Remora CL Series User manual

CL-01/CL-02 Part List5678910231Saddle Clamp10mm HoleSaddle Fitting AdaptorGasketSADDLE CLAMP ASSEMBLYPipingHose123465
材 料工 艺日 期
EMAUX CL 系列投药器 英文说明书EMFE20010901A41 : 180g印尼蓝纸/2020.011CL-01CL-02CL-01ACL-02AREMORA CL Series Automatic Chlorine FeederKeep the manual for future referenceREMORA CL series automatic chlorine feeder is designed to be used side by side with your filtration system. The feeder is driven by the pressure difference between its outlet and inlet which pushes water through it. It uses slow-dissolve chlorine, bromine or active oxygen large or small tablets (or sticks) ONLY. You should NEVER use other type of chemical. CL-01 and CL-01A can hold up to 2kg of tablets while CL-02 and CL-02A can hold up to 4kg. Such capacity should be able to provide 1 to 2 weeks’ chlorination for large pools. The feeder has a dial type control valve to adjust the flow rate through itself, by regulating the valve setting and the amount of tablets placed in the feeder, the chlorine feed rate needed to maintain the proper chlorine level of your pool can be readily tuned. WARNING: READ CAREFULLY AND KEEP THE MANUAL FOR FUTURE REFERENCEThis feeder can ONLY be used with slow-dissolving Chlorine, Bromine or Active Oxygen tablets. Do NOT mix with other type of chlorine or chemical, otherwise it may cause explosion or fire.Great care must be taken while opening the feeder. Always switch off pump and close all available valves before opening. Do NOT inhale air from any chemical feeder or container. Always protect your eyes, skin and clothing from any chemical.Do NOT open a feeder while the pump is running.To prevent gas from building up in the feeder, make sure the pool return line valve is kept open-except when opening or servicing. Always read the labels warning information and closely follow chlorine manufacture's and or dealer's recommendation for proper conditioning and daily chlorine requirements for your particular pool.DIRECTIONS FOR USE1)2)Before starting up your chlorine feeder your pool/spa should be properly conditioned with a
chlorine level of 1.0 to 1.5ppm. Directions and instructions from dealer and chemical
manufacturer should be followed.The chlorine demand for pools and spas varies according to load, usage, temperature, sunlight
etc. Initially you should experiment to determine the proper amount of chlorine and the correct
valve setting required for our pool and filter time cycle. Taking a 90 cubic meter pool as a
reference, we suggest You place about 1.8kg slow dissolve tablets in your feeder and leave the dial valve setting at No.3.(Increase or reduce the chlorine amount basing on the pool size, for example, for 135 cubic meter pool add 50% more chlorine.) Check chlorine residual dailyPART LIST4
名 称版本编号规 格比 例颜 色产品负责人更改日期
更改内容零部件清单
版本制图/设计
D意 万 仕( 中山) 泳池 设 备 有 限 公 司
EMAUX ZhongShan)Swimming Pool Equipment Co., Ltd(审核批准EMFE20010901
ItemPart No.DescriptionQty189440312Air/ Water Release Valve with O-Ring2289440204Lid with Nut1302080008O-Ring for Lid1489440205CL-01A Feeder Body1489440206CL-02A Feeder Body1589440202Hose with O-Ring16894402011.5"Union with Nut2
4
ItemPart No.DescriptionQty189440312Air/ Water Release Valve with O-Ring2289440204Lid with Nut1302080008O-Ring for Lid1489440205CL-01A Feeder Body1489440206CL-02A Feeder Body1589440202Hose with O-Ring1689440203Threaded Plug2789440208Hose Connector28010930172.5m Hose (O.DΦ10)1989440207Saddle Fitting Adaptor21003018153 Hose Clamp2
CL-01A/CL-02A Part ListPANTONE Process Black CAUTOMATED ENVIRONMENTAL SYSTEMS
Unit 1, 1 Wimbledon Avenue, Brandon,
Suffolk, IP27 0NZ
01842 819130

and adjust the dial valve for more or less chlorine. Increasing the quantity of chlorine in your feeder with extend the recharging circle.OPENING THE FEEDER LID1)Turn off pump and turn Dial Control Valve to “O”. Shut off inline valve(s) if any to preventbackflow. Unscrew Venting Screw at the top of the Lid. Wait for 1 minute to ensure the release ofpressure.2) Turn the Nut of the Lid anti-clockwise to disassemble the Lid.CLOSING THE FEEDER LID1) Align the Nut of the Lid to the threads of the Feeder. Engage the Nut threads by turning clockwiseto tighten.2) Tighten the Venting Screw.3) Set the Dial Control Valve to the desired position then open the inline valve(s) if available.4) Turn on pump.VACUUMINGClose Dial Control Valve to avoid bypass of sediment and possible clogging of control valve when vacuuming.CHANGING O-RINGS1) Follow the steps under “OPENING THE FEEDER LID”2) Before replacing the o-ring, make sure all liquid has beendischarged by removing the Feeder's bottom drain plug with ascrewdriver.3) Turn the Lid upside down and the o-ring can be found.4)Insert a flat head screwdriver into the groove as indicated. Usingthe screwdriver at an angle lift the o-ring.5)Once the o-ring had been replaced. Follow the steps under“CLOSING THE FEEDER LID”.6)Turn the Dial Control Valve to maximum setting and continue toturn anti-clockwise until the dail control click twice. The DrainControl Valve can then be removed from the feeder.7) Replace the two o-rings.8) Once the o-rings had been replaced, insert the Dial Control Valveback into the feeder. Turn clockwise until the Dail Control clicktwice. It is important to ensure the Dail Control passes the secondclick.9)Select the desire position then open inline valve and restart thepump.WARNING: DO NOT use petroleum type of lubricants on the O-ring. Silicone Grease is recommended.INSTALLATIONHARD PIPE (CL-01 / CL-02) Always install the chlorine Feeder after the heater. If there is no heater, install after the filter.Position the Chlorine Feeder on level surface as close to the filter and pump as possible. The preferred installation is above water level and using Inline Setup (Figure 1). The feeder needs to be below the filter or the heater (if available) as indicated in Figure 1. At the inlet pipe to the feeder, a positive seal corrosion-resistant check valve should be installed to reduce backflow of chlorine gas when the system is turned off. It is recommended that if the feeder is installed below the waterline, a check valve is needed to prevent water backflow when opening the unit.FLEXIBLE HOSE (CL-01A / CL-02A)The Stainless Steel Saddle Clamps for the Flexible Hose installation are designed for pipes with diameter of 1.5' or 2.0'.Inlet1) Along the pipe between the pump and the filter as shown in Figure 2, make a hole of 10mm in diameter as the inlet for the feeder.2) Clean off burrs and shavings, insert the Saddle Fitting Adaptor with Gasket into the drilled hole. Place the Saddle Clamp on to the pipe as indicated. Connect the hose.Outlet3) Along the pipe after the filter and heater as shown in figure 2 , drill a hole of 10mm in diameter as the outlet for the feeder.4) Clean off burrs and shavings, insert the Saddle Fitting Adaptor with Gasket into the drilled hole. Place the Saddle Clamp on to the pipe as indicated. Connect the hose.5) Connect the inlet and outlet tubing with the Adaptor into the Feeders’ Threaded Plug.Note: After installation start up the system to perform leakage check, re-tighten if required. The feeder can be fixed onto the installation surface by tapping screws and securing holes in its base.INLET OUTLETSaddle Clamp10mm HoleSaddle Fitting AdaptorGasketPipingHoseO-Ring for LIDTurn the dial control anti-clokwiseO-Ring for Dial ControlDrain plugScrewdriver32Figure 1Figure 2

and adjust the dial valve for more or less chlorine. Increasing the quantity of chlorine in your feeder with extend the recharging circle.OPENING THE FEEDER LID1)Turn off pump and turn Dial Control Valve to “O”. Shut off inline valve(s) if any to preventbackflow. Unscrew Venting Screw at the top of the Lid. Wait for 1 minute to ensure the release ofpressure.2) Turn the Nut of the Lid anti-clockwise to disassemble the Lid.CLOSING THE FEEDER LID1) Align the Nut of the Lid to the threads of the Feeder. Engage the Nut threads by turning clockwiseto tighten.2) Tighten the Venting Screw.3) Set the Dial Control Valve to the desired position then open the inline valve(s) if available.4) Turn on pump.VACUUMINGClose Dial Control Valve to avoid bypass of sediment and possible clogging of control valve when vacuuming.CHANGING O-RINGS1) Follow the steps under “OPENING THE FEEDER LID”2) Before replacing the o-ring, make sure all liquid has beendischarged by removing the Feeder's bottom drain plug with ascrewdriver.3) Turn the Lid upside down and the o-ring can be found.4)Insert a flat head screwdriver into the groove as indicated. Usingthe screwdriver at an angle lift the o-ring.5)Once the o-ring had been replaced. Follow the steps under“CLOSING THE FEEDER LID”.6)Turn the Dial Control Valve to maximum setting and continue toturn anti-clockwise until the dail control click twice. The DrainControl Valve can then be removed from the feeder.7) Replace the two o-rings.8) Once the o-rings had been replaced, insert the Dial Control Valveback into the feeder. Turn clockwise until the Dail Control clicktwice. It is important to ensure the Dail Control passes the secondclick.9)Select the desire position then open inline valve and restart thepump.WARNING: DO NOT use petroleum type of lubricants on the O-ring. Silicone Grease is recommended.INSTALLATIONHARD PIPE (CL-01 / CL-02) Always install the chlorine Feeder after the heater. If there is no heater, install after the filter.Position the Chlorine Feeder on level surface as close to the filter and pump as possible. The preferred installation is above water level and using Inline Setup (Figure 1). The feeder needs to be below the filter or the heater (if available) as indicated in Figure 1. At the inlet pipe to the feeder, a positive seal corrosion-resistant check valve should be installed to reduce backflow of chlorine gas when the system is turned off. It is recommended that if the feeder is installed below the waterline, a check valve is needed to prevent water backflow when opening the unit.FLEXIBLE HOSE (CL-01A / CL-02A)The Stainless Steel Saddle Clamps for the Flexible Hose installation are designed for pipes with diameter of 1.5' or 2.0'.Inlet1) Along the pipe between the pump and the filter as shown in Figure 2, make a hole of 10mm in diameter as the inlet for the feeder.2) Clean off burrs and shavings, insert the Saddle Fitting Adaptor with Gasket into the drilled hole. Place the Saddle Clamp on to the pipe as indicated. Connect the hose.Outlet3) Along the pipe after the filter and heater as shown in figure 2 , drill a hole of 10mm in diameter as the outlet for the feeder.4) Clean off burrs and shavings, insert the Saddle Fitting Adaptor with Gasket into the drilled hole. Place the Saddle Clamp on to the pipe as indicated. Connect the hose.5) Connect the inlet and outlet tubing with the Adaptor into the Feeders’ Threaded Plug.Note: After installation start up the system to perform leakage check, re-tighten if required. The feeder can be fixed onto the installation surface by tapping screws and securing holes in its base.INLET OUTLETSaddle Clamp10mm HoleSaddle Fitting AdaptorGasketPipingHoseO-Ring for LIDTurn the dial control anti-clokwiseO-Ring for Dial ControlDrain plugScrewdriver32Figure 1Figure 2

CL-01/CL-02 Part List5678910231Saddle Clamp10mm HoleSaddle Fitting AdaptorGasketSADDLE CLAMP ASSEMBLYPipingHose123465
材 料工 艺日 期
EMAUX CL 系列投药器 英文说明书EMFE20010901A41 : 180g印尼蓝纸/2020.011CL-01CL-02CL-01ACL-02AREMORA CL Series Automatic Chlorine FeederKeep the manual for future referenceREMORA CL series automatic chlorine feeder is designed to be used side by side with your filtration system. The feeder is driven by the pressure difference between its outlet and inlet which pushes water through it. It uses slow-dissolve chlorine, bromine or active oxygen large or small tablets (or sticks) ONLY. You should NEVER use other type of chemical. CL-01 and CL-01A can hold up to 2kg of tablets while CL-02 and CL-02A can hold up to 4kg. Such capacity should be able to provide 1 to 2 weeks’ chlorination for large pools. The feeder has a dial type control valve to adjust the flow rate through itself, by regulating the valve setting and the amount of tablets placed in the feeder, the chlorine feed rate needed to maintain the proper chlorine level of your pool can be readily tuned. WARNING: READ CAREFULLY AND KEEP THE MANUAL FOR FUTURE REFERENCEThis feeder can ONLY be used with slow-dissolving Chlorine, Bromine or Active Oxygen tablets. Do NOT mix with other type of chlorine or chemical, otherwise it may cause explosion or fire.Great care must be taken while opening the feeder. Always switch off pump and close all available valves before opening. Do NOT inhale air from any chemical feeder or container. Always protect your eyes, skin and clothing from any chemical.Do NOT open a feeder while the pump is running.To prevent gas from building up in the feeder, make sure the pool return line valve is kept open-except when opening or servicing. Always read the labels warning information and closely follow chlorine manufacture's and or dealer's recommendation for proper conditioning and daily chlorine requirements for your particular pool.DIRECTIONS FOR USE1)2)Before starting up your chlorine feeder your pool/spa should be properly conditioned with a
chlorine level of 1.0 to 1.5ppm. Directions and instructions from dealer and chemical
manufacturer should be followed.The chlorine demand for pools and spas varies according to load, usage, temperature, sunlight
etc. Initially you should experiment to determine the proper amount of chlorine and the correct
valve setting required for our pool and filter time cycle. Taking a 90 cubic meter pool as a
reference, we suggest You place about 1.8kg slow dissolve tablets in your feeder and leave the dial valve setting at No.3.(Increase or reduce the chlorine amount basing on the pool size, for example, for 135 cubic meter pool add 50% more chlorine.) Check chlorine residual dailyPART LIST4
名 称版本编号规 格比 例颜 色产品负责人更改日期
更改内容零部件清单
版本制图/设计
D意 万 仕( 中山) 泳池 设 备 有 限 公 司
EMAUX ZhongShan)Swimming Pool Equipment Co., Ltd(审核批准EMFE20010901
Item
Part No.
Description
Qty
1
89440312
Air/ Water Release Valve with O-Ring
2
2
89440204
Lid with Nut
1
3
02080008
O-Ring for Lid
1
4
89440205
CL-01A Feeder Body
1
4
89440206
CL-02A Feeder Body
1
5
89440202
Hose with O-Ring
1
6
89440201
1.5"Union with Nut
2
4
Item
Part No.
Description
Qty
1
89440312
Air/ Water Release Valve with O-Ring
2
2
89440204
Lid with Nut
1
3
02080008
O-Ring for Lid
1
4
89440205
CL-01A Feeder Body
1
4
89440206
CL-02A Feeder Body
1
5
89440202
Hose with O-Ring
1
6
89440203
Threaded Plug
2
7
89440208
Hose Connector
2
8
01093017
2.5m Hose (O.DΦ10)
1
9
89440207
Saddle Fitting Adaptor
2
10
03018153
Hose Clamp
2
CL-01A/CL-02A Part ListPANTONE Process Black CAUTOMATED ENVIRONMENTAL SYSTEMS LTD
Unit 1, 1 Wimbledon Avenue, Brandon,
Suffolk, IP27 0NZ
01842 819130
This manual suits for next models
4
Table of contents
Other Remora Marine Equipment manuals
Popular Marine Equipment manuals by other brands

Deif
Deif AGC 150 Operator's manual

Teknim
Teknim TFS-1192R installation manual

R.M. Young
R.M. Young 06206 instructions

Wet Sounds
Wet Sounds WS-MC-20 owner's manual

Seastar Solutions
Seastar Solutions Hynautic 04 Series Installation instructions and owner's manual

KVH Industries
KVH Industries TracPhone V7-HTS installation guide