Rion UV-22 User manual

3-20-41 Higashimotomachi, Kokubunji, Tokyo 185-8533, Japan
https://www.rion.co.jp/english/
INSTRUCTION MANUAL
UV-22Viewer
UV-22


i
FOR SAFETY
In this manual, important safety instructions are specially marked as shown
below. To prevent the risk of injury to persons and severe damage to the unit
or peripheral equipment, make sure that all instructions are fully understood
and observed.
Caution
Important
Disregarding instructions print-
ed here incurs the risk of injury
to persons and/or damage to
peripheral equipment.
Disregarding instructions print-
ed here incurs the risk of dam-
age to the product.
Additional information about
using the unit. (These notes do
not directly affect safety.)
Note

ii
Caution
Do not play the disc in a CD player!
The CD-ROM containing this software is not a music CD. Inserting the
disc in a CD player poses the risk of excessive volume levels that can
cause hearing damage and damage to the CD player.
Important
About the Microsoft Windows operating system
This manual does not provide general information on how to use the
Microsoft Windows operating system. For general information about
selecting commands and making settings in dialog boxes, refer to the
documentation and online help of Microsoft Windows.
Examples for computer screens shown in this manual are for illustration
purposes only. The actual appearance of screens may differ, depend-
ing on the version of the Microsoft Windows operating system and the
computer environment.
* Company names and product names mentioned in this manual are usually
trademarks or registered trademarks of their respective owners.

iii
Software Usage License Agreement
Important
In order to use this Software, you must agree to the terms of the Software
Usage License Agreement (hereinafter “this Agreement”). Please read
the following text carefully, and only proceed to use the Software if you
agree to be bound by all the terms and conditions of this Agreement.
Article 1 Authorized Use
This Software (including updated or customized versions) is designed for use
with the interface unit UV-22 (hereinafter “the Product”). You are authorized
to use the Software only in conjunction with the Product, in such a way as
stipulated in this Agreement.
Article 2 Ownership of the Software
All rights to this Software are retained by RION Co., LTD, (hereinafter
“RION”) and/or its rightful owners. This Agreement grants you only a lim-
ited right to use the Software. This Agreement does not grant you any other
rights other than specied herein.
Article 3 Limitations to Use and Transfer
1. This Agreement does not grant you any rights to copy the Software and
any associated documentation.
2. This Agreement does not grant you any rights to alter or modify the
Software.
3. This Agreement does not grant you any rights to reverse engineer, de-
compile, recompile, or disassemble the Software.
4. Unless prior written permission from RION has been obtained, this
Agreement does not grant you any rights to lend the Software to any third
parties, regardless of whether this is done for payment or free of charge.
5. This Agreement does not grant you any rights to transfer the rights spec-
ied in this Agreement to any third parties.

iv
Article 4 Warranty Scope
1. RION does not make any representation or promise that this Software will
be able to perform without problems under any and all conditions. If a
problem occurs while the Software is being used under normal conditions,
contact RION using the information provided in the instruction manual.
As far as possible based on the information provided by you about the
problem, RION will provide guidance and information about possible
errors, improved operation procedures and similar.
2. RION (including any afliated companies or subsidiaries) does not assume
any liability for any damage caused by alteration or loss of data stored
in the Product, even if this is due to a defect or other problem with the
Software.
3. In no event does RION assume liability for any kind of direct or indirect
damage, loss of prot or anticipated gain, or any other damage caused by
the use of the Software, or the inability to use the Software.
4. In no event does RION assume liability for any problem caused by an
alteration or modication of the Software by you. RION also does not
assume liability for any damage caused to yourself by such an alteration
or modication.
Article 5 Duration of this Agreement
1. You can terminate this Agreement at any time by stopping to use the
Software and destroying the Software and all associated documentation.
2. If you violate any of the conditions of this Agreement, RION can cancel
this Agreement and terminate the usage of the Software. In such a case,
you are obligated to destroy the Software and all associated documentation
(including any unauthorized copies).

v
Article 6 Other Items
If the Software and the Product are taken from Japan to any other country,
the Japanese Foreign Exchange and Foreign Trade Law, the United States
Export Administration Act, and all other applicable laws and regulations
must be strictly observed. This Agreement shall be exclusively governed by
the laws of Japan.
Article 7 Third Party Beneciaries
This Software includes components for which the rights are held by other
parties except RION. In the case of a violation of this Agreement, in addition
to RION, such third parties shall also have the right to demand compensation
for damages.

vi
Contents
Software Usage License Agreement ............................................. iii
Outline ............................................................................................1
Preparations ....................................................................................3
Installation ......................................................................................4
Connections ....................................................................................9
Connections for USB link ....................................................9
Connections for LAN link .................................................10
Starting the Application ................................................................12
Startup screen ....................................................................12
Timeout setting screen ......................................................15
LAN Setting screen ...........................................................16
Instantaneous value display and setup screen ....................18
Contents of input setting.....................................................22
Input setting category .........................................................23
Measurement setting category ............................................25
User lter setting category .................................................28
Making a global setting .....................................................29

1
Outline
The UV-22Viewer Software is supplied with the Interface Unit UV-22 on a
single CD-ROM disc and is designed specically for use with the UV-22.
The software supports setup control, measurement value display, and other
functions for the Sound Level Meter Unit UN-14 and Vibration Meter Unit
UV-15 linked to the UV-22. The connection between UV-22 and a computer
can be established via a USB or Ethernet link.
Main functions
Control settings and display instantaneous value (updated every second)
for linked UN-14
Control settings and display instantaneous value (updated every second)
for linked UV-15
Input user lter values for linked UN-14/UV-15
Operation control: The software supports control of one UV-22 unit.
Via the UV-22 unit, the software can control up to 16 UN-14 and UV-15
units.
Precautions
• Suitable ID numbers must have been assigned to UN-14 and UV-15
units linked to the UV-22.
The ID number serves to uniquely identify a device in the system. Make
sure that ID number settings do not conict. If there is more than one
device in the system with the same ID number, correct operation is
not possible.
• Use the AC adapter NC-99 series to power the system during commu-
nication.

2
Outline
Operating environment
Supported operating systems:
Microsoft Windows 8.1 Pro (32 bit/64 bit)
Microsoft Windows 10 Pro (32 bit/64 bit)
CPU: Intel (R) Celeron (TM) processor 800 MHz or higher
RAM: 256 MB or more

3
Preparations
It is recommended that you insert the CD-ROM into the disc drive of your
computer and copy the entire folder and le structure from the CD-ROM to
the hard disk.
CD-ROM \Instruction Manual \Japanese
\English
\UV-22Viewer Software
\USB Driver \installer_x86
\installer_x64
\vb_sample
CD-ROM folder structure
Instruction Manual folder
Contains the documentation for the UV-22 and the UV-22Viewer in
electronic format.
UV-22Viewer Software folder
Contains the UV-22Viewer application software.
USB Driver folder
Contains the USB driver.
installer_x86:
For 32 bit Microsoft Windows 8.1 Pro/10 Pro
installer_x64:
For 64 bit Microsoft Windows 8.1 Pro/10 Pro
vb_sample folder
Contains sample software for retrieving data from the UV-22 using the
DOD command. The software is written in Visual Basic.

4
Installation
Install the USB driver on the computer as follows.
1. Start up the computer. Close any other software that is running.
When using 32 bit OS, execute the le “setup.exe” located in the
“installer_x86” folder.
When using 64 bit OS, execute the le “setup.exe” located in the
“installer_x64” folder.
The installation starts.

5
Installation
Follow the wizard to complete the installation.
Screens during installation are as follows.

6
Installation
Depending on your environment, [Windows Security] may be dis-
played. Click on “Install” or “Continue”.

7
Installation
2. Make sure that the POWER switch of the UV-22 is set to OFF and
that the communication function selector on the front panel is set to
USB.
3. Plug the USB cable into the USB port of the UV-22 and plug the
other end of the cable into the USB port of the computer. Then turn
on power to the UV-22.
* The USB driver can be installed also while the UV-22 is linked to
UN-14 and UV-15 units.
I
O
UV-22
POWER
RED:ERROR
USB
LOCAL
MASTER/SLAVE
USB
ETHERNET
POWER RESET
PICKUP
VIBRATION METER UNIT
UV-15
CAL
DISPLAY
INPUT
MEAS
RANGE
RMS
EQ
PEAK
EQ P-P
SETUP
PICKUP
VIBRATION METER UNIT
UV-15
CAL
DISPLAY
INPUT
MEAS
RANGE
RMS
EQ
PEAK
EQ P-P
SETUP
INPUT
SOUND LEVEL METER UNIT
UN-14
CAL
DISPLAY
INPUT
MEAS
RANGE
ACZ
SETUP
INPUT
SOUND LEVEL METER UNIT
UN-14
CAL
DISPLAY
INPUT
MEAS
RANGE
ACZ
SETUP
AC plug
Computer
USB port
AC ada
p
ter
USB cable with mini-B connector
Interface Unit UV-22
Sound Level Meter Unit UN-14 or
Vibration Meter Unit UV-15
may be linked during installation
(max. 16 units total)
UV-22
LOCAL
MASTER/SLAVE
USB
ETHERNET
POWER RESET
Set communication
function selector to USB
Front panel

8
Installation
When the computer detects the UV-22, the device driver software installation
is started automatically. When the installation has been completed, USB
communication is enabled.

9
Connections
Make connections as required, according to the type of interface to be used.
Connections for USB link
To use the UV-22, connect the AC adapter to the UV-22.
If the Battery Unit BP-17 is part of the system, connect the AC adapter
to the BP-17.
In this case, leave the POWER switch of the UV-22 constantly set to ON.
I
O
UV-22
POWER
RED:ERROR
USB
LOCAL
MASTER/SLAVE
USB
ETHERNET
POWER RESET
PICKUP
VIBRATION METER UNIT
UV-15
CAL
DISPLAY
INPUT
MEAS
RANGE
RMS
EQ
PEAK
EQ P-P
SETUP
PICKUP
VIBRATION METER UNIT
UV-15
CAL
DISPLAY
INPUT
MEAS
RANGE
RMS
EQ
PEAK
EQ P-P
SETUP
INPUT
SOUND LEVEL METER UNIT
UN-14
CAL
DISPLAY
INPUT
MEAS
RANGE
ACZ
SETUP
INPUT
SOUND LEVEL METER UNIT
UN-14
CAL
DISPLAY
INPUT
MEAS
RANGE
ACZ
SETUP
AC plug
Computer
USB port
AC adapter
Be sure to connect AC adapter to UV-22
USB cable with mini-B connector
Interface Unit UV-22 Sound Level Meter Unit UN-14 or
Vibration Meter Unit UV-15
(max. 16 units total)
UV-22
LOCAL
MASTER/SLAVE
USB
ETHERNET
POWER RESET
Set communication
function selector to USB
Front panel

10
Connections
Connections for LAN link
To use the UV-22, connect the AC adapter to the UV-22.
If the Battery Unit BP-17 is part of the system, connect the AC adapter
to the BP-17.
In this case, leave the POWER switch of the UV-22 constantly set to ON.
I
O
UV-22
POWER
RED:ERROR
USB
LOCAL
MASTER/SLAVE
USB
ETHERNET
POWER RESET
PICKUP
VIBRATION METER UNIT
UV-15
CAL
DISPLAY
INPUT
MEAS
RANGE
RMS
EQ
PEAK
EQ P-P
SETUP
PICKUP
VIBRATION METER UNIT
UV-15
CAL
DISPLAY
INPUT
MEAS
RANGE
RMS
EQ
PEAK
EQ P-P
SETUP
INPUT
SOUND LEVEL METER UNIT
UN-14
CAL
DISPLAY
INPUT
MEAS
RANGE
ACZ
SETUP
INPUT
SOUND LEVEL METER UNIT
UN-14
CAL
DISPLAY
INPUT
MEAS
RANGE
ACZ
SETUP
Computer
AC adapter
AC plug
15
No. 12345678
RION CO.,LTD.
MADE IN JAPAN
ETHERNET
Ethernet port
Rear panel of Interface Unit UV-22
Connect AC adapter to UV-22
LAN cable
Connect to computer or hub
Interface Unit UV-22
Sound Level Meter Unit UN-14 or
Vibration Meter Unit UV-15
(max. 16 units total)
LOCAL
MASTER/SLAVE
USB
ETHERNET
POWER RESET
Set communication function
selector to ETHERNET
Front panel

11
Connections
Important
Use only the optional AC adapter NC-99 series.
Using any other AC adapter can result in mal-
function and damage.

12
Starting the Application
Select the UV22Viewer.exe icon and double-click on it.
Startup screen
When the UV22Viewer.exe application is started, a startup screen such as
shown below appears.
Startup screen
The startup screen has the following buttons.
• USB button
Use USB link to connect to UV-22 and bring up the input settings screen.
• LAN button
Use LAN link to connect to UV-22 and bring up the input settings screen.
Before using LAN communication for the rst time, LAN settings must
be made using the LAN Setting screen.
• LAN Setting button
Use USB link to connect to UV-22 and bring up the LAN Setting screen.
Other manuals for UV-22
1
Table of contents
Other Rion Recording Equipment manuals