> GB_USER GUIDE
SPECIFICATIONS
* Sensor: Semiconductor
* Warm-up time: 10 seconds
* Respond time: 5 seconds
* Operating temperature range 5~40°C
* Detection range: 0.00~0.19% BAC and 0.0~1.9g/l
* Digital display results % BAC and g/l
* Powers off automatically
* Temperature indicator
* Low voltage indicator
* Alarm clock & countdown timer
* Tester needs 2 x AAA battery, (not included)
* Clock: Works on 1 x LG13 celle button battery, (included)
* Size (LxWxD): 100x37x17 mm
* Weight: 40 g
WARNING!
The only true reading of a person’s BAC (blood alcohol
concentration) is by administration of blood test. This device
is to be used as a reference only. Do not drive or operate
machinery if you had any alcoholic drink. Manufacturer
and retailer do not accept any legal responsibility.
REALTIME
1. In real time mode, press <ADJ> button
to select 12 or 24 hour format.
2. Press and hold <SET> button for 2 seconds to enter
real time hour setting, the hour digit is flashed on
the clock LCd, press <ADJ> button to adjust.
3. Press <SET> button again to enter minute setting,the
minute digit is flashed,press <ADJ> button to adjust.
4. Press <SET> button to confirm.
ALARM TIME
1. In real time mode, press <MODE> button
once to enter alarm model.
2. Press <ADJ> button for select alarm on or off.
3. Press and hold <SET> button for 2 seconds to enter
alarm time hour setting, the hour digit is flashed
on the clock LCd, press <ADJ> button to adjust.
4. Press <SET> button again to enter minute setting,the
minute digit is flashed,press <ADJ> button to adjust.
5. Press <SET> button to confirm.
TEMPERATURE
1. In real time mode, press <MODE> button
twice to enter temperature model.
2. Press <ADJ> button for select C or F format.
COUNTER DOWN TIMER
1. In real time mode, press <MODE> button
3 times to enter timer model.
2. Press and hold <SET> button for 2 seconds to
enter timer hour setting, the hour digit is flashed
on the clock LCd, press<ADJ>button to adjust.
3. Press <SET> button again to enter minute setting,the
minute digit is flashed,press <ADJ> button to adjust.
4. Press <SET> button to confirm.
5. Press <ADJ> button to start countdown,
when the timer value is not 00.00, press
<ADJ> button again to stop the timer.
6. When the timer countdown to 00.00, the alarm
will sound. then reload the timer value.
Alcohol breathalyser
> HB-603 / DIGITAL
> PLEASE READ THESE INSTRUCTIONS BEFORE USE
PRODUCT DISPOSAL
Used product should not be disposed as household waste. According to legislation, the product should
be disposed of properly so that the materials can be recycled in an environmentally friendly manner.
Further information is available from the responsible local authority or local disposal company.
1) Clock/Ur/Klokke LCD
2) Alcohol tester LCD
3) ON/OFF
4) Breath inhaler
5) MODE
6) SET
7) ADJ
8) Battery compartment
9) Reset