Range Master PPMU User manual

PR O F E S S I O NA L SH O O T I N G GR O U N D AU T O M A T I O N
Order code: PPMU
Revision Date: 02.03.2021
File name: PPMU_ENG. df
Multi-Use Phono Pull
User Manual

Phono Pull Unit – Multi Use
Order code: PPMU
TABLE OF CONTENTS:
1.1 APPLICATION 2
1.2 FEATURES 2
1.3 TECHNICAL DATA 2
1.4 SHIPMENT CONTENTS 2
1.5 OPTIONS/ACCESSORIES 2
2.0 LEGEND 3
3.0 INSTALLATION 4
4.0 OPERATING 4
4.1 RECOMMENDATIONS/WARNINGS 5
5.0 LIMITED WARRANTY 6
6.0 RMA FORM
Copyright Maxima WarenhandelsGmbH © Rangemaster Systems - all material published on this manual is
protected by copyright including design of circuits and software.
You are expressly prohibited from electronically storing any material found here or republishing it by any means.
Furthermore it is prohibited to reverse-engineer software or hardware, disassemble or copy software or hardware
or parts of it.
This unit has been carefully produced for / by:
Maxima WarenhandelsGmbH
© Rangemaster Systems
Dr. Robert Graf Straße 64/9
Graz, A-8010
Austria/Europe
Phone: +43 699 104 03 204
Fax: +43 20 920 195
Mail: [email protected]
Web: www.rangemaster.at
RANGEMASTER SYSTEMS-Maxima arenhandelsGmbH
eb: www.rangemaster.at
Phone:+43 699 10403204
Rev.date:02/03/21 Page: 1
8010 Graz, Dr. Robert Graf Straße 64/9, Austria/Europe Mail: info@rangemaster.at Fax:+43 720 920 195 Doc name: PPMU_ENG.doc

Phono Pull Unit – Multi Use
Order code: PPMU
1.1 APPLICATION:
Wobble Trap, ATA and other types of clay target shooting
1.2 FEATURES:
•Instant release voice recognition/Phono pull unit
• Highly robust against noises to avoid no-birds
• Adjustable microphone sensitivity
• Adjustable timer: 0, 0,1 random 0 to 3 seconds in 0,3s steps
• 5 microphones directly connectible
• All microphones open with adjustable time between two calls
•LCD display with back light
• 12VDC external power supply with 220-240VAC input or car battery
• Simple installation
• High quality design
• Counter built-in
• Easy connection to payment systems
1.3 TECHNICAL DATA:
Power Input: With external power supply: 220-240VAC or any other 12-15V/1A DC power source
like car battery etc.
Power consumption: < 5W
Op. Temperature: - 20°C up to +50°C
Dimensions: Height: ,5cm, width: 20cm, depth: 29cm
Weight: 0, 5 kg
Output: +12V with ground switched or switched contact (relay)
Display: LCD, 2x16 digits/letters with back light
Counter: 1 Total counter, non resettable, 32bit
1 Counter, resettable, 32bit
1.4 SHIPMENT CONTAINS:
Phono Pull Unit
5 Microphone connectors
220-240VAC external power supply with connector
Additional connector for alternate external power supply
Plug to connect a trap
Manual
1.5 OPTIONS/ACCESSORIES:
Microphones: 26 Ohm highly sensitive microphone MIC00
Tripods/Pedestals: Colour-coated heavy duty tripod MIC03
RANGEMASTER SYSTEMS-Maxima arenhandelsGmbH
eb: www.rangemaster.at
Phone:+43 699 10403204
Rev.date:02/03/21 Page: 2
8010 Graz, Dr. Robert Graf Straße 64/9, Austria/Europe Mail: info@rangemaster.at Fax:+43 720 920 195 Doc name: PPMU_ENG.doc

Phono Pull Unit – Multi Use
Order code: PPMU
Payment: Secure chip cards CCSEC
Chip card loader, handheld CCC-2
Chip card loading software and chip card reader CCS
2.0 LEGEND:
LEGEND
FRONT:
F1: 2x16 DIGITS LCD DISPLAY
F2: ON/OFF
F3: RELEASE TIMER ON/OFF/ADJUST
F4: BLOCK TIMER ADJUST
F5: SLEEP/CONTINUE
F6: MICROPHONE SENSITIVITY ADJUSTMENT
BACK:
B1: POWER IN
B2: RELEASE TO TRAP OR PAYMENT SYSTEM
B3: RESET COUNTER 1
B4: 5x MICROPHONE IN SOCKETS
RANGEMASTER SYSTEMS-Maxima arenhandelsGmbH
eb: www.rangemaster.at
Phone:+43 699 10403204
Rev.date:02/03/21 Page: 3
8010 Graz, Dr. Robert Graf Straße 64/9, Austria/Europe Mail: info@rangemaster.at Fax:+43 720 920 195 Doc name: PPMU_ENG.doc

Phono Pull Unit – Multi Use
Order code: PPMU
3.0 INSTALLATION:
Items
necessary:
Multi-Use Phono Pull unit (PPMU)
Power (220-240VAC) for external power supply (PS included)
5 Microphones MIC00 with pedestals/tripods MIC03 (not included)
Microphone cables of any type with 2 wires (approx 0,5mm² each)
and cable connecting PPMU to trap (not included)
1..5 microphone connectors (included)
Plug for connecting cable to trap (included)
Soldering iron & solder (not included)
Small screwdriver (not included)
Step1: Cut microphone cables and trap release cable to appropriate length
Please note: All microphone cables have to be of the same length and diameter of wires!
Step : Solder microphone cable with microphone connectors
Step3: Connect microphone cables with the microphones
Please note: Connecting less then 5 microphones will make the Phono pull “hyper-sensitive”
and “false positives” might occur due to ambient noise!
ALWAYS CONNECT ALL 5 MICROPHONES!
Also be aware, that minimum distance between adjacent microphones must be > 1,5m!
Step4: Connect trap release cable to trap:
Pin out on 4 ways plug:
Pin1: +12V, Pin2: Relays in, Pin3: Relays out, Pin4: Ground (-)
Check if you need power supplied with ground(minus) switched
or if you operate your trap in a push button style.
+12V and switched ground: Connect + to pin 1 on connector, then connect –
to pin 2 on connector, make a bridge between pin 4 and pin 3.
Operate in push button mode:
1 wire goes to pin 2, 1 wire goes to pin 3, pin1 & pin4 are not connected
Step5: Ensure that all 5 microphones are properly connected to the 5 corresponding connectors B5
Connect Power supply with PPMU and to external AC power
Using another power supply (e.g. car battery): ensure that voltage is above 1 V and
below 15V. As there is a recti;er inside PPMU, you do not have to care about polarity!
RANGEMASTER SYSTEMS-Maxima arenhandelsGmbH
eb: www.rangemaster.at
Phone:+43 699 10403204
Rev.date:02/03/21 Page: 4
8010 Graz, Dr. Robert Graf Straße 64/9, Austria/Europe Mail: info@rangemaster.at Fax:+43 720 920 195 Doc name: PPMU_ENG.doc

Phono Pull Unit – Multi Use
Order code: PPMU
4.0 OPERATING:
Switch on unit using “Push Button F2”
Press F5 button to abandon “Sleep mode”
If necessary, adjust release timer by pushing button F3 (settable: 0, 0,1 or random from 0 to 3 seconds).
The value you set will be stored in EEPROM and this value is kept until changed again.
If necessary, adjust break time between two calls by pushing button F4 (adjustable from 1 to 5 seconds)
Sleep-/Continue:
- when pressing button F5, system will go in sleep mode and will not react to commands.
- Pressing button F5 again will wake up system again.
Adjust microphone sensitivity F6:
- clock-wise: more sensitive
- counter-clockwise: less sensitive
Resetting counter: Press button B4, Counter T1 will be set to Zero; Counter T2 is not resettable.
4.1 RECOMMENDATIONS & WARNINGS:
PPMU includes sophisticated over voltage protection and protection against lightening.
Nonetheless, it is recommended to disconnect PPMU from all cables during thunderstorms/
possible risk of lightening.
RANGEMASTER SYSTEMS-Maxima arenhandelsGmbH
eb: www.rangemaster.at
Phone:+43 699 10403204
Rev.date:02/03/21 Page: 5
8010 Graz, Dr. Robert Graf Straße 64/9, Austria/Europe Mail: info@rangemaster.at Fax:+43 720 920 195 Doc name: PPMU_ENG.doc

Phono Pull Unit – Multi Use
Order code: PPMU
5.0 LIMITED WARRANTY:
Rangemaster Systems gives a limited warranty on this products against defects in material or workmanship for
time of 12 months.
This period starts upon receipt of the product.
Rangemaster System will not be liable for loss of data or loss of proQt or turnover due to a defect.
The warranty only includes repair or replacement of defect components, which failed during daily use. “Daily use”
has to be read as: Use in accordance to speciQcations and in intended use.
General information & warranty exclusions: Damages due to water, moisture, vandalism, lightening, surges over
power line or power supply, usage outside of speciQcations, dropping the product, excessive heat or cold (both for
operation and storage) damages because of dropping the product, unnecessary force, damages because of empty
or discharged batteries or accumulators are warranty exclusions and do not entitle you for a free of charge repair
or replacement.
In case of chip card readers with contacts are built in the product. Items or dirt inside the reader are warranty
exclusions.
In case of touch screens are built in the product: Damages due to improper use (using something else than your
Qnger) causing scratches or punctures on the screen or on the touch surface will not be covered with warranty.
Please ask for a RMA number by sending an email to supp[email protected]
Add invoice number, date of invoice and serial number of product.
Also add a detailed description of errors.
Return unit for repair to:
Maxima WarenhandelsGmbH
© Rangemaster Systems – Ext. Storage
8082 Weissenbach 9
Austria/Europe
Show your RMA number of the box. Send us a tracking link after returning the product to us.
RANGEMASTER SYSTEMS-Maxima arenhandelsGmbH
eb: www.rangemaster.at
Phone:+43 699 10403204
Rev.date:02/03/21 Page: 6
8010 Graz, Dr. Robert Graf Straße 64/9, Austria/Europe Mail: info@rangemaster.at Fax:+43 720 920 195 Doc name: PPMU_ENG.doc

Phono Pull Unit – Multi Use
Order code: PPMU
6.0 RMA FORM:
To:
Maxima WarenhandelsGmbH
© Rangemaster Systems – Ext. Storage
8082 Weissenbach 9
Austria/Europe
RMA:________________ Date:______/_______/____________
Date of purchase
Supplied by
Invoice number (Please
attach copy of invoice)
Product serial number
Description of error
Please return to:
Name
Club
Address 1
Address
Zip code
City/Town
Country
Phone
E-Mail
RANGEMASTER SYSTEMS-Maxima arenhandelsGmbH
eb: www.rangemaster.at
Phone:+43 699 10403204
Rev.date:02/03/21 Page: 7
8010 Graz, Dr. Robert Graf Straße 64/9, Austria/Europe Mail: info@rangemaster.at Fax:+43 720 920 195 Doc name: PPMU_ENG.doc
This manual suits for next models
1
Table of contents