Rentokil Lumnia Suspended US User manual

Lumnia Suspended US - Instruction Manual
This manual is based on the latest information and is provided subject to alteration.
We reserve the right to change the construction and/or confi guration of the product
and versions at any time without obligation.
All rights reserved. No part of this document may be reproduced, stored in a database or any other retrieval
system, or published, in any form or way, electronically, mechanically, digitally per photo print or microfi lm or
any other way without written permission from the author.
Compatible with Lumnia+ Encapsulation Module

IMPORTANT SAFETY INSTRUCTIONS
WARNING - When using electric appliances, basic
precautions should always be followed, including the following:
a. Read all the instructions before using the appliance.
b. To reduce the risk of injury, close supervision is necessary when
an appliance is used near children.
c. Do not contact moving parts.
d. Only use attachments recommended or sold by the
manufacturer.
e. Do not use outdoors.
f. To disconnect the appliance:
− Do not unplug by pulling on cord. To unplug, grasp the plug,
not the cord.
− Unplug from outlet when not in use and before servicing or
cleaning.
− Do not operate any appliance with a damaged cord or
plug, or after the appliance malfunctions or is dropped or
damaged in any manner. Return appliance to the nearest
authorized service facility for examination, repair, or
electrical or mechanical adjustment.
g. Always unplug before replacing the lamp. Replace lamp with the
same type UV-LED Lamp: 304816
h. This appliance is provided with double insulation. Use only
identical replacement parts. See instructions for Servicing of
Double-Insulated Appliances.
CAUTION - Risk of UV exposure. Ensure the product is installed
such that no continous human activity is likely to be performed
within 3’3” (1M) distance of the unit while illuminated.
SAVE THESE INSTRUCTIONS
1. Safety

The lamps in this unit produce ultraviolet (UV) light, which can
cause skin or eye damage if viewed directly for a long period.
Only fit the correct type of UV lamps in the unit.
The unit shall be installed and serviced by individuals with
appropriate qualifications and/or experience in accordance
with national regulations in the country of operation and
installation.
Disconnection from the mains is provided by means of a
supply cord fitted by a plug. Protect the mains cable from
damage. If the mains cable is damaged, do not use the unit.
The cable must be replaced by the manufacturer, its service
agent, or similar qualified persons.
Do not insert foreign objects into the unit.
Do not use an extension cable with this unit.
Only personnel with appropriate skills and training must install
or service this unit.
Do not install this unit in areas where dangerous
concentrations of inflammable or explosive substances may
be present in the air.
Only install this product indoors in a dry location that is
shielded from direct sunlight. Do not install the unit in a barn,
stable, or similar location.
Install the cable such a way to prevent the exposition of the
cable to UV radiation from UV Lamps
Children or personnel with reduced physical, sensory or
mental capabilities, or personnel who lack experience or
knowledge, must not use this unit, unless they are supervised
by a person responsible for their safety.Children must not
play with this unit. The appliance is to be kept out of reach
of children. Do not place or fit directly above food handling,
preparation or manufacturing areas. Do not place or fit directly
above food handling, preparation or manufacturing areas.
Users can perform the maintenance tasks described in this
document. Users must not perform any other repairs or
maintenance.
Warning
Caution
Attention
WARNING Skin or eye damage
may result from directly viewing
the light produced by the lamp in
this apparatus. To safeguard always
ensure installation manual and
manufacturers recommendations
are followed.
CAUTION Risk of UV exposure. Ensure product
is installed to ensure no person is likely to be
within 3’3” feet of the unit while illuminated.
AVERTISSEMENT Observer la lumière produite
par la lampe de cet appareil sans protection peut
causer des dommages cutanés ou oculaires.
Pour des raisons de sécurité, veillez au respect
des consignes du manuel d’installation et des
recommandations du fabricant.
ATTENTION Risque d’exposition UV. Veillez à ce
que le produit soit installé de manière à ce que
personne ne se trouve à moins de 3’3” feet de
celui-ci tandis qu’il est allumé.
1. Safety
SAVE THESE INSTRUCTIONS

2. Introduction
The Lumnia Suspended unit uses three ultra-violet LED driven lamps that attract flying
insects that are then captured on a replaceable glue board or encapsulation module. The
modular design of this unit allows for both. The Suspended product comes as a glue board
monitoring device which can be upgraded to a control device by adding the Lumnia +
encapsulation module.
While unpacking, check for any signs of shipment damage and, if found, notify both
transporter and supplier in writing within eight days of receipt with full details of the
damage that has occurred. Retain the equipment and packing materials for inspection.
Check that all parts have been received as ordered. Make sure that all packaging is
removed from the unit before use.
3. Equipment for Installation
In the Box:
AEquipment Required for Install
B
1. Lumnia Suspended Unit TBC
Also includes x3 UV-LED Lamps 304816
2. Quick Start Guide
3. Glue Board (Black)
4. Internal Packaging
5. Outer box and Label
6. Non Woven Bag
7. Power Grommet
8. Instruction Manual
Please refer to local country guidance.
1
2
3
4
5
4
6
4
7
8

DANGER: SERVICING OF DOUBLE-INSULATED APPLIANCES
In a double-insulated appliance, two systems of insulation are provided instead of grounding. No
grounding means is provided on a double-insulated appliance, nor should a means for grounding
be added to the appliance. Servicing of a double-insulated appliance requires extreme care and
knowledge of the system and should be done only by a qualifi ed service personnel. Replacement
parts for a double insulated appliance must be identical to those parts in the appliance. A double-
insulated appliance is marked with the words “DOUBLE INSULATION” or “DOUBLE INSULATED”.
The symbol (square within a square) may also be marked on the appliance.
Operational Service Mode
Mode Icon
4. Connecting the Power Source
1. Isolate the electrical supply to the power socket.
2. Check that the mains voltage displayed on the unit label
is correct for your supply.
3. Check that the cable and plug connector are not
damaged.
Once installed as above and mounted correctly, connect the plug connector for the
cable into the power socket.
When operational, the Mode Icon on the underside switch will illuminate blue. If the
product is in Service Mode the Mode Icon will illuminate red.
Cable Assembly not supplied in box. Ordered direct from
Rentokil Initial to meet specifi c country requirements.
NOTE:
WARNING: You must NOT connect the unit into a lighting circuit.
You must connect the power cable to a standard power socket.

Suspend the unit from a suitable structure at a minimum
height of 6’6” (2m) to the bottom of the unit. Figure 1
illustrates the suggested mounting height.
Position the unit as far as possible from sources of
ambient light. Ambient light can cause ine cient
capture of fl ying insects.
Ideally position the unit so the cable entry is within 5’
(1.5m) of an electric socket. If this is not possible the unit
must be connected safely by a qualifi ed electrician.
5. Installing the Unit
Figure 1:
To ensure that the product minimises risk UV exposure especially to eyes, it is
recommended that the product is installed at a minimum height of 6’6” (2m) from
the bottom of the unit and also at least 3’3” (1m) from any area that may have people
occupying for more than 4 hours in a day.
Due to the recommended installation height, please ensure that you work safely
according to your country’s guidelines.
3’3” (1 m)
min. 6’6” (2 m)
6’6” (2 m)
NOTE: Before you begin, please contact your Regional Technical Manager for
advice on appropriate fi xing and hanging methods.
WARNING: When positioning the unit, ensure the hanging height is su cient
to clear any equipment below and can be serviced safety.
For safety reasons, the unit contains a interrupt switch on the underside of the unit, which
disables the UV lamps if you wish to enter service mode. See Section 4.
3’3” (1 m)
6’6” (2 m)

Warehouses,
Home,
Theatres,
Archives
Normal Oce
Work, PC Work,
Study Library,
Show Rooms,
Laboratories
Supermarkets,
Areas near
windows
Changing
environments.
Lights o or low
light situations
6. Positioning Guide
Figure 2:
DO NOT position the unit directly over areas where food is handled, prepared,
manufactured or where uncovered food is stored.
DO NOT position unit directly over sources of heat.
See Figure 2 below for dimensions to consider when positioning the unit.
• Not facing entry/exit point or windows - to avoid attracting unwanted insects or
competing light sources
• Avoid installing close to a competing light source
• Maximise line of sight (i.e. Have clear line of sight from any point in coverage area
away from food source or high risk area)
Lumnia Performance Table
Reference to setting power modes Section 11.
Power Setting Low ( I ) Medium ( II ) High ( III ) Adaptive (A B C
)
Ambient Light
Level (LUX)
Equivalent
Environment
< 300 300 - 750 750 + 100
21.7” (551 mm)
15.7”
(399mm)
11”
(280mm)

Flex Remove Liner
7. Preparing the Glue Board
9. Removing the Glue Board
8. Installing the Glue Board

REMOVING UV LED LAMPS
10. Removing and Replacing the
UV - LED Lamps
REPLACING UV LED LAMPS
NOTE: Please ensure device is in Service Mode before servicing. See Section 4.
NOTE: Do not touch LED when
servicing, maintaining or cleaning the
lamps.
NOTE: Ensure the lamp is pushed fi rmly back into the left hand fi tting.

90 18030
A B C
90 18030
A B C
A
A
A
90 18030
A B C
B
90 18030
A B C
C
C
90 18030
A B C
90 18030
A B C
90 18030
A B C
II = Med III = HighI = Low
A = Adaptive Low* B = Adaptive Med* C = Adaptive High*
11. User Interface Settings
Mode Button
90
180
30
30
Functions for use with Lumnia+ ONLY:
See Section 15 for Lumnia+ User Interface
The Adaptive light setting reduces the light output when light levels are below
100Lux.
For power consumption savings, the Adaptive light setting reduces the light output
at low ambient light levels. The Low, Medium and High denotes the settings
indicated in normal mode (as above, I, II or III)
* Adaptive Mode:

Roll included
in Box
Glue Roll
Assembly
Drive
Retain the tape to fi x to drive spool
12. Lumnia+ Encapsulation Module
13. Setting up Lumnia+ Encapsulation
Your Lumnia Suspended can be turned from a monitoring device to a control device
in areas where fl y infestations may occur. A motorised Encapsulation Module can be
purchased to use with your Lumnia.

14. Encapsulation Unit Install Preparation
15. Loading Lumnia+ Encapsulation

The interface is activated when the Lumnia+ Encapsulation Module is inserted.
90 18030
A B C
Release
Click
Click
Glue Roll Manual Override
Glue Roll Service Day Setting
30 day setting rolls on a clean
glue surface every 24 hours
Mode Button
See Section 11 for Mode Setting User Interface
Lumnia+ User Interface
NOTE:
Glue Roll settings only apply
and function when a Lumnia+
Encapsulation Module is fi tted.
Warning: Ensure the encapsulation unit clicks into the bracket as above.

RED:
FAULT
GREEN:
OPERATIONAL
See Section 15 for fi tting the Lumnia+ Module
17. Unloading Lumnia+ Encapsulation
NOTE:
Counter for Lumnia+ Encapsulation Module resets when removed from Lumnia.
Important that module is removed for a new Glue Roll.
16. Glue Roll Operation

Part
C
Part
A
With
emboss
New Roll
Without
emboss
Part
C
Part
B
Part
A
Part
B
Part
DPart
E
Reuse parts A - E above to create
the new Roll Assemblies below
Part
D
Part
E
18. Servicing: Replacing the Glue Roll

NOTES

NOTES

19. Accessories and Spares
For a list of the Lumnia accessories and spares see below:
Spares:
• UV - LED Lamp: 304816
• Lumnia+ Encapsulation Module: 304773
• Glue Board (Pack of 10 Black): 305069
• Glue Roll (Box of 12) : 304780
• Lumnia Power Lead (UK Connection): 304781
• Lumnia Power Lead (EU Connection): 304782
• Lumnia Power Lead (EU Contour Connection): 304803
• Lumnia Power Lead (SA Connection): 304784
• Lumnia Power Lead (JP Connection): 304785
• Lumnia Power Lead (US Connection): 304786
• Lumnia Power Lead (CN & AU Connection): 304783
20. Product Disposal
The Lumnia Suspended is classified as electrical or electronic
equipment, according to the Waste of Electrical and
Electronic Equipment (WEEE) directive. Do not dispose of this
product with other household or commercial waste. Contact
the agent who sold the product for recycling advice.
The product described in this manual is subject to continuous
development and improvement and Rentokil reserve the
right to alter the specification or design without prior notice.
Rentokil cannot accept any liability for any loss or damage
arising from the use of any information contained within this
manual, or from any incorrect use of the product described
herein. Rentokil can accept no liability whatsoever for any
loss or damage arising from the product being serviced
maintained or repaired by unauthorised personnel.

Power supply 100 to 240V AC
Power classification Class II
Power consumption 30W
Ingress Protection Rating IP65
Replacement tubes Rentokil type SKU: 304816
Size W= 21’7” (551mm), H= 11’0” (280mm),
D= 15’7” (399 mm)
Weight:
• Boxed Unit 18.0 Ibs (8.2kg) - (boxed)
• Unit including Lamps 11.6 Ibs (5.25kg)
& Glueboard
• Lumnia+ Encapsulation 3.0 Ibs (1.35kg) - (unit)
Module
Lumnia+ Encapsulation Module 24V DC
21. Specification
Parameter Value
Refer to Lumnia Suspended Manual
for full installation instructions,
scan the QR code or visit:
www.rentokil.com/manuals

© 2017 RENTOKIL INITIAL PLC ALL RIGHTS RESERVED
2017 Rentokil Initial plc. Registered in England 5393279.
Registered oce: Riverbank, Meadows Business Park,
Blackwater, Camberley, Surrey, GU17 9AB
The names Rentokil® and Initial® are registered trademarks
Why Choose Rentokil?
Rentokil is the global leader in pest control, bringing expert, reliable and
professional service to commericial and residential customers in over 60 countries
worldwide. As the experts in pest control, we work closely with you to:
Give you peace of mind.
With over 12,000 qualified technicians worldwide, we have extensive experience
across a wide range of industry sectors. Our experts work proactively in
partnership with you to minimise the threat of pest infestations in your business.
Safeguard your reputation
We take a dual approach, incorporating both preventative and responsive
strategies to enhance protection for your business through a consistent,
continuous pest control programme.
Neither the whole nor any part of the information described in this manual, nor the
product therein described, may be adapted or reproduced in any form without prior
written approval of Rentokil.
The product described in this manual is subject to continuous development and
improvement and Rentokil reserve the right to alter the specification or design
without prior notice. Rentokil cannot accept any liability for any loss or damage arising
from the use of any information contained within this manual, or from any incorrect
use of the product described herein. Rentokil can accept no liability whatsoever for
any loss or damage arising from the product being serviced maintained or repaired
by unauthorised personnel.
For more information about Rentokil visit www.rentokil.com
Registered Design - refer to www.rentokil-initial.com/ip
GSD-160156-1.0 US
This manual suits for next models
1
Table of contents
Other Rentokil Insect Control Equipment manuals
Popular Insect Control Equipment manuals by other brands

Kasanova
Kasanova HOH000006 7 instruction manual

Emil Lux
Emil Lux 306232 Original instructions

Coleman
Coleman Mosquito Deleto 2200 Instructions for use

Pelsis
Pelsis Synergetic Halo 15W manual

Paraclipse
Paraclipse Mosquito Eliminator Maintenance instructions

Eastern Tabletop
Eastern Tabletop Go Clean Germbuster manual