REDZ BSB Series User manual

BSB Series Industrial Unmanaged Ethernet SwitchBSB Series Industrial Unmanaged Ethernet Switch
with 10/100Base-T(x) Ports and/or BPL (with 10/100Base-T(x) Ports and/or BPL (
Broadband Power Line Link) and/or SFP UplinkBroadband Power Line Link) and/or SFP Uplink
Ports and/or PoE+ Ports User ManualPorts and/or PoE+ Ports User Manual
1. About BSB Series Industrial Unmanaged Ethernet Switch1. About BSB Series Industrial Unmanaged Ethernet Switch
BSB Series Industrial Unmanaged Ethernet Switches are designed for industrial-grade Ethernet, and particularly for
facilities of rugged industry and infrastructure. BSB Series Industrial Unmanaged Ethernet Switches are tailored to
perform various features, such as wide temperature, wide range power input range... etc. Thus, BSB Series Industrial
Unmanaged Ethernet Switches are the best choice for facility management, sewage treatment, power utility,
telecommunication, transportation and all other applications that require reliable Ethernet connectivity.
BSB Series has models also with REDZ Broadband Power Line (BPL) communication. BPL link allows device to
communicate with full transparent TCP/IP standard over Low Voltage power lines and allows easy connection
between TCP/IP based terminals without use of extra cables.
BSB Series has models also with SFP ports for Fiber connectivity. BSB Series with SFP ports offers fiber and ethernet
connectivity in same device with plug and play SFP ports. Wide range of SFP modules are available to be used with
BSB series.
BSB Series has models also with PoE+ ports for Power over Ethernet connectivity. BSB Series Industrial Unmanaged
Ethernet Switches with PoE+ ports can power up to 36W device on a single port and total combined power supply is
90W. Additional PoE splitter can be used to separate power and data for field devices.
2. Hardware Features2. Hardware Features
BSB Series Industrial Unmanaged Ethernet Switches has the versions with and without BPL (Broadband Power Line) Link
and with and without SFP Ports.
2.1 Features2.1 Features
Supports up to 8 x 10/100Base-T(X) ports
AC or DC wide range power options
Supports Full/Half-Duplex, auto MDI/MDI-X on each port
Wide operating temperature range from -25 to 70 °C AC and -40 to 85 °C DC power input versions
Rugged Metal IP-40 housing design

DIN-Rail mounting
2.2 Extra Features for Models with BPL2.2 Extra Features for Models with BPL
Supports up to 7 x 10/100Base-T(X) ports + 1 x BPL link
Wide range 3 phase AC input
Supports up to 30Mbps PHY rate on BPL with Up to 10 hops and 1000 nodes
Up to 432 sub-carriers from 2 to 28MHz analog bandwidth
Support LDPC-C FEC with 128-bit AES core
Plug and play with Master/Slave selection via switch
2.3 Features for Models with SFP Ports2.3 Features for Models with SFP Ports
Supports 8 x 10/100Base-T(X) ports
Supports 2 x 10/100/1000 SFP Ports
Plug-and-play without additional settings
AC or DC wide range power options
Wide operating temperature range from -25 to 70 °C AC and -40 to 85 °C DC power input versions
Rugged Metal IP-40 housing design
DIN-Rail mounting
2.4 Features for Models with PoE+ Ports2.4 Features for Models with PoE+ Ports
Supports 8 x 10/100Base-T(X) ports
Supports PoE+ on all ports
90 Watt Power Supply combined for all ports
Maximum 36 Watt per port
IEEE 802.3AF-2003 and 802.3AT-2009 compliant
Plug-and-play without additional settings
100 - 240V AC (120 – 370V DC), 50Hz to 60Hz AC wide range power input
90Watt Power Supply
Wide operating temperature range from -30 to 80 °C
Rugged Metal IP-40 housing design

DIN-Rail mounting
3. Installation3. Installation
Each switch has a Din-Rail kit on rear panel. The Din-Rail kit helps switch to fix on the Din-Rail. Slant the switch and
mount the metal spring to Din-Rail.
Then Push the switch toward the Din-Rail until you heard a “click” sound.
4. Front Panel Description4. Front Panel Description
4.14.1 BSB115 & BSB215BSB115 & BSB215

1. 10/100Base-T(X) Ethernet ports 1, 2, 3 and 4.
2. ETHERNET Activity LEDs for port 1, 2, 3 and 4. Blinks during ethernet activity.
3. 10/100Base-T(X) Ethernet port 5.
4. ETHERNET Activity LED for port 5. Blinks during ethernet activity.
4.24.2 BSB118 & BSB218BSB118 & BSB218
1. 10/100Base-T(X) Ethernet ports 1, 2, 3 and 4.
2. ETHERNET Activity LEDs for port 1, 2, 3 and 4. Blinks during ethernet activity.
3. ETHERNET Activity LEDs for port 5, 6, 7 and 8. Blinks during ethernet activity.
4. 10/100Base-T(X) Ethernet ports 5, 6, 7 and 8.
4.3 BSB120&BSB2204.3 BSB120&BSB220

1. 10/100Base-T(X) Ethernet ports 1, 2, 3 and 4.
2. ETHERNET Activity LEDs for port 1, 2, 3, 4, 5, 6, 7 and 8. Blinks during ethernet activity.
3. ETHERNET Activity LEDs for SFP Ports 1 and 2. There are 2 LEDs for each port. One Blinks during ethernet activity
and one is steady when speed is Gigabit .
4. 10/100Base-T(X) Ethernet ports 5, 6, 7 and 8.
5. 10/100/1000 SFP Ports 1 and 2.
4.44.4 BSB268BSB268
1. 10/100Base-T(X) Ethernet ports 1, 2, 3 and 4.
Supports PoE+ on all ports
90 Watt Power Supply combined for all ports
Maximum 36 Watt per port

2. ETHERNET Activity LEDs for port 1, 2, 3, 4, 5, 6, 7 and 8. Blinks during ethernet activity.
3. 10/100Base-T(X) Ethernet ports 5, 6, 7 and 8.
Supports PoE+ on all ports
90 Watt Power Supply combined for all ports
Maximum 36 Watt per port
4.54.5 BSB612BSB612
1. 10/100Base-T(X) Ethernet port.
2. BPL Activity LED. Blinks during BPL & Ethernet activity.
3. BPL Link LED. LED Turns ON if the link can be established.
4. Master Indication LED. LED Turns ON if the device is started as “Master” device.
5. Switch position to select the device as “Master” or “Slave”. Device must be repowered after changing the
setting to take into effect.
4.64.6 BSB615BSB615

1. 10/100Base-T(X) Ethernet ports 1, 2, 3 and 4.
2. ETHERNET Activity LEDs for port 1, 2, 3 and 4. Blinks during ethernet activity.
3. BPL Activity LED. Blinks during BPL & Ethernet activity.
4. BPL Link LED. LED Turns ON if the link can be established.
5. Master Indication LED. LED Turns ON if the device is started as “Master” device.
6. Switch position to select the device as “Master” or “Slave”. Device must be repowered after changing the
setting to take into effect.
4.74.7 BSB618 BSB618
1. 10/100Base-T(X) Ethernet ports 1, 2, 3 and 4.
2. ETHERNET Activity LEDs for port 1, 2, 3 and 4. Blinks during ethernet activity.

3. ETHERNET Activity LEDs for port 5, 6, and 7. Blinks during ethernet activity.
4. 10/100Base-T(X) Ethernet ports 5, 6, and 7.
5. BPL Activity LED. Blinks during BPL & Ethernet activity.
6. BPL Link LED. LED Turns ON if the link can be established.
7. Master Indication LED. LED Turns ON if the device is started as “Master” device.
8. Switch position to select the device as “Master” or “Slave”. Device must be repowered after changing the
setting to take into effect.
5. Top Panel Description5. Top Panel Description
5.1 BSB115 & BSB118 & BSB1205.1 BSB115 & BSB118 & BSB120
1. Power Input DC: 5-60V DC. Polarity protected so that the power input can be connected in any direction.
2. Power LED: Turns ON when there is power in device.
3. Reset Button: Reset the device.
5.2 BSB215 & BSB218 & BSB2205.2 BSB215 & BSB218 & BSB220

1. Power Input AC: 90 - 265V AC (100 – 370V DC), 47Hz to 63Hz AC input.
2. Power LED: Turns ON when there is power in device.
3. Reset Button: Reset the device.
5.3 BSB2685.3 BSB268
1. Power Input AC: 100 - 240V AC (120 – 370V DC), 50Hz to 60Hz AC Wide Range Power Input
90Watt Power Supply
2. Reset Button: Reset the device.

5.4 BSB612 & BSB615 & BSB6185.4 BSB612 & BSB615 & BSB618
1. Power Input AC: 3 phase input, 110V–240V/50-60Hz. It is also ok to connect only single phase to the device
such as L1-N connection only.
AC Power supply use L1-N only. Phase 2-3 connections are used to BPL signal transmission.
2. Power LED: Turns ON when there is power in device.
6. Ethernet Cables, SFP Module Options6. Ethernet Cables, SFP Module Options
BSB Series Industrial Unmanaged Ethernet Switches have standard Ethernet ports. According to the link type, the
switches use CAT 3, 4, 5, 5e UTP cables to connect to any other network device (PCs, servers, switches, routers, or
hubs).
6.1 Cable Type and Specifications6.1 Cable Type and Specifications
CableCable TypeType Max. LengthMax. Length ConnectorConnector
10BASE-T Cat. 3, 4, 5 100-ohm UTP 100 m (328 ft) RJ-45
100BASE-TX Cat. 5 100-ohm UTP UTP 100 m (328 ft) RJ-45
6.2 ETH Cable Pin Assignments6.2 ETH Cable Pin Assignments
With 100BASE-TX/10BASE-T cable, pins 1 - 2 are used for transmitting data and pins 3 - 6 are used for receiving data.

Pin NumberPin Number DescriptionDescription
1 TD+
2 TD-
3 RD+
4 Not Used
5 Not Used
6 RD-
7 Not Used
8 Not Used
6.3 SFP Module Options6.3 SFP Module Options
Following SFP modules are available to be used with BSB SFP versons
Model NameModel Name DexcriptionDexcription SFP TypeSFP Type TechnicalTechnical
DetailsDetails ExplanationExplanation How to UseHow to Use Cables UsedCables Used
CE-GLC-FE-
100FX
155M, Dual
Fiber, Multi
Mode, 1310nm,
2KM, Industrial
100Mbit/s SFP
F2 Multi-mode
fiber; LC
connector; with
black or Beige
color coding
LFX (name
dependent on
manufacturer) –
1310 nm, for a
distance up to 2
km
Connect 2 x
same device on
both device
LC-LC MM
Duplex
CE-GLC-FE-
100LX
155M, Dual
Fiber, SM,
1310nm, 20KM,
Industrial
100Mbit/s SFP
Single-mode
fiber, LC
connector, with
blue color
coding
LX – 1310 nm,
for distances up
to 20 km
Connect 2 x
same device on
both device
LC-LC SM
Duplex
GLC-BX-20U
155M Bidi SFP,
1310nm-
TX/1550nm-RX,
20km, LC Port,
Industrial
100Mbit/s SFP
Single-mode
fiber, LC
connector, Bi-
Directional, with
blue and yellow
color coding
BX (officially
BX10) – 1550
nm/1310 nm,
Single Fiber Bi-
Directional 100
Mbit SFP
Transceivers,
paired as BX-U
(blue) and BX-D
(yellow) for
uplink and
downlink
respectively,
also for
distances up to
20 km.
Variations of
bidirectional
SFPs are also
manufactured
which higher
transmit power
versions with link
length
capabilities up
to 20 km.
Connect 1 x U
version on 1
device and 1 x D
version on other
device
LC-LC SM
Simplex
GLC-BX-20D
155M Bidi SFP,
1550nm-
TX/1310nm-RX,
20km, LC Port,
Industrial
100Mbit/s SFP
CE-GLC-T
10/100M
Copper SFP,
RJ45 Port, 100M,
Industrial
100Mbit/s SFP
Copper
twisted-pair
cabling, 8P8C
(RJ-45)
connector
100BASE-TX –
for distances up
to 100m.
Connect 2 x
same device on
both device
RJ45 Cable
GLC-SX-MMD
1.25G, Dual
Fiber, MM, 1Gbit/s SFP
1 Gbit/s multi-
mode fiber, LC
connector, with
SX – 850 nm,
for a maximum
of 550 m at 1.25
Gbit/s (gigabit
Ethernet). Other
multi-mode SFP
Connect 2 x
same device on LC-LC MM

850nm, 550m,
Industrial
black or beige
extraction lever
applications
support even
higher rates at
shorter
distances.
both device Duplex
CE-GLC-BX-
3U
1.25G Bidi SFP,
1310nm-
TX/1550nm-RX,
3km, SC or LC
Port, Industrial
1Gbit/s SFP
1 to 2.5 Gbit/s
single-mode
fiber, LC
connector, with
blue extraction
lever
BX (officially
BX10) – 1550
nm/1310 nm,
Single Fiber Bi-
Directional
Gigabit SFP
Transceivers,
paired as BX-U
and BX-D for
uplink and
downlink
respectively,
also for
distances up to
10 km. Variations
of bidirectional
SFPs are also
manufactured
which use 1550
nm in one
direction, and
higher transmit
power versions
with link length
capabilities up
to 80 km.
Connect 1 x U
version on 1
device and 1 x D
version on other
device
LC-LC SM
Simplex
CE-GLC-BX-
3D
1.25G Bidi SFP,
1550nm-
TX/1310nm-RX,
3km, SC or LC
Port, Industrial
1Gbit/s SFP
CE-GLC-BX-
10U
1.25G Bidi SFP,
1550nm-
TX/1310nm-RX,
10km, LC or SC
Port, Industrial
1Gbit/s SFP
CE-GLC-BX-
10D
1.25G Bidi SFP,
1550nm-
TX/1310nm-RX,
10km, LC or SC
Port, Industrial
1Gbit/s SFP
CE-GLC-BX-
20U
1.25G Bidi SFP,
1310nm-
TX/1550nm-RX,
20km, LC or SC
Port, Industrial
1Gbit/s SFP
CE-GLC-BX-
20D
1.25G Bidi SFP,
1550nm-
TX/1310nm-RX,
20km, LC or SC
Port, Industrial
1Gbit/s SFP
CE-GLC-BX-
40U
1.25G Bidi SFP,
1310nm-
TX/1550nm-RX,
40km, LC or SC
Port, Industrial
1Gbit/s SFP
CE-GLC-BX-
40D
1.25G Bidi SFP,
1550nm-
TX/1310nm-RX,
40km, LC or SC
Port, Industrial
1Gbit/s SFP
CE-GLC-T
10/100/1000M
Copper SFP,
RJ45 Port, 100M,
Industrial
1Gbit/s SFP
1 Gbit/s for
copper twisted-
pair cabling,
8P8C (RJ-45)
connector
1000BASE-T –
these modules
incorporate
significant
interface
circuitry for
Physical Coding
Sublayer
recoding and
can be used
only for gigabit
Ethernet
because of the
specific line
code. They are
not compatible
with (or rather:
do not have
equivalents for)
Fiber Channel.
Unlike non-SFP,
copper
Connect 2 x
same device on
both device
RJ45 Cable

1000BASE-T
ports integrated
into most
routers and
switches,
1000BASE-T
SFPs usually
cannot operate
at 100BASE-TX
speeds.
GLC-LH-SMD
1.25G, Dual
Fiber, 1310nm,
10km, Industrial
1Gbit/s SFP
Single Mode
fiber, LC
connector
LH – 1310 nm,
for a maximum
of 10KM at 1.25
Gbit/s (gigabit
Ethernet). Other
multi-mode SFP
applications
support even
higher rates at
shorter
distances.
Connect 2 x
same device on
both device
LC-LC SM
Duplex
GLC-LH-
SMD-20
1.25G, Dual
Fiber, 1310nm,
20km, Industrial
1Gbit/s SFP
Single Mode
fiber, LC
connector
LH – 1310 nm,
for a maximum
of 10KM at 1.25
Gbit/s (gigabit
Ethernet). Other
multi-mode SFP
applications
support even
higher rates at
shorter
distances.
Connect 2 x
same device on
both device
LC-LC SM
Duplex
NOTE:NOTE: Multi Mode Duplex should connect same Multi Mode Duplex
wavelength, like 850MM should connector MM 850nm, couldn't connect MM
1310.
Single Mode duplex should connect same Single Mode wavelength, SM
Duplex 1310 should connect SM 1310 Duplex, couldn't connect SM Duplex
1550NM.
Duplex couldn't connect Simplex BIDI.
Simplex BIDI only connect simplex BIDI U connect D, D couldn't connect D U
couldn't connect U.
Single Mode(SM) couldn't connect Multi Mode(MM).
6.4 PoE+ Cable Pin Assignments6.4 PoE+ Cable Pin Assignments
Pin NumberPin Number DataData
Pin 1 Rx +
Pin 2 Rx -
Pin 3 Tx +
Pin 4 Unused
Pin 5 Unused
Pin 6 Tx -
Pin 7 Unused
Pin 8 Unused

7. SFP Types7. SFP Types
The small form-factor pluggable (SFP) is a compact, hot-pluggable network interface module used for both
telecommunication and data communications applications. An SFP interface on networking hardware is a modular slot
for a media-specific transceiver in order to connect a fiber-optic cable or sometimes a copper cable.
The advantage of using SFPs compared to fixed interfaces (e.g. modular connectors in Ethernet switches) is that
individual ports can be equipped with any suitable type of transceiver as needed.
7.1 100Mbit/s SFP7.1 100Mbit/s SFP
- Multi-mode fiber, LC connector, with black or Beige color coding
SX – 850 nm, for a maximum of 550 m
- Multi-mode fiber, LC connector, with blue color coding
FS – 1300 nm, for a distance up to 5 km.
LFX (name dependent on manufacturer) – 1310 nm, for a distance up to 5 km.
Available SFP module from REDZ:
Model NameModel Name DescriptionDescription Cable UsedCable Used
CE-GLC-FE-100FX
155M, Dual Fiber, Multi
Mode, 1310nm, 2KM,
Industrial
LC-LC MM Duplex
- Single-mode fiber, LC connector, with blue color coding
LX – 1310 nm, for distances up to 20 km
Available SFP module from REDZ:
Model NameModel Name DescriptionDescription Cable UsedCable Used
CE-GLC-FE-100LX 155M, Dual Fiber, SM,
1310nm, 20KM, Industrial LC-LC SM Duplex
EX – 1310 nm, for distances up to 40 km
- Single-mode fiber, LC connector, with green color coding
ZX – 1550 nm, for distances up to 80 km, (depending on fiber path loss)
EZX – 1550 nm, for distances up to 160 km (depending on fiber path loss)
- Single-mode fiber, LC connector, Bi-Directional, with blue and yellow color coding
BX (officially BX10) – 1550 nm/1310 nm, Single Fiber Bi-Directional 100 Mbit SFP Transceivers, paired as BX-U (blue) and
BX-D (yellow) for uplink and downlink respectively, also for distances up to 10 km. Variations of bidirectional SFPs are
also manufactured which higher transmit power versions with link length capabilities up to 40 km.
Available SFP module from REDZ:
Model NameModel Name DescriptionDescription Cable UsedCable Used
GLC-BX-20U
155M Bidi SFP, 1310nm-
TX/1550nm-RX, 20km, LC
Port, Industrial
LC-LC SM Simplex
GLC-BX-20D
155M Bidi SFP, 1550nm-
TX/1310nm-RX, 20km, LC
Port, Industrial
LC-LC SM Simplex
- Copper twisted-pair cabling, 8P8C (RJ-45) connector
100BASE-TX – for distances up to 100m.
Available SFP module from REDZ:
Model NameModel Name DescriptionDescription Cable UsedCable Used

CE-GLC-T 10/100M Copper SFP, RJ45
Port, 100M, Industrial RJ45 Cable
7.2 1Gbit/s SFP7.2 1Gbit/s SFP
- 1 Gbit/s multi-mode fiber, LC connector, with black or beige extraction lever
SX – 850 nm, for a maximum of 550 m at 1.25 Gbit/s (gigabit Ethernet). Other multi-mode SFP applications support
even higher rates at shorter distances.
Available SFP module from REDZ:
Model NameModel Name DescriptionDescription Cable UsedCable Used
GLC-SX-MMD 1.25G, Dual Fiber, MM,
850nm, 550m, Industrial LC-LC MM Duplex
- 1.25 Gbit/s multi-mode fiber, LC connector, extraction lever colors not standardized
SX+/MX/LSX (name dependent on manufacturer) – 1310 nm, for a distance up to 2 km. Not compatible with SX or
100BASE-FX. Based on LX but engineered to work with a multi-mode fiber using a standard multi-mode patch cable
rather than a mode-conditioning cable commonly used to adapt LX to multi-mode.
- 1 to 2.5 Gbit/s single-mode fiber, LC connector, with blue extraction lever
LX – 1310 nm, for distances up to 10 km (originally, LX just covered 5 km and LX10 for 10 km followed later)
LH – 1310 nm, for a maximum of 20 km. Other multi-mode SFP applications support even higher rates at shorter
distances.
Model NameModel Name DescriptionDescription Cable UsedCable Used
GLC-LH-SMD 1.25G, Dual Fiber, 1310nm,
10km, Industrial LC-LC SM Duplex
GLC-LH-SMD-20 1.25G, Dual Fiber, 1310nm,
20km, Industrial LC-LC SM Duplex
EX – 1310 nm, for distances up to 40 km
ZX – 1550 nm, for distances up to 80 km (depending on fiber path loss), with green extraction lever (see GLC-ZX-SM1)
EZX – 1550 nm, for distances up to 160 km (depending on fiber path loss)
BX (officially BX10) – 1490 nm/1310 nm, Single Fiber Bi-Directional Gigabit SFP Transceivers, paired as BX-U and BX-D
for uplink and downlink respectively, also for distances up to 10 km. Variations of bidirectional SFPs are also
manufactured which use 1550 nm in one direction, and higher transmit power versions with link length capabilities up to
80 km.
Available SFP module from REDZ:
Model NameModel Name DescriptionDescription Cable UsedCable Used
CE-GLC-BX-3U
1.25G Bidi SFP, 1310nm-
TX/1550nm-RX, 3km, SC or
LC Port, Industrial
LC-LC SM Simplex
CE-GLC-BX-3D
1.25G Bidi SFP, 1550nm-
TX/1310nm-RX, 3km, SC or LC
Port, Industrial
LC-LC SM Simplex
CE-GLC-BX-10U
1.25G Bidi SFP, 1550nm-
TX/1310nm-RX, 10km, LC or
SC Port, Industrial
LC-LC SM Simplex
CE-GLC-BX-10D
1.25G Bidi SFP, 1550nm-
TX/1310nm-RX, 10km, LC or
SC Port, Industrial
LC-LC SM Simplex
CE-GLC-BX-20U
1.25G Bidi SFP, 1310nm-
TX/1550nm-RX, 20km, LC or
SC Port, Industrial
LC-LC SM Simplex
CE-GLC-BX-20D
1.25G Bidi SFP, 1550nm-
TX/1310nm-RX, 20km, LC or
SC Port, Industrial
LC-LC SM Simplex
1.25G Bidi SFP, 1310nm-

CE-GLC-BX-40U TX/1550nm-RX, 40km, LC or
SC Port, Industrial
LC-LC SM Simplex
CE-GLC-BX-40D
1.25G Bidi SFP, 1550nm-
TX/1310nm-RX, 40km, LC or
SC Port, Industrial
LC-LC SM Simplex
1550 nm 40 km (XD), 80 km (ZX), 120 km (EX or EZX)
SFSW – single-fiber single-wavelength transceivers, for bi-directional traffic on a single fiber. Coupled with CWDM,
these double the traffic density of fiber links.
Coarse wavelength-division multiplexing (CWDM) and dense wavelength-division multiplexing (DWDM) transceivers at
various wavelengths achieving various maximum distances. CWDM and DWDM transceivers usually support link
distances of 40 km, 80 km and 120 km.
- 1 Gbit/s for copper twisted-pair cabling, 8P8C (RJ-45) connector
1000BASE-T – these modules incorporate significant interface circuitry for Physical Coding Sublayer recoding and can
be used only for gigabit Ethernet because of the specific line code. They are not compatible with (or rather: do not
have equivalents for) Fiber Channel. Unlike non-SFP, copper 1000BASE-T ports integrated into most routers and
switches, 1000BASE-T SFPs usually cannot operate at 100BASE-TX speeds.
Available SFP module from REDZ:
Model NameModel Name DescriptionDescription Cable UsedCable Used
CE-GLC-T 10/100/1000M Copper SFP, RJ45
Port, 100M, Industrial RJ45 Cable
8. Connection Diagrams8. Connection Diagrams
BSB Series Industrial Unmanaged Ethernet Switches connections vary based on with and without BPL (Broadband
Power Line ) Link versions.
8.1 Connection Diagram for BPL Versions8.1 Connection Diagram for BPL Versions

8.28.2 Connection Diagram for ETH VersionsConnection Diagram for ETH Versions
8.38.3 Connection Diagram for SFP Port VersionsConnection Diagram for SFP Port Versions

8.48.4 Connection Diagram for PoE+ VersionsConnection Diagram for PoE+ Versions
9. System Comparison Between CAT5 and BPL Links9. System Comparison Between CAT5 and BPL Links
CAT5 Based SystemCAT5 Based System BPL Link Based SystemBPL Link Based System
Media CAT5 Power Line
Bandwidth 100Mbps Up to 30Mbps
Re-Wire Yes No, Using existing Power Line
Span <100m <600m
Multiple Nodes N/A Up to 10 hops/1000 nodes
Encryption Yes, but difficult to configure Yes, Plug & Play
Installment Difficult Easy, simply user power line

Installment Cost High Low
Total Cost High Low
10. Ordering Information10. Ordering Information
BSB115:BSB115: Industrial Unmanaged Ethernet Switch, 5 x 10/100 T(x) ETH ports, 5- 48 (max. 60V) DC Power Input
BSB118: BSB118: Industrial Unmanaged Ethernet Switch, 8 x 10/100 T(x) ETH ports, 5- 48 (max. 60V) DC Power Input
BSB120:BSB120: Industrial Unmanaged Ethernet Switch, 8 x 10/100 T(x) ETH ports and 2 x SFP Uplink Ports, 5- 48 (max. 60V) DC
Power Input
BSB215:BSB215: Industrial Unmanaged Ethernet Switch, 5 x 10/100 T(x) ETH ports, 90 - 265V AC (100 – 370V DC), 47Hz to 63Hz
AC Power Input
BSB218:BSB218: Industrial Unmanaged Ethernet Switch, 8 x 10/100 T(x) ETH ports, 90 - 265V AC (100 – 370V DC), 47Hz to 63Hz
AC Power Input
BSB220:BSB220: Industrial Unmanaged Ethernet Switch, 8 x 10/100 T(x) ETH ports and 2 x SFP Uplink Ports, 90 - 265V AC (100 –
370V DC), 47Hz to 63Hz AC Power Input
BSB268:BSB268: Industrial Unmanaged PoE+ Ethernet Switch, 8 x 10/100 T(x) ETH ports and all Ports Support PoE+, 100 - 240V
AC (120 – 370V DC), 50Hz to 60Hz AC Wide Range Power Input, 90 Watt Power Supply combined for all ports
BSB612:BSB612: Industrial Unmanaged Ethernet Switch, 1 x 10/100 T(x) ETH ports + 1 x BPL (Broadband Power Line) Link, 3 Phase
AC Power Input, 110V–240V/50-60Hz
BSB615:BSB615: Industrial Unmanaged Ethernet Switch, 4 x 10/100 T(x) ETH ports + 1 x BPL (Broadband Power Line) Link, 3 Phase
AC Power Input, 110V–240V/50-60Hz
BSB618:BSB618: Industrial Unmanaged Ethernet Switch, 7 x 10/100 T(x) ETH ports + 1 x BPL (Broadband Power Line) Link, 3 Phase
AC Power Input, 110V–240V/50-60Hz
11. Product Selection11. Product Selection
Model
5-48V
(Max.60V)
DC Power
input
100
-
240V
AC
(120 –
370V
DC),
50Hz
to
60Hz
AC
Power
Input
3 Phase
AC Power
input,
110V–
240V/50-
60Hz AC
Power
Input
8 x
10/100
T(x)
ETH
Ports
7 x
10/100
T(x)
ETH
Ports
5 x
10/100
T(x)
ETH
Ports
4 x
10/100
T(x)
ETH
Ports
1 x
10/100
T(x)
ETH
Ports
BPL
(Broadband
Power Line)
Link
2 x SFP
Uplink Ports
PoE+, 90
Watt
Power
Supply
combined
for all ports
BSB115 X X
BSB118 X X
BSB120 X X X
BSB215 X X
BSB218 X X
BSB220 X X X X
BSB268 X X X
BSB612 X X X
BSB615 X X X
BSB618 X X X
Other manuals for BSB Series
1
This manual suits for next models
9
Table of contents
Other REDZ Switch manuals
Popular Switch manuals by other brands

HP
HP 6125XLG Configuration guide

D-Link
D-Link mydlink DCH-G022 user manual

Transition Networks
Transition Networks SM24DPa user guide

BT
BT Business Hub 3 Getting started and troubleshooting

Rose electronics
Rose electronics VISTA KVL quick start guide

Vivotek
Vivotek AW-FCT-050A-250 Quick installation guide