The GP™Series is a versatile, two-piece temperature monitoring system
which combines a compact, value-priced monitor with an infrared sens-
ing head. The heart of the system is the 1/8 DIN GP monitor which
provides advanced infrared processing capabilities including peak and
valley hold, averaging, and a user-adjustable offset. The rugged GPR
sensor is available with standard- or close-focus optics and provides
target temperature readings with 1% accuracy.
Along with its large 4-digit LED display, the monitor provides a
user-defined 4-20mA or thermocouple output. Two adjustable set-
points/deadbands control 5V alarm outputs or optional 3A mechanical
relays. The GP monitor accepts universal 110-220 VAC power, and
provides a 24 VDC/50 mA excitation voltage for loop power to external
sensors. All monitor functions are configured via the front panel,
including °C/°F switching.
The GP monitor provides adjustable emissivity when used with the
GPR and GPM infrared sensors. This high performance, 8 to 14 micron
infrared sensor with detachable cable combines current loop driven
signals with 35:1 optics.
The GPM sensor is a miniature stainless steel sensing head with 2:1
or 10:1 optics. The GP monitor also works with other Raytek infrared
sensors, including the CI and MID.
Product Desciption
Highlights:
• Temperature range from -18 to 538°C (0 to 1000°F)
• Compact 1/8 DIN digital monitor with large 4-digit display
• Monitor and sensor functions configured on front panel
• Signal processing capabilities typically found on much larger systems
• Adjustable emissivity
• Universal 110-220 VAC power
• User-defined 4-20 mA or thermocouple output (J,K,E,N,R,S,T)
• Adjustable dual setpoints and deadband alarm outputs
• Choice of sensing head to match application requirements
• Standard- and close-focus optics available
• Accessories for cooling and air purging
• Field interchangeable sensing heads
Raytek GP
Noncontact Infrared Temperature Sensor
Spectral Response & Temperature Range:
Sensing Head Model: Spectral Response: Temperature Range:
GPR 8 to 14 microns -18 to 538°C (0 to 1000°F)
GPM 7.6 to 18 microns -18 to 538°C (0 to 1000°F)
System Accuracy (mA output) ±1% of measured value or ±1°C (2°F),
whichever is greater, @ 23°C ±5°C (73°F ±9°F)
System Repeatability ±0.5% of measured value or ±1°C (2°F) whichever is
greater
Response Time (95%):
GPR 700 mSec
GPM 1 Sec
Emissivity: 0.1 to 1.09 digitally adjustable increments of .01
Signal Processing: Peak/Valley Hold (up to 998 sec, 999=infinite hold
with external reset)
Variable averaging filter (up to 60 seconds)
T-ambient: fixed background ambient temperature
compensation
Outputs 4-digit, 7 segment LED display, °C/°F selectable
User configurable 4-20 mA current or thermocouple
output (J,K,E,N,R,S,T)
Two adjustable setpoints with deadbands controlling
+5 V alarm outputs or optional 3A mechanical relays
Power Supply 110/220 VAC, ±20%, 50-60 Hz
User configurable inputs for GPR, GPM, any 0-5 V
or 4-20 mA sensor, or thermocouple (J,K,E,N,R,S,T)
External Reset input to reset Peak/Valley hold
24 VDC/50 mA excitation voltage
Environmental Rating:
GP Monitor Front Panel IP 54 (IEC 529); NEMA-12
GPR Sensing Head IP 65 (IEC 529); NEMA-4*
GPM Sensing Head IP 65 (IEC 529); NEMA-4
* GPR rated with adapter and compression fitting
Ambient Temperature Range:
GP Monitor 0 to 50°C (32 to 120°F)
GPR Sensing Head: 0 to 65°C (32 to 150°F)
With optional water cooling 0 to 177°C (32 to 350°F)
GPM Sensing Head: 0 to 85°C (32 to 185°F)
With optional air cooling 0 to 200°C (32 to 392°F)
Storage Temperature -30 to 65°C (-22 to 150°F)
Relative Humidity 10 to 95%, non-condensing
GP Monitor Dimensions 1/8 DIN x 120 mm (1.75 x 3.63 x 4.75 in)
GP Monitor Weight 320 g (0.7 lbs)
Electrical Specifications
• Cooling housings for high ambient conditions
• Air purge fittings for sensing heads
• Adjustable mounting brackets and adapters
• External isolated solid state relays for alarm outputs (10 Amp AC)
• 3A mechanical output relays
Raytek GP Series
Accessories / Options
General Specifications
17 (.67)
28 (1.1)
M 12x1
Ø 14 (.55)
11 (.43)
preinstalled cable
standard cable length 1 m ( 3 ft.)
Ø 5 (0.2) mm (in)
Dimensions
Sensing Head—Optical Specifications
GPR Sensing Head
GPM Sensing Head
GPM Sensing Head
Optical Chart
GPR Sensing Head Optical Charts
(NOTE: nominal spot size based on 90% energy)
Measurement Specifications (Monitor w/ Sensing Head)
Raytek, the Raytek logo, and Thermalert are registered trademarks
of Raytek Corporation.
©2001 Raytek Corporation, Printed in USA, 3/01 Rev. A
Specifications subject to change without notice. 3-1003
Worldwide Headquarters
Raytek Corporation
Santa Cruz, CA USA
Tel: 1 831 458 1110
800 227 8074 (U.S. and Canada only)
Fax: 1 831 458 1239
www.raytek.com
5710 Kenosha Street
Richmond, Illinois 60071 USA
Phone: +1 (815) 678-2211
FAX: +1 (815) 678-3961
Internet: www.watlow.com
e-mail: info@watlow.com RIC-GP-0401
For Sales and Ordering Contact: For Service and
W arranty Contact:
Your Authorized W atlow Distributor Is:

Other manuals for GP Series

1

This manual suits for next models

3

Other RayTek Accessories manuals

RayTek TX User manual

RayTek

RayTek TX User manual

RayTek TX User manual

RayTek

RayTek TX User manual

RayTek CM User manual

RayTek

RayTek CM User manual

RayTek MID User manual

RayTek

RayTek MID User manual

RayTek RAYCMLTJM User manual

RayTek

RayTek RAYCMLTJM User manual

RayTek MI3 User manual

RayTek

RayTek MI3 User manual

RayTek CI Series User manual

RayTek

RayTek CI Series User manual

RayTek XR User manual

RayTek

RayTek XR User manual

RayTek MI3 User manual

RayTek

RayTek MI3 User manual

RayTek MI Miniature Infrared Sensor User manual

RayTek

RayTek MI Miniature Infrared Sensor User manual

RayTek 54301 User manual

RayTek

RayTek 54301 User manual

Popular Accessories manuals by other brands

Canofix T500161 installation manual

Canofix

Canofix T500161 installation manual

Carefree Compass installation manual

Carefree

Carefree Compass installation manual

Philips VCM4250/00 Instructions for use

Philips

Philips VCM4250/00 Instructions for use

Zte ZXG10-OB06 Technical manual

Zte

Zte ZXG10-OB06 Technical manual

Kistler 93 1C Series instruction manual

Kistler

Kistler 93 1C Series instruction manual

Dorner 2200 series Installation & parts manual

Dorner

Dorner 2200 series Installation & parts manual

Ednet 31901 user manual

Ednet

Ednet 31901 user manual

Baumer OADM 12U7430/S35A manual

Baumer

Baumer OADM 12U7430/S35A manual

KRACK Fluid Cooler Series Installation and operation manual

KRACK

KRACK Fluid Cooler Series Installation and operation manual

Kogan KAEXTEVACLA instructions

Kogan

Kogan KAEXTEVACLA instructions

Techmar 6156011 quick start guide

Techmar

Techmar 6156011 quick start guide

Politec SADRIN 615 manual

Politec

Politec SADRIN 615 manual

SBG Systems EKINOX 2 Series Hardware manual

SBG Systems

SBG Systems EKINOX 2 Series Hardware manual

SUTO S 430 Instruction and operation manual

SUTO

SUTO S 430 Instruction and operation manual

Lippert Components Solera 674282 Installation and owner's manual

Lippert Components

Lippert Components Solera 674282 Installation and owner's manual

fontastic Eris 6 user manual

fontastic

fontastic Eris 6 user manual

Philips CRP301 brochure

Philips

Philips CRP301 brochure

Central Machinery 93242 instruction manual

Central Machinery

Central Machinery 93242 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.