1. Purpose of use
RFT-805D is a digital modulator designed for a processing two audio and two video signals into one
COFDM (DVB-T) multiplex.
2. Installation
The connections and indications are shown in Fig 1.
1. Cable-TV S channel indicator led
2. Channel number ( CCIR)
3.Control switch to program channel in ON position. The switch must
be set to OFF (DOWN) position when programming is ready1.
4. IR detector
5. VIDEO/AUDIO outputs for monitoring
6. Audio IN (right)
7. Audio IN (left)
8. RGB IN (blue) or YPbPr (Pb)
9. RGB IN (green) or YPbPr (Y)
10. RGB IN (red) or YPbPr (Pr)
11. Video IN and SCART SYNCHORIZING IN
12. USB port for software update
13. S-Video IN
14. When signal led is orange, the unit is initialized. When signal led
is green, the outgoing stream is ready. Red led means overfull stream.
15. DC IN (only in stand-alone installation)
16. RF OUT + DC IN in RFT-800 system installation
RFT-805D can be mounted either to RFT-800 system (RFT-800 User Manual) or stand-alone. Do not
cover the air passage holes.
Signals from AUDIO/VIDEO source are fed to Audio/Video connectors (RCA female) or S VIDEO IN.
When RFT-805D is mounted for RFT-800 system, the power voltage is supplied through active output
combiner (RFC-808 or RFC-816). When RFT-805D is mounted stand-alone, power supply unit (RFP-
804 or RFP-808) must be mounted to the left side of RFT-805D due to the ventilation. DC connector is
connected to left side of DC connector at the bottom of unit. You can loop-through DC from the right
side DC connector to next unit with the DC cable. Maximum four RFT-805D units in chain can be
supplied with one power supply (RFP-804) in stand-alone installation (max. two units with RFP-802).
When RFT-805D is mounted for RFT-800 system, cable to network is connected to active output
combiner (RFC-808 or RFC-816). When RFT-805D is mounted stand-alone, RF OUT is connected to
cable network.
VIDEO/AUDIO connectors (5.) are for monitoring the unit while programming.
NOTE! If video input is not connect, there are white stripes in video output due to the missing sync
pulse.
RF-Tuote Oy, Joensuunkatu 13, 24100 Salo, tel. +358-2736 6360, fa . +358-2-736 6360, info@rf-tuote.fi, www.rf-tuote.fi
3. Programming
The modulator is simple to program with the remote control unit (RCU-800). The main functions of
RCU are shown in Fig 2.
1. MENU Main OSD menu (exit without saving changes)
2. OK Confirm selection
3. EXIT Exit from menu (exit with saving changes)
4. ∧∧
∧∧∧∧
∧∧ Select a letter in service name
5. ∨∨
∨∨∨∨
∨∨ Select a letter in service name
6. CH ∧
∧∧
∧Change a letter in service name
7. CH ∨
∨∨
∨Change a letter in service name
Fig 2.
3.1 Power-up
At power-up this welcome screen is displayed. Main SW and user interface SW version numbers plus unit
serial number are shown.
When the unit is powered the display lights up showing selected output channel. The factory set channel is
E21.
The display is switched off after 3 minutes. Two signal led indicate that the unit is powered. The display
lights up again by pressing any button of remote controller unit.
The selected program info displayed and the channel opened.
RF-Tuote Oy, Joensuunkatu 13, 24100 Salo, tel. +358-2736 6360, fa . +358-2-736 6360, info@rf-tuote.fi, www.rf-tuote.fi
3.2 First time set-up
When using the unit for the first time, you must first connect video and audio source to audio/video inputs
and then connect video output to monitor. After this you can continue set-up using on-screen menus.
To control the unit first slide front panel switch to ON position. When programming is ready, the front panel
switch must be slide to OFF position. This will prevent accidental changes to be made while controlling
other units.
3.3 Set-up
To start set-up, press Menu key. Main Menu will be displayed.
Select “ Modulator Configuration”.
In Modulator menu can be selected:
- Output channel from S2 to E69
- DVB-T Constellation (QAM 64 is recommended)
- DVB-T FEC 1/2, 2/3, 3/4, 5/6 or 7/8 (3/4 is recommended)
- DVB-T Bandwidth 7 MHz or 8 MHz
- Output Level attenuator 0...20 dB (20 is maximum output level)
- Fine Tune of output frequency with 0,5 MHz steps
RF-Tuote Oy, Joensuunkatu 13, 24100 Salo, tel. +358-2736 6360, fa . +358-2-736 6360, info@rf-tuote.fi, www.rf-tuote.fi
Select “Encoder Configuration”
Following options can be selected for both channels:
- Input video signal Composite, S-video, RGB (synchorizing on GREEN), SCART RGB
(synchorizing on VIDEO), YPbPr (synchorizing on GREEN), SCART YpbPr (Synchorizing on
VIDEO)
- Hor. Resolution DI (full resolution 720*576), HD1 (half resolution 360*576) CIF (quarter resolution
360*288)
- GOP Size 6,12,15,24 or 30 (maximum frames per GOP: 18 (NTSC) / 15 (PAL)
- GOP Structure I (each GOP consist only of I-frames), IP (the encoder uses one I-frame and then only
P-frames inside a GOP), IBP (the encoder uses an I-frame at the beginning of the GOP and encodes
the rest in B- and P-frames) or IBBP (the encoder uses an I-frame at the beginning of each GOP and
encodes the rest in B- and P-frames)
- Const. Bitrate 1,5 Mbit/s, 2 Mbit/s, 4,5 Mbit/s or 6 Mbit/s
- Audio Sample Freq. 32,0 kHz, 44,1 kHz or 48 kHz
- Audio Bitrate 64 kbit/s, 128 kbit/s or 256 kbit/s
- Audio ES Mode Mono, Dual, Stereo
NOTE! The change of parameters are saved with “EXIT”. If “MENU” is selected, the change of parameters
is not saved.
RF-Tuote Oy, Joensuunkatu 13, 24100 Salo, tel. +358-2736 6360, fa . +358-2-736 6360, info@rf-tuote.fi, www.rf-tuote.fi
Select “Service Menu”
Following options can be selected:
- Service Name (Info is factory default). The name can be changed by selecting firstly a letter with
double arrow UP/DOWN and then select a correct letter with single UP/DOWN arrow. Save the name
with EXIT push button of RCU.
- PMT PID
- Video PID
- Audio PID
- Program Number (Logical Channel Number)
- Output Transport ID
- Output Original Network ID (used only in big cable operator networks)
-
NOTE! When programming is ready, check the status of bit rate. “Fill” beam shows how many percentage
of the maximum stream is used.
3.4 Other functions
In main menu you can select “Set Factory Defaults” .
RF-Tuote Oy, Joensuunkatu 13, 24100 Salo, tel. +358-2736 6360, fa . +358-2-736 6360, info@rf-tuote.fi, www.rf-tuote.fi
4. Technical specification
VIDEO ENCODER MPEG-2 COMPLIANT TO ISO/IEC13818-2
Max. bitrate 14 Mbit/s
AUDIO ENCODER MPEG audio layer ½
Compliant to ISO/IEC11172-3
Max. bitrate 256 kbps
COFDM OUTPUT
Modulation IFFT 2k mode, QPSK, QAM16, QAM64
Output frequency range 114 MHz - 858 MHz
Quard Interval 1/32
FEC 1/2, 2/3, 3/4, 5/6, 7/8
Output level 85 - 105 dBuV
Data interface USB 1
Input connector 12*RCA female, 2*mini DIN
Output connector F-male 75 ohm
Power consumption 16VDC/0,8A
Dimensions W*H*D 72mm*218mm*129mm
Mounting RFT-800 system or stand alone
RF-Tuote Oy, Joensuunkatu 13, 24100 Salo, tel. +358-2736 6360, fa . +358-2-736 6360, info@rf-tuote.fi, www.rf-tuote.fi
This symbol on the product or on its packing means that within the European Union the product must be
taken to separate collection at the product-end-of life.
Do not dispose of these products as unsorted municipal waste.
Fore more information about where you can drop off your waste equipment for recycling, please contact
your local city office, your house disposal service or the shop where you purchased the product.
RF-Tuote Oy, Joensuunkatu 13, 24100 Salo, tel. +358-2736 6360, fa . +358-2-736 6360, info@rf-tuote.fi, www.rf-tuote.fi

Other RF Modulator manuals

RF RFQ-845T2CI1 User manual

RF

RF RFQ-845T2CI1 User manual

RF FM-2ST User manual

RF

RF FM-2ST User manual

RF AV-200T User manual

RF

RF AV-200T User manual

RF RFT-855 User manual

RF

RF RFT-855 User manual

RF RFQ-845CI1 User manual

RF

RF RFQ-845CI1 User manual

RF RFT-856HD User manual

RF

RF RFT-856HD User manual

RF DTM-8HD User manual

RF

RF DTM-8HD User manual

RF RFQ-848 User manual

RF

RF RFQ-848 User manual

Popular Modulator manuals by other brands

BENDIX M-21-M-22 ANTILOCK MOD ASSY manual

BENDIX

BENDIX M-21-M-22 ANTILOCK MOD ASSY manual

Teledelta HDS2800 Series Operation and installation guide

Teledelta

Teledelta HDS2800 Series Operation and installation guide

Terra tdq420C manual

Terra

Terra tdq420C manual

Grundig GSS HDTV Series Assembly instructions

Grundig

Grundig GSS HDTV Series Assembly instructions

Security-Center Profiline TV8682 installation guide

Security-Center

Security-Center Profiline TV8682 installation guide

Lemco Micro line MLC-300 quick start guide

Lemco

Lemco Micro line MLC-300 quick start guide

Blauhaus HD1085 Installation information

Blauhaus

Blauhaus HD1085 Installation information

Pico Macom PCFM Installation and operation manual

Pico Macom

Pico Macom PCFM Installation and operation manual

Sennheiser SI 30 Instructions for use

Sennheiser

Sennheiser SI 30 Instructions for use

Kenwood KCA-R2FMA instruction manual

Kenwood

Kenwood KCA-R2FMA instruction manual

Pico Macom MPCM45 Specifications

Pico Macom

Pico Macom MPCM45 Specifications

Wellav IFQ332 user guide

Wellav

Wellav IFQ332 user guide

ProVideoInstruments VECOAX MICROMOD MS reference guide

ProVideoInstruments

ProVideoInstruments VECOAX MICROMOD MS reference guide

Polytron SPM-H4TCT user manual

Polytron

Polytron SPM-H4TCT user manual

Alcad 912-DMH Quick programming guide

Alcad

Alcad 912-DMH Quick programming guide

Motorola OM 2000 Installation & operation manual

Motorola

Motorola OM 2000 Installation & operation manual

Televes TOX Series quick guide

Televes

Televes TOX Series quick guide

Lemco HDMOD 5L Operation manual

Lemco

Lemco HDMOD 5L Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.