manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Hanna Instruments
  6. •
  7. Measuring Instrument
  8. •
  9. Hanna Instruments HI 709 User manual

Hanna Instruments HI 709 User manual

Manganese High Range
Dear Customer,
Thank you for choosing a Hanna Instruments Product.
Please read this instruction manual carefully before using the instrument. If you need
additional technical information, do not hesitate to e-mail us at [email protected]
or view our worldwide contact list at www.hannainst.com.
Preliminary examination:
Please examine this product carefully. Make sure that the instrument is not damaged. If
any damage occurred during shipment, please notify your Dealer.
Each HI 709 meter is supplied complete with:
• Two Sample Cuvettes and Caps
• Six packets of Reagent A
• Six packets of Reagent B
• 1 x 1.5V AAA Battery
• Instruction Manual
HI 709
Functional description:
Errors and warnings:
Light High: There is too much light to perform a measurement.
Please check the preparation of the zero cuvette.
Light Low: There is not enough light to perform a measurement.
Please check the preparation of the zero cuvette.
Inverted Cuvettes: The sample and the zero cuvette are inverted.
Under Range: A blinking “0.0” indicates that the sample absorbs
less light than the zero reference. Check the procedure and make sure
you use the same cuvette for reference (zero) and measurement.
Over Range: A flashing value of the maximum concentration indicates
an over range condition. The concentration of the sample is beyond
the programmed range: dilute the sample and re-run the test.
Battery Low: The battery must be replaced soon.
Dead Battery: This indicates that the battery is dead and must be
replaced. Once this indication is displayed, normal operation of the
instrument will be interrupted. Change the battery and restart the
meter.
1. Dust cover.
2. Cuvette with cap.
3. Cuvette holder.
4. Liquid Crystal Display.
5. Button.
For more details about spare parts and accessories
see “Accessories”.
www.hannainst.com
Technical specifications:
Range 0.0 to 20.0 ppm
Resolution 0.1 ppm
Accuracy ±0.2 ppm ±5% of reading @ 25 °C / 77 °F
Light Source Light Emitting Diode @ 525 nm
Light Detector Silicon Photocell
Method Adaptation of the
Standard Methods for the Examination
of Water and Wastewater, 18th edition
, Periodate
method. The reaction between manganese and the
reagent causes a pink tint in the sample.
Environment 0 to 50 °C (32 to 122 °F);
max 95% RH non-condensing
Battery Type 1 x 1.5V AAA
Auto-Shut off After 10 minutes of non-use
Dimensions 86.0 x 61.0 x 37.5 mm (3.4 x 2.4 x 1.5”)
Weight 64 g (2.3 oz.)
www.ponpe.co
m
[email protected]
•Turn the meter on by pressing the button.
All segments will be displayed. When the
display shows “Add”, “C.1” with “Press”
blinking, the meter is ready.
•Fill the cuvette with 10 mL of unreacted
sample and replace the cap. Place the cuvette
into the meter and close the meter’s cap.
•Press the button. When the display shows
“Add”, “C.2” with “Press” blinking the
meter is zeroed.
•Remove the cuvette from the meter and
unscrew the cap. Add the content of one
packet of HI 709A-0 reagent. Replace the
cap and shake gently for 2 minutes.
•Unscrew the cap and add the content of one
packet of HI 709B-0 reagent. Replace the
cap and invert gently for 2 minutes. Place
the cuvette back into the meter.
•Press and hold the button until the timer is
displayed on the LCD (the display will show
the countdown prior to the measurement)
or, alternatively, wait for 1 minute and
30 seconds and press the button.
•The instrument displays the concentration in
ppm of manganese. The meter automatically
turns off after 10 minutes.
10 mL
REAGENT SETS
HI 709-25 Reagent for 25 Manganese High Range Tests
OTHER ACCESSORIES
HI 709-11 Manganese HR Certified Standard Kit
HI 731318 Cloth for wiping cuvettes (4 pcs.)
HI 731321 Glass cuvettes (4 pcs.)
HI 731225 Black Cuvette Cap for Checker HC (4 pcs.)
HI 740028 1.5V AAA batteries (4 pcs.)
HI 93703-50 Cuvettes cleaning solution (230 mL)
Recommendations for Users
For additional information, contact your
dealer or the nearest
Hanna Customer Service Center.
To find a Hanna Office in your area,
visit our web site:
www.hannainst.com
Hanna Instruments reserves the right to modify the design, construction or
appearance of its products without advance notice.
Battery management
IST709 07/15
Measurement procedure: Accessories:Tips for an accurate measurement
•It is important that the sample does not contain any debris.
•Whenever the cuvette is placed into the measurement cell, it must be dry
outside, and completely free of fingerprints, oil and dirt. Wipe it thoroughly with
HI 731318 or a lint-free cloth prior to insertion.
•Shaking the cuvette can generate bubbles, causing higher readings. To obtain
accurate measurements, remove bubbles by swirling or by gently tapping the
cuvette.
•Do not let the reacted sample stand for too long after reagent is added, as
accuracy will be affected.
•After the reading it is important to immediately discard the sample, otherwise
the glass might become permanently stained.
To save the battery, the instrument shuts down after 10 minutes of non-use.
One fresh battery lasts for a minimum of 5000 measurements. When the battery is dead
the instrument will display “bAd” then ”bAt” for 1 second and then turns off.
To restart the instrument, the battery must be replaced with a new one.
To replace the instrument’s battery:
•Turn the instrument off by holding the button until the meter shuts off.
•Turn the instrument upside down and remove the battery cover with a screwdriver.
•Remove the battery from its location and replace it with a new one, inserting the
negative end first.
•Insert the battery cover and replace the screw with a screwdriver.
Before using this product, make sure that it is entirely suitable for your specific application and for the
environment in which it is used.
Operation of this instrument may cause unacceptable interferences to other electronic equipment, thus
requiring the operator to take all necessary steps to correct interferences.
Any variation introduced by the user to the supplied equipment may degrade the instrument’s EMC
performance.
To avoid damage or burns, do not put the instrument in microwave oven. For the safety of you and the
instrument do not use or store the instrument in hazardous environments.
[email protected]
www.ponpe.co
m

Other Hanna Instruments Measuring Instrument manuals

Hanna Instruments HI 99181 User manual

Hanna Instruments

Hanna Instruments HI 99181 User manual

Hanna Instruments HI97745 User manual

Hanna Instruments

Hanna Instruments HI97745 User manual

Hanna Instruments C 215 User manual

Hanna Instruments

Hanna Instruments C 215 User manual

Hanna Instruments HI764 User manual

Hanna Instruments

Hanna Instruments HI764 User manual

Hanna Instruments HALO 2 HI9810422 User manual

Hanna Instruments

Hanna Instruments HALO 2 HI9810422 User manual

Hanna Instruments HI97706 User manual

Hanna Instruments

Hanna Instruments HI97706 User manual

Hanna Instruments HI 99141 User manual

Hanna Instruments

Hanna Instruments HI 99141 User manual

Hanna Instruments HI 8314 User manual

Hanna Instruments

Hanna Instruments HI 8314 User manual

Hanna Instruments HI98192 User manual

Hanna Instruments

Hanna Instruments HI98192 User manual

Hanna Instruments HI 747 User manual

Hanna Instruments

Hanna Instruments HI 747 User manual

Hanna Instruments HI 4104 User manual

Hanna Instruments

Hanna Instruments HI 4104 User manual

Hanna Instruments HI 720 User manual

Hanna Instruments

Hanna Instruments HI 720 User manual

Hanna Instruments HI 9828 User manual

Hanna Instruments

Hanna Instruments HI 9828 User manual

Hanna Instruments HI96738 User manual

Hanna Instruments

Hanna Instruments HI96738 User manual

Hanna Instruments HI 96715C User manual

Hanna Instruments

Hanna Instruments HI 96715C User manual

Hanna Instruments HI 99301 User manual

Hanna Instruments

Hanna Instruments HI 99301 User manual

Hanna Instruments HI 98180 User manual

Hanna Instruments

Hanna Instruments HI 98180 User manual

Hanna Instruments HI 9811-5 User manual

Hanna Instruments

Hanna Instruments HI 9811-5 User manual

Hanna Instruments HI981954 User manual

Hanna Instruments

Hanna Instruments HI981954 User manual

Hanna Instruments HI762 User manual

Hanna Instruments

Hanna Instruments HI762 User manual

Hanna Instruments Ammonia Medium Range User manual

Hanna Instruments

Hanna Instruments Ammonia Medium Range User manual

Hanna Instruments HI 4421 User manual

Hanna Instruments

Hanna Instruments HI 4421 User manual

Hanna Instruments HI 96108 User manual

Hanna Instruments

Hanna Instruments HI 96108 User manual

Hanna Instruments HI 84184 User manual

Hanna Instruments

Hanna Instruments HI 84184 User manual

Popular Measuring Instrument manuals by other brands

NeurOptics NPi-300 quick start guide

NeurOptics

NeurOptics NPi-300 quick start guide

NPI VA-10M operating instructions

NPI

NPI VA-10M operating instructions

Kofloc FM31 Series instruction manual

Kofloc

Kofloc FM31 Series instruction manual

KING 7430 Series installation instructions

KING

KING 7430 Series installation instructions

Anritsu VNA Master MS2024B Maintenance manual

Anritsu

Anritsu VNA Master MS2024B Maintenance manual

Rohde & Schwarz FSH4 operating manual

Rohde & Schwarz

Rohde & Schwarz FSH4 operating manual

Omega DP25B-S Quick start quide

Omega

Omega DP25B-S Quick start quide

ATAGO PAL-41S instruction manual

ATAGO

ATAGO PAL-41S instruction manual

Stack Clubman ST200 manual

Stack

Stack Clubman ST200 manual

Leica GLOW800 user manual

Leica

Leica GLOW800 user manual

Textron Keithley System SourceMeter 2601B-PULSE quick start guide

Textron

Textron Keithley System SourceMeter 2601B-PULSE quick start guide

Topcon GTS-230W Series instruction manual

Topcon

Topcon GTS-230W Series instruction manual

Amprobe VPC-20 instruction manual

Amprobe

Amprobe VPC-20 instruction manual

Raycus RFL-B500D user guide

Raycus

Raycus RFL-B500D user guide

Fluidwell F040-U manual

Fluidwell

Fluidwell F040-U manual

Desco 19665 Installation, operation and maintenance

Desco

Desco 19665 Installation, operation and maintenance

Horizon Fitness HD-S2 user guide

Horizon Fitness

Horizon Fitness HD-S2 user guide

OWL ZOOM 2 Series Operation guide

OWL

OWL ZOOM 2 Series Operation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.