Risco LightSYS2 Instruction manual

LightSYS2 Quick User Guide 1
Quick User Guide
Thank you for choosing LightSYS2 flexible hybrid system. This quick start guide describes the
main user operating actions of the LightSYS2. To vie the full version of the user manual,
please refer to our ebsite www.riscogroup.com.
Register with RISCO Cloud (if enabled)
Registering ith RISCO Cloud enables you to monitor and control your LightSYS2 system.
Note: Registration and connection of your system to .riscocloud.com may depend on
your installer.
1. Go to .riscocloud.com/register.
2. Enter your first name and last name.
3. Enter your email address as Login Name (required for 1st time activation).
4. Define pass ord (minimum of 6 characters and at least one digit) and confirm.
5. Enter in the 15 digits Panel ID as it appears: on the postcard that arrived ith the
panel or supplied by the installer (also available in the keypad menu as described
belo ).
6. Complete registration form and click Register.
7. To complete registration open the email message received on the email account you
defined as Login Name.
Login to RISCO Cloud
1. Go to www.riscocloud.com
2. Enter User Name and Pass ord (same as supplied during the registration process).
3. Enter Passcode/PIN (LightSYS User Code).
4. Click nter.
iRISCO – RISCO’s Smartphone Application
Homeo ners can no enjoy the iRISCO Smartphone app for smart and easy control of their
LightSYS2 system from any location.
Do nload the iRISCO app from the Apple App store or Android Play Store (Search for
“iRISCO”).
Locating Panel ID in Keypad
1. From the main display press .
2. Enter master code (default code 1234) follo ed by .
3. Scroll to the option “Vie ” and press .
4. Scroll to “Service Info” and press .
5. Scroll to “Panel ID” and press 15 digit Panel ID is no displayed.

2 LightSYS2 Quick User Guide
Interface:
LCD Keypad (432KP)
Full (Away) Arm Code >
Part (Stay) Arm Code >
System Disarm a d
Sile ce a Alarm Code>
Partitio Away Arm Code > > Partition No. >
Partitio Stay Arm Code > > Partition No. >
Partitio Disarm Code> > Partition No. >
Duress Disarm Duress Code >
Pa ic Alarm Pressing simultaneously for 2 seconds
Fire Alarm Pressing simultaneously for 2 seconds
Medical Alarm Pressing simultaneously for 2 seconds
Quick Zo es Bypass Code > [Zone No.]
Activate Output [Code] [Activities] [ til Output Num]
Defi e Follow-Me >[Code] [Follow Me] [Define]
View Trouble [Code] [View] [Trouble]
View Eve t Log [Code] [Event Log]
Keypad Chime O /Off [Code] [Activities] [Keypad sound] [Chime]
Edit User Code [Code] [Codes/Tags] [Define]
Zo e Testi g (Walk Test
)
[Code] [Maintenance] [Walk Test]

LightSYS2 Quick User Guide
3
2-way Slim keypad
Operation Quick High-Security Mode
1
Full Arm – System > [Code]
2
Full Arm – Partition
Select partition
[1/2/3] >
Select partition [1/2/3]
> > [Code]
2
Full
Disarm > [Code] or Proximity tag (after waking
Partial Arm – System
3
> [Code]
Partial Arm – Partition
Select partition Select partition
[1/2/3] > [1/2/3] > > [Code]
Partition Disarm Select partition 1/2/3/4 and press followed by [Code]
Panic alar
m
Press + simultaneously for 2 seconds
Fire alar
m
Press + simultaneously for 2 seconds
Emergency/Med alarm Press + simultaneiously for 2 seconds
Status Reques
t
Press for 2 seconds to view
LED display of system status (see
Indicators below
Press for 2 seconds
followed by code
2
to view
LED display of system
status (see Indicators
below
Output Control Press 1/2/3 for 2 seconds Press 1/2/3 for 2 seconds
followed by code
2
ake up keypad Press
2-way Remote Control keyfob
Operation Quick High Security Mode
Full Arm > [Code]
Partial
Arm* > [Code]
Full
Disarm
> [Code]
System
Status for 2 seconds for 2 seconds > Code

4 LightSYS2 Quick User Guide
Output Control A/B/C for 2 seconds for 2 seconds
> [Code]
Panic Alarm simultaneously for 2 seconds
Clear Operation
Notes:
*For Part setting with no entry delay, press and hold for two seconds
1. Consult your installer for the operations defined with a code.
2. The proximity tag can be used instead of code.
3. For Part Setting (Stay Arming with no entry delay press for 2 seconds.
4. Light sensor is used to save battery by turning on/off the keypad backlight.
5. Needs to be defined by your installer.
Smartphone
Full Arm – System
Full Arm – Partition
>
Full Arm
–
Group
(if supported
>
Partial Arm – System
Partial Arm – Partition
>
System Disarm
> [Code]
Partition Disarm
>
Detector Bypass
(On/Off toggle)
> >
Web Application
ARM/DISARM
Full Arm All Partitions or PARTITION
x
> Full Set
Full Arm – Group
(if suppored
[Group Letter] > Full Set
Or PARTITION
x
> [Group Letter]
Part Arm All Partitions or PARTITION x > Partial Set
Disarm All Partitions or PARTITION x > [Code] > UNSET

LightSYS2 Quick User Guide 5
SETTINGS
System user and codes Edit, Delete and ADD NEW USERs
Web interface users and codes EDIT user fields and access credentials
Change Password Enter Old/New/Confirm SET NEW PASSWORD
Quick Zone Bypass Select ZONE xx Omit Update
Change Appearance Select Color Scheme
Alerts Add New Contact Enter Name, Email/Mobile phone #.
Select Alert Language, Partition association,
and toggle Set/Unset Email and SMS
Time Zone Select system TIME ZONE
HISTORY
Review activity log and export
AUTOMATION
Utility Outputs Toggle ON/OFF Update
Indicators:
LCD and Touchscreen Keypads
(Power):
On: Power OK, No troubles
Off: No power
Rapid Flash: System trouble
(Ready):
On: Ready to arm
Off: Not ready to arm
Slow Flash: Ready to arm with
open Exit/Entry zone
(Arm) RED LED
On: System armed
(Away or Stay)
Off: System disarmed
Slow Flash: System is
in Exit Delay
Rapid Flash: Alarm
(Tamper) :
On: Tamper alarm
Off: No tamper alarm
( Stay Bypass):
On: System armed at Stay / Bypass
zones in the system
Off: No bypass zones
(Fire):
On: Fire alarm
Off: No fire alarm
Flash: Fire trouble
(Proximity) [Touchscreen only]
Flashing indicates keypad has a
proximity reader.

6 LightSYS2 Quick User Guide
2-way Slim Keypad
LED Indicato
r
Colo
r
State Status
Blue Blin
k
During communication with the panel
Red On
Slow flash
Rapid flash
System fully or partially armed
During exit delay
During alarm
Green Blin
k
Trouble indication in the system while
the system is disarmed*
Green/Red Toggle Waiting for code to be entered
2-way Keyfob
Operation (Send command)* (Receive Status)
Full Setting (Away) Green Red
Part Set (Stay Arm) Green Orange
Unset (Disarm) Green Green
Alarm Green Flash LED
* If the LED changes to orange, it indicates a lo battery condition.
Edit User Code
1. From the main display press .
2. Enter master code (default code 1234) followed by .
3. Scroll to the option Codes/Tags .
4. Scroll to Define and press .
5. Select a user and press .
6. Select Edit Code and press .
7. Enter the new code followed by .
8. To edit user label scroll to Edit Label and enter label.
9. Repeat the above steps for additional codes.
Assign Proximity Tag
1. Follow steps 1-5 of the Edit User Code above.
2. Select (Re)Write tag and press .
3. Within 10 seconds, approach the proximity tag to the keypad.

LightSYS2 Quick User Guide 7
Setting and Changing System Time and Date
1. Press and enter grand master code followed by .
2. Using the arrow keys, scroll to the option Clock and press .
3. The display will show Time & Date. Press .
4. Enter the correct time in 24-hour format and date. For entering the date use the
keys to move the cursor and the / key to toggle among the choices.
5. Press to save your settings.
SMS Control Commands via GSM
Controlling the System through SMS
(Note: Available only if your LighSYS is equipped with the GSM module)
SMS Structure: [User Code][Command]
Full arm: [Code] A
Home Arm: [Code] H
Group Arm: [Code][G][Select Group
A/B/C/D])
Full Disarm: [Code] D
Partition Arm: [Code] A [Partition No.]
Partition Disarm: [Code] D [Partition No.]
Bypass zone: [Code] B [Zone number]
Unbypass zone: [Code] UB [Zone number]
Activate Output: [Code] UOON [UO No.]
Deactivate Output: [Code] UOOFF [UO
No.]
Get system status: [Code] ST
Get SIM credit level: [Code] CR
Change FM number: [Code] FMPHONE
[FM serial number] NEW [New Phone No.)
Examples:
To arm the system send SMS: 1234A
To arm partition 1 and 2 send SMS: 1234A12
To disarm partition 1 send SMS: 1234D1
Notes:
1. Command words are not case sensitive (they can contain both capital, small or mixed
lettering).
2. A separator between command words is not required, although it is accepted.
3. Default grand master code is 1234.
4. Add RP at the end of your SMS in order to receive a reply SMS from the LightSYS
acknowledging that your command has been successfully performed.
Example: To arm system and receive a reply acknowledging that the action was performed
send SMS: 1234ARP

8 LightSYS2 Quick User Guide
Telephone Control Commands
Remark: Available only if your LightSYS is equipped with a voice module.
eceiving a call:
1. Pick up the phone.
2. Say “Hello” press [#]. You will hear
an event announcement message.
3. Choose an option from the
Acknowledgment menu.
Acknowledgment menu
Acknowledge message: [1]
Acknowledge and stop all dialing: [2] [User code]
[#]
Access Operations menu: [3] [User code] [#]
Listen and Talk: [6] [3] [User code]
Repeat the event message: [#]
Repeat the Acknowledgment menu: [*]
Calling the System:
1. Dial the number of the
premises.
•If an answering machine is
present at the premises: Let
the line ring once, hang up
and call again.
•If an answering machine is
not in use at the premises:
Wait until the system picks
up. You will hear a
continuous tone.
2.After the tones, enter the 2-digit
remote access code.
3.Enter your user code followed by
[#].
4.Choose your option from the
Operations menu.
Operations Menu:
Arming all Partitions: [1] [1]
Arming by Partition: [1] [9] [Partition no.]
Disarming all Partitions: [2] [2]
Disarming by Partition: [2] [9] [Partition no.]
Changing Zone Bypass: [3] [Zone no.] [#] [9]
Operating Utility Outputs: [4] [UO no.]
Changing FM Numbers: [5] [FM no.] [#] [2] [New
phone no.]: [#] [1]
Listen in:[6] [1]
Talk:[6] [2]
Listen and Talk :[6] [3]
Record Messages : [7]
Exiting the System: [0]
Repeat the Menu: [#]
Return to previous menu: [*]
© RISCO Group 07/2013 5IN2087
Other manuals for LightSYS2
1
Table of contents
Other Risco Control System manuals
Popular Control System manuals by other brands

BriskHeat
BriskHeat ACR Series instruction manual

Parklio
Parklio Barrier user manual

eqss
eqss Gen-3 LMS installation manual

Motorline professional
Motorline professional MC62 User's and installer's manual

heat-timer
heat-timer VSP Installation & operating instructions

WAREMA
WAREMA Wisotronic installation instructions

Accutrol
Accutrol HSS1 Series quick start guide

Pilz
Pilz PNOZmulti Mini operating manual

Studio Technologies
Studio Technologies 236 user guide

Honeywell
Honeywell LYNX Touch L7000 Series Quick installation guide

Mitsubishi Electric
Mitsubishi Electric MELDAS 60 Series Programming manual

EMKO
EMKO TRANS-SYNCRO manual