Ritelite RITE-POWER 615 User manual

300W 110V / 230V
This manual covers the Rite-Power 615 with the following product codes:
SLK310BP2/300/230/AMF100/TE-F | SLK310BP2/300/230/AMF100/T60309
SLK310BP2/300/110/AMF100/T60309
The information contained in this manual is based on products manufactured up to the time of publication.
Ritelite (Systems) Ltd reserves the right to change any of this information without notice.
No part of this manual may be reproduced in any form or by any means, electronic or mechanical without express
written permission from Ritelite (Systems) Ltd.
Any type of reproduction or distribution not authorized by Ritelite (Systems) Ltd represents an infringement of valid
copyrights, and violators will be prosecuted. We expressly reserve the right to make technical modifications, even
without due notice, which aim at improving our products or their safety standards.
Product Resources

2
IMPORTANT INFORMATION ABOUT YOUR
RITE-POWER 615
PORTABLE BATTERY POWERED GENERATOR
Use this page to record important information about your RITE-POWER 615.
UNIT PRODUCT REFERENCE
UNIT SERIAL NUMBER
This information can be found on your RITE-POWER 615 data plate which is found at the rear of
the unit.
NOTE: Below is an example of the RITE-POWER 615 data plate.
You will be required to supply the products serial number when contacting Ritelite (Systems) Ltd or
one of Ritelite’s approved dealers about parts and service.

3
CONTENTS
SECTION TITLE PAGE NUMBER
Section 1: Introduction & applications for use 4
Section 2 : Safety rules 5
Section 3: Technical specifications 9
Section 4: Setting up the RITE-POWER 615 10
Section 5: Operating instructions 12
5a) Pre-operation inspection 12
5b) Using the RITE-POWER 615 13
5c) Recharging the RITE-POWER 615 16
5d) Packing away and transport 18
5e) Storage / transport mode 18
Section 6: Troubleshooting 19
Section 7: Maintenance 20
6a) Advice on disposal 21
6b) Disclaimer of warranty 21

4
Section 1: INTRODUCTION & APPLICATIONS FOR USE
The RITE-POWER 615 is designed as an industrial portable power generator supplying continuous
AC mains power up to 300W for equipment requiring 230V AC 50Hz or 110V 60Hz, depending on
model chosen. It has the added feature of a built-in charger with a mains input and a changeover
relay that allows power from the mains to pass through to a load whilst keeping the battery charged,
then if the mains fails the system can support the load (if within the compatibility of the inverter)
automatically for a duration dependant on load.
It uses a bespoke Lithium Ion (615W/h) battery with a dedicated battery management system to
supply a pure sine wave inverter producing a clean reliable supply powering most compatible
equipment up to 300W.
It is housed in a ruggedised waterproof IP65 case with industrial input and output sockets for
charging and discharging of the unit. In addition, a display on the front of the case indicates run
times based on the current load, recharge time based on the in-built charger and other information
pertaining to the battery voltage, current, state of charge and capacity. A single switch turns the
system on and off and contains a red warning LED to indicate any fault conditions including low
battery supply, over temperature, overload and short circuit.
All users must read, understand and obey any instructions and information contained herein these
operating instructions before use. Only trained or competent personnel should use the RITE-POWER
615.
This Manual should always stay with the RITE-POWER 615.
APPLICATIONS FOR USE
The RITE-POWER 615 is designed for use in the following applications only. It should not be used for
any other purpose. If in any doubt about applications for use, please contact either Ritelite (Systems)
Ltd or Ritelite (Systems) Ltd’s distributor for more information.
• Powering resistive load equipment up to a max continuous load of 300W.
• Powering capacitive load equipment up to a max continuous load of 300W.
• Avoid powering Inductive loads (Items with motors in) or limit their load to 60W max.
Note: Some loads may fail to run at all from the RITE-POWER Generator or cause the inverter system
within the generator to behave abnormally causing it to shut down, if this happens disconnect the load
and don’t attempt to retry.
Failure to follow the instructions and safety rules in this manual may result in death
or serious injury.

5
Section 2: SAFETY RULES
It is important that every user understands and observes the safety
rules before setting up or using the RITE-POWER 615 Portable
Battery Powered Generator.
The Manufacturer, Ritelite (Systems) Ltd cannot anticipate every possible circumstance that
might involve a hazard. The warnings in this manual and on labels affixed to the RITE-POWER
615 will therefore not cover every eventuality. If using a procedure or operating method not
specifically recommended by the manufacturer then the user must verify that it is safe for
others and that it does not make the equipment unsafe.
Throughout this manual and on labels on the RITE-POWER 615, DANGER, WARNING and
CAUTION blocks are sometimes used to alert personnel to special instructions about a
particular operation that may be hazardous if performed incorrectly or carelessly. Observe them
carefully. Their definitions are as follows:
These safety alerts cannot eliminate the hazards that they indicate.
Common sense and strict compliance with the instructions within this
manual are essential to preventing accidents.
Indicates a hazardous
situation which, if not
avoided, will result in
death or serious injury.
Indicates a hazardous
situation which, if not
avoided, could result in
death or serious injury.
Indicates a hazardous
situation which, if not
avoided, could result in
minor or moderate injury.

6
When using the RITE-POWER 615 indoors or outdoors, basic safety
precautions should always be followed to reduce the risk of fire, electric
shock and personal injury including the following:
a) Ensure the IP rating of the connecting plug to coupler application is suitable
for the prevailing conditions.
b) Read and understand the implications from the MSDS (Material
Safety Data Sheet) for the product, for both use and transport/
shipping. The MSDS can be viewed the following link or by
scanning the QR code on the right:
https://ritelite.co.uk/product-resources/rite-power/
c) Do NOT allow the RITE-POWER 615 to become submersed under water or
allow any liquid to enter inside the product.
d) Use only with an extension cord appropriate for outdoor use.
e) Do NOT use damaged cables or connectors.
f) All cables and equipment must be double insulated.
GENERAL SAFETY RULES & POTENTIAL HAZARDS
WHEN SETTING UP AND USING THE RITE-POWER
615 PORTABLE BATTERY POWERED GENERATOR
FALL HAZARDS
• Do NOT place the RITE-POWER 615 anywhere it could fall on to personnel.
• Do NOT stand on the RITE-POWER 615 or use it as any form of step.
TIP OVER HAZARDS
• Where ground or the area is uneven place the RITE-POWER 615 on its base to ensure
it can’t fall over.
• Prior to setting up check the area for any possible hazardous conditions.
• Do NOT place ladders or scaffolding against any part of the RITE-POWER 615.
• Do NOT use the RITE-POWER 615 on a moving or mobile surface without strapping it
down to prevent unexpected movement.

7
• Use the integrated handles to safely carry/move the RITE-POWER 615.
• Do NOT use the RITE-POWER 615 for any purpose other than that for which it
is designed.
ELECTROCUTION HAZARDS
• Do NOT allow the inside of the RITE-POWER 615 to come into contact with water or
any other liquids.
• Ensure the RITE-POWER 615 is not being set up in a potentially explosive
environment – the RITE-POWER 615 is not an ATEX approved product.
• The RITE-POWER 615 is not designed to be submersed under water.
• Do NOT use if any parts become significantly damaged which may compromise the
IP rating of the product.
• Do NOT use if any damage to the sockets on the product occurs.
• If any significant damage occurs the RITE-POWER 615 must be returned to Ritelite
(systems) Ltd or one of its authorized dealers for repair.
• Do NOT use plugs or cables that are cut or damaged in any way.
• Do NOT connect the RITE-POWER 615 to any other mains supply system such as a
grid or generator supply, it is not designed for grid tie systems, it will damage the unit.
• Do NOT allow minors or persons of reduced competency to use the RITE-POWER
615, it is NOT a toy.
• Do NOT connect the RITE-POWER 615 charger between its charge input and mains
outlet sockets, it will damage the unit.
BODILY INJURY HAZARDS
• It is recommended that the user wears gloves whilst manoeuvring or connecting up
the RITE-POWER 615.
• In slippery or uneven terrain, it is recommended that two people manoeuvre the
product at all times.
• The RITE-POWER 615 is designed to be simple to operate by one person however
there may be situations where it is recommended that two people manoeuvre the
product.
• Do not manoeuvre the RITE-POWER 615 product for long distances in extreme
temperatures.
• Where possible the RITE-POWER 615 should be set up away from personnel or
moving vehicles.
• Be aware that the RITE-POWER 615 creates a mains electricity voltage and should
therefore be treated as the same potential hazard.

8
CRUSHING HAZARDS
• Ensure the RITE-POWER 615 is set up on a firm and horizontal flat surface.
• Keep hands and fingers away from any potential pinch points.
• Never place the RITE-POWER 615 above personnel where it could fall on them.
COLLISION HAZARDS
• Use common sense and planning when transporting/carrying the RITE-POWER 615
on any incline or slope.
• On slippery or uneven terrain, it is recommended that more care and thought is taken
for the conditions.
• Make sure when loading the RITE-POWER 615 into a vehicle or trolley that it is
securely mounted/retained so it cannot fall off or move in such away that it could
harm other items or personnel.
DAMAGED MACHINE HAZARDS
• Do NOT use a damaged RITE-POWER 615 or one that isn’t working properly.
• Conduct a thorough pre-operation inspection prior to each use.
• Be sure that all labels are in place and legible.
• Do NOT use if there are any visible damaged parts. Contact your original point of
purchase or Ritelite (Systems) Ltd to arrange for spares or repair options.
• Do NOT use any type of abrasive or strong chemicals to clean the RITE-POWER 615.
• Do NOT attempt to defeat / modify any of the wiring or protection fuses.
IMPROPER USE HAZARD
• Never leave an RITE-POWER 615 unattended unless a full risk assessment for
the application it is being used for has been undertaken by a competent person.
Unauthorized personnel could attempt to operate the RITE-POWER 615 without
proper instruction potentially causing injury to themselves or others.
• The RITE-POWER 615 is to be used only for its prescribed purpose. Any use other
than that mentioned is considered to be a case of misuse.
• The user/operator, and not the manufacturer shall be liable for any damage or injury
resulting from such cases of misuse.
• It is imperative to observe the local accident prevention regulations.
• The same applies for the general rules of occupational health and safety.
• The manufacturer is not liable for indirect consequential damage and financial loss.
• The manufacturer shall not be liable for any changes made to the device nor for any
damage resulting from such changes.
• The RITE-POWER 615 is not designed to be setup/used on a live public highway.

9
Section 3: TECHNICAL SPECIFICATIONS
PHYSICAL
Weight: 8.5Kg
Overall Dimensions: 39cm (w) 31cm (d) 17cm (h)
Case Material: Lightweight NK-7 resin
Impact Resistance: ATA Spec 300 Cat1
Colour: Graphite Grey
Protection Class: IP65 - (Subject to socket covers and product lid being closed and
latched accordingly).
Operating Ambient Temperature range: 0ºC - +30ºC
Recommended Storage Temperature: 0ºC to +25ºC
ELECTRICAL
Input 100-240v AC 50/60HZ 3A (depending on model selected) .
Charger requirements – 100-240V AC 50/60HZ – 140W Max
Inverter Output - 110V 60HZ 300W Max or 230V 50HZ 300W Max AC (depending on
model selected)
Output voltage tolerance +/- 5% THD < 3%
Efficiency > 90%
Power Factor 0.99
Mains input and output socket – (Depending on model selected) CEE 110V 16A 3P IP67
Socket (Model SLK310BP2/300/230/AMF100/TE-F)
or
CEE 230V 16A 3P IP67 Inlet/Outlet Socket (SLK310BP2/300/230/AMF100/T60309)
or
SCHUKO Input/Outlet SOCKET 250V 16A 3P IP68 -F (Model SLK310BP2/300/110/
AMF100/T60309)
CHARGING
In-built 6A 120W charging system that will recharge the battery from empty in 5-6 hours.
Charger requires mains cable connected to the input side of the RITE-POWER 615 with
an input voltage of between 100-240V AC. This allows the unit to recharge the battery
and at the same time allow a through feed of mains power to the outlet socket. Note - Do
not overload the outlet which should be restricted to 300W max continuous as per the
inverter’s maximum output.

10
Section 4: SETTING UP THE RITE-POWER 615
Inspect the proposed area for use.
An inspection of the proposed area in which to set up the RITE-POWER 615 is necessary
to ensure it is suitable for safe operation. This inspection should be performed by the
operator prior to using the RITE-POWER 615.
The area should be free from moving vehicles, machinery, pedestrians or other factors
which may mean the RITE-POWER 615 could form a hazard.
Set the RITE-POWER 615 up in such a way that it cannot obstruct walkways or areas that
form emergency exit routes.
Do not leave unattended if there is potential for minors or non-competent persons to
tamper with the RITE-POWER 615 whilst in use.
PROTECTION SYSTEMS AND FAULT SIGNALLING
• Short Circuit Protection – The RITE-POWER 615 will shut down until the fault is
removed, It will signal this by flashing the red LED continuously and a beeper will
be heard.
• Overload Protection – The RITE-POWER 615 will shut down until the load is reduced.
It will however allow small overloads up to 120% for short periods of time up to a
minute. It will signal this by flashing the red LED continuously 5 times which will then
be repeated and a beeper will be heard until the fault condition is removed.
• Over Temperature Protection – The RITE-POWER 615 will shut down until it has
cooled sufficiently to allow it to function again. It will signal this by flashing the red
LED continuously 4 times which will then be repeated and a beeper will be heard until
the fault condition is removed.
• Low Battery Capacity – The RITE-POWER 615 will eventually shut down until the
battery has been recharged sufficiently. It will signal this by flashing the red LED
continuously and a beeper will be heard until the fault condition is removed.
• Low Battery Capacity Shut Off – The RITE-POWER 615 has shutdown due to
insufficient battery capacity.
It will signal this by flashing the red LED continuously twice which will then be
repeated and a beeper will be heard until the fault condition is removed.
• Over Voltage Protection – The RITE-POWER 615 will shutdown if the voltage from the
battery/charger rises above a particular threshold, if this happens this would suggest
a permanent fault in the charging system and the issue should be investigated by a
competent person – please contact Ritelite (Systems) Ltd or its authorised distributor.
It will signal this by flashing the red LED continuously 3 times which will then be
repeated and a beeper will be heard until the fault condition is removed.
• Note in most cases the inverter will automatically reset itself after a fault
condition has been removed, in some cases it may be necessary to switch off
then back on the power switch to reset the unit.

11
Operators should be aware of the following possible hazardous situations. The
operator should also remember these hazards, watch and avoid them while moving,
setting up and operating the RITE-POWER 615.
• Forming a trip hazard
• Minors or non-competent persons
• Mains electricity at 110V AC or 230V AC (depending on model) is produced
by this unit.
• Debris either on proposed site or on route to site
• Inadequate surface support to withstand the RITE-POWER 615 weight
• Water which could allow the RITE-POWER 615 to be submersed
• All other possible unsafe conditions

12
Section 5: OPERATING INSTRUCTIONS
Do not use the RITE-POWER 615 for any purpose other than that for which it is designed –
as a portable power pack.
If more than one operator is expected to set up or use a RITE-POWER 615 at different
times, each operator is required to follow all safety rules and instructions in the operator’s
manual. That means every new operator should perform a pre-operation inspection and
function tests before using the unit.
5a) PRE-OPERATION INSPECTION
Always perform a pre-operation inspection.
The Pre-operation inspection is a visual inspection performed by the operator prior to
each use of the RITE-POWER 615. This inspection is designed to discover if anything is
obviously wrong with a unit prior to use.
A damaged or modified RITE-POWER 615 must never be used. If any damage is
discovered the RITE-POWER 615 must be removed from service until it has been repaired.
Maintenance and repairs can be executed only by authorised personnel. If any person
maintaining or repairing the device is in any doubt, they should contact their supplying
dealer or Ritelite (Systems) Ltd.
Check the following parts or areas for any signs of damage or missing parts.
• Cables (for kinks, frays, abrasions, bare conductors showing)
• Plugs and Sockets for physical damage
• Catches and locking mechanisms.
• Make sure the case is free from cracks or areas of damage where water could enter
• Make sure all labels and warnings are present and readable on the product as
detailed below.

13
5b) USING THE RITE-POWER 615
1. Check there is sufficient battery capacity for
the task in hand, this is indicated by the display
on the front of the unit showing the battery
capacity in a percentage, where 100% is full
capacity.
3. Make sure the RITE-POWER 615 is switched
off via the button next to the display. The
display will automatically light up when the unit
is switched on and go dark when the unit is
switched off to conserve power when not
in use.
4. Make connections to the mains output
socket at the side of the RITE-POWER 615.
Making sure the output voltage of the RITE-
POWER 615 is within the constraints of the
equipment to be powered from it.
2. If necessary, recharge the RITE-POWER 615.
As a point of note it is good practice to always
recharge the unit to full after every use.
Chose a suitable location, heeding the warnings in sections 4 & 5 of this manual.

14
5. Check the device to be powered is within the maximum constraints of the RITE-POWER 615, see
technical specifications contained within this manual and on the RITE-POWER 615. Heed the notes
in the section Applications and Restrictions of use with regard to Inductive, Resistive and capacitive
loads and their limitations.
6. Once everything is connected press the power
on button. The display will light up and a red LED
should light in the middle of the switch to indicate
that mains power is on and everything is ok.
7. Note the estimated run time on the display, this
will vary according to the load driven by
the RITE-POWER 615. In the example here the
display indicates 6 hours, 35 minutes remaining at
the current power drawn.
SYSTEM ENERGY MONITOR KEY
1. State of charge
2. Battery voltage (V)
3. Current draw (A)
4. Wattage (W)
5. Estimated run / recharge time
6. Battery capacity (Ah)
The display also shows various other parameters such as wattage, this can be a useful gauge to
understand what different powers are consumed by different equipment and the runtime that might
be expected.
6
5
4
3
2
1

15
10. Once the load has been switched off from
the depleted power pack the switch should be
pressed to switch the system off and the pack
placed on charge as soon as possible.
8. Certain equipment such as some lighting
can be dimmed, this can be useful to extend
the runtime required while still potentially
providing enough light for the task in hand.
9. In use note the fall of the battery capacity so
power isn’t suddenly lost unexpectedly. Once
the RITE-POWER 615 gets towards the end of
the available capacity a beeping will be heard
from the unit and the red LED in the middle of
the switch will flash to denote the low power
level, depending on the size of the load being
drawn will dictate how soon until the load is
then switched off.

16
5c) RECHARGING THE RITE-POWER 615
1. The RITE-POWER 615 should be placed on charge to return it to full capacity once used.
Choose a suitable location to recharge the unit away from any aforementioned hazards. Ideally the
RITE-POWER 615 should be charged in a cool ventilated environment.
Note – It is good practice to always keep the RITE-POWER generator fully charged up so it is always
ready for use.
2. Plug the RITE-POWER 615 into a suitable
outlet via its supplied mains cable.
3. After the mains has been connected the
charger will start and the back light on the
display on the RITE-POWER 615 will start to
pulse, energy will be shown flowing in.

17
5. Check the display on the RITE-POWER 615, once the charger is connected and everything is ok
the display will blink slowly as energy flows into the battery to recharge it. You can monitor progress
on the display, the capacity percentage will gradually rise as will the capacity in AH and the voltage.
The run time display will now show an estimated time to complete the charge process. You may
notice the energy go in slowly to start with, this depends on the state of discharge of the battery.
6. Once the display shows 100% the power pack is fully recharged, if not being used in mains pass
through or emergency mode the mains supply can be switched off and disconnected from the power
pack. Make sure the power pack is always switched off via the button next to the display when not in
use to prevent any unnecessary discharge.
ESTIMATED RECHARGE TIME
TO FULL 100%

18
5d) PACKING AWAY & TRANSPORT
In slippery or uneven terrain take care when carrying the RITE-POWER 615 seek help as required.
TRANSPORT AND LIFTING INSTRUCTIONS
• The transport vehicle/trolley must be parked on a level surface.
• The transport vehicle/trolley must be secured to prevent rolling while the RITE-
POWER 615 is being loaded.
• Be sure the vehicle/trolley capacity, loading surfaces/storage area and chains or
straps are sufficient to withstand the RITE-POWER 615 weight. See the data plate on
the RITE-POWER 615 components for their exact weight.
• The RITE-POWER 615 must be secured when transported in any vehicles with straps
of ample load capacity.
• The RITE-POWER 615 Must NOT be transported within the passenger area of
any vehicle.
• Observe the specific transport requirements and check the MSDS (Material Safety
Data Sheet) when transporting the product by vehicle. This is available online at the
following link: https://ritelite.co.uk/product-resources/rite-power/ or by scanning the
following QR code:
5e) STORAGE / TRANSPORT MODE
When planning to not use the RITE-POWER 615 make sure it is fully charged and the
power button is switched off so the unit doesn’t discharge unnecessarily in storage.
Check the unit every three months for its state of charge and recharge as required.
• Always store the unit in a secure location away from minors or persons of reduced
competency, it is NOT a toy.
• Always store in a cool, dry location.
At this link the SLK310BP2 MSDS covers all units in this manual.

19
Section 6: TROUBLESHOOTING
The following notes are here for help and guidance to get the best from your RITE-POWER
615. They describe possible errors/faults, what might cause them and how they
are rectified.
See page 12 for protection systems and fault signalling.
FAULT / ERROR SOLUTION
No mains output from the unit Check the mains connections and fuses to and from the RITE-POWER
615, check the equipment to be powered is switched on, checked the
equipment to be switched on works from another mains source
No mains output from the unit Check unit is switched on via switch on the front next to the display.
Display should be lit up to show system is on.
No mains output from the unit. Display
is lit up to show the system is on.
Check to see if the red LED is lit in the centre of the switch. If the red LED
is flashing continuously then check the capacity on the display shows
higher than 0%, it not, recharge the battery.
No mains output from the unit. Red
LED flashes continuously. There is
capacity in the battery.
Check the output isn’t short circuited – disconnect the mains output plug,
turn the RITE-POWER 615 off then on and check the red fault LED isn’t
flashing. Have repaired the cable/equipment causing the short circuit.
No mains output from the unit. Red
LED flashes 5 times. There is capacity
in the battery.
Check the output isn’t overloaded – disconnect the mains output plug or
reduce the load on the output, turn the RITE-POWER 615 off then on and
check the red fault LED isn’t flashing and mains power is restored.
No mains output from the unit. Red
LED flashes 4 times. There is capacity
in the battery.
Check the RITE-POWER 615 isn’t too hot – it will automatically shut
down if temperatures rise beyond the allowed thresholds of the inverter
contained within to protect from permanent damage. Once cooled the
RITE-POWER 615 will allow mains power to be restored. Switch the unit
off then on to reset it. Should the problem persist the RITE-POWER 615
should be moved to a cooler environment and/or the load should
be reduced.
No mains output from the unit. Note the RITE-POWER 615 has a mains pass through system with a
changeover relay. To check if mains inbound is present the LED indicator
lights on the charger inside the unit will light.
The display is blank, no red LED
flashing indicating a fault.
Check the RITE-POWER 615 isn’t over discharged, plug the unit in to the
mains to recover and recharge the battery.
The display is blank, no red LED
flashing indicating a fault.
Check the RITE-POWER 615 isn’t too hot or too cold– it will automatically
shut down if temperatures are beyond the allowed thresholds of the bat-
tery contained within to protect from permanent damage. Once within the
thresholds the RITE-POWER 615 will automatically reboot the system and
can be operated as normal. Should the problem persist the RITE-POWER
615 should be moved to a cooler or warmer environment as required.
Note: The battery should always be recharged fully after every use.
The system should always be powered off after every use via the button on the front of
the unit. Although the inverter will automatically shut down once a low battery voltage
is detected there is still a small parasitic load from the system which will eventually
discharge the battery in time if it’s not subsequently recharged.

20
FAULT / ERROR SOLUTION
The charger doesn’t appear to be
recharging the battery.
The charger lights are on (amber and green alternate flashing) but the
capacity display on the battery pack shows no energy going in to recharge
the battery. The most likely cause is the battery is too hot, this can be
due to high ambient temperatures or from just trying to recharge the unit
straight after heavy use when in high ambient temperatures. To rectify,
move unit to a cooler location or allow unit to cool and the system will
automatically start charging once temperatures around the battery have
fallen to below 40ºC. As temperature has a huge affect on the continued
performance, safety and longevity of the Lithium batteries contained
within your RITE-POWER 615 there are numerous protection systems
incorporated within the unit to make sure of its long and trouble free use.
Section 7: MAINTENANCE
• It is recommended that a regular inspection of the complete product is carried out
to look for signs of wear and tear and identify possible maintenance required. This
should be done by a competent person on at least an annual basis depending on
severity and types of use.
• It is recommended that gloves are worn during operation/setting up, breaking down,
cleaning and maintenance to protect the user.
• Never allow the inside of the RITE-POWER 615 to become wet, it will damage the
electronics and battery pack contained within. If any wetness is discovered the unit
must NOT be switched on under any circumstance and the manufacturer Ritelite
(Systems) Ltd or its authorised dealer must be contacted for guidance with regards
to repair.
• All fasteners, locking mechanisms and latches to be checked for correct operation
prior to use.
• Any damaged parts that could pose a risk to the user/personnel must be replaced.
• The RITE-POWER 615 must be taken out of service if, during use, or repair and
maintenance serious damage is discovered.
• The RITE-POWER 615 can only be put back into use after it has been properly
repaired and examined and signed off by authorised personnel.
• The use of spares other than original parts from Ritelite (Systems) Ltd will invalidate
any warranty.
Table of contents
Other Ritelite Portable Generator manuals
Popular Portable Generator manuals by other brands

iPower
iPower SUA2000I owner's manual

LONCIN
LONCIN LC1800D-F owner's manual

Generac Power Systems
Generac Power Systems TOWER LIGHT CUBE+ NEXT owner's manual

Briggs & Stratton
Briggs & Stratton 30205 Operator's manual

Swefog
Swefog Ultimate 3000DMX owner's manual

VYKING FORCE
VYKING FORCE VF2200IG instruction manual