RAMFAN ECX-110 User manual

Instruction Manual
ATEX/IECEX
ECX-110 & ECX-240
POWER EXTENSION CABLE
SM-ECXCABLE Rev B

2
READ MANUAL BEFORE STARTING FOR THE
FIRST TIME!
Thank you for purchasing the ATEX / IECEX POWER EXTENSION CABLE manufactured in the USA by
Euramco Group, Inc.
For more than 30 years Euramco Group has been on the cutting edge of industrial, fire, and marine
ventilation products. Each of our blower/exhausters, smoke ejectors, PPV & LSV fans and accessories
represent the finest technologies available. Every product is constructed to demanding and exact
specifications for quality, performance, and reliability.
When human life depends on having a fan that can deliver clean, safe air, you have only one choice you
can trust RAMFAN.
Explore our website and online catalog at www.euramco.com and discover how RAMFAN can make a
difference in the field.
All product information in the publication is based on the most current information available at the time
of printing. Euramco Group, Inc. reserves the right to make changes at any time without notice.
SM-ECXCABLE Rev B

3
CONTENTS
General Description ........................................................................................................................... 4-6
Model Numbers ................................................................................................................................... 7
Maximum Cable Length ……………………………………………………………………………………………………………………….8
Installation Instructions & Care ....................................................................................................... 9-11
Cautions ........................................................................................................................................... 11
Warranty ............................................................................................................................................ 12
How to Maintain Cables ..................................................................................................................... 12
Declaration of Conformity .................................................................................................................. 13
Original Manufacturer’s Installation Instructions ……………………………………………………………….………....... 14
SM-ECXCABLE Rev B

4
General Description
ATEX / IECEx Power Extension Cables, models ECX-110 & ECX-240, are designed to temporarily extend
the reach between an AC power source and an electrical device, such as portable fans, area lighting, etc.,
for use in hazardous locations.
The power cables are built with three critical parts; Cable, Plug, and Couplers. Cables were selected
based on the need for extra heavy-duty applications. Plugs and couplers were selected based on the
most used European connectors for hazardous locations.
The ATEX/IECEx ECX-110 & ECX-240 power extension cables are sold to our distributors & end users as
fully assembled, compliant power extension cables. No post assembly is required.
The drawing below depicts the ATEX / IECEx Power cable application, used to extend the reach of a
portable ATEX fan with H07RN-F cable and with three of the most popular brands of A.T.X, CEAG, and
R.Stahl, connectors.
The ATEX/IECEx Power Extension Cables are available for 110VAC Model ECX-110 or 240VAC Model ECX-
240 power requirements.
SM-ECXCABLE Rev B

5

6
The Power Extension Cables have been certified to meet the ATEX Directive 2014/34/EU certification for
II 2 G Ex db eb IIC T6 Gb, II 2 D Ex tb IIIC T80°C Db
The Power Extension Cables described here are intended for use in Explosive Atmospheres in accordance
within the limitation of the ratings. It is the user's responsibility to determine the suitability of the
equipment for the intended purpose.
Hazardous Location Rating
Category, Group & Zone classification
II 2 G Ex db eb IIC T6 Gb
II 2 D Ex tb IIIC T80°C Db
Zone 1, 2, 21, & 22
0539 Demko 20 ATEX 2364X
IECEx UL 20.0034X
Special Conditions for Safe Use
The letter “X” at the end of the ATEX & IECEx certificate numbers indicates a special
condition for safe use, this special condition of safe use for the ATEX/IECEx power
extension cables states that the coupling socket devices must not be used in dust areas
where highly charged generating processes, machine friction and separation processes,
electron spraying (e.g. around electrostatic coating systems) and pneumatically conveyed
dust occurs. The flameproof joints are not intended to be repaired.
SM-ECXCABLE Rev B

7
Model: ECX-110 ATEX/IECEx Power Ext. Cable for
110-130VAC
15 meter or 30 meter
Model: ECX-240 ATEX/IECEx Power Ext. Cable for
200-250VAC
15 meter or 30 meter
Model Numbers
SM-ECXCABLE Rev B

8
SM-ECXCABLE Rev B

9
SM-ECXCABLE Rev B
Installation Instruction and Care
The ECX-110 & ECX-240 power extension cables are fully assembled and ready for use upon receipt. No post assembly
required.
1. Completely uncoil power extension cable as to be used between AC power source and electrical device.
2. Inspect cable and connectors for damage or wear that could render the cable unsafe for hazardous locations.
3. Route cable to avoid contact with heavy machinery that could possibly damage cable or possible be a trip hazard
for workers. Cables must be integrated into a system in a way to support accessibility for regular maintenance.
4. Connect plug end of the power extension cable to the AC power source.
5. Verify AC power source is providing an electrical ground connection.
6. Verify electrical device is turned OFF before attaching power extension cable.
7. Connect coupler end of cable to the electrical device.
The power extensions shall be installed, so far as is practicable, in positions that will prevent them being exposed to
mechanical damage, to corrosion or chemical influences (for example solvents), to the effects of heat and to the effects
of UV radiation.
These are the minimum allowed bend radii for the cables. 1.5mm²: ≥4in, 2.5mm² ≥5.5in, 4.0mm² ≥6.2in.
The bend radius of the cable should start at least 25mm from the end of the cable.
Note: For ATX connectors lift dust covers and insert plug into coupler until coupler dust cap latches snaps into position
on plug. To break connection between coupler and plug lift dust cap to pull connectors apart.
Note: For CEAG connectors lift dust cover, insert plug into coupler, and rotate clockwise, to lock plug into coupler and
to close power switch within the coupler. To break connection between coupler and plug lift dust cap and rotate plug
counterclockwise to pull connectors apart.
Note: For R. STAHL connectors insert plug into coupler and rotate outer ring clockwise to secure plug to coupler.
A.T.X. Connector Installation and Removal
A.T.X: Plug to Socket & Coupler Compatible Table
VOLTAGE PLUG WALL SOCKETS COUPLER
100 / 130V PRE316PY PRE316RY PRE316MY
PRE316FY
200 / 250V PRE316PB PRE316RB PRE316MB
PRE316FB
Plug
removal
Plug
insertion

10
CEAG Connector Installation and Removal
Euramco Safety has several optional anti-static/conductive airflow duct accessories designed explicitly for
use with our Hazardous Location Fans to support various end user applications as identified in the list
below.
CEAG Eaton Crouse-Hinds: Plug to Socket & Coupler Compatible Table
VOLTAGE PLUG
WALL SOCKETS
COUPLER
100 / 130V GHG 511 7304 R0001
GHG 511 4304 R0001
GHG 511 3304 R0001
GHG 511 4304 R0002
GHG 511 4304 R3001
GHG 511 4304 R3003
GHG 511 8304 R0001
200 / 250V GHG 511 7306 R0001
GHG 511 4409 R0001
GHG 511 3306 R0001
GHG 511 4409 R3001
GHG 511 4409 R3003
GHG 511 8409 R0001
R. STAHL Connector Installation and Removal
R. Stahl: Plug to Socket & Coupler Compatible Table
VOLTAGE
PLUG
WALL SOCKETS
COUPLER
100 / 130V
8570/12-304
8570/11-304
8572/14-304
200 / 250V
8570/12-306
8570/11-306
8572/14-306
SM-ECXCABLE Rev B

11
Disconnect power before disassembly or cleaning. Never immerse or directly spray cable and connectors
with liquids. Clean cables with commercially available biodegradable cleaning solutions. Do not use
solvents containing hydrocarbons (i.e. MEK, Acetone).
There are no user serviceable parts. Contact factory for replacement part applicability.
Do not change make or model number the power extension cables for any reason!
Cautions
The ATEX / IECEx Power Extension Cables are intended for use in Explosive Atmospheres in accordance
with ATEX Directive 2014/34/EU. It is the user's responsibility to determine the suitability of the power
extension cables for the intended purpose.
CAUTION! THESE POWER EXTENSION CABLES ARE NOT INTENDED FOR USE IN MINES SUSCEPTIBLE TO
FIREDAMP.
Do not operate if there is any physical damage to cord, plug or receptacle.
Fatal electrical shock may result if power extension cables are not grounded in compliance with electrical
code.
Keep away from children.
ATEX / IECEx Extension Cable Rating: II 2 G Ex db eb IIC T6 Gb, II 2 D Ex tb IIIC T80°C Db
Euramco Safety hereby declares that the equipment listed in this manual conforms to the relevant
Essential Health and Safety Requirements of the European Machinery Directive and standards listed
below.
Standards to which conformity is declared: See Declaration of Conformity (last page). The ATEX / IECEx
Power Extension Cables complies with International Standards EN 60079-0:2012+A11:2013, EN 60079-
1:2014, EN 60079-7:2015, & EN60079-31:2014.
Category, Group and Zone Classifications
According to ATEX Directive (2014/34/EU)
The power cables are built with three critical parts; Cable, Plug, and Couplers. The H07RN-F cables were
selected based on the need for extra heavy-duty applications. Plugs and couplers were selected based
on the most used European connectors for hazardous locations.
The Power Extension Cables have been certified to meet the ATEX Directive 2014/34/EU certification for
II 2 G Ex db eb IIC T6 Gb, II 2 D Ex tb IIIC T80°C Db
Accessories
None
SM-ECXCABLE Rev B

12
Warranty
The ATEX / IECEx Power Extension Cables are warranted for one-year form date of original purchase, to
be free of defects in material and workmanship. Misuse and normal tear and wear are not covered under
the warranty.
RAMFAN products are warranted against manufacture defect. Failure to properly maintain power
extension cables will invalidate warranty coverage. Please visit www.euramco.com for warranty details.
How to Maintain Cable
How to maintain cable Maintenance
•Consult the relevant national regulations to determine the type and extent of inspections.
•Adapt inspection intervals to the operating conditions.
At a minimum, check the following points during maintenance work on their device:
•Firm fit of the conductors.
•Damage on the enclosure; seals or surface.
•Dirt on the sleeves.
•Compliance with the permissible temperatures (according to IEC/EN 60079).
•Whether the device is used in accordance with its intended use.
Cleaning
•To avoid electrostatic charging, the devices located in potentially explosive areas may only be
cleaned using a damp cloth.
•When cleaning with a damp cloth, use water or mild, non-abrasive, non-scratching cleaning agents.
•Do not use aggressive detergents or solvents.
•Prevent water and cleaning agents from penetrating the socket contacts.
Disposal
•Observe national and local regulations and statutory regulation regarding disposal.
•Separate materials when sending it for recycling.
•Ensure environmentally friendly disposal of all components according to the statutory regulations.
SM-ECXCABLE Rev B

13
Declaration of Conformity
SM-ECXCABLE Rev B

14
ORIGINAL MANUFACTURER’S
INSTALLATION INSTRUCTIONS
SM-ECXCABLE Rev B

SM-ECXCABLE Rev B
EURAMCO GROUP
This manual suits for next models
1
Table of contents
Other RAMFAN Cables And Connectors manuals
Popular Cables And Connectors manuals by other brands

Honeywell
Honeywell GSMX-AUDIO Cable Routing Instructions

Stahl
Stahl Ex Plug Connector miniClix operating instructions

Cisco
Cisco EIA/TIA-232 Serial Cable CAB-232FC Specification sheet

HUBER+SUHNER
HUBER+SUHNER 11 N-50-12-10 Assembly instructions

Condux
Condux 8 User's guide & safety manual

Staubli
Staubli PV-AZS4 Assembly instructions