Reviber ER12 User manual

HOT AND COLD MASSAGER
Zen Lifesles UK Ltd
Address:
Tel:
Email:
CONTACT US
Unit 9, Oasis Business Park, Road One,
Winsford Industrial Estate, Cheshire,
CW7 3RY, UK
01606 352277
sales@reviber.co.uk
SPECIFICATIONS
When using the product, all instructions and basic
precautions should always be followed, including:
This marking indicates that this product should not be
disposed of with other household waste at the end of
their working life. To prevent possible harm to the
environment or human health from uncontrolled waste
disposal please recycle it responsibly to promote the
sustainable reuse of material resources. Alternatively
use return and collection systems or contact the
retailer where the product was purchased from and
they can take the product for enviromental safe
recycling.
WWW.REVIBER.CO.UK
REVIBER COMMUNITY
JOIN THE REVIBER COMMUNITY to access the latest advice
and exercises for your product. Ask and answer questions about
the products, share your progress and engage with other
like-minded users of the REVIBER collection of health and fitness
products.
You can also contact our support team and service department
for lost or missing parts, accessories and manuals.
Model Number
Power Consumption
N.W.
G.W.
Voltage
Size(mm)
ER12
30W
1.2KG
12V DC
W370xL170xH170
2.2KG
Name Reviber Hot & Cold Massager
Material ABS
Rated time 15 minutes
IMPORTANT SAFETY INSTRUCTIONS
CORRECT DISPOSAL OF THE PRODUCT
- Read the manual fully before using the machine.
- Do not use with wet hands or in a damp
environment.
- Do not use on your head or your face.
- Do not cross over the spine with the massage
heads.
- Do not use the machine immediately aer eating.
- Should a problem occur, turn the power o,
unplug the machine and contact your supplier.
Not to be used by children, if you have recently
had surgery or broken bones or a pacemaker
fied.
Not to be used during pregnancy (definitely not on
the abdomen area and you should take advice
from your doctor if it is safe to use elsewhere on
the body).
Not to be used by cancer patients that are
receiving chemotherapy or radiotherapy treat-
ment.
Not to be used if you have haemophilia.
Avoid massaging areas with localised skin infec-
tions, deep bruising or varicose veins.
If you suer with thrombosis or are susceptible to
it, then you should always consult your doctor or
physician before using the machine, as you should
it you have a health condition not listed above.
CLEANING AND MAINTENANCE
Before cleaning, please make sure that the switch
is in the o position, and the power plug has been
pulled out from the socket. Please use a dry cloth
to clean the product.
Please make sure that you do not use benzene
or thinner, and other aggressive detergents to
clean product, otherwise the product colour
may fade.
CLEANING
ATTENTION

WHEN TO TREAT WITH HEAT
Heat treatment (or thermotherapy) relieves
stiness and chronic aches, facilitates relaxation,
and stimulates circulation. It works by increasing
tissue temperatures and blood flow, thereby
drawing extra nutrients into the area to assist in
the recovery and healing process.
Heat treatments should be used for chronic
injuries or injuries that have no inflammation or
swelling. Heat applied to chronic conditions helps
relax and loosen tissues, and to stimulate blood
flow to the area.
When an injury is older than 48 hours, heat can
be applied. Heat causes the blood vessels to open
which brings more blood into the area. It also has
a direct soothing eect and helps to relieve pain
and spasm.
Sore, sti, nagging muscle or joint pain is ideal for
the use of heat therapy. Athletes with chronic pain
or overuse injuries may use heat therapy before
exercise to increase the elastici of joint
connective tissues and to stimulate blood flow.
Heat can also help relax tight muscles or muscle
spasms.
WHEN NOT TO USE HEAT
Heat should not be used on acute injuries. Wait
for the swelling to reduce. Heat draws fluids into
tissues and can increase swelling and
inflammation. Do not use heat over swollen
tissues or redness except under the supervision
of your doctor or physiotherapist.
Do not use heat before vigorous exercise. Your
muscles may be too relaxed for peak
performance and safe.
WHEN TO TREAT WITH COLD
Cold therapy (or cryotherapy) is the treatment of
choice for acute injuries (injuries that have
occurred within the last 48 hours). Our advice is
to only use the vibration on level 1 or 2 whilst
using the cold therapy, as too much vibration will
counteract the cooling benefits.
With any sprain, strain or bruise there is some
bleeding into the underlying tissues. This may
cause swelling, pain and delay healing. During
immediate treatment, the aim is to limit the body’s
response to the injury. It does this by reducing
further bleeding into the injured tissues,
preventing or reducing swelling, and reducing
muscle spasm and pain. Cold reduces pain by
numbing the area and by limiting the eect of
swelling which causes pain.
When applied immediately aer an injury, cold
treatment reduces tissue damage by reducing the
metabolic rate and decreasing the production of
metabolites and metabolic heat which result from
the body’s inflammatory response to the injury.
Cold therapy relieves muscle spasms, reduces
post-exercise soreness, and stimulates
circulation in areas of chronic discomfort.
Cold treatment may be used in both the immediate
treatment of so tissue injuries and in later
rehabilitation.
WHEN NOT TO USE COLD
Do not use over sensitive skin or in the
presence of poor circulation. Elderly people,
young children, and people with diabetes must be
very careful with cold treatments. If you have any
questions about cold therapy, ask your health
care practitioner for advice.
Aer plugging the adaptor into the power
socket the light of the power buon will go
red, this is a standby status and all other
functions can’t work.
Press the power buon once, the light will
change to blue, this is a ready status, now
you can use all the machine’s functions.
Pressing the cooling buon once will start
the cooling function. If you would like to
reduce the temperature even further then
press and hold the cooling buon for 3
seconds. The cooling buon will begin to flash
indicating that it is reducing its temperature
to the minimum possible. To stop the cooling
mode press the buon again.
Pressing the heating buon once will start
the heating function. If you would like to
increase the temperature even further then
press and hold the heating buon for 3
seconds. The heating buon will begin to
flash indicating that it is increasing its
temperate to the maximum possible.
WARNING: This mode is warm! Only use this
function when the basic heat mode is not
enough. To stop the the heating mode press
the buon again.
Cooling and heating mode can be turned on
alone, and can also be used together with the
vibration function.
Cooling and heating mode cannot exist
together. When one mode is started, the
other one will automatically stop.
Press the speed buon. You can choose 5
speed levels to see which is best for you.
HOW TO OPERATE
CONFIGURATION
9
10
1. Grip
7. Handle2. Intensi indicator
3. ON/OFF
4. Cooling mode buon
5. Heating mode buon
6. Speed adjustment buon
8. Massager nodes
9. DC interface
10. Adapter
1.
2.
3.
4.
5.
6.
7.
1
234567
8
Other Reviber Massager manuals
Popular Massager manuals by other brands

Medic Therapeutics
Medic Therapeutics 10 MOTORS FULL BODY MASSAGE MATTRESS user manual

Medisana
Medisana FM 885 instruction manual

Insportline
Insportline 21792 user manual

Human Touch
Human Touch WholeBody 2.0 Use & care manual

HoMedics
HoMedics homeSTRETCH BM-AC109J Instruction manual and warranty information

HoMedics
HoMedics SP-100H-CA Instruction manual and warranty information