN management
○ Automatic or manual network selection
○ Ethernet (LAN, WAN, bridging, IP passthrough, VLAN management)
○ Bridges
○ USB (autorun, device server)
○ Serial port (login console, device server, protocol server, SDK, Modem bridge, Modem emulator)
○ Digital I/O
•Routing (Section 7.3, “ROUTING”)
○ Static Routing
○ Extended Routing
○ Multipath Routes
○ Multicast
○ BGP
○ OSPF
○ Mobile IP
○ Quality of Service (QoS)
•Security / Firewall (Section 7.4, “FIREWALL”)
○ NAPT / Port Forwarding
○ Stateful Inspection Firewall
○ Firewall
•Virtual Private Networking (VPN) (Section 7.5, “VPN”)
○ OpenVPN Server/Client
○ IPsec Peer
○ PPTP Server/Client
○ GRE Peer
•Services (Section 7.6, “SERVICES” )
9© RACOM s.r.o. – M!DGE2 GPRS/UMTS/HSPA+/LTE router
M!DGE in detail

○ SDK
○ NTP Server
○ DHCP Server
○ DNS Server
○ Dynamic DNS Client
○ E-mail Client
○ Notification via E-mail and SMS
○ SMS Client
○ SSH/Telnet Server
○ SNMP Agent
○ Web Server
○ Redundancy
○ Modbus TCP
○ Discovery
○ Terminal server
○ LXC containers
•System Administration (Section 7.7, “SYSTEM”)
○ Configuration via Web Manager
○ Configuration via Command Line Interface (CLI) accessible via Secure Shell (SSH) and telnet
○ Batch configuration with text files
○ User administration
○ Troubleshooting tools
○ Over the air software update
○ Licensing (extra features)
○ Keys and certificates (HTTPS, SSH, OpenVPN, ...)
○ Legal Notice
M!DGE2 GPRS/UMTS/HSPA+/LTE router – © RACOM s.r.o.10
M!DGE in detail

3. Implementation notes
3.1. Ethernet SCADA protocols
SCADA equipment with an Ethernet protocol behaves as standard Ethernet equipment from a commu-
nications perspective. Thus the communication goes transparently through the cellular network. The
implementation requires heightened caution to IP addressing and routing. NAPT functionality should
be used frequently.
3.2. Serial SCADA protocols
A SCADA serial protocol typically uses simple 8 or 16 bit addressing. The mobile network address
scheme is an IP network, where range is defined by the service provider (sometimes including individual
addresses, even in the case of a private APN). Consequently, a mechanism of translation between
SCADA and the IP addresses is required. To make matters worse, IP addresses may be assigned to
GPRS (EDGE, UMTS, etc.) devices dynamically upon each connection.
Please read application note "M!DGE/MG102i - Serial SCADA Protocols"1which describes how to ef-
ficiently solve this problem using RACOM routers.
3.3. Network center
In every network, the center plays a key role and has to be designed according to customer's require-
ments. Several possible solutions are described in the application note "M!DGE/MG102i - Typical us-
age"2.
3.4. VPN tunnels
Customer data security arriving through the mobile network is often very important. Private APN is the
basic security requirement, but not safe enough for such applications.
VPN tunnels solution is closely connected with the center and is also described in application note
"M!DGE/MG102i - VPN Configuration"3.
1http://www.racom.eu/eng/products/m/midge/app/scada.html
2http://www.racom.eu/eng/products/m/midge/app/midge-mg102i_centre.html
3http://www.racom.eu/eng/products/m/midge/app/VPN_config.html
11© RACOM s.r.o. – M!DGE2 GPRS/UMTS/HSPA+/LTE router
Implementation notes

4. Product
4.1. Dimensions
Fig. 4.1: Dimensions in millimeters
4.2. Connectors
4.2.1. Antenna SMA
Fig. 4.2: Antenna connectors SMA
The M!DGE router is equipped with two antenna connectors. The ANT connector serves as a main
antenna connection, the AUX connector is auxiliary and serves for better communication with BTS
(diversity).
M!DGE2 GPRS/UMTS/HSPA+/LTE router – © RACOM s.r.o.12
Product

4.2.2. 4× Eth RJ45
Fig. 4.3: 4× Eth RJ45 Plug
Tab. 4.1: Pin assignment Ethernet interface
ETH (Ethernet 10BaseT
and 100BaseT)
RJ-45 Socket
signalpin
TX+1
TX−2
RX+3
RX−6
Note
Pairs 4-5 and 7-8 have an internal 75 Ohm termination.
Tab. 4.2: Ethernet Port Specification
SpecificationFeature
10/100 MbpsSpeed
TX−Mode
Automatic MDI/MDI-XCrossover
4.2.3. USB
M!DGE uses USB 2.0, Host A interface. USB interface is wired as standard:
Tab. 4.3: USB 2.0 Host Port Specification
SpecificationFeature
Low, Full & Hi-SpeedSpeed
max. 500 mACurrent
3 mMax. cable length
mandatoryCable shield
Type AConnector type
13© RACOM s.r.o. – M!DGE2 GPRS/UMTS/HSPA+/LTE router
Product

Tab. 4.4: USB pin description
wiresignalUSB pin
red+5 V1
whiteData (−)2
greenData (+)3
blackGND4
M!DGE2 GPRS/UMTS/HSPA+/LTE router – © RACOM s.r.o.14
Product

4.2.4. MicroSIM cards
Fig. 4.4: MicroSIM cards slots
The M!DGE router is equipped with two MicroSIM (3FF) cards slots which are placed under a SIM card
cover. Use PH0 screw driver for its opening. If using only one SIM card, use holder one.
The SIM card holder has a locking mechanism - for opening pull the front part of the holder down and
then you can open it. After inserting of SIM card (cropped edge left, connectors down), close the
holder and lock it.
Important
Power off the rourter before inserting the SIM card.
4.2.5. Screw terminal
Screw terminal plug type Stelvio Kontek CPF5/15 or MRT3P/15V01 can be used.
Fig. 4.5: Screw terminal
Screw terminal plug types:
Phoenix Contact 1847204 (MC 1.5/10-STF-3.5) for 10 pins plug and
15© RACOM s.r.o. – M!DGE2 GPRS/UMTS/HSPA+/LTE router
Product

Phoenix Contact 1847181 (MC 1.5/ 8-STF-3.5) for 8 pins plug (or equivalent).
This EXT plug is delivered only for units equipped with internal extension module.
Tab. 4.5: Screw terminal pin assignment
signalpin descriptionpin
Power input plus: 12–24 VDC (−20% +20 %) = 9.6–28.8 VDC12-24 VDC +1
Power input minus – internally connected with casing12-24 VDC -2
RS-232 GND (non-isolated)RS232 GND3
RS-232 RxD (non-isolated)RS232 RxD4
RS-232 TxD (non-isolated)RS232 TxD5
Digital input - Negative signal input (isolated to GND)DI -6
Digital input - Positive signal input (isolated to GND)DI +7
Digital Output isolated, Relay contact normally openDO NO8
Digital Output isolated, Relay commonDO COM9
Digital Output isolated, Relay contact normally closedDO NC10
Tab. 4.6: Digital input levels
0 to 3 VDClogical level 0
9 to 32 VDClogical level 1
Note: Negative input voltage is not recognised.
Tab. 4.7: Digital output parameters
1 AMaximal continuous current
32 VDCMaximal switching voltage
32 WMaximal switching capacity
Tab. 4.8: Voltage Polarity connector misconnection Risks
Plug pos.Plug pos.Plug pos.Plug pos.pin descriptionpin
−−
Nde
+
OK
−VGND
1
OK
+
Nde
−−+V+ (12–48 V=)2
−+
Nde
+
OK
−VGND
3
Nde
+
Nde
−−+V+ (12–48 V=)4
−+
DP [1]
+
DP [1]
−RxD5
DP [1]
+
DP [1]
−−+TxD6
−+
Nde
+
Nde
−GND7
Nde [2]
+
Nde [2]
−−+DO1-18
−+
Nde
+
Nde
−DO1-29
Nde [3]
+
Nde [3]
−−+DO2-110
−+
Nde
+
Nde
−DO2-211
Nde [4]
+
OK [4]
−−+DI1−12
−+Nde+Nde−DI1+13
M!DGE2 GPRS/UMTS/HSPA+/LTE router – © RACOM s.r.o.16
Product

Plug pos.Plug pos.Plug pos.Plug pos.pin descriptionpin
Nde [4]
+
OK [4]
−−+DI2−14
−+DI2+15
Explanatory notes for the table:
OK - Normal operation
DP - Damage possible
Nde - No damage expected
[1] - If the applied voltage is > 15 V, damage is likely
[2] - If the relay is closed (normally open), the relay is damaged when current > 5 A
[3] - If the relay is closed (normally closed), the relay is damaged when current > 5 A
[4] - If the applied voltage is > 40 V, input circuit damage is likely
4.2.6. Reset button
Fig. 4.6: Reset button
The Reset button is placed close to the USB connector. Use a blunt tool
no more than 1 mm in diameter (e.g. a paper clip) to press the button.
The reset button has two functions:
• Reboot the system
○ Press at least 3 seconds to release a system reboot.
○ The reboot is indicated with the red blinking STAT LED.
• Factory reset
○ Press at least 10 seconds to release a factory reset.
○ The start of the factory reset is confirmed by all LEDs lighting up
GREEN for a second.
• Recovery procedure
○ Press at least 15 seconds to release a recovery procedure.
○ The start of the recovery procedure is confirmed by all LEDs lighting up RED for a second.
Note
files.
17© RACOM s.r.o. – M!DGE2 GPRS/UMTS/HSPA+/LTE router
Product

4.3. Indication LEDs
Fig. 4.7: Indication LEDs
The following table describes the default M!DGE status indicators.
Tab. 4.9: M!DGE interfaces and status indicators
FunctionStateDescription
Device busy device is in startup, software- or configuration updategreen blinking
STAT Device is readygreen on
Hotlink is disabledoff
WAN Hotlink connection is being establishedblinking
Hotlink connection is upon
ETH: enabled as LAN and link status is upgreen
LAN No ETH LAN-connection is upoff
VPN connection is upgreen on
VPN VPN connection is being establishedgreen blinking
VPN connection downoff
EXT LED indicates the state of the extension interfaces.
Hint: Cellular (WWAN) signal strength can be indicated (green =
excellent, orange = medium, red = weak).
on / off / blinkingEXT
Shows the overall system state. This could be derived from health
indicators such as:
- all services up and running
- overall throughput is normal
- CPU load is normal
- the supervisor
- User application (state set by user in SDK or LXC)
SYS
System operation state: normalgreen on
System operation state: warning or in a transitiongreen blinking
System operation state: emergency, watchdog, failurered on
M!DGE2 GPRS/UMTS/HSPA+/LTE router – © RACOM s.r.o.18
Product

4.4. Technical specifications
Tab. 4.10: Technical specifications
M!DGE2Cellular inter-
face
4G LTE
Band 20 (800 MHz), Band 5 (850 MHz), Band 8 (900 MHz), Band 3 (1800 MHz),
Band 1 (2100 MHz), Band 7 (2600 MHz)
Frequency
bands E
3G UMTS/HSDPA/HSUPA
Band 5 (850 MHz), Band 8 (900 MHz), Band 2 (1900 MHz), Band 1 (2100 MHz)
2G GSM/GPRS/EDGE
GSM 850 MHz, E-GSM 900 MHz, DCS 1800 MHz, PCS 1900 MHz
4G LTE
Band 28 (750 MHz), Band 5 (850 MHz), Band 8 (900 MHz), Band 3 (1800 MHz),
Band 1 (2100 MHz), Band 7 (2600 MHz)
Frequency
bands P
3G UMTS/HSDPA/HSUPA
Band 5 (850 MHz), Band 8 (900 MHz), Band 2 (1900 MHz), Band 1 (2100 MHz)
2G GSM/GPRS/EDGE
GSM 850 MHz, E-GSM 900 MHz, DCS 1800 MHz, PCS 1900 MHz
4G LTE
Band 17 (700 MHz), Band 5 (850 MHz), Band 4 (1700 MHz), Band 2 (1900 MHz),
Band 7 (2600 MHz)
Frequency
bands A
3G UMTS/HSDPA/HSUPA
Band 5 (850 MHz), Band 8 (900 MHz), Band 4 (AWS, i.e. 1700 MHz), Band 2 (1900
MHz), Band 1 (2100 MHz)
2G GSM/GPRS/EDGE
GSM 850 MHz, E-GSM 900 MHz, DCS 1800 MHz, PCS 1900 MHz
3G UMTS/HSDPA/HSUPA
Band 5 (850 MHz), Band 8 (900 MHz), Band 2 (1900 MHz), Band 1 (2100 MHz)
Frequency
bands U
2G GSM/GPRS/EDGE
GSM 850 MHz, E-GSM 900 MHz, DCS 1800 MHz, PCS 1900 MHz
4G LTE
3GPP Release 9
Long Term Evolution (LTE)
Evolved Uni. Terrestrial Radio Access (E-UTRA)
Frequency Division Duplex (FDD)
DL Multi-Input Multi-Output (MIMO) 2×2
Specification
3G UMTS/HSDPA/HSUPA
3GPP Release 8
Dual-Cell HS Packet Access (DC-HSPA+)
UMTS Terrestrial Radio Access (UTRA)
Frequency Division Duplex (FDD) DL Rx diversity
2G GSM/GPRS/EDGE
3GPP Release 8
Enhanced Data rate GSM Evolution (EDGE)
GSM EGPRS Radio Access (GERA)
Time Division Multiple Access (TDMA)
19© RACOM s.r.o. – M!DGE2 GPRS/UMTS/HSPA+/LTE router
Product

DL Advanced Rx Performance Phase 1
Mobile Interface
LTE
4G - LTE: B1(2100), B3(1800), B5(850), B7(2600), B8(900), B20(800), all bands
with diversity
3G - WCDMA, HSPA, HSPA+ : B1(2100), B2(1900), B5(850), B8(900), all bands
with diversity
2G - GPRS, EDGE, GSM : 850, 900, 1800, 1900
Data rates up to 150 Mbps downlink / 50 Mbps uplink
4× Ethernet 10/100 Base-T, Auto MDX, 4× RJ45, bridged or routedEthernet
1× 3-wire RS232 on 15-pin screw terminal blockSerial Interface
1 digital input
Digital I/O
0–3 VDC level 0
9–32 VDC level 1
1 digital output
Relay outputs
Limiting continuous current 1 A
Max. switching voltage 32 VDC
Max. switching capacity 32 W
Isolation 1500 Vp (transients)
GNSS (option)
Active antenna 3.3 VDC; SMA female
72-channel u-blox M8 engine GPS/QZSS L1 C/A, GLONASS L10F BeiDou B1I,
Galileo E1B/C SBAS L1 C/A: WAAS, EGNOS, MSAS, GAGAN
GNSS
Time pulse
(option)
TTL logic: 1 pulse/s; SMA female
USB service
interface
USB host interface supporting memory devices
USB type A connector USB2.0
2× micro SIM (3FF)SIM
50 ΩImpedance:
Antenna
Interface 2× SMA female supporting MIMOConnector:
9.6–28.8 VDC (12–24 VDC −20 % / +20 %)Input voltage:
Power Supply 7 W (including max. 2.5 W on USB port)Avg. power
consumption:
Environmental
Conditions
For indoor use only, IP40
Metal casing, DIN rail mounting kit included
−40 to +70 °C (−40 to +158 °F)Temperature range:
0 to 95 % (non condensing)Humidity:
> 220.000 hours (> 25 years)MTBF (Mean Time Between Failure)
IOvervoltage Category:
2Pollution Degree:
DIN rail mountingMounting
M!DGE2 GPRS/UMTS/HSPA+/LTE router – © RACOM s.r.o.20
Product
Table of contents
Other RACOM Network Router manuals