Redback A4573 User manual

www.altronics.com.au
User manual revision number: 1.0 25/11/2015
Operating Manual
A 4573 Alert/Evac Module with Multiple Chimes
Redback® Proudly Made In Australia
Overview
The A 4573 module generates pre announcement chimes and alert and evacuation tones for selected Redback® products.
Separate volume controls are included for adjustment of the alert/evac tone level, the chime level and the message
voice-over level. The chime and alert/evac tones are triggered by closing contacts via a ve way euro block. These triggers
can be set to momentary or alternate action by on board DIP switches.
Chimes included on the module include pre announcement, Ding Dong, repeating Bing and repeating Bong. All of these
are DIP switch selectable.
The module is also tted with a switch over option which changes the evacuation tone from the Alert tone to the
Evacuation tone after a set time. This can be adjusted from 30 seconds to 270 seconds in 30 second increments or it can
be switched off altogether.
A microphone has been included which is used to record an emergency voice over message if required. This message can
be turned on via DIP switches, and will play twice after the evacuation tone has repeated four times.
Important Note:
The evacuation tone for this device conforms to re evacuation standards AS1670.4.2004
The evacuation tone (temporal pattern) conforms to international standards.
The A 4573 module is compatible with the following Redback ® products.
Compatible Ampliers Compatible Mixers
A 4036A 40 Watt Amplier A 4425A
A 4041A 60 Watt Amplier A 4480
A 4046A 100 Watt Amplier
A 4375A 125 Watt Amplier Suitable Wallplates for remote triggering*
A 4385A 250Watt Amplier A 2078B
A 4275 125 Watt Amplier A 2081
A 4285 250 Watt Amplier
Distributed by Altronic Distributors Pty. Ltd.
Phone: 1300 780 999 Fax: 1300 790 999 Internet: www.altronics.com.au

www.altronics.com.auRedback® Proudly Made In Australia
2
Fig 1
Installation
The A 4573 module needs to be tted inside the Redback ® compatible product by following the following steps.
1) Switch off and remove power from the unit the A 4573 is to be tted to.
2) Remove the lid from the unit.
3) Unscrew the small protector plate on the rear panel to reveal the mounting holes for the A 4573.
4) Line up the A 4573 with the relevant holes in the rear panel, ensure the trimpots on the board are accessible.
5) Using the screws provided attach the A 4573 mdule to the rear panel via the green euro block.
6) Plug the 10 way IDC cable to the 10 way header situated inside the Redback® product. (Refer to the instructions
supplied with the Redback® compatible product).
7) Plug the plastic bushes supplied into the holes on the rear panel through which the trimpots are accessed.
8) The unit is now ready for operation.
Voice over
levelTrigger contacts
10 Way IDC
Cable (To amplifier)
Chime
level
Alert/Evac
level
Switch 1
DIP Switches
Microphone
+-
Red Blk
AL CH2 CH1/
CAN
GND
EV
Triggering the tones
The unit is triggered by closing the contacts on the 5 way pluggable header. There are four different trigger inputs as
shown in Fig 2.
Evac tone - triggered by a closed contact between EV (alert tone) and GND (ground).
Alert tone - triggered by a closed contact between AL (alert tone) and GND (ground).
Chime 2 - triggered by a closed contact between CH2 (chime 2) and GND (ground).
Chime 1/Cancel - triggered by a closed contact between CH1/CAN (chime 1/cancel) and GND (ground).
The alert and evac triggers can be set to momentary or latched action. In momentary operation the alert or evac tones will
operate only while the trigger is activated. In latched operation the tones will operate continuously after they have been
triggered, even with a momentary contact. This option is set by DIP switch 1 (Refer to table 2 for DIP switch settings).
Switch Over Option
The A 4573 is equipped with a “switch over” option which switches the unit from the Alert tone to the Evacuation tone
automatically. This can be adjusted from 30 seconds to 270 seconds in 30 second increments or it can be switched off
entirely. This is adjusted by switch 1 (refer to table 1 for selection details).
Fig 2
REDBACK® A 4573 Alert/Evac Module

www.altronics.com.au Redback® Proudly Made In Australia
3
Voice Over message
The A 4573 has a voice over option which is used to playback a recorded messsage. This is enabled by switching DIP
switch 2 to “ON” (Refer to table 2 for DIP Switch settings). Once enabled the recorded message will play twice after four
cycles of the evac tone.
Note: this voice over will only operate when the A 4573 is in evac mode.
To record a message, connect the supplied microphone to the 2 way euro block as shown in gure 1. To start recording,
set DIP switch 8 to “ON” and start talking into the microphone. When nished recording, set the DIP switch back to
‘OFF”.
Adjusting Volume Levels
The output levels for the chime, alert/evac tones and the voice over are all adjustable via trimpots as shown in Fig 1.
Note: The Alert and Evac tones are adjusted using the same trimpot. They cannot be adjusted separately.
Chime Options
There are two contacts available for activating the chime tones, and there are four different chimes available (pre
announcement, Ding Dong, Repeating Bing and Repeating Bong). It is possible to have two different chimes available to
use at the same time, but if the cancel trigger is required then the module is limited to one available chime trigger (Refer
to table 3 for selection details).
DIP switches and switch 1 settings
Table 1: Switch 1 Settings
SW1 Pos Switch Over Option
0 Disabled
1 Alert swtiches to Evac after 30 seconds
2 Alert swtiches to Evac after 60 seconds
3 Alert swtiches to Evac after 90 seconds
4 Alert swtiches to Evac after 120 seconds
5 Alert swtiches to Evac after 150 seconds
6 Alert swtiches to Evac after 180 seconds
7 Alert swtiches to Evac after 210 seconds
8 Alert swtiches to Evac after 240 seconds
9 Alert swtiches to Evac after 270 seconds
REDBACK® A 4573 Alert/Evac Module
Table 2: DIP Switch Settings
SWITCH ON OFF
1 Momentary Alert Latched/Continuous Alert
& Evac Operation. & Evac Operation.
2 Voiceover ON. Voiceover OFF.
3 Not Used. Not Used.
8 Mic Recording Mic Recording
ON. OFF.
Table 3: DIP Switch Settings For Tones
DIP CHIME CONTACT
4 5 6 7 CH2 CAN/CH1
OFF OFF OFF OFF Pre Announce Ding Dong
ON OFF OFF OFF Pre Announce Repeating Bong
OFF ON OFF OFF Pre Announce Repeating Bing
OFF OFF ON OFF Pre Announce CANCEL
OFF OFF OFF ON Ding Dong Pre Announce
ON ON ON ON Ding Dong Repeating Bong
OFF ON ON ON Ding Dong Repeating Bing
ON OFF ON ON Ding Dong CANCEL
ON ON OFF ON Repeating Bong Pre Announce
ON ON ON OFF Repeating Bong Ding Dong
OFF OFF ON ON Repeating Bong Repeating Bing
OFF ON OFF ON Repeating Bong CANCEL
OFF ON ON OFF Repeating Bing Pre Announce
ON ON OFF OFF Repeating Bing Ding Dong
ON OFF ON OFF Repeating Bing Repeating Bong
ON OFF OFF ON Repeating Bing CANCEL

www.altronics.com.auRedback® Proudly Made In Australia
4
Fig 3
Fig 4
A 2078B Remote Plate
A 2081 Remote Plate
Cancel
Switch
Evac
Switch
Alert
Switch
Alert
Lamp
Evac
Lamp
- + - +
A 2078B REMOTE WALL PLATE
Evac CancelAlert
AL CH2 CH1/
CAN
GND
EV
Evac
Alert
Chime Cancel
A 2081 REMOTE WALL PLATE
AL CH2 CH1/
CAN
GND
EV
Alert
Switch
- + - +
Chime
Switch
Evac
Switch
Alert
Lamp
Evac
Lamp
Cancel
Switch
- +
Chime
Lamp
Remote Triggering of the tones
It is possible to remotely activate the A 4573 from
the Redback® A 2078B and A 2081 wall plates.
Figures 3 and 4 illustrate the wiring connections
required.
Note: The A 2078B and A 2081 were never
designed to be connected to the A 4573 module.
Hence there is no way to illuminate the switch
lamps which require 24V DC to operate. So no
visual indication of the switches being activated is
possible.
REDBACK® A 4573 Alert/Evac Module
Table of contents
Other Redback Security System manuals
Popular Security System manuals by other brands

MARPOWER
MARPOWER 22-K Series manual

Baldwin Boxall
Baldwin Boxall BVECASE5BATT Installation details

INNOTEC
INNOTEC 100 Series Installation & operation instructions

SECO-LARM
SECO-LARM ENFORCER SD-7201GC-PEQ installation manual

Amico
Amico ALERT-1 Installation & maintenance manual

Metasys
Metasys IFC-1010 Installing

Vimar
Vimar Elvox ZSEM Installation and operation manual

eTIGER
eTIGER ES-D4A manual

Federal Signal Corporation
Federal Signal Corporation Premium Vision Operation and configuration instructions

steute
steute ZS 80 KST Extreme Series Mounting and wiring instructions

Hewlett Packard Enterprise
Hewlett Packard Enterprise Aruba ARBT0033 Startup guide

Cobra
Cobra XRS 9345 operating instructions