Rice Lake Ishida WM-Ai Installation instructions

Ishida WM-Ai
Cleaning, Sanitizing and Inspection Instructions
Use the following instructions to clean, sanitize and inspect the WM-Ai.
WARNING
Discharge unit
Bottom catch
tray (not
shown)
Infeed unit
Lift unit, wrap
plates and seal
rollers
Display
Important
This document can be viewed and downloaded from the Rice Lake Weighing Systems website at
www.ricelakeretail.com
Failure to heed may result in serious personal injury or death.
Always turn off the machine before cleaning or servicing.
Never touch this machine without training and authorization from your supervisor.
Guards must be in place before plugging in and turning on the machine.
Always keep your fingers, hands and clothing away from sharp or moving parts.
Failure to follow these instructions could result in damage to the equipment and void the
warranty.
Cleaning Points
Figure 1 calls out several parts of the WM-Ai that should be cleaned daily.
Figure 1. WM-Ai Cleaning Points
January 27, 2016 PN 174149

2WM-Ai Cleaning, Sanitizing and Inspection Instructions
Cleaning Procedure
Use the following steps to start the cleaning procedure.
1. Press the Cleaning button on the display.
Figure 2. Cleaning and Start Buttons
2. Press the Start button on the display. The machine takes approximately 10 seconds to fully move
into cleaning mode.
3. Turn the machine off by rotating the power switch to the right. The power switch is located to the
left of the discharge unit.
On/Off power
switch
location Off Position
Figure 3. On/Off Switch Location
4. Clean the lift unit, discharge unit, wrap plates and two sealing rollers with a damp cloth.
Lift unit Sealing rollers (not
shown but are
located behind
the safety cover)
Wrap plates
Discharge unit
Wrap plate
Figure 4. Clean Lift Unit, Wrap Plates and Seal Roller
CAUTION
Note
Use a brush to remove debris from within the lift unit.
Wait until the sealing rollers have cooled down before cleaning. Touching the sealing rollers
when they are hot may cause severe burns.

5. To clean the infeed areas, pull out the infeed unit by loosening the two knobs on the unit and
pulling the unit outward.
One knob shown.
Second knob on
opposite side.
Figure 5. Loosen the Infeed Unit Knobs
6. Remove and clean the infeed platter with soap and water. Do not use any chemicals or bleach that
will discolor the infeed platter.
7. Clean the infeed area with a damp cloth.
Figure 6. Cleaning Infeed Platter and Infeed Area
8. Open the bottom catch tray and clean the catch tray.
Figure 7. Catch Tray
9. Push the infeed unit all the way inward and tighten the two knobs.
WM-Ai Cleaning, Sanitizing and Inspection Instructions 3

4WM-Ai Cleaning, Sanitizing and Inspection Instructions
10. Clean the display and wipe down the front of the unit.
Figure 8. Display and Unit Front
Washdown Cover
A washdown cover protects the unit while cleaning the other areas of the room.
1. Ensure the machine is turned off.
2. After the machine has been cleaned, cover it with the washdown cover.
3. Spray and clean the room.
4. After the room is cleaned, remove the washdown cover and turn the machine back on. This will
protect the machine from condensation.
5. Press Return and Enter to return to normal operation.
230 W. Coleman St. • Rice Lake, WI 54868 • USA
U.S. 800-472-6703 • Canada/Mexico 800-321-6703 • International 715-234-9171 • Europe +31 (0)26 472 1319
www.ricelake.mx www.ricelake.eu www.ricelake.co.in
Rice Lake Weighing Systems is an ISO 9001 registered company.
© Rice Lake Weighing Systems Specifications subject to change without notice.
www.ricelake.com/retail
February 10, 2016 PN 174149
Figure 9. Return to Normal Operation