Rilox 3103 User manual

IR Manual
Version 1.0 Lug.2020
IR receiver 3103
required


INDEX
1.1 Products .........................................................................................................................................4
1.2 Preparation ....................................................................................................................................5
1.3 Button layout .................................................................................................................................6
2.1 Auto calibration..............................................................................................................................7
3.1 Programming Rilox Go-Rail motor units ........................................................................................8
3.2 Overview Programming Menus .....................................................................................................9
3.3 Programming options ..................................................................................................................10
Menu 1...........................................................................................................................................10
1.1 Set end positions..................................................................................................................10
1.2 Set IR channels .....................................................................................................................10
1.3 Set RF channels ....................................................................................................................11
Menu 2...........................................................................................................................................12
2.1 Opening and Closing Speed .................................................................................................12
2.2 Intermediate positions.........................................................................................................12
2.3 Light Sensor..........................................................................................................................13
2.4 CPS: Curtain Protection System ...........................................................................................17
Menu 3...........................................................................................................................................19
3.1 Operation mode...................................................................................................................19
3.2 Inverted input ......................................................................................................................20
3.3 Timer ....................................................................................................................................20
3.4 –3.6 (Reserved) ...................................................................................................................21
3.7 Factory Settings....................................................................................................................21
4.1 Transmitter...................................................................................................................................22
4.2 LED Signals....................................................................................................................................24
4.3 Connessioni..................................................................................................................................25

4
1. Infrared control
1.1 Products
Rilox Go-Rail motor units offer a wide range of features for optimal use in many situations. Feature
settings can be changed and stored by means of the buttons on the motor unit itself or other
controllers, e.g. the IR transmitter.
During programming, there is a visual feedback from the multicolor LED in the motor unit.
Transmitter
Go-Rail electric curtain rail systems can be operated and programmed with the
Rilox IR transmitter (3104) and the IR receiver (3103
).
The IR transmitter can transmit 15 different channels. On the IR transmitter,
IR channel ‘A1’ is pre-programmed as default.
To make changes in the IR channels, see p.11: “SET IR Channels” in Menu 1.
The transmitter uses 2 x AAA batteries (included).
Trasmitter
IR 3104
IR Receiver
The IR receiver is provided with 1 RJ45 plug and a IR-receiving eye. Cord lenght
is 100 cm.
The RJ45 plug is placed in the underside of the motor unit (see below for
detailed instructions).
The adhesive dot is used to place the receiving eye with its back against a
surface, such that IR signals from the transmitter can reach the eye. Each
receiver responds to up to 15 channels. This way, a curtain rail system can
respond to its individual IR signal and also to IR signals for a set ‘group’ or ‘all
systems’.
IR receiver
3103

5
1.2 Preparation
Trasmitter
Place the batteries in the trasmitter, 2 x AAA.
IR Riceiver
The connecting lead with RJ45 plug has to be inserted in the bottom side of the motor unit.
Place connector RJ45 here:
(underside motor unit
with bottom cover
removed).
The cable (100 cm) can be partly hidden, by using one of the side
channels in the motor unit housing with decorative strip. Replace
bottom cover to finish.
Multiple curtain rail systems:
Provide each system with an IR receiver, make sure to program systems one by one.

6
SET –used in setting the 24hr timer function
P –Programming button
RESET –used in setting the 24hr timer function
I –V:
Curtain control: Intermediate positions. pro-
gramming extra stops, up to five positions per
motor.
p.13: Setting intermediate positions
p.13: Using intermediate positions
Programming: no function
A –C: Channel group pre-selection
Curtain control: Press A, B, or C and then 1, 2,
3, 4 or 5 to select 1 out of 15 possible
channels (A1-A5, B1-B5, C1-C5).
The red LED indicates selection A, B or C.
Programming: No function
1 –5 OPEN / CLOSE:
Curtain control: Send an open or close signal on
selected channel A1 - A5, B1 - B5, C1 - C5.
Programming: Cycle through menu options
1.3 Button layout
The remote control 3104 can be used for operating and programming Go-Rail motor units. Below
an overview of the various buttons and their use.
Button timings:
Shortly press the button(s) (I)
= keep pressed less than 1 second
Press and hold the button(s) (I)
= keep pressed for more than 1 second
p.13
§ 3.3
p.8
§ 3.3

7
2. First Use
2.1 Auto calibration
The system will auto calibrate its end positions on first use, when the system is powered and
operated for the first time via IR channel ‘A1’.
After auto calibration, the system is ready for use and responds to Infrared channel ‘A1’ as default.
For motor types GM-x21-xxxx/x e GM-x10-xxxx/x (NOT for GM-1xx-xxxx/x).
To fine tune end
positions during
auto calibration,
these buttons can be
used.
1. Place the motor unit onto the curtain rail system
(see Go-Rail manual).
2. Place the curtains if possible and then adjust
internal endstop(s) if necessary, for improved
curtain pleating. (art. 3109, Allen key 2). These
stops are pre-secured and limit the running
distance of the pilot carrier. During the auto
calibration cycle below, electronically defined ‘soft
stops’ will be set with the 3109 stops as reference.
3. Connect an active power source (type depends on motor unit type).
4. Shortly press one of the buttons on the underside of motor unit or the controlling device.
5. The LED on the motor unit now flashes red.
6. The system will run until it is stopped by the internal end stop.
7. The system will move ~1cm in opposite direction and then waits for 5 seconds: within 5
seconds start fine tuning this end position if necessary, using the buttons.
8. After 5 seconds without signal, the calibration cycle continues. The system now runs in
opposite direction until it is stopped by the internal end stop.
9. The system will move ~5cms and then waits for 5 seconds: within 5 seconds start fine
tuning this end position if necessary, using the buttons.
10. After 5 seconds without signal, the system will move 20cm in Open direction, the cycle
stops and the red LED switches off. CPS mode is switched on automatically. The system is
now ready for use.
During auto calibration, the cycle can be aborted at all times by pressing one of the buttons.
3109

8
P button –enter a menu or to confirm an option.
OPEN / CLOSE buttons: cycle through menu/feature options
3. Programming
3.1 Programming Rilox Go-Rail motor units
Rilox Go-Rail motor units offer a wide range of features for optimal use in many situations. See §
3.2 on p. 9 for an overview of all available features.
Feature settings can be changed and stored using the buttons on the motor unit itself or the
Infrared transmitter.
Programming is done with aid of visual feedback from the multicolor LED in the motor unit.
Each programming feature is represented by 1 colour, for example the feature ‘setting end
positions’, shows a red LED.
Feedback also consists of blinking patterns to identify the selected feature setting.
To enter, navigate and make selections within Programming mode, these
buttons are used:
In programming mode all IR channels are active.
In the event of a power cut, the infrared channels will remain stored in the motor unit.

9
3.2 Overview Programming Menus
LED mode
LED colour
Menu 1
ON
Bianco
1.1
Endpositions
ON
Red
1.2
Set IR Channels
ON
Green
1.3*)
RF
ON
Yellow
(riservato)
LED mode
LED colour
Menu 2
Blinks slowly
White
2.1
Speed
ON
Red
2.2
DryC. Intermediate Positions
ON
Green
2.3
Light Sensor
2.3.1
Sun Sensor
ON
Yellow
2.3.2
Dawn/Dusk Sensor
ON
Blue
2.3.3
Sensor mode
ON
Purple
2.4
C.P.S.
2.4.1
Touch & Go
ON
Orange
2.4.2
Touch & Hold
ON
Light Blue
LED mode
LED colour
Menu 3
Blinks fast
White
3.1
Control mode
Red
3.2
CW / CCW inverted input
Green
3.3
Timer
Yellow
(riservato)
3.7
Factory Settings
Light Blue
*) If you have RF control, see RF manual for further control and programming options.

10
3.3 Programming options
Menu 1
1.1 Set end positions
Note: After 15s. without input, the motor unit quits programming mode. Please first read each step for this feature.
Infrared channel ‚A1‘ on the transmitter is active by default.
1. Place the curtains if possible and then adjust
internal endstop(s) if necessary, for improved
curtain pleating (art. 3109, allen key 2mm). These
stops are pre-secured and limit the running
distance of the pilot carrier. During the auto-
calibration cycle below, electronically defined ‘soft
stops’ will be set with the 3109 stops as reference.
2. Press and hold the P-button on the transmitter until the LED ON THE MOTOR UNIT turns
white (after ~4s.)..
3. Repeatedly press any OPEN or CLOSE button until the LED on the motor unit is red.
4. Shortly press the P-button to enter the feature menu, the LED on the motor unit now
flashes red.
5. The system will run until it is stopped by the internal end stop.
6. The system will move ~1cm in opposite direction and then waits for 5 seconds: within 5
seconds start fine tuning this end position if necessary, using the OPEN or CLOSE buttons.
7. After 5 seconds without signal, the calibration cycle continues. The system now runs in
opposite direction until it is stopped by the internal end stop.
8. The system will move ~5cms and then waits for 5 seconds: within 5 seconds start fine
tuning this end position if necessary, using the OPEN or CLOSE buttons.
9. After 5 seconds without signal, the system will move 20cm in Open direction.This
completes calibration and the red LED on the motor unit switches off. CPS mode is
switched on automatically. The system is now ready for use.
1.2 Set IR channels
Add and erase IR channels using the Infrared remote control.
Connect the infrared receiver to the underside of the motor unit. By default channel 1 is active.
Ensure the IR transmitter signals can reach the IR receiver.
Note: After 15s. without input, the motor unit quits programming mode.
Please first read each step for this feature.
motor LED colour red:
motor LED colour green:
3109

11
1. Press and hold the P-button on the transmitter until the LED ON THE MOTOR UNIT turns
white (after 4s.).
2. Repeatedly press any OPEN or CLOSE button until the LED on the motor unit is green.
3. Shortly press the P-button to enter the feature menu.
4. The LED on the motor unit now flashes green.
5. A –Activate a channel: to activate an IR channel, shortly press the OPEN button of the
desired channel on the IR transmitter. The LED on the motor unit responds with a short
continued green signal and then starts flashing again. If desired, add more channels one by
one to this motor unit, via OPEN buttons of corresponding IR channels.
B –De-activate a channel: to de-activate an IR channel, shortly press the CLOSE button of
that channel on the IR transmitter. The LED on the motor unit responds with a short
continued red signal and then starts flashing again. If desired, de-activate more channels
one by one to this motor unit, via CLOSE buttons of corresponding IR channels.
5A e 5B can be used in random order.
6. Shortly press the P-button to confirm the settings.
7. The LED on the motor unit is white again for 15 seconds: using the buttons another MENU
1 feature can be selected.
8. Otherwise, wait for 15 seconds or shortly press the P-button to quit programming. The LED
on the motor unit switches off, the system is ready to use.
To quit programming at any time, repeatedly press the P-button or wait for 15s. Changes made at
5 will only be saved if confirmed by pressing the P-button.
1.3 Set RF channels
(See RF manual)
motor LED colour yellow:

12
Menu 2
2.1 Opening and Closing Speed
Option to select 1 of 4 pre-defined speed settings. Default setting is „Normal“.
Nota: After 15s. without input, the motor unit quits programming mode.
Please first read each step for this feature.
1. Press and hold the P-button until the LED on the motor unit slowly flashes white (after
8s.) (First the LED will turn white continuously, keep the button pressed).
2. Repeatedly press any OPEN or CLOSE button until the LED on the motor unit is red.
3. Shortly press the P-button to enter the feature menu.
4. The LED on the motor unit now flashes red, at the current setting:
5. Cycle through the options below using OPEN or CLOSE:
6. Confirm and store setting by shortly pressing the P-button.
7. The LED on the motor unit slowly flashes white again for 15 seconds: using the OPEN or
CLOSE buttons another MENU 2 feature can be selected.
8. Otherwise, wait for 15 seconds or shortly press the P-button to quit programming. The LED
on the motor unit switches off, the system is ready to use.
To quit programming at any time, repeatedly press the P-button or wait for 15s. Changes made at
5 will only be saved if confirmed by pressing the P-button.
2.2 Intermediate positions
Define up to 5 intermediate curtain stopping positions, in between the systems end positions.
Default is setting is none.
Intermediate positions can quickly be recalled by pressing I, II, III, IV or V + after that OPEN or
CLOSE within 3s. of the desired channel on the IR transmitter. The system automatically moves to
the intermediate position (independant of the chosen direction OPEN or CLOSE).
Nota: . After 15s. without input, the motor unit quits programming mode. Please first read each step for this feature.
motor LED colour red:
1x flash =
Normal speed (Default)
2x flash =
High speed
3x flash =
Low speed
4x flash =
Open at low speed –Close at high speed / Custom speed.
motor LED colour green:

13
SET/ERASE intermediate positions (IR):
1. Using OPEN or CLOSE buttons, move the curtain in a desired position, to set a new
intermediate position or to erase an existing one.
2. Press and hold the P-button until the LED ON THE MOTOR UNIT slowly flashes white (after
8s.) (First the LED will turn white continuously, keep the button pressed.
3. Repeatedly press any OPEN or CLOSE button until the LED on the motor unit is green.
4. Shortly press the P-button to enter the feature menu.
5. The LED on the motor unit now flashes green, at the current setting (1).
6. Shortly press one of the buttons I, II, III, IV or V on the IR transmitter to store the current
curtain position; existing intermediate positions saved to that button previously will be
erased.
7. Confirm and store setting by shortly pressing the P-button.
8. The LED on the motor unit slowly flashes white again for 15 seconds: using the OPEN or
CLOSE buttons another MENU 2 feature can be selected.
9. Otherwise, wait for 15 seconds or press the P-button to quit programming.
To store another intermediate position, repeat § 2.2.2 entirely. Changes made at 5 will only be
saved if confirmed by pressing the P-button.
2.3 Light Sensor
The advanced Rilox Light sensor offers:
1. Sun light related sensitivity;
2. Dawn/Dusk related sensitivity;
3. Detailed behaviour settings.
Default setting for both Sun and Dawn/Dusk sensitivity is „Standard“ (see §2.3.1 e §2.3.2).
Default setting for overall behaviour is „Close at Dusk“. (see §2.3.3).
200cm

14
2.3.1 Sun light sensitivity
To use the Sun sensor, define its sensitivity (see below) AND its behaviour (§ 2.3.3).
Connect the Rilox light sensor to the underside of the motor unit via the RJ45 plug. Make sure that
the sensor is properly placed and oriented correctly towards the light source.
If light intensity exceeds set intensity for more than 5 mins. uninterrupted the sensor generates a
close signal.
If light intensity stays below set intensitiy for more than 15 mins. uninterrupted the sensor
generates an open signal.
The response to these signals can be defined in § 2.3.3.
If a Sun light induced event is overruled by another controlling signal (manual operation, time
controlled, remote control), the sensors Sun signal will be ignored for 4 hrs. The Sun sensor signal
is effective again after these 4 hrs. or after a power cut.
Dawn/Dusk events are not affected by an overruled Sun sensor event.
Note: After 15s. without input, the motor unit quits programming mode. Please first read each step
for this feature.
SET SUN LIGHT SENSITIVITY:
1. Press and hold the P-button until the LED on the motor unit slowly flashes white (after
8s.) (First the LED will turn white continuously, keep the button(s) pressed).
2. Repeatedly press any OPEN or CLOSE button until the LED on the motor unit is yellow.
3. Shortly press the P-button to enter the feature menu.
4. The LED on the motor unit now flashes yellow at the current setting.
5. Cycle through the options below using OPEN or CLOSE:
6. Confirm and store setting by shortly pressing the P-button.
7. The LED on the motor unit slowly flashes white again for 15 seconds: using the OPEN or
CLOSE buttons another MENU 2 feature can be selected.
8. Otherwise, wait for 15 seconds or shortly press the P-button to quit programming. The LED
on the motor unit switches off, the system is ready to use.
To quit programming at any time, repeatedly press the P-button or wait for 15s. Changes made at
5 will only be saved if confirmed by pressing the P-button.
motor LED colour yellow:
1x flash =
Normal sun intensity (Default)
2x flash =
Low sun intensity
3x flash =
High sun intensity
4x flash =
Current sun intensity

15
2.3.2 Dawn/Dusk light sensitivity
To use the Dawn/Dusk sensor, define its sentibility (see below) AND its behaviour (§ 2.3.3).
Connect the Goelst light sensor to the underside of the motor unit via the RJ45 plug. Make sure
that the sensor is properly placed and oriënted correctly towards the light source.
If light intensity exceeds set intensity for more than 5 mins. uninterrupted the sensor generates an
open signal (Dawn). If light intensity stays below set intensitiy for more than 5 mins.
uninterrupted the sensor generates a close signal (Dusk).
The response to these signals can be defined in § 2.3.3.
If a Dawn/Dusk light induced event is overruled by another controlling signal (manual operation,
time controlled, remote control), the sensors Dawn/Dusk signal will be ignored for 4 hrs. The
Dawn/Dusk sensor signal is effective again after these 4 hrs. or after a power cut.
Sun light events are not affected by an overruled Dawn/Dusk sensor event.
Note: after 15s. without input, the motor unit quits programming mode. Please first read each step
for this feature.
SET DAWN/DUSK SENSITIVITY:
1. Press and hold the P-button until the LED on the motor unit slowly flashes white (after
8s.) (First the LED will turn white continuously, keep the button(s) pressed).
2. Repeatedly press any OPEN or CLOSE button until the LED on the motor unit is blue.
3. Shortly press the P-button to enter the feature menu.
4. The LED on the motor unit now flashes blue at the current setting.
5. Cycle through the options below using OPEN or CLOSE:
6. Confirm and store setting by shortly pressing the P-button.
7. The LED on the motor unit slowly flashes white again for 15 seconds: using the OPEN or
CLOSE buttons another MENU 2 feature can be selected.
8. Otherwise, wait for 15 seconds or shortly press the P-button to quit programming. The LED
on the motor unit switches off, the system is ready to use.
To quit programming at any time, repeatedly press the P-button or wait for 15s. Changes made at
5 will only be saved if confirmed by pressing the P-button.
motor LED colour blue:
1x flash =
Average light intensity (Default)
2x flash =
Below average light intensity
3x flash =
Above average light intensity
4x flash =
Current light intensity

16
2.3.3 Light Sensor behaviour
To make use of the light sensor, define its response to Sun light signals and Dawn/Dusk light
signals. There are 8 preset patterns available.
Note: After 15s. without input, the motor unit quits programming mode.
Please first read each step for this feature.
SET LIGHT SENSOR BEHAVIOUR:
1. Press and hold the P-button until the LED on the motor unit slowly flashes white (after
8s.) (First the LED will turn white continuously, keep the button(s) pressed).
2. Repeatedly press any OPEN or CLOSE button until the LED on the motor unit is purple.
3. Shortly press the P-button to enter the feature menu.
4. The LED on the motor unit now flashes purple at the current setting.
5. Cycle through the options below using OPEN or CLOSE:
LED
DAWN / DUSK
SUN
OPEN
CLOSE
OPEN
CLOSE
1 X flash *)
OFF
ON
OFF
OFF
2 X flash
ON
ON
ON
ON
3 X flash
OFF
OFF
ON
ON
4 X flash
ON
ON
OFF
OFF
5 X flash
OFF
ON
ON
ON
6 X flash
ON
ON
OFF
ON
7 X flash
OFF
OFF
OFF
ON
8 X flash
OFF
OFF
OFF
OFF
*) Default settings
6. Confirm and store setting by shortly pressing the P-button.
7. The LED on the motor unit slowly flashes white again for 15 seconds: using the OPEN or
CLOSE buttons another MENU 2 feature can be selected.
8. Otherwise, wait for 15 seconds or shortly press the P-button to quit programming. The LED
on the motor unit switches off, the system is ready to use.
To quit programming at any time, repeatedly press the P-button or wait for 15s. Changes made at
5 will only be saved if confirmed by pressing the P-button.
motor LED colour purple:

17
2.4 CPS: Curtain Protection System
(only GM-4xx-xxxx series)
CPS is an intelligent declutching mechanism, it allows to manually operate the curtains.
Touch & Go: If a stationary hanging curtain is pulled sideways along the system, CPS will
detect movement and the curtain will automatically open or close depending on the pulling
direction.
Touch & Hold: Similarly, if a curtain is already moving, the movement can be stopped by
pulling the curtain in opposite direction from which it is moving.
Manual override: CPS also allows to manually move the curtains of G-Motion electric curtain
rail systems in case of a power cut. When power returns and the curtain was moved during the
power cut, the system starts recalibrating after the first control signal.
Touch and Go or Touch and Hold are set independently in § 2.4.1 and § 2.4.2 below.
Note: CPS response is subject to curtain weight, system layout and chosen treshold values. CPS is
meant as a manual overruling possibility or for occasional use in case the user is unaware that the
system is electrically operated; CPS is not suitable as standard controlling option.
Disclaimer: Though risk of damage is reduced by CPS, CPS cannot entirely prevent curtains or
curtain rail systems from being damaged. CPS is not advised for use in sloped systems.
2.4.1 Touch & Go
Touch and Go sensitivity is adjustable. For example at higher sensitivity, the motor unit will pick up
de manual operation sooner than at average sensitivity. At lower sensitivity setting, a larger
manual move of the curtain is needed before the motor unit takes over. This function can also be
switched off.
Note: After 15s. without input, the motor unit quits programming mode. Please first read each
step for this feature.
1. Press and hold the P-button until the LED on the motor unit slowly flashes white (after
8s.) (First the LED will turn white continuously, keep the button(s) pressed).
2. Repeatedly press any OPEN or CLOSE button until the LED on the motor unit is orange.
3. Shortly press the P-button to enter the feature menu.
4. The LED on the motor unit now flashes orange at the current setting.
5. Cycle through the options below using OPEN or CLOSE:
6. Confirm and store setting by shortly pressing the P-button.
motor LED colour orange:
1x flash =
Average sensitivity (Default)
2x flash =
Lower sensitivity
3x flash =
Higher sensitivity
4x flash =
Off

18
7. The LED on the motor unit slowly flashes white again for 15 seconds: using the OPEN or
CLOSE buttons another MENU 2 feature can be selected.
8. Otherwise, wait for 15 seconds or shortly press the P-button to quit programming. The LED
on the motor unit switches off, the system is ready to use.
To quit programming at any time, repeatedly press the P-button or wait for 15s. Changes made at
5 will only be saved if confirmed by pressing the P-button.
2.4.2. Touch & Hold
Touch and Hold self-calibrates during first 3 completed runs of the system, after resetting (new)
end postitions, changes in speed settings or after reactivating the feature.
Touch and Hold feacture has 2 settings: On or Off.
In some cases the Touch and Hold feature might not function as expeted: this is the case when
curtain fabric causes friction with floor, walls or the curtain track itself.
Or in case of any other source of resistance, causing the Touch and Hold function to be activated.
Touch and Hold auto-calibrates at regular intervals, but in cases it can be advised to start self-
calibration by switching this feature off and on again. If unexpected stopping of the system
remains, it is advised to switch off this feature.
Note: After 15s. without input, the motor unit quits programming mode. Please first read each
step for this feature.
1. Press and hold the P-button until the LED on the motor unit slowly flashes white (after
8s.) (First the LED will turn white continuously, keep the button(s) pressed).
2. Repeatedly press any OPEN or CLOSE button until the LED on the motor unit is light blue..
3. Shortly press the P-button to enter the feature menu.
4. The LED on the motor unit now flashes light blue at the current setting.
5. Cycle through the options below using OPEN or CLOSE
6. Confirm and store setting by shortly pressing the P-button.
7. The LED on the motor unit slowly flashes white again for 15 seconds: using the OPEN or
CLOSE buttons another MENU 2 feature can be selected.
8. Otherwise, wait for 15 seconds or shortly press the P-button to quit programming. The LED
on the motor unit switches off, the system is ready to use.
To quit programming at any time, repeatedly press the P-button or wait for 15s. Changes made
at 5 will only be saved if confirmed by pressing the P-button.
motor LED colour light blue:
1x flash =
On (Default)
2x flash =
Off

19
Menu 3
3.1 Operation mode
3 different operation modes are available, defining how the motor unit responds to OPEN and
CLOSE commands from 1- or 2-button controls.
SETTINGS:
I. Standard 2-button operation (default setting)
Button press < 1s. : system moves to endpostition.
Button press > 1s. : system moves small distance.
II. Inverted 2-button operation (‘vertical blinds’ setting)
Button press < 3s. : system moves small distance.
Button press > 3s. : system moves to endpostition.
Note: recalling intermediate positions or programming end positions for the first
time is not possible when this feature setting is active.
III. 1-button operation
button press < 1s.: system closes, opens or stops.
1) When the system is in one of its end positions → move to opposite end
position.
2) When the system is moving → STOP.
3) After a stop, press button again within 2s → move in opposite direction.
4) After a stop, press button again after 2s → continue in same direction.
Note: recalling intermediate positions in not possible when this feature setting is
active. After 15s. without input, the motor unit quits programming mode. Please
first read each step for this feature.
SET OPERATION MODE:
1. Press and hold the P-button until the LED on the motor unit flashes white at high speed
(after 12s.) (First the LED will turn white continuously, then flashes white slowly, keep
pressed until the LED flashes white at high speed).
2. Repeatedly press any OPEN or CLOSE button until the LED on the motor unit is red.
3. Shortly press the P-button to enter the feature menu.
4. The LED on the motor unit now flashes red at the current setting.
5. Cycle through the options below using OPEN or CLOSE:
6. Confirm and store setting by shortly pressing the P-button.
7. The LED on the motor unit flashes white at high speed again for 15 seconds: using the
OPEN or CLOSE buttons another MENU 3 feature can be selected.
motor LED colour red:
1x flash =
Standard 2-button operation (Default)
2x flash =
Inverted 2-button operation
3x flash =
1-button operation

20
8. Otherwise, wait for 15 seconds or shortly press the P-button to quit programming. The LED
on the motor unit switches off, the system is ready to use.
To quit programming at any time, repeatedly press the P-button or wait for 15s. Changes made at
5 will only be saved if confirmed by pressing the P-button.
3.2 Inverted input
Reverse the rotation of the motor unit: OPEN becomes CLOSE and vice versa.
Note: After 15s. without input, the motor unit quits programming mode. Please first read each
step for this feature.
SET INVERTED INPUT
1. Press and hold the P-button until the LED on the motor unit flashes white at high speed
(after 12s.).
(First the LED will turn white continuously, then flashes white slowly, keep pressed until
the LED flashes white at high speed)
2. Repeatedly press any OPEN or CLOSE button until the LED on the motor unit is green.
3. Shortly press the OPEN+CLOSE buttons or a P-button to enter the feature menu.
4. The LED on the motor unit now flashes green at the current setting:
5. Cycle through the options below using OPEN or CLOSE:
1x flash = Normal input (Default)
2x flash = Inverted input.
6. Confirm and store setting by shortly pressing the P-button.
7. The LED on the motor unit flashes white at high speed again for 15 seconds: using the
OPEN or CLOSE buttons another MENU 3 feature can be selected.
8. Otherwise, wait for 15 seconds or shortly press the P-button to quit programming. The LED
on the motor unit switches off, the system is ready to use.
To quit programming at any time, repeatedly press the P-button or wait for 15s. Changes made at
5 will only be saved if confirmed by pressing the P-button.
3.3 Timer
The built-in timer offers a 24hrs repeating function.
With the 24hrs repeating function a usage pattern can be recorded, which
then will repeat every 24hrs. The 24hrs repeating function can be easily
switched ON with SET and can be paused with RESET on the IR remote
control.
motor LED colour green:
motor LED color yellow:
This manual suits for next models
1
Table of contents