Operating Manual Crimp system tool PEW 12
Rev.: 2011-07-22 6 / 6
7. Guarantee
The crimp system tool is subjected to a thorough quality control process.
General warranty conditions apply.
8. Service and maintenance
Before starting work, ensure that the crimp system tool is clean and in proper working order.
Crimping residue must be removed. Joints should be regularly oiled with a light mineral oil
and protected against contamination. It must be ensured that all bolts are secured by means
of securing rings. Check that the setting dial is secured tightly by the slotted headless screw.
Maintenance of the crimper should be performed by the manufacturer.
1. Using a screwdriver, remove the slotted headless screw.
2. If the setting dial (2) is rotated counter-clockwise (+), this
configures a stronger crimp force and a smaller crimp height.
3. If the setting dial is rotated clockwise (-), this configures a weaker
crimp force and thus a greater crimp height. Regulation of the
hand force should not exceed 180 N.
4. If bolt aperture 3is used, it becomes possible to alter the
crimp force by only half a notch. This enables very fine-grained
adjustments to be made to the crimp force.
5. Replace the slotted headless screw
6. Prior to using the crimper, it must be ensured that the adjusting
disc is properly secured with the slotted headless screw.
1
2
The crimp height should be checked regularly by qualified personnel
from quality control and recalibrated as required using the method
described below.
Attention
3