RDL D Series User manual

ACCESSORIES
Models D-RLC10M, DS-RLC10M, DB-RLC10M
Remote Level Control with Muting
Rotary Optical Encoder Remote Level Control
Single or Multiple Control Locations
Up To Ten Remote Control Locations
Integral 0 to 10 VDC Ramp Generator
Visual Level Display of Operating Level
Display is Bright During Adjustment
Display Dims After Adjustment
Powers Up to Last Level or Stored Preset Level
Compatible with All RDL VCA Modules
Available in Stainless Steel, Black and White
The D SERIES-RLC10M remote controls are part of the group of versatile accessory products from Radio Design Labs. These modules combine durable construction with high quality
components and attractive, professional graphics. The D SERIES-RLC10M controls mount in separately available electrical wall boxes and cover plates.
The D SERIES-RLC10M is a rotary remote level control with pushbutton muting that provides user adjustment at
single or multiple locations. Optical encoder technology allows continuous knob rotation with a comfortable
adjustment rate and long-term trouble-free and noise-free operation. These controls directly connect to any RDL
VCA and OEM equipment with 0 to 10 Vdc ramp inputs.
A single –RLC10M may be connected to a ramp-controlled VCA using a single-pair shielded audio cable or
unshielded cable. A rear-panel switch configures the control as the MASTER. The MASTER mode causes this
control to drive the 0 to 10 Vdc ramp output and to monitor its pulse terminals in case any other –RLC10M controls
are connected.
As many as nine additional –RLC10M controls may be wired in parallel with the MASTER control using UTP cable
(CAT5, CAT6 or equivalent). The rear-panel MODE switch on each additional remote control is set to SLAVE mode.
Operation is the same for a single control, or for each control connected in a multiple control point installation. The 0
to 10 Vdc ramp voltage is incremented up or down when the front-panel knob is rotated. Acceleration is provided so
the rate of change is faster when the knob is rotated more rapidly, yielding a responsive feel and rapid elimination of
acoustic feedback. The LED ring display encircling the control knob operates as a virtual pointer. When an –RLC10M
is not being adjusted, its display switches to a dim intensity to avoid being a visual distraction. The display returns to
a bright intensity during adjustment.
Upon power-up or re-powering after a power loss, the 0 to 10 Vdc ramp will output either a preset level or the last
level used. The power-up mode is stored when the control is installed. When programmed for the preset level
mode, the user can store a new preset level by holding the MUTE button for more than 3 seconds.
Multiple –RLC10M controls set to the SLAVE MODE may be connected to an RDL RU-VCA2A or RU-VCA6A,
utilizing the VCA as the ramp generator. This connection is also possible with OEM equipment accepting open-
collector pulses that are compatible with the –RLC10M output pulse rate and width.
The –RLC10M controls are constructed on a steel frame. The electronics are fully protected within the rear
enclosure. Connections are made through a rear panel detachable terminal block. The MUTE pushbutton is a long-
life switch mounted to provide protection from excessive frontal force.
All the D SERIES-RLC10M features combine to make it the ideal choice for single point or multiple location remote
level control with muting in high quality systems. Use them with any RDL VCA module, or side-by-side with other
RDL remote accessories as part of a complete audio/video system.
RDL 659 N. 6th St. Prescott, AZ., USA 86301 (928) 443-9391 FAX (928) 443-9392 www.rdlnet.com
DB-RLC10M DS-RLC10M D-RLC10M
ACCESSORIES
Models D-RLC10M, DS-RLC10M, DB-RLC10M
TYPICAL PERFORMANCE
Ramp: 0 to 10 Vdc (Slave mode input; Master mode output)
Pulse outputs (2): Open-Collector @ 20 mA (UP, DOWN)
Pulse duration: 500 uS (min.) to 4 mS (max.)
Pulse interval: 500 uS (min., between consecutive pulses)
Rotations, approximate min-to-max: 5 (slow rotation, no acceleration)
3 (medium rotation, with acceleration)
1 (fast rotation counterclockwise)
Level Control: Optical rotary encoder
Muting: Momentary pushbutton with LED indicator
Power Requirement: 24 Vdc @ 50 mA, Ground-referenced
Mounting: Mounts in standard US electrical box,
RDL WB- or SMB- series boxes;
cover plate available separately
Dimensions: Height: 4.11 in. 10.44 cm; Width: 1.31 in. 3.33 cm;
Depth: 0.98 in. 2.49 cm (w/o knob); Depth: 0.545 in. 3.93 cm (overall)
Installation/Operation
EN55103-1 E1-E5; EN55103-2 E1-E4
Typical Performance reflects product at publication time
exclusive of EMC data, if any, supplied with product.
Specifications are subject to change without notice.
Radio Design Labs Technical Support Centers
U.S.A. (800) 933-1780, (928) 778-3554; Fax: (928) 778-3506
Europe [NH Amsterdam] (++31) 20-6238 983; Fax: (++31) 20-6225-287
891-5610
NOTE: This equipment has been tested and
found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC
Rule. These limits are designed to provide
reasonable protection against harmful
interference in a residential installation. The
equipment generates, uses and can radiate
radio frequency energy and, if not installed and
used in accordance with the instructions, may
cause harmful interference to radio
communications. However, there is no
guarantee that interference will not occur in a
particular installation. If this equipment does
cause harmful interference to radio or television
reception, which can be determined by turning
the equipment off an on, the user is
encouraged to try to correct the interference by
one or more of the following measures:
Reorient or relocate the receiving
antenna
Increase the separation between the
equipment and receiver
Connect the equipment into an outlet
on a circuit different from that which the
receiver is connected.
Consult the dealer or an experienced
radio/TV technician for help.
SET-UP PROGRAMMING (applicable to MASTER controls only)
Set power-up mode (last level used or preset level) during installation:
1] Press and hold the MUTE button while applying power and continue to hold for 3 seconds. This toggles the control to the opposite
mode from its last operating mode. (If it had been in preset mode, it will now be in last level used mode.)
2] LEDs 1,2,9 & 10 will flash to indicate the selected operating mode: Single Flash: Last level used mode; Double Flash: Preset mode
3] If the control is in the desired mode, begin operation; If the control is in the incorrect mode, repeat Step 1.
Storing the level in preset mode
1] Adjust the level for the desired preset level.
2] Press and hold the MUTE button for more than 3 seconds. LEDS 1,2,9 & 10 will double flash to indicate the preset level is stored.

This manual suits for next models

3

Popular Controllers manuals by other brands

NANOTEC ELECTRONIC N5 Technical manual

NANOTEC ELECTRONIC

NANOTEC ELECTRONIC N5 Technical manual

Digitrax DZ123MK0 quick start guide

Digitrax

Digitrax DZ123MK0 quick start guide

DROPSA VIP5 Pro User Operating and Maintenance Manual

DROPSA

DROPSA VIP5 Pro User Operating and Maintenance Manual

Hubbell GAI-Tronics 013-02-0095-005 quick start guide

Hubbell

Hubbell GAI-Tronics 013-02-0095-005 quick start guide

ZKTeco C5S110 Installation and connection guide

ZKTeco

ZKTeco C5S110 Installation and connection guide

SYRUNS SY5000 series user manual

SYRUNS

SYRUNS SY5000 series user manual

Emerson Fisher MR95 Series instruction manual

Emerson

Emerson Fisher MR95 Series instruction manual

BlueField BF1600 Hardware installation

BlueField

BlueField BF1600 Hardware installation

Grainfather CONICAL FERMENTER PRO Instructions for installing

Grainfather

Grainfather CONICAL FERMENTER PRO Instructions for installing

Geco GH10NA user manual

Geco

Geco GH10NA user manual

Emerson Fisher 585C Series instruction manual

Emerson

Emerson Fisher 585C Series instruction manual

Semicool ERT-10-3-321C manual

Semicool

Semicool ERT-10-3-321C manual

SEW-Eurodrive SCM-B 2B 48-000-00 Series manual

SEW-Eurodrive

SEW-Eurodrive SCM-B 2B 48-000-00 Series manual

Cisco Catalyst 9800-80 installation guide

Cisco

Cisco Catalyst 9800-80 installation guide

JOVENTA MM1.1 quick start guide

JOVENTA

JOVENTA MM1.1 quick start guide

Biamp SPM 412e instructions

Biamp

Biamp SPM 412e instructions

esera automation 1-Wire Controller 1 user guide

esera automation

esera automation 1-Wire Controller 1 user guide

Micha Solar MSR2-30 product manual

Micha Solar

Micha Solar MSR2-30 product manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.