manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Honeywell
  6. •
  7. Control System
  8. •
  9. Honeywell LYNX Touch L7000 Series User manual

Honeywell LYNX Touch L7000 Series User manual

LYNX Touch L7000 Series Control
Quick Installation Guide
This Quick Installation Guide can help you install the rechargeable LYNX Touch Series Control quickly and easily by providing the basic steps for installation using the built-in defaults.
FOR DOCUMENTATION AND ONLINE SUPPORT:
http://www.security.honeywell.com/hsc/resources/MyWebTech
(see LYNX Touch Series Installation and Setup
Guide P/N 800-16082 or higher.) A copy of the Installation and setup Guide may also be requested from Honeywell.
WARRANTY INFORMATION
For the latest warranty information, please go to:
www.honeywell.com/security/hsc/resources/wa
1. Install the Control
FRONT
CASE
7000-100-031-V1
MOUNTING
HOLES (4)
ROTATE
FRONT CASE
UPWARD
TO RELEASE
HOOKS
TIE WRAP
POINT (2)
ILP5
SPACER
DETAIL A
BACK
CASE
POWER
RECEPTACLE
CASE
TAMPER
INSTALL
SCREW
IN CASE
TAMPER
TAMPER
SWITCH
EDGE
CONNECTOR
BATTERY WIRE
ROUTING CLIPS (3)
MOUNTING
HOOKS
(HINGES)
BATTERY
CABLE CHANNEL
LOCKING TABS
TIE WRAP
POINTS (2)
TERMINAL
STRIP
EDGE
CONNECTOR
COMMUNICATION
MODULE
RECEPTACLE
2. Make Wiring Connections
7000-100-040-V1
2K
OHM
EOLR
HARD
WIRED
ZONE
WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM
EGND
EARTH
GROUND
HWZ1
TRIG
GND
GND
+9VDC
STANDARD CAPACITY
BATTERY CONNECTORS
SUPER HIGH CAPACITY
BATTERY CONNECTOR
ZONES POWER
EDGE CONNECTOR
(L5200-ZWAVE-EU)
EDGE CONNECTOR
(L5100-WIFI-ME)
TRIGGER OUTPUT (NEG)
(3ma)
OBSERVE POLARITY WHEN CONNECTING
THE POWER SUPPLY TO THE TERMINAL STRIP.
NOTE
THE 300-04705V1 OR
300-04705V1-EUR IS
AVAILABLE FROM
HONEYWELL AND MUST
BE PROVIDED DURING
INSTALLATION
300-04705V1 OR
300-04705V1-EUR
POWER SUPPLY
9VDC, 2.5A
ALL OUTPUT CIRCUITS ARE POWER LIMITED.
Note:For the complete Summary of Connections, refer to the LYNX
Touch Series Installation and Setup Guide P/N 800-16082 or
higher.
3. Install the Communications Module
Ensure that SIM card and the connector board are securely
installed in the communications module before installing it in
the LYNX Touch.
4. Make Battery Connections
7000-100-029-V0
OR
RETAINER
SCREW
RETAINER
SCREW
BATTERY PACK
(P/N 300-03866/
LYNXRCHKIT-SHA)
BATTERY PACK
(P/N 300-03864-1/
LYNXRCHKIT-SC)
1. Release the front case from the rear case by depressing the two
locking tabs at the top of the unit with the blade of a medium size
screwdriver.
2. Separate the front and back case assemblies by rotating the front
case so that it is perpendicular to the rear case and unsnapping
(releasing) the two hooks (hinges) from the back case.
3. Feed the wiring through the appropriate openings in the back
case. Use tie wraps to secure the wiring to the built-in wire loops
as needed.
4. Mount the back case to a sturdy wall and secure with the provided
screws.
5. If required, install an additional mounting screw in the case
tamper (see Detail A).
6. Attach the front and back cases by connecting the hooks on the
front case to the attachments on back case. Once attached, the
hooks will support the front case and allow you to make the wiring
connections.
7. After all of the wiring connections have been made, snap the front
case and back case closed and ensure that the locking tabs
secure the case.
1. Make earth ground connections to EGND terminal.
2. Connect the sensors/contacts to the HWZ1 (+) and GND (-)
terminals.
3. If used, install the communications module Refer to the Install the
Communications Module section or to the Installation Guide for
the Communications Module.
4. Connect wires from the 300-04705V1, 300-04065V1 OR 300-
04063V1 (Canada) Power Supply to GND (-) and +9VDC (+)
terminals OR plug the Power Supply connector into the receptacle
on the LYNX Touch.
!
RF Exposure Warning
The antenna(s) used for this transmitter must be installed to
provide a separation distance of at least 7.8 in (20 cm) from all
persons and not co-located or operated in conjunction with any
other transmitter except in accordance with FCC multi-transmitter
product procedures.
Important Note
If an external cellular radio antenna is used, the antenna must be
installed or replaced ONLY by a professional installer.
1. If you are installing the ILP5 module, use a wire cutter or knife to cut
the plastic tabs that secure the ILP5 spacer to the back case of the
LYNX Touch L7000. If you are installing a cellular communication
module, proceed to step 3.
2. Remove the ILP5 receptacle knockout from the left side of the
LYNX Touch back case
3 Install the Communications Module into the front case. Ensure that
the connector board is properly seated into the receptacle on the
control.
4 Secure the module with the three provided screws. If you are
installing the ILP5 module, proceed to step 5. If you are installing a
cellular communication module, proceed to step 8
5. Insert the ILP5 receptacle and spacer into the slot on the back
case.
6. Secure the communications cable to the tie wrap point on the ILP5
with the provided tie wrap.
7. Connect the Ethernet cable to the RJ45 receptacle.
8. Enable the module, configure alarm reporting and module
supervision and register the device. Refer to the “Communications
Diagnostics” section of the LYNX Touch L7000 Installation Guide
(P/N 800-16082 or higher).
1. Insert battery pack into back case.
2. Install battery retainer.
3. Install screw to secure the battery retainer.
4. Connect battery connector to receptacle on PC board.
5. After all wiring connections have been made, snap the front case
to the back case so it is held by the locking tabs.
6. Plug the Power Supply into a 24-hour, 110VAC unswitched outlet.
Note: Rechargeable batteries may take up to 48-hours to fully
charge. “Battery Low” message should clear within four hours,
or by entering Test Mode.
Battery
Part Number
Battery Standby
Time (Minimum)
Low Battery Notification
LYNXRCHKIT-SC
(300-03864-1) 4-hours Approx. 1-hour before
battery depletion
LYNXRCHKIT-SHA
(300-03866) 24-hours At least 1-hour before
battery depletion
Ê800-16088V1lŠ
800-16088V1 11/17 Rev. A
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
Copyright © 2017 Honeywell International Inc.
www.honeywell.com/security
CONNECTOR
BOARD
ILP5
LYNX TOUCH
REMOVE
ILP5
SPACER
REMOVE
ILP5
KNOCKOUT
SIM CARD
7000-100-032-V2
ROTATED
180
ROTATED
180
CONNECTOR BOARD
CONNECTOR BOARD
TIE
WRAP
POINT
NOTE:
SIM CARD INSTALLED
IN 3GL/3GLC ONLY
ILP5
SPACER
TIE
WRAP
(1)
LYNX TOUCH
ALTERNATE INSTALLATION
RJ45
RECEPTACLE
RJ45 RECEPTACLE
ETHERNET CABLE
SCREW
(3)
TO ILP5
RECEPTACLE
CELLULAR
COMMUNICATION
MODULE
(3GL/3GLC SHOWN)
Programming Notes
Entering Installer Programming mode
1. Power-up the control and allow it to “boot-up”. System
Standby! is displayed on the touch screen.
2. When the “boot-up” is complete (approximately 1-2 minutes)
“Ready to Arm” is displayed.
3. Select the “Security icon.
4. Select the “more” tab on the first page of the Home Screen.
5. Select “Tools” button.
6. Enter the 4-digit Installer Code (4-1-1-2).
7. Select “Program” button.
8. The System Programming Screen will appear and the Home
key will flash Green.
Exiting Programming mode
1. Once programming is completed, at the System Programming
screen, select the “” button.
2. Select the “Yes” when the system prompts “Allow Installer to
Re-Enter Programming?”.
3. Select the “Home” key to return to the Home Screen.
Entering Master User Programming mode
1. Power-up the control and select the “more” tab on the second
page of the Security Screen.
2. Select “Tools” icon.
3. Enter the 4-digit Master User Code (1-2-3-4).
4. The Master User Programming Screen will appear and the
Home key will flash Green,
5. Select the applicable programming function from the Master
User screen.
Exiting Programming mode
1. Once programming is completed, select the “” button to
return to the Master User Programming Screen. OR
2. Depress the “Home” key.
3. The system returns to the Home Screen.
5. Program the Control
Change the Installer Code
The factory default Installer Code for the LYNX Touch L7000 Series
Control is set to 4-1-1-2. To change this code, you must enter
Programming mode.
1. Select “Program” button.
2. Select “Installer Code” button. The current Installer Code is
displayed.
3. Select the “Clear” button then enter a new 4-digit Installer Code.
4. Select “Done” button
Program Date
Note: If you are installing a Cellular, L5100-WiFi or ILP5
Communication Module, the time and date will be programmed
and updated automatically via Central Station. You must still
program the correct Time Zone
To change this code, you must enter Programming mode.
1. Select “Program” button.
2. Select “Date Time” button.
3. Enter the date, time and time zone as required.
4. Select “Save” button.
Program Defaults
LYNX Touch is pre-programmed at the factory with a built-in set of
default values. Refer to the Programming Default Tables section of
the LYNX Touch Series Installation and Setup Guide (P/N 800-16082
or higher) to view the Default Tables. To select factory defaults from
a set of four tables, you must enter Programming mode.
1. Select “Program” button.
2. Select “Default Config.” button.
3. Select the desired Default Configuration.
4. Select “Yes” when the confirmation screen appears.
6. Add Wireless Sensors
Add a Sensor
To add, edit or delete Wireless Sensors you must enter Programming
Mode.
1. Select “Zones” button.
2. Select “’Add new” button.
3. Select the applicable Zone button.
4. Select “Serial Number” button
5. Enter Serial Number on the displayed keypad OR Enroll via RF
Learning. To enroll the transmitter, three (open/close)
transmissions of the device will be required.
6. If desired, program the following options:
Loop Number
Zone Description 1 and 2
Device Type
Response Type
Alarm Report
Chime
Supervision
Arm Night (if applicable)
7.Select “Save”.
Edit Wireless Sensor/Zone information
1. Select “Zones” button.
2. Select the Zone you wish to edit and then select the “Edit” button.
3. Edit the applicable zone programming fields as required.
4. Select “Save”.
Delete a Wireless Sensor
1. Select “Zones” button.
2. Select the Zone you wish to delete then select the “Delete” button.
3. Select the “Yes” button when the confirmation screen appears.
7. Add Wireless Keys
To add, edit or delete a Wireless Key you must enter Programming
Mode.
Add a Wireless Key
1. Select “Keys” button.
2. Select ’Add New” button.
3. Select the “Key Type” button and scroll through the available key
types.
4. Select “Serial Number” Button
5. Enter Serial Number or Enroll via RF Learning. To enroll the
transmitter, three (open/close) transmissions of the device will be
required.
6. Select the “User” button and then select the User that will be
associated with the key that is being enrolled.
Note: A valid User Code must be associated with the User assigned
to the key.
7. If desired, program the following options:
Zone
Button Key * - Zn **
8. Select “Save”.
* Button number is determined by the type of key being enrolled.
** Zn No. based on the type of key being enrolled.
Edit Wireless Key information
1. Select “Keys” button.
2. Select the Key you wish to edit and then select the “Edit” button.
3. Edit the applicable fields as required
4. Select “Save”.
Delete a Wireless Key
1. Select “Keys” button.
2. Select the Key you wish to delete then select the “Delete” button.
3. Select the “Yes” button when the confirmation screen appears.
8. Add Central Station Accounts
To add Central Station Account information, you must enter
Programming Mode.
Add First or Second Central Station Information
1. Select the “Reporter” button.
2. Select the “Primary CS Info” or “Secondary CS Info” button.
3. Program the following fields as applicable:
Phone Type
Phone Number
Communicator Type
Account Number
Dynamic Priority
Dynamic Delay
Report All
Report Alarms
Report Troubles
Report Open/Close
Report Tests
4. Select the “Save” button when programming is complete.
!
All four digits of the Central Station Account numbers
must be entered. For ten-digit format, all ten digits must be
entered. Refer to the LYNX Touch Series Installation and
Setup Guide for additional information regarding these
programming options.
9. Register the Communications Module
The Communications Module can be registered either via the
AlarmNet Direct Website, by Phone or through the LYNX Touch
Diagnostics. For additional information on the first two methods refer
to the LYNX Touch L7000 Series Installation and Setup Guide P/N
800-16082 or higher.
Register through LYNX Touch Diagnostics
To Register the Communications Module, you must enter
Programming Mode.
1. Select the “Comm. Diagnostics” button.
2. Select the “Setup Communications” button.
3. Select the “Register Device” button. The registration message is
sent and the unit waits for the acknowledgement. (Refer to the
LYNX Touch Installation and Setup Guide P/N 800-16082 or
higher for additional information)
10. Program User Functions
To perform these functions, you must enter the Master User
Programming mode.
Add Users
1. Select the “Users” button.
2. Select the “Add New”
button.
3. Enter a User Name.
4. Enter a 4-digit User Code.
5. Select “Done”.
Change the Master User Code
1. Select the “Users” button.
2. Select the “Master” button.
3. Select the “Edit”
button.
4. Enter a new 4-digit User Code.
5. Select “Done”.
Change/Edit Users or User Codes
1. Select the “Users” button.
2. Select the applicable “User” button.
3. Select the “Edit”
button.
4 Revise the User name, if applicable, then select “Done”.
5. Enter a new 4-digit User Code, if applicable, then select “Done”.
Delete User Codes
1. Select the “Users” button.
2. Select the applicable “User” button.
3. Select the “Delete”
button.
4. Enter a new 4-digit User Code.
5. Select “Yes” when the confirmation screen appears.
11. Test the system
To perform this function, you must enter the Installer OR
Master User Programming mode.
1. Select the “Test” button or icon.
2. Select the “Walk Test” button or icon.
3. Open each protected door and listen for three beeps from the
keypad, followed by the zone’s Voice Descriptor. Identification of
each faulted protection point should appear on the display, and
clear when the door is closed.
4. Walk in front of the motion sensor and listen for three beeps and
the zone’s voice descriptor.
5. When testing is complete, enter an OFF sequence.
6. Press each key on the key fob to confirm it performs its assigned
function.
Note: Refer to the Lynx Touch L7000 Series User Guide P/N 800-
16084 or higher for additional information.

Other manuals for LYNX Touch L7000 Series

4

Other Honeywell Control System manuals

Honeywell 900CS10-00 User manual

Honeywell

Honeywell 900CS10-00 User manual

Honeywell LYNX Touch Security System User manual

Honeywell

Honeywell LYNX Touch Security System User manual

Honeywell RA116A User manual

Honeywell

Honeywell RA116A User manual

Honeywell XLS80e User manual

Honeywell

Honeywell XLS80e User manual

Honeywell Excel 500 User manual

Honeywell

Honeywell Excel 500 User manual

Honeywell Tradeline H1008D User manual

Honeywell

Honeywell Tradeline H1008D User manual

Honeywell Experion LX 8 series User manual

Honeywell

Honeywell Experion LX 8 series User manual

Honeywell ACC 50 User manual

Honeywell

Honeywell ACC 50 User manual

Honeywell Experion LX User manual

Honeywell

Honeywell Experion LX User manual

Honeywell Excel 800 Installation and operation manual

Honeywell

Honeywell Excel 800 Installation and operation manual

Honeywell SILENT KNIGHT SK-Zone-6 User manual

Honeywell

Honeywell SILENT KNIGHT SK-Zone-6 User manual

Honeywell vk41 series User manual

Honeywell

Honeywell vk41 series User manual

Honeywell W7080A User manual

Honeywell

Honeywell W7080A User manual

Honeywell Experion LX Manual

Honeywell

Honeywell Experion LX Manual

Honeywell SmartVFD User manual

Honeywell

Honeywell SmartVFD User manual

Honeywell Excel 500 User manual

Honeywell

Honeywell Excel 500 User manual

Honeywell Experion PKS User manual

Honeywell

Honeywell Experion PKS User manual

Honeywell NOTIFIER ACS Series User manual

Honeywell

Honeywell NOTIFIER ACS Series User manual

Honeywell T8205B Operation manual

Honeywell

Honeywell T8205B Operation manual

Honeywell 5704 User manual

Honeywell

Honeywell 5704 User manual

Honeywell MRP-2002E User manual

Honeywell

Honeywell MRP-2002E User manual

Honeywell VR9105V User manual

Honeywell

Honeywell VR9105V User manual

Honeywell Smile Room Connect SRC-10 User manual

Honeywell

Honeywell Smile Room Connect SRC-10 User manual

Honeywell EVOTOUCH CONTROLLER User manual

Honeywell

Honeywell EVOTOUCH CONTROLLER User manual

Popular Control System manuals by other brands

Inspire ignite manual

Inspire

Inspire ignite manual

Lectrotab MLC-1 Installation & operation manual

Lectrotab

Lectrotab MLC-1 Installation & operation manual

Roger B73/LTM Instruction and warnings for the installer

Roger

Roger B73/LTM Instruction and warnings for the installer

Nice MORX installation instructions

Nice

Nice MORX installation instructions

Hardi HC 2500 Series Instruction book

Hardi

Hardi HC 2500 Series Instruction book

oventrop Regumat F-130 Installation and operating instructions

oventrop

oventrop Regumat F-130 Installation and operating instructions

Spohn & Burkhardt SV1C Series operating instructions

Spohn & Burkhardt

Spohn & Burkhardt SV1C Series operating instructions

Next Wave CNC SHARK installation manual

Next Wave CNC

Next Wave CNC SHARK installation manual

Aventura VPO-411PC user manual

Aventura

Aventura VPO-411PC user manual

Crestron Electronics UC-B31-T quick start

Crestron Electronics

Crestron Electronics UC-B31-T quick start

Aqua Control C2500 manual

Aqua Control

Aqua Control C2500 manual

Carbide 3D Shapeoko XL Assembly guide

Carbide 3D

Carbide 3D Shapeoko XL Assembly guide

Abus 505272 quick start guide

Abus

Abus 505272 quick start guide

Carbide 3D SHAPEOKO 3 Assembly guide

Carbide 3D

Carbide 3D SHAPEOKO 3 Assembly guide

Spraying Systems TeeJet TECHNOLOGIES BoomPilot installation manual

Spraying Systems

Spraying Systems TeeJet TECHNOLOGIES BoomPilot installation manual

Carbide 3D Shapeoko HDM Getting started guide

Carbide 3D

Carbide 3D Shapeoko HDM Getting started guide

Siemens SiPass Entro Operation manual

Siemens

Siemens SiPass Entro Operation manual

Fly Sky FS-i6 Programming Instruction

Fly Sky

Fly Sky FS-i6 Programming Instruction

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.