RDT FloodMaster RS-094-MK4 Manual

Leak Detection & Automatic Shut-Off System for
Conventional Plug-In Power-Vent Gas Water Heaters
with Electrical Plug Interrupter
Congratulations on your purchase of a FloodMaster RS-094-MK4 water heater leak detection system from
Reliance Detection Technologies. This product is designed to automatically shut off the water supply to a
water heater or tank if a leak is detected. This kit also provides output signal capabilities to automatically
kill electricity to the water heater power vent when a leak is detected.
To ensure proper installation and to maximize the performance of your RS-094-MK4 water leak detection
system, please read this manual thoroughly before installing or operating the system.
PLEASE READ CAREFULLY BEFORE PROCEEDING: If a leak is detected, the RS-094-MK4 will shut off the
water going to the water tank. This will stop the continuous ow of water from the water supply to the tank.
However, all or some of the water that is already in the tank may still leak out onto the oor.
NOTE: This installation and operating manual contains important information about the operation of the
RS-094-MK4 system. If this system is being installed for use by a different user, please be sure a copy of
this manual is left with the system for future reference.
www.RelianceDetection.com Toll-Free: 888-771-4929
RS-094-MK4 System Components (included in kit):
1 – Receiver box / actuator
1 – 3/4” full port lead-free shut-off valve
(NSF/ANSI 61 and 372)
1 – Power supply with 12’ lead wire
1 – Water sensor with 8’ lead wire
1 – Metal plate for sensor placement
1 – Electrical plug interrupter
RS-094-MK4
Warning: For use with water only. Do not install on gas line. Never install this device
on a re protection or re suppression system. For indoor use only.

NOTE: The RS-094-MK4 can be installed on existing or new water heater installations.
RDT recommends installation by appropriately licensed and certied installers to ensure that all local
code requirements are met.
INSTALLATION INSTRUCTIONS
1. Turn off the water supply feed line to the water heater. Conrm that the power-vent water heater is
unplugged from the electrical supply.
2.
Prior to installation, manually exercise the valve body to fully closed and back to fully open position
by holding it in your hand, applying a pliers to the valve stem and turning. Thread the valve body into
the feed water line after the manual shut-off. Apply pipe sealant or Teon
®
tape to the NPT threads
and tighten
.
3. The receiver connector comes prewired with basic connections to the power supply, sensor
and electrical plug interrupter. Using an appropriate screwdriver, make any additional electrical
connections as may be desired for output contacts or additional sensors per wiring Figure 2.
(Note: additional sensors can be connected to either 6 & 7 or 8 & 9, as wiring space allows.)
Then snap the terminal wiring block into the receiver housing at the mating slot provided.
4. Secure the valve body in one hand and snap the receiver into place on the valve body mounting
pad. (Note: Improper alignment of the valve stem may interfere with proper receiver mounting.
If any resistance is encountered, conrm the witness mark on the valve stem is in alignment with
the valve ports. Use an appropriate hand tool, such as pliers, to clamp down on the valve stem and
turn in the appropriate direction until the desired position is achieved).
5. Route and secure the 18-2 wire from the power-off relay to the location of the 120V AC wall outlet
that supplies the water heater power-vent unit.
6. Plug the power-off relay fully ush into a wall receptacle. Do not plug into an extension cord.
7. Plug the power-vent water heater cord into the power-off relay and activate the power-vent unit.
8. Place the sensor(s) where water is most likely to rst accumulate (such as the drain pan or the
oor next to the tank). The sensor is magnetic and can be installed horizontally or vertically in
conjunction with the metal plate – see Figure 3.
• Clean the desired location area to ensure the surface is clean for optimum plate adhesion.
• Peel the backing off the metal plate to reveal the adhesive and stick in place.
•
Place the sensor on the plate as close as possible to the oor, allowing the magnets to secure
it in place.
Note: The sensor features a through-hole that can be used to screw it onto a surface if a more
permanent installation is desired or necessary.
9. Plug the RS-094 power transformer into a wall outlet. The green “Power” indicator light on the
receiver will turn on. Open the water supply feed line.
10. Function Test the system as follows:
• Place the sensor on a wet paper towel. The audible alarm will sound and the valve will rotate to
the closed position. The power-off relay will also respond to kill power to the power-vent unit.
• The red “Valve Closed” LED will turn on when the valve is completely closed (approximately
45-second cycle time). Open a hot water faucet and conrm that there is no water ow. Conrm
deactivation of the power-vent water heater.
• Remove the sensor from the paper towel, dry the contact points, and place it back in the desired
location on the metal plate.
• Press and release the “Reset” button on the receiver to open the valve and begin the ow of
water again (approximately 45 seconds to fully re-open). The green “Power” indicator light will
ash once to indicate the reset process has begun. Conrm reactivation of the power-vent unit.
Open a hot water faucet and inspect for water ow.

4.95
2.24
RS-094-MK4
WATER
HEATER KIT
1. Receiver box
2. Valve Closed LED
3. Power LED
4. Wiring terminal block
5. Reset button
6. Valve actuator
7. Water sensor
8. Metal plate
9. Shut-off valve
10. Power transformer
11. Electrical plug interrupter
4
3 5
3.0
3.1
1.53.0
1.4
2.5
.4
1.4
1.11.350
4.9
1FRONT VIEW BACK VIEW
2
6
2.56
Ø .12 THRU
1.77
.02
1.48
1.69
8 FT LEAD
.30
.04
PIN OFFSET
FROM SURFACE
Ø .25 .30
Ø .38 x 82°
7
8
9
See RS-094 technical
data submittal sheet for
valve dimensions.
FIGURE 2 –
WIRING DIAGRAM
FIGURE 3 –
SENSOR INSTALLATION OPTIONS
HORIZONTAL VERTICAL
11
POWER SUPPLY
RS-094
1234567891 2
GREENGREENRED
FIGURE 1
KIT PREWIRED AT FACTORY
1.89
12 FT LEAD
10

All specications subject to change without notice.
© Copyright 2020 Reliance Detection Technologies, LLC – A Madison Company
ECN # 11386, 09/2020, MF105, RevB
OUTPUT SIGNAL CONNECTIONS
The unit also provides output signal capabilities (SPDT Relay Output Contact) for connection to a home
security panel or for use with an appropriate relay to control a secondary device, such as a pump. See
Figure 2 for wiring diagram.
Normally Closed Circuit – Terminal Pins 3 & 4 Normally Open Circuit – Terminal Pins 4 & 5
OPERATION & SYSTEM RESET
In the event the system activates, locate the source of the leak, remove the sensor from the water and
dry the metal contacts on the bottom. Correct the problem causing the leak and replace the sensor in
the desired leak detection location once again as required. Press and release the “Reset” button on the
receiver to open the valve and begin the ow of water again. The green “Power” indicator light on the
receiver will ash once to conrm the reset. Conrm reactivation of the power-vent unit.
MAINTENANCE
Test the system annually per the function test (install step 10) to ensure correct operation and maintain
product warranty status. At a minimum, exercise (press and release) the “Reset” button on the receiver.
EMERGENCY MANUAL VALVE OPERATION
The unit is equipped with an emergency feature for the manual rotation of the valve. Disengage the
actuator from the valve and manually changing the valve to open or closed as follows:
1. Turn off the main power to the transformer.
2. Stabilize the water feed line by grabbing it in one hand near the valve. While grasping the actuator
housing in the other hand, pull the actuator housing away from the water feed line.
3.
Using an appropriate hand tool (such as a pliers), clamp down on valve stem and turn in the appropriate
direction until the desired position is achieved. Note the top of the stem is slotted to indicate valve
position (in line with water ow indicates open valve; slot across water line indicates closed).
4. Before remounting the actuator, return the valve to the original position prior to the manual rotation.
5. Remount the actuator and restore the main power to the transformer.
6. Test for correct operation per the function test listed in install step 10.
203-488-2684 or 888-771-4929
27 Business Park Drive, Branford, CT 06405
www.RelianceDetection.com [email protected]
NEED INSTALLATION OR SETUP ASSISTANCE?
Call toll-free: 888-771-4929 or visit www.RelianceDetection.com/support/RS-094
For use in dry locations only. Always unplug the relay module before servicing or installation. For continued
protection against electric shock, plug into grounded outlets only and do not remove the ground pin.
DANGER – Risque d’électrocution
À utiliser dans des endroits secs uniquement. Toujours débrancher le module de relais avant l’entretien ou
l’installation. Pour une protection continue contre l’électrocution, uniquement brancher à des prises mises à la terre
et ne pas retirer la broche de terre.
DANGER – Electrocution Hazard
Table of contents
Popular Control System manuals by other brands

AxeMotion
AxeMotion PULSEBOX NxtG user guide

Techno-Isel
Techno-Isel DaVinci Setup

Teknic
Teknic EF-785 installation guide

DriSteem
DriSteem Vapor-logic 4 Installation and operation manual

Hobym Observatory
Hobym Observatory TiTaN TCS Opeation Manual

Johnson Controls
Johnson Controls SABROE Unisab III Control Engineering manual