ring Keypad Z-Wave User manual

1
Keypad Z-Wave
Technical Manual

2
Ring Keypad
Adding Keypad to a Z-Wave Network
Ring Keypad can be added via smart start or via classic inclusion mode –
Smart Start Inclusion Steps:
1. Initiate add keypad flow in the Ring Alarm mobile application – Follow the guided add flow
instructions provided in the application
2. Scan the QR code found on the package of the keypad or the QR code found on the back
of the keypad
3. Plug in the keypad to line power
4. When the inclusion process in complete, the LED on the keypad will be solid blue, then go out.
5. Test the Keypad. Any button presses would beep
Classic Inclusion Steps:
1. Initiate add keypad flow in the Ring Alarm mobile application – Follow the guided add flow
instructions provided in the application
2. Select add manually and enter the 5 digit DSK pin found on the package of the keypad or the
QR code found on the back of the keypad
3. Plug in the keypad to line power
4. Press and hold “1” key for three seconds
5. When the inclusion process in complete, the LED on the keypad will be solid blue, then go out.
6. Test the Keypad. Any button presses would beep
This is a SmartStart enabled product which can be added into a Z-Wave network by scanning the Z-Wave QR Code present
on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will
be added automatically within 10 minutes of being switched on in the network vicinity.
This product can also be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers.
This product is not a main operated device.
Wake up is not supported in this device

3
Removing a Keypad to a Z-Wave Network
Exclusion Instructions
1. Initiate remove keypad flow in the Ring Alarm mobile application – Select the settings icon from
device details page and choose
“Remove Device”
2. Press and hold “1” key for three seconds
3. When the exclusion process in complete, the LED on the keypad will be solid blue, then go out.
4. Test the Keypad. Any button presses would not beep
Ring Base Station – Reset
Factory Default Instructions
1. Press and hold “5” key and using a pointed end of a paperclip, gently press and release
reset button via the reset pin hole found at the back of the keypad
2. Red network LED at the top left-hand corner will start to blink rapidly
3. Wait for the red LED to stop blinking then release the “5” key
Use this procedure only in the event that the network primary controller is missing or
otherwise inoperable.
Ring Keypad EU - Notification Information
Notification Supported Report:
Keypad supports Heat Alarm (0x04) and Home Security (0x07) and Power Management (0x08) and
System (0x09).
Event Supported Report:
Heat Alarm (0x04) : Clear State (0x00), OVERHEAT_DETECTED_UNKNOWN_LOCATION (0x02)
Home Security (0x07): Motion detection (0x08), State idle (0x00)
Power Management (0x08): State idle (0x00), Power has been applied (0x01), AC mains disconnected
(0x02), AC mains re-connected (0x03), Battery is charging (0x0C)
System (0x09): SYSTEM_SOFTWARE_FAILURE (0x04) with 0x55

4
Ring Keypad EU – Association Information
Association - Lifeline
This keypad has one Association group and Max 1 node. Group 1 is a lifeline group who will receive
unsolicited messages relating to entry control notifications, notifications reports, battery report
notifications, and device reset locally notifications
Ring Key EU – Configuration Information
Ring Keypad oers a wide variety of advanced configuration settings. Below parameters can be
accessed from main controllers configuration interface.
Parameter Size Default Value/
Dec Description
1 (0x01) 2 70 Battery Report Interval: Default Heartbeat check in time. Available settings:
70-1440 mins.
2 (0x02) 1 1 Z-Wave Sleep Timeout: Time to wait after receiving ZW for more OTA
messages. Available settings: 1-5 seconds
3 (0x03) 1 1 Co-Proc Is Alive: Base Station check to see if the co-proc is operational.
0 = No 1 = Yes
4 (0x04) 1 5 Proximity Timeout : Timeout when proximity is detected and no input
is received. Available settings: 0-30 seconds
5 (0x05) 1 5
Button Press Timeout : Timeout when a button is pressed, but a sequence is
not completed and buttons are no longer being pressed Available settings:
0-30 seconds
6 (0x06) 1 15 Status Change Timeout: Available settings: 10-60 seconds
7 (0x07) 1 0 Power Mode: Set the battery power saving mode for the keypad.
0=Extended Battery Life 1=Normal Battery Life
8 (0x08) 1 3 Key Backlight Timeout: Timeout for keypad LED backlight to stay on between
key presses. Available settings: 1-15 seconds
9 (0x09) 1 100 Key Backlight Brightness: Adjusts the brightness of the keypad backlight
Available settings: 0-100%
10 (0x0A) 1 8 Key Tone Volume: Volume, Tone Time, Frequency Available settings: 0-10
11 (0x0B) 1 5 Ambient Light Sensor Level: Light threshold where keypad will stop backlight-
ing if higher than Available settings: 0-100
12 (0x0C) 1 6 Siren Volume: Volume to produce loudest output, Needs to be calibrated
Available settings: 0-10
13 (0x0D) 1 1 Proximity On/OFF: Turn On and O the Proximity Detection.
0 = o 1 = on
14 (0x0E) 1 100
Proximity Distance: Adjusts the proximity distance (CM) If applicable to the
product.
Available settings: 0-100CM
15 (0x0F) 1 50
Extended Battery Life LED Brightness Adjustment: Percentage of brightness
for all LEDs in “Power
Mode” = Extended (needs calibration)
Available settings: 0-100%

5
To review your warranty coverage, please visit www.ring.com/warranty.
© 2020 Ring LLC or its affiliates.
Ring, Always Home, and all related logos are trademarks of Ring LLC or its affiliates.
Parameter Size Default Value/
Dec Description
16 (0x10) 1 65
Reduced Battery Life LED Brightness Adjustment: Percentage of brightness
for all LEDs in ”Power Mode” = Reduced (needs calibration)
Available settings: 0-100%
17 (0x11) 1 5 Fast Blink Rate: LSB = 0.1 sec Fast Rate Type to blink the LEDs
Available settings: 1-100
18 (0x12) 1 2 Slow Blink Rate: LSB = 0.5 sec Slow Rate Type to blink the LEDs
Available settings: 1-100
19 (0x13) 2 1500 Supervision Report Timeout. settings: 500-5000 millisecond
20 (0x14) 1 1 Number of Re-transmissions Attempts. settings: 0-5
21 (0x15) 1 5 Wait Period Between Re-transmissions Attempts. settings: 1-60 seconds
22 (0x16) 1 0 (US English)
Available settings: 0~31.
Set the languages to the keypad.
Get this configuration parameter and you can know the current Language
used for this Keypad.
Value/Decimal Languages
0 US English
1 UK English
2 French
3 German
4 Italian
5 Spanish
6 Dutch
7 Danish
8 Norwegian
9 Swedish
10 Finnish
11 Arabic
12-31 Undefined
23 (0x17) 4 -
Read Only!
Configuration Report Value:
BYTE 0
BYTE 1
BYTE 2
BYTE 3 Bit mask data for supported languages.
LSB format. Detail in below.
24 (0x18) 3 -
Read Only!
Configuration Report Value:
BYTE 0 Quantity of audio files
BYTE 1 Audio file version
BYTE 2 Audio file sub version
Table of contents
Other ring Keypad manuals
Popular Keypad manuals by other brands

Access Security Products
Access Security Products KP-902 Programming & installation manual

ANXELL
ANXELL E-Access E3AK Series instructions

CADDX
CADDX Ranger 9050 installation manual

Niles
Niles Solo-6MD user guide

NAPCO
NAPCO GEM-DXRP2 operating guide

Detection Systems
Detection Systems DS7400Xi reference guide

Transmitter Solutions
Transmitter Solutions Dolphin DOLXP1KB Programming & installation manual

Russound
Russound CA4-KP Installation and user manual

2gig Technologies
2gig Technologies 2GIG-EDG-RK quick start guide

CADDX
CADDX NX148-E installation manual

Comcast
Comcast UEI XHK1-UE Battery Installation

Blink Marine
Blink Marine PKP-1500-LI user manual