Ringder RC-113M User manual

Temperature controlling parameters: ST, F01,F02.
ST: is stop temperature that can be adjusted by SET key directly.
is the high limit of setting temp.
These two parameters is used to limit the setting temp range in
order to avoid misoperation.
F01: is the low limit of setting temp.
F02:
F01≤ST≤F02
1.2.1Heating status description
RINGDE R
R
D
R
RINGDER
RC-113M
Top Runner in Temperature Measuring and Controlling Industr y
PID Temperature
Controller for Heating
User Manual
WEB: WWW.RINGDER.NET
Product Introduction
Xuzhou Ringder Electrical Equipment Co., Ltd.
Tel: 86-516-66656756 /87764448 FAX: 86-516-87769006
Website: http://www.ringder.net/indexen.asp;
http://ringder.en.alibaba.com/
Address: No. 385, Zhongshan North Road,Gulou District,Xuzhou City,Jiangsu Province, China.
E-mail:xzringder@outlook.com
Product Introduction
This model is specially designed for elaborate heating
system, which adopt high accuracy temperature sensor,
PID control, minimum temperature inertia, very high
control accuracy(0.1C within normal temperature
period).
RC-113M PID temperature controller is widely applied to
various equipments and places that need to control
temperature accurately, such as incubator, Heating
equipment in the laboratory etc.
Technique Specification
Anycontrol basic technique :specification list
Power supply
Rated power ≤1.5W
Load capacity
Sensor type NTC, 25℃/50KΩ
Protection class IP65
Work or storage -10~60℃, RH<90% no condensation
Temp. range -40~110℃
Environment Comply with environmental standards
Wire length Communication: 1Km,sensor:100m
220VAC±10% 50HZ
110VAC±10% 60HZ(optional)
≤1500W; 110V/60HZ/750W;
≤10A/220V/50HZ/2000W; 110V/60HZ/1000W(optional).
5A/220V/50HZ/
Function and Parameter
F01 -10~Set temp. -10
F02Set temp.~100 100
F03-7~7 0.0
Code Function Setting Range Default Unit
Set Low Lim it
Set High Li mit
Calibra tion
1.1.1 Temperature calibration
1.1 Temperature measurement
When there is some difference between the measuring
temperature and the real temperature, the difference can be
calibrated by menu F3, and calibration method should follow
the below formula:F3=real temperature-measuring
temperature. Other functions will execute according to the
calibrated temperature value.
1.1.2 Sampling period
The sampling period of this model is 1 second fixedly, and other
sampling period can be customized.
1.2 Temperature control
The controller can PID adjust the power of the heater, and make
the temperature constant around the setting temp. During
25~42℃, the accuracy can be 0.1℃.
Product Size
Wiring Diagram
Load Power Sensor
Connect the wires strictly according to the diagram, the voltage
must within 220VAC±10%.
The current of the load must: inductive load or filament lamp≤
10% of the current on the wiring diagram; resistive load≤60% of
the current on the wiring diagram.
Assembly and Installation
Warning:
Relative humidity>90%,have condensation
Strong vibration or struck
The places that temperature<-10℃ or>60℃;
Exposed to the continuous water mist spraying;
The places that have inflammables and explosives;
Exposed to the dust;
The controller must be connected by trained electricians
according to the user manual strictly, and avoid installing in the
below environments:
Wireless electromagnetic interference or strong magnetic
fields(near to transmitting antenna or switch board room);
2.1 Assembly
Exposure to corrosive and pollution gas (for example:the gas,
smoke or salt fog that contain sulfur or ammonia;
2.2 Please install the controller according to the following
Cut out a hole at the installing postion:71*29mm
Detach the slide fasteners, and put the controller into the hole.
(1st step,Figure2.a);
Install the faterners;
(2nd step,Figure2.b);
Figure2.aFigure2.b
After connecting the wire, install the waterproof tailgate
(3rd step,Figure2.c);
Figure2.c
How to disassemble the controller from the hole?
Firstly disassemble the
tailgate, then press the
position(Figure2.d)
sliding backwards to
disassemble the controler;Figure2.d
User Interface & Button Function
3.1 Display Area
220V/50 HZ
No.Meaning Working Status
/
/
/
1
2
3
Please
refer to
Display N ot Display Flash
Set Indic ator
Heat Equi pment
Alarm
Non set sta tus
Work status
Set statu s
Stop stat us
Alarm sta tus
Non alarm s tatus

SET
RST
SET SET
SET
SET
SET
SET
RST
3.2 Set the stop temperature
Press SET key can set the stop temperature,press
key can adjust the stop temperature; when finishing
adjustment,
press RST key to save and exit, or auto save and exit after 15
seconds without any operation.
Normal working status
Single-press
Adjust
Single-press or
no operation 15 sec.
Normal working status
3.2 Set Other Parameters
Press key for 3 seconds, enter into menu setting mode.
Press , key can shift parameter. If need to change
the value of the parameter, press SET key, then use key
to adjust the parameters’s value. When finishing setting, press
key to return to menu.Adjust the parameters in turn. When
finishing all settings, press key 3 seconds or no
operation for 15 seconds to save and exit.
SET
SET
RST
Normal working status
Press on
3 sec.
Show low temp limit Shift menu
Single-press
Set low temp limit Adjust Show high temp limit S hif t men u
Single-press
Single-press
Set high temp limit Adjust Shift menu
Single-press
Single-press
Calibration
Set calibration Adjust
Single-press or
no operation 15 sec.
Normal working status
Alarm, Error & Toubleshooting
Code Reason Troubleshooting
EEH
Sensor short circuit
or exceed the
highest measuring
temperature
Check the temperature of environment
where the sensor is pl aced, and whether
the s ens or is short ci rcuit, then repair
correspondingly.
EEL
Sensor open circuit
or exceed the
lowest measuring
temperature
Check the temperature of environment
where the sensor is pl aced, and whether
the s ens or is open ci rcuit, then repair
correspondingly.
Alarm error and troubleshooting
When alarm occur, icon flash, and buzzer sounds, if it is not
sensor fault, the fault code and temperature value will alternate
display, e.g. If it show FS, means the room sensor temp exceed
the storage protection temp in the defrost mode; if it is sensor
fault, it will only display the fault code.
Attention:
When alarming, press any key to mute the alarm, but the icon
will keep flashing, and the fault code will keep displaying until
trouble removal.
Accessory
Sensor wire x 1; slide fastener
tailgate
x 2
x 1; user manual x 1;
4.1 Sensor
The sensors that meet RINGDER criteria can apply to the
product, and the sensor cannot be put into the water directly.
The below is some parameters:
Wire: ; sensor size: φ2.1mm*2m φ4mm*20mm
The controller can be installed as far as about 100m,
but the cross section of the shielded wire must above 1mm
and any head of the wire mustn’t connect earth.
Attention please:
This model controller adopts NTC sensor without positive
and negative polarity, so no requirement for connection
order.
Please choose the suitable wire rod to connect, and check
connection fastness.
Please remember to cut off the power supply before
connecting.
This product has passed the European CE certification,
and conform to ISO9001 total quality control system.
Table of contents
Other Ringder Temperature Controllers manuals
Popular Temperature Controllers manuals by other brands

Wavelength Electronics
Wavelength Electronics LFI-3500 Series user guide

COQON
COQON qheat RS Installation & user guide

LEGRAND
LEGRAND Tynetec ZXT426 manual

Honeywell
Honeywell PRO 2000 Series Product data

Campbell
Campbell CS220 Information

ThermoFisher Scientific
ThermoFisher Scientific 2325 instruction manual