1
Technical Safety Information for the User
This description contains the necessary information for the correct application of the product described
below. It is intended for use by technically qualified personal.
Qualified personnel are persons who, because of their training, experience and position as well as their
knowledge of appropriate standards, regulations, health and safety requirements and working conditions,
are authorised to be responsible for the safety of the equipment, at all times, whilst carrying out their
normal duties and are therefore aware of, and can report, possible hazards (Definition of qualified
employees according to IEC 364)
Safety Instructions
The following instructions are provided for the personal safety of operatorsandalso forthe protection of
the described product and connected equipment.
Warning!
Hazardous Voltage
Failure to observe can kill, cause serious injury or damage
•Isolate from mains before installation or dismantling work, as well as for fuse changes or post
installation modifications.
•Observe the prescribed accident prevention and safety rules for the specific application.
•Before putting into operation check if the rated voltage for the unit conforms with the local supply
voltage.
•Emergency stop devices must be provided for all applications. Operation of the emergency stop must
inhibit any further uncontrolled operation.
•Electrical connections must be covered
•The earth connection must be checked, for correct function, after installation.
•After switching off the unit, some internal components will still be charged due to capacitance.
•Before opening the unit wait at least five minutes to allow capacitors to discharge.
Specified Use
The units described herein are electrical controllers for installation in industrial plant.
They are designed for power adjustment on vibratory feed equipment.
The units conform to the directive 89/336/EWG EMC-Directive
Contents
Technical Safety Information for the User............................................................................................1
1.0Description...................................................................................................................................2
2.0Function.......................................................................................................................................2
3.0 Technical Data...............................................................................................................................2
4.0 Declaration of Conformity..............................................................................................................2
5.0Connections .................................................................................................................................3
6.0Dimensions..................................................................................................................................3
7.0 Ordering Codes............................................................................................................................3
!

Operating Instructions REOVIB 51310
2
1.0 Description
Track control units for regulating the material reservoir on a feed track. Nearly all propriety initiators,
active light barriers or Namur transducers can be installed. The switching characteristics (PNP / NPN–
output) can be adjusted on a front panel selector.
2.0 Function
The material demand is controlled by a sensor, the signal of which passes through two, independent,
variable time delays (on and off switching delays), before enabling the output, which, for example,
actuates the thyristor control.
If the sensor is uncovered (No reservoir build up) and the adjustable switch on time delay has expired, the
513 enables the power output of a thyristor controller. When the components cover the sensor, the switch
off time delay starts and after this expires, the power output of the thyristor control is switched off. Gaps in
the material flow are subject to control by the integral timers, so that there is consistent timing between
the last component and the first component.
The on and off switching time delays can be adjusted with trimmers on the front panel of the unit, within
the range of 0.5–15 seconds. The status ofthe sensors (energised/de-energised) and also the enable
output (on/off) is indicated on LED’s.
A relay switches changeover contacts, in addition to the enable output, and this is brought out to
terminals. These contacts can be used to initiate other processes or supervisory equipment.
3.0 Technical Data
Gerätetype
Supply Voltage 230 V +6% -15%, 50/60 Hz (110V Optional)
Sensor operating Voltage approx. 24 V, DC
Sensor types Inductive, Capacitive, Namur, Active Light Barriers
Switching Characteristics PNP, NPN switchable
Sensor Current 100 mA
Switch on delay 0.5 –15 secs
Switch of time delay 0.5 –15 secs
Anbient temperature 0 –45 °C
Dimensions (l x w x h) 80 x 45 x 114
Relay contact 2 A / 250 V
Screw or Snap fixing (DIN rail EN 50022-35)
Touch protection to VBG 4
4.0 Declaration of Conformity
We declare that these products, as stand-alone equipment, conform to the following standards
or subsequent documents: EN 50081-2 and EN 50082-2 in accordance with 89/336/EWG
regulations.
REO ELEKTRONIK GMBH, D-42657 Solingen

Operating Instructions REOVIB 51310
3
5.0 Connections
6.0 Dimensions
7.0 Ordering Codes
Tpye ID.No.:
REOVIB 513 / 230V 51310
REOVIB 513 /115V 51312
1
Taus
Tein
513
2 3 4 5
8910
45
74
100
125
ELEKTRONIK
6 7
NA
Sensor
Ausgang
11
change-over PNP/PNP bzw, NPN/NPN
PNP/PNP
1 2
S1
1 2
1 2
LPE
230V
+6% -10%
Namur Sensor
Sensor
aktively switching
PNP/NPN
Feeder
on / off
to the thyristorcontroler
time on delay
time off delay
setpoint
Namursensor
Sensor switch
PNP - output
NPN - output
Namur
LED
Sensorcontrol
LED
output
2
1 3
Interner
Wechsler
Potentialfrei
1
Toff
Ton
513
23 4 5
8910
ELEKTRONIK
6 7
NA
Sensor
Output
11
N
NPN/NPN
Thyristorcontroler on
Sensor
Output
t on t off
switch S1
-E+ + -