KPX PROGRAMMING For the Installer
4
NESS KPX KEYPAD INSTALLATION & OPERATION NOTES, Revision 2
Document Part Number 890-395
For the products: 106-015 Ness KPX Keypad Silver, 106-016 Ness KPX Keypad White
COPYRIGHT NOTICE
All rights reserved. No part of this publication may be reproduced, transmitted or stored in a retrieval system in any form or by
any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of Ness.
Ness reserves the right to make changes to features and specifications at any time without prior notification in the interest of
ongoing product development and improvement.
© 2009 Ness Security Products Pty Ltd ABN 28 069 984 372
P126E KPX KEYPAD OPTIONS
PROGRAM MODE LEVEL
Installer Program mode / NessComms
V5.3 or later.
FACTORY DEFAULT
All off.
NOTES
• One or all options can be enabled.
• To operate KPX double key functions
press and hold the matching keys for
at least 1.5sec. (In normal operating
mode only, keypad pairs are disabled in
programming mode).
RELATED OPTIONS
P61E 5E-8E Keypad PANIC outputs
P75E 2E Report MEDICAL alarms
P75E 3E Report PANIC alarms
P75E 4E Report FIRE alarms
The KPX has keypad pairs for Panic, Fire and
Medical alarms, a new blue LCD and special
chime modes.
These program options are available only in
D8x/D16x V6 and later.
TO PROGRAM
1. Press P126E.
2. Press 1E-5E to turn an option ON or OFF.
1E ON, enables double key PANIC.
2E ON, enables double key FIRE.
3E ON, enables double key MEDICAL.
4E ON, enables Entry Chime in Day mode.
Used to announce entry in Day mode.
5E ON, enable Chime in KPX keypads. Used
to announce entry in Monitor mode.
Programming
Programming option P126E in the D8x/D16x V6 control panels enable the KPX Panic,
Medical and Fire alarms as well as the Chime mode. The KPX can also be used with
previous versions of D8x/D16x panels but these KPX options will not be available.