manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. red lion
  6. •
  7. Measuring Instrument
  8. •
  9. red lion CUB5P User manual

red lion CUB5P User manual

Install CUB5P- A
Drawing No. LP1133
Effective 06/2022
Model CUB®5P - Miniature Electronic
5-Digit Process Meter
Installation Guide
1
See the Red Lion website at www.redlion.net for full user manual.
SAFETY SUMMARY
All safety related regulations, local codes as well as instructions
that appear in this document or on equipment must be observed
to ensure personal safety and to prevent damage to either the
device or equipment connected to it.
Do not use these products to replace proper safety interlocking.
No software-based device (or any other solid-state device) should
ever be designed to be responsible for the maintenance of
personnel safety or consequential equipment not equipped with
safeguards. Red Lion disclaims any responsibility for damages,
either direct or consequential, that result from the use of this
equipment in a manner not consistent with these specifications.
ORDERING INFORMATION
DESCRIPTION PART NUMBER
Process Meter with Reflective Display CUB5PR00
Process Meter with Backlight Display CUB5PB00
SPECIFICATIONS
1. POWER: Input voltage range is +9 to +28 VDC with short
circuit and input polarity protection. Must use an RLC model
MLPS or an NEC Class 2 or Limited Power Source (LPS) rated
power supply.
MODEL NO. DISPLAY COLOR
INPUT CURRENT
@ 9 VDC
WITHOUT
CUB5RLY0
INPUT
CURRENT @
9 VDC WITH
CUB5RLY0
CUB5PR00 --- 10 mA 40 mA
CUB5PB00 Red (max intensity) 85 mA 115 mA
CUB5PB00 Green (max intensity) 95 mA 125 mA
2. DISPLAY: 5 digit LCD 0.48" (12.2 mm) high digits
CUB5PR00: Reflective LCD with full viewing angle
CUB5PB00: Transmissive LCD with selectable red or green
LED backlight, viewing angle optimized. Display color change
capability with output state when using an output module.
3. INPUT RANGES: Jumper Selectable
0 to 10 V, 0(4) to 20 mA, 0 to 50 mA
4. ENVIRONMENTAL CONDITIONS:
Operating Temperature Range for CUB5PR00: -35 to 75°C
Operating Temperature Range for CUB5PB00 depends on
display color and intensity level as per below:
INTENSITY LEVEL TEMPERATURE
Red Display
1 & 2 -35 to 75°C
3-35 to 70°C
4-35 to 60°C
5-35 to 50°C
Green Display
1 & 2 -35 to 75°C
3-35 to 65°C
4-35 to 50°C
5-35 to 35°C
CAUTION: Risk of Danger.
Read complete instructions prior to
installation and operation of the unit.
CAUTION: Risk of electric shock.
0.13 [3.3]
[43.4]
1.71
2.95 [74.9]
SEL
0.15 [3.8]
1.54 [39.1]
RST
1.29 [32.8]
2.62 [66.6]
1.29
[32.8]
DIMENSIONS In inches [mm] Note: Recommended minimum clearance (behind the panel) for mounting
clip installation is 2.15" (54.6) H x 3.00" (76.2) W.
C
C
US LISTED
US LISTED
UL
R
IND. CONT. EQ.
E137808
2
Drawing No. LP1133 Effective 06 2022
Storage Temperature: -35 to 85°C
Operating and Storage Humidity: 0 to 85% max. relative
humidity (non-condensing)
Vibration to IEC 68-2-6: Operational 5-500 Hz, 5 g
Shock to IEC 68-2-27: Operational 30 g
Altitude: Up to 2000 meters
5. CERTIFICATIONS AND COMPLIANCES:
CE Approved
EN 61326-1 Immunity to Industrial Locations
Emission CISPR 11 Class A
EN 61010-1: General Requirements
EN 61010-2-030: Particular Requirements for Testing and
Measuring Circuits
RoHS Compliant
UL Recognized: File #E179259
UL Listed: File #E137808
Type 4X Indoor/Outdoor Enclosure rating (Face only)
IP65 Enclosure rating (Face only)
IP20 Enclosure rating (Rear of unit)
6. CONNECTIONS: Wire clamping screw terminals
Wire Strip Length: 0.3" (7.5 mm)
Wire Gage: 30-14 AWG copper wire
Torque: 3.5 inch-lbs (0.395 N-m) max.
7. CONSTRUCTION: This unit is rated for Type 4X/IP65
requirements for indoor/outdoor use. Installation Category I,
Pollution Degree 2. High impact plastic case with clear
viewing window. Panel gasket and mounting clip included.
8. WEIGHT: 3.2 oz (100 g)
INSTALLING THE METER
Installation
The meter meets NEMA 4X/IP65 requirements when properly
installed. The unit is intended to be mounted into an enclosed
panel. Prepare the panel cutout to the dimensions shown.
Remove the panel latch from the unit. Slide the panel gasket over
the rear of the unit to the back of the bezel. The unit should be
installed fully assembled. Insert the unit into the panel cutout.
While holding the unit in place, push the panel latch over the
rear of the unit so that the tabs of the panel latch engage in the
slots on the case. The panel latch should be engaged in the
farthest forward slot possible. To achieve a
proper seal, tighten the latch screws
evenly until the unit is snug in the
panel (Torque to approx. 28 to 36
in-oz [0.202 to 0.26 N-m]). Do not
over-tighten the screws.
INSTALLATION ENVIRONMENT
The unit should be installed in a location that does not exceed
the operating temperature and provides good air circulation.
Placing the unit near devices that generate excessive heat should
be avoided.
The bezel should only be cleaned with a soft cloth and neutral
soap product. Do NOT use solvents. Continuous exposure to
direct sunlight may accelerate the aging process of the bezel.
Do not use tools of any kind (screwdrivers, pens, pencils, etc.)
to operate the keypad of the unit.
PANEL CUT-OUT
SETTING THE JUMPERS
Input Range Jumper
This jumper is used to select the proper input range. The input
range selected in programming must match the jumper setting.
Select a range that is high enough to accommodate the maximum
signal input to avoid overloads. To access the jumper, remove the
rear cover of the meter.
Remove/Replace The Rear Cover
To remove the rear cover, locate the cover locking tab below
the 2nd and 3rd input terminals. To release the tab, insert a small,
flat blade screwdriver between the tab and the plastic wall below
the terminals. Inserting the screwdriver will provide enough
pressure to release the tab locks. To replace the cover, align the
cover with the input terminals and press down until the cover
snaps into place.
PANEL
GASKET
BEZEL PANEL MOUNTING SCREW
NUT FASTENER
MOUNTING CLIP
2.68
[68 ]
+.6
1.30
-.0
[33 ]
-.000
+.025
-.000
+.024
+.6
-.0
WARNING: Exposed line voltage exists on the circuit
boards. Remove all power to the meter and load circuits
before accessing inside of the meter.
INPUT RANGE JUMPER
MAIN CIRCUIT
BOARD
20/50 mA
INPUT RANGE
JUMPER LOCATION
10 V
3
Effective 06 2022 Drawing No. LP1133
WIRING THE METER
Wiring Overview
Electrical connections are made via screw-clamp terminals
located on the back of the meter. All conductors should conform
to the meter’s voltage and current ratings. All cabling should
conform to appropriate standards of good installation, local codes
and regulations. It is recommended that the power supplied to
the meter (DC or AC) be protected by a fuse or circuit breaker.
Power Wiring
User Input Wiring
Input Wiring
CAUTION: Power input common is NOT isolated from
user and input commons. In order to preserve the safety
of the meter application, the power input common must
be suitably isolated from hazardous live earth referenced
voltage; or input common must be at protective earth ground
potential. If not, hazardous voltage may be present at the signal or
user inputs and input common terminals. Appropriate considerations
must then be given to the potential of the user and input commons
with respect to earth ground; and the common of the plug-in cards
with respect to input common.
Before connecting signal wires, the Input Range Jumper should be
verified for proper position.
Input Signal (self powered)
JUMPER
POSITION
MAX INPUT
CURRENT
10 VDC 30 VDC
20/50 mA DC 150 mA
Series Loop (must use separate supply for sensor power and
each CUB5)
2 Wire With External Power
2 Wire With MLPS Power Supply
2 Wire With Separate Sensor And CUB5 Power
USR COMM
USR
+9-28 VDC
COMM
INP +
PWR COMMON
+
-
DC Power
+9 to +28 VDC: +VDC
Power Common: -VDC
CAUTION: 9 to 28
VDC power circuit
is not isolated from
the signal circuit.
USR COMM
USR
+9-28 VDC
COMM
INP +
PWR COMMON
Sinking Logic
USR COMM
USR
The user input of the meter is
internally pulled up to +9 to
+28 V with 10 K resistance.
The input is active when it is
pulled low (<0 .7 V).
Connect external switching device between the
User Input terminal and User Input Common.
}
-+
COMM
INP+
COMM
INP +
MODEL
INPUT POWER:
OUTPUT POWER:
85-250 VAC, 50/60Hz, 14VA
OPERATING TEMP: 0° TO 60°C
12VDC UNREG. @ 400mA
+12V
DC COMMON
M3424B
TERMINAL
AC INPUT
RED LION CONTROLS
YORK, PA. MADE IN U.S.A.
MLPS1
!
COMM
INP +
+VDC
COMM
EXTERNAL POWER
2 WIRE TRANSMITTER
+
_
MODEL
INPUT POWER:
OUTPUT POWER:
85-250 VAC, 50/60Hz, 14VA
OPERATING TEMP: 0° TO 60°C
12VDC UNREG. @ 400mA
+12V
DC COMMON
M3424B
TERMINAL
AC INPUT
RED LION CONTROLS
YORK, PA. MADE IN U.S.A.
MLPS1
!JUMPER
POSITION
20/50 mA DC
2 WIRE TRANSMITTER
INP +
COMM
EXTERNAL POWER
COMM
COMM +VDC
+VDC
_
+
JUMPER
POSITION
20/50 mA DC
2 WIRE TRANSMITTER
COMM
INP +
_
+
MODEL
INPUT POWER:
OUTPUT POWER:
85-250 VAC, 50/60Hz, 14VA
OPERATING TEMP: 0° TO 60°C
12VDC UNREG. @ 400mA
+12V
DC COMMON
M3424B
TERMINAL
AC INPUT
RED LION CONTROLS
YORK, PA. MADE IN U.S.A.
MLPS1
!JUMPER
POSITION
20/50 mA DC
2 WIRE TRANSMITTER
INP +
COMM
EXTERNAL POWER
COMM +VDC
+
_
MODEL
INPUT POWER:
OUTPUT POWER:
85-250 VAC, 50/60Hz, 14VA
OPERATING TEMP: 0° TO 60°C
12VDC UNREG. @ 400mA
+12V
DC COMMON
M3424B
TERMINAL
AC INPUT
RED LION CONTROLS
YORK, PA. MADE IN U.S.A.
MLPS1
!JUMPER
POSITION
20/50 mA DC
4
Drawing No. LP1133 Effective 06 2022
LIMITED WARRANTY
(a) Red Lion Controls Inc. (the “Company”) warrants that all
Products shall be free from defects in material and workmanship
under normal use for the period of me provided in “Statement
of Warranty Periods” (available at www.redlion.net) current at
the me of shipment of the Products (the “Warranty Period”).
EXCEPT FOR THE ABOVE-STATED WARRANTY, COMPANY
MAKES NO WARRANTY WHATSOEVER WITH RESPECT
TO THE PRODUCTS, INCLUDING ANY (A) WARRANTY OF
MERCHANTABILITY; (B) WARRANTY OF FITNESS FOR
A PARTICULAR PURPOSE; OR (C) WARRANTY AGAINST
INFRINGEMENT OF INTELLECTUAL PROPERTY RIGHTS OF
A THIRD PARTY; WHETHER EXPRESS OR IMPLIED BY LAW,
COURSE OF DEALING, COURSE OF PERFORMANCE, USAGE
OF TRADE OR OTHERWISE. Customer shall be responsible for
determining that a Product is suitable for Customer’s use and that
such use complies with any applicable local, state or federal law.
(b) The Company shall not be liable for a breach of the warranty
set forth in paragraph (a) if (i) the defect is a result of Customer’s
failure to store, install, commission or maintain the Product
according to specicaons; (ii) Customer alters or repairs such
Product without the prior wrien consent of Company.
(c) Subject to paragraph (b), with respect to any such Product
during the Warranty Period, Company shall, in its sole discreon,
either (i) repair or replace the Product; or (ii) credit or refund the
price of Product provided that, if Company so requests, Customer
shall, at Company’s expense, return such Product to Company.
(d) THE REMEDIES SET FORTH IN PARAGRAPH (c) SHALL
BE THE CUSTOMER’S SOLE AND EXCLUSIVE REMEDY AND
COMPANY’S ENTIRE LIABILITY FOR ANY BREACH OF THE
LIMITED WARRANTY SET FORTH IN PARAGRAPH (a).
BY INSTALLING THIS PRODUCT, YOU AGREE TO THE TERMS
OF THIS WARRANTY, AS WELL AS ALL OTHER DISCLAIMERS
AND WARRANTIES IN THIS DOCUMENT.
Setpoint (Output) Wiring
Serial Communication Wiring
RED LION CONTROLS TECHNICAL SUPPORT
If for any reason you have trouble operating, connecting, or
simply have questions concerning your new product, contact Red
Lion’s technical support.
Support: support.redlion.net
Website: www.redlion.net
Inside US: +1 (877) 432-9908
Outside US: +1 (717) 767-6511
Red Lion Controls, Inc.
20 Willow Springs Circle York, PA 17406
COPYRIGHT
©2022 Red Lion Controls, Inc. All rights reserved. Red Lion
and the Red Lion logo are trademarks of Red Lion Controls,
Inc. All other company and product names are trademarks of
their respective owners.
COM
N.C.
N.O.
OSNK1
OSNK2
COM
SINGLE SETPOINT RELAY PLUG-IN CARD
COM N.O. N.C.
ELECTRICAL CONNECTIONS
DUAL SETPOINT N-FET OPEN DRAIN PLUG-IN CARD
Output Common is not isolated from DC Power Common.
Load must be wired between OSNK terminal and V+ of the
load supply.
CO
M
OSNK 1(2)
(30 V MAX.)
ELECTRICAL CONNECTIONS
SERIAL COMMUNICATIONS PLUG-IN CARD
RJ11 CONNECTOR PIN OUTS
N/C
RS485
2
COMM
A+
B-
N/C
534
N/C
RS232
5
N/C
TX
N/C
43
COMM
COMM
2
RX
61
61

This manual suits for next models

2

Other red lion Measuring Instrument manuals

red lion APLTC User manual

red lion

red lion APLTC User manual

red lion PAX LITE User manual

red lion

red lion PAX LITE User manual

red lion PAX Lite PAXLHV User manual

red lion

red lion PAX Lite PAXLHV User manual

red lion APLCL User manual

red lion

red lion APLCL User manual

red lion CUB5 Series User manual

red lion

red lion CUB5 Series User manual

red lion DITAK 6 User manual

red lion

red lion DITAK 6 User manual

red lion APLR User manual

red lion

red lion APLR User manual

red lion DP5 User manual

red lion

red lion DP5 User manual

red lion PAXR0120 User manual

red lion

red lion PAXR0120 User manual

red lion PAXI-1/8 User manual

red lion

red lion PAXI-1/8 User manual

red lion PAXI User manual

red lion

red lion PAXI User manual

red lion APOLLO IMH Series User manual

red lion

red lion APOLLO IMH Series User manual

red lion CUB 5V Series User manual

red lion

red lion CUB 5V Series User manual

red lion CUB5VR00 User manual

red lion

red lion CUB5VR00 User manual

red lion CUB 5TC-K User manual

red lion

red lion CUB 5TC-K User manual

red lion PAXLA User manual

red lion

red lion PAXLA User manual

red lion PAXLI Instruction Manual

red lion

red lion PAXLI Instruction Manual

red lion PM-50 User manual

red lion

red lion PM-50 User manual

red lion APOLLO User manual

red lion

red lion APOLLO User manual

red lion DAM00PDP1SA00000 User manual

red lion

red lion DAM00PDP1SA00000 User manual

red lion DITAK 8 User manual

red lion

red lion DITAK 8 User manual

red lion LD2A User manual

red lion

red lion LD2A User manual

red lion PAXC0000 Manual

red lion

red lion PAXC0000 Manual

red lion PAXLTC User manual

red lion

red lion PAXLTC User manual

Popular Measuring Instrument manuals by other brands

SIGNIFY EA1440 instruction manual

SIGNIFY

SIGNIFY EA1440 instruction manual

SEFRAM MW 3352 user manual

SEFRAM

SEFRAM MW 3352 user manual

Rohde & Schwarz ZND Getting started

Rohde & Schwarz

Rohde & Schwarz ZND Getting started

Sierra Smart-Trak 100 series instruction manual

Sierra

Sierra Smart-Trak 100 series instruction manual

TRUGLO TG7630G manual

TRUGLO

TRUGLO TG7630G manual

Microtek Medi-7000 quick start guide

Microtek

Microtek Medi-7000 quick start guide

Hanna Instruments HI 709 instructions

Hanna Instruments

Hanna Instruments HI 709 instructions

Tektronix OI tek P5200A Series Installation and safety instructions

Tektronix

Tektronix OI tek P5200A Series Installation and safety instructions

DIOXCARE DX700 user manual

DIOXCARE

DIOXCARE DX700 user manual

BEKA BA354D manual

BEKA

BEKA BA354D manual

Farmcomp Unimeter Digital Operation instructions

Farmcomp

Farmcomp Unimeter Digital Operation instructions

Spectra Precision HD150 user manual

Spectra

Spectra Precision HD150 user manual

Voltmaster MCM 1 operating manual

Voltmaster

Voltmaster MCM 1 operating manual

Trotec BZ15C operating manual

Trotec

Trotec BZ15C operating manual

Harbor Freight Tools PITTSBURGH 63655 Owner's manual & safety instructions

Harbor Freight Tools

Harbor Freight Tools PITTSBURGH 63655 Owner's manual & safety instructions

Hach POCKET COLORIMETER II instruction manual

Hach

Hach POCKET COLORIMETER II instruction manual

M-system R1MS-GH3 instruction manual

M-system

M-system R1MS-GH3 instruction manual

ABLE RHEONIK  RHM NT Series Installation & maintenance instructions

ABLE

ABLE RHEONIK RHM NT Series Installation & maintenance instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.