RLH Industries 10/100 Ethernet Fiber Link Card System User manual

!RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com!Page 1
10/100 Ethernet
Fiber Link Card System
Environmentally hardened, substation grade
Description
The RLH 10/100 Ethernet Fiber Link Card system converts a
copper 10Base-T or 100Base-TX to a fiber optic 100Base-FX
transmission signal of either multimode or single-mode. The
cards transmit the data signals over fiber optic cable, allow for
network extension over long distances, and provide electrical
isolation between both ends of the network.
The Ethernet Fiber Link Card may be used as a complete
system, with a card at each end, or it may be connected
directly to any 100Base-FX device. The card includes Link
Fault Passthrough (LFP) mode with an LED indicator for link
loss failure that allows for rapid fault isolation.
This hardened, substation grade system is covered by our
Exclusive Unconditional Lifetime Warranty.
Note: The cards listed in this document replace all other
models. See the ordering section for part number information.
Key Features
• Ideal for critical, high voltage, remote or un-manned
locations that must remain operating 24/7/365
• Compatibility with IEEE 802.3 10 Base-T UTP, 100Base-TX,
and 100Base-FX Devices
• RJ45 UTP port with 10//100 auto-negotiation
• Extends network span up to 1.2 miles (2km) on multimode and
up to 74 miles (120km) on single-mode fiber
• Convenient LED status indicators
• Link alarm function for status monitoring
• Dual and Single (bi-directional) fiber models available
• Environmentally hardened to operate in -40°F to +158°F
(-40°C to +70°C) environments
• Standard RLH fiber link card form factor
•Covered by our Exclusive Unconditional Lifetime Warranty
U-016 2013B-1002
Specifications subject to change without notice.
RLH 10/100 Ethernet Fiber Link Card
&-) )
The leader in
rugged fiber optic
technology.
Unconditional
Lifetime Warranty
USER GUIDE
RLH Industries, Inc.
Contents
__________________________Description !1
__________________________Key Features!1
_________________General Safety Practices!2
_________________________Applications !3
___________________________Acronyms !4
__________________________Installation !4
____________________DIP Switch Settings !5
______________________Troubleshooting !6
_______________________LED Indicators !6
__________________Ordering Information !7
_________________________Specifications!8
___________________________Warranty !9
_____________________Technical Support !9

General Safety Practices
The equipment discussed in this document may require tools designed for the purpose being described.
RLH recommends that service personnel be familiar with the correct handling and use of any installation
equipment used, and follow all safety precautions including the use of protective personal equipment as
required.
Caution - Severe Shock Hazard
• Never install during a lightning storm or where unsafe high voltages are present.
• Use caution when handling copper wiring and follow appropriate safety regulations.
Special handling requirements
Be careful when handling electronic components
ATTENTION
ELECTROSTATIC
SENSITIVE
DEVICES
• This product contains static sensitive components.
• Handle Fiber Link cards at their edges only.
• Follow proper electrostatic discharge procedures.
This card utilizes circuitry that can be damaged by static electricity. When transporting the card, carry it in
an ESD safe container such as the antistatic bag provided with the card. Before handling cards, discharge
yourself of static electricity by physical bodily contact with earth ground. When handling cards, hold by
outer edges and avoid touching circuitry. Failure to follow ESD precautions may cause serious damage to
the card and prevent proper operation.
Guidelines for handling terminated fiber cable
• Do not bend fiber cable sharply. Use gradual and smooth bends to avoid damaging glass fiber.
• Keep dust caps on fiber optic connectors at all times when disconnected.
• Do not remove dust caps from unused fiber.
• Keep fiber ends and fiber connectors clean and free from dust, dirt and debris. Contamination will cause
signal loss.
• Do not touch fiber ends.
• Store excess fiber on housing spools or fiber spools at site
Page 2!!!RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com

Applications
Network equipment in high voltage areas can be at risk due to Ground Potential Rise (GPR). A copper
network cable referenced to a remote ground can become a path for high voltages during a ground fault.
Placement of all-dielectric fiber optic cable (instead of copper) completely eliminates the presence of a
remote ground, which dramatically increases safety of personnel and reliability of equipment. By utilizing
fiber optic cable, the Ethernet FIber Link Card provides absolute electrical isolation between both ends of
the network.
Copper twisted pair Ethernet is limited to 100m/328ft without extenders. Fiber optic cable provides long
distance service (up to 120km/74mi.) without any additional equipment. Fiber is immune to EMI/RF
interference, ground loops, and high voltage surges from lightning or ground faults, and is ideal in
electrically noisy environments such as near large power sources, electrical motors, and radio
communications equipment.
RLH Ethernet over
Fiber Card
24 - 56VDC Power Supply 24 - 56VDC Power Supply
RLH Ethernet over
Fiber Card
Network
or
Ethernet
Device
Network
or
Ethernet
Device
Ethernet Ethernet
Fiber Optic Cable
Up to 36mi. / 60km
Typical Ethernet System Diagram
1
O
N
23456
FDX
LP
MAN
10
HDX
HDX
ON
LS
AN
100
FDX
FDX
RST
DC POWER
24~56VDC
UTP 10/100
FXL
TDX FEFD
FSD
PWR
10/100 ETHERNET CARD MDL-02
TX
RX
Ethernet Fiber Link Card Front Panel
!RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com!Page 3

Acronyms
Commonly used acronyms and abbreviations
Acronym/Abbreviation
Description
UTP
Unshielded Twisted Pair (commonly used in Ethernet networks)
TP
Twisted Pair (same as UTP)
LFP
Link Fault Passthrough
TX
Transmit
RX
Receive
MAN
Manual
AN
Auto Negotiating
HDX
Half Duplex
FDX
Full Duplex
LS
Link Fault Passthrough Suspend
LP
Link Fault Passthrough Pass
Installation
Prior to installation:
• Check for shipping damage
• Check the contents to ensure correct model and fiber type
• Have a clean, dry installation environment ready
Required for installation:
•24-56VDC (3W minimum) power source
•RLH Fiber Link Card housing
Measure the DC voltage of the source power to ensure that it is 24-56VDC (3W minimum). All electrical
and fiber optic connection are made directly onto the card. The Ethernet fiber link card is designed to be
installed into any RLH card housing.
Connect fiber optic cable
Multimode and single-mode Ethernet cards are equipped with either two ST or SC female optical
connectors, or a single SC bi-directional connector. Connect fiber cable to the Transmit (TX) and Receive
(RX) optical connectors. The other end of the fiber may be connected to another Ethernet fiber link card
or any 100BASE-FX Ethernet device.
The TX connector of each card must be connected the RX connector at the other end. For bi-directional,
single fiber models, there is only a single SC connector used for both transmitting and receiving. Always
route fiber optic cable loosely avoiding tight bends.
Connect Ethernet cable
The TP (RJ-45) Ethernet port will auto-sense for 10Base-T or 100Base-TX connections.
The port is auto MDI/MDIX, which means that the card can connect to another card, switch or
workstation without changing straight through or crossover cabling.
Page 4!!!RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com

Connect Power
Connect a 24-56VDC (200mA minimum) power source to the screw-down terminal on the Ethernet card.
The power input is not polarity sensitive. The terminal unplugs from the card to make wiring easier.
DIP Switch Settings
The front panel DIP switches may be set for optional modes. The factory default is ON for all switches.
Ethernet DIP Switch Settings
ON
1 2 3 4 5 6
O
N
LP
MAN
10
HDX
HDX
ON
LS
AN
100
FDX
FDX
RST
Switch
Description
Setting
Function
1
1
2
2
3
3
4
4
5
5
6
6
Link Fault Pass-through
LP
LFP enabled (Default)
Link Fault Pass-through
LS
LFP disabled
TP Port Mode
AN
TP is auto negotiating (Default)
TP Port Mode
MAN
Force TP at 10M or half duplex
TP Port Speed
100
TP at 100M (Default)
TP Port Speed
10
TP at 10M when TP Port Mode is set to MAN (Force 10M)
TP Port Duplex
FDX
TP at full duplex (Default)
TP Port Duplex
HDX
TP at half duplex when Port Mode at Force
Fiber Port Duplex
FDX
Fiber port at full duplex (Default)
Fiber Port Duplex
HDX
Fiber port at half duplex
Reset
ON
Power on (Default)
Reset
RST
Recycle power (See note)
After changing any of the DIP switches, recycle the power to the card by flipping switch 6 (Reset) from ON to RST then
back to ON.
DIP switch 2 must be set to MAN when switches 3 and 4 are set to 10 and HDX respectively.
Note: Connecting an auto-negotiating device to a non-auto-negotiating device may result in an
unpredictable port setting with poor link performance. When operating in Manual mode, both mating ports
must be set to the same data rate and duplex mode.
!RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com!Page 5

Troubleshooting
If trouble is encountered, verify all copper and fiber connections and settings. If any of the DIP switches
were changed, you must recycle the power by flipping switch 6 to RST (Reset) and ON again to enable
the settings. Refer to the LED Indicators on the front panel, they show availability of power, modes of
operation, and data being received by the fiber and TP port.
1
O
N
23456
FDX
LP
MAN
10
HDX
HDX
ON
LS
AN
100
FDX
FDX
RST
DC POWER
24~56VDC
UTP 10/100
FXL
TDX FEFD
FSD
PWR
10/100 ETHERNET CARD MDL-02
TX
RX
1
O
N
23456
FDX
LP
MAN
10
HDX
HDX
ON
LS
AN
100
FDX
FDX
RST
DC POWER
24~56VDC
UTP 10/100
FXL
TDX FEFD
FSD
PWR
10/100 ETHERNET CARD MDL-02
TX
RX
1
O
N
23456
FDX
LP
MAN
10
HDX
HDX
ON
LS
AN
100
FDX
FDX
RST
DC POWER
24~56VDC
UTP 10/100
FXL
TDX FEFD
FSD
PWR
10/100 ETHERNET CARD MDL-02
TX
RX
10/100
LINK/ACT
Indicator
Color
LED
Description
FXL
GRN
FXL
GRN
FXL
GRN
FDX
GRN
FDX
GRN
FDX
GRN
FSD
GRN
FSD
GRN
FEFD
GRN
FEFD
GRN
TDX
GRN
TDX
GRN
TDX
GRN
PWR
GRN
PWR
GRN
10/100
ORG
10/100
ORG
LINK/ACT
GRN
LINK/ACT
GRN
LINK/ACT
GRN
ON
Fiber port link OK
Blinking
Fiber port link OK and activity is present
OFF
Fiber port link fail
ON
Fiber port at full duplex
OFF
Fiber port at half duplex
Blinking
Fiber port at half duplex and collisions occurring
ON
Fiber signal detected
OFF
Fiber disconnected
OFF
Normal operation
Blinking
Far end fault detected
ON
TP port at full duplex
OFF
TP port at half duplex
Blinking
TP port at half duplex and collisions occurring
ON
Card power is ON
OFF
Card power is OFF
ON
TP port speed is 100M
OFF
TP port speed is 10M
ON
TP port link OK
Blinking
TP port link OK and activity is present
OFF
TP port link not present
If trouble persists, replace the unit and retest. If technical assistance is required, contact the RLH
technical support department:
800-877-1672 (6 am to 6 pm- PST),
or call our 24/7 Technical/Customer Service: (714) 366-2503 or (714) 457-5740
Page 6!!!RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com

Ordering Information
10/100 Ethernet Fiber Link Card
Part Number
Side
Distance
Wavelength
Fiber
Part Number
Multimode
ST
-
2 km/1.2 mi
1310 nm
62.5 μm
EF4-04-2
Multimode
ST
-
2 km/1.2 mi
850 nm
62.5 μm
EF4-07-2
Multimode
SC
-
2 km/1.2 mi
1310 nm
62.5 μm
EF4-03-2
Multimode
SC
-
2 km/1.2 mi
850 nm
62.5 μm
EF4-06-2
Bi-Directional
Multimode SC
A
2 km/1.2 mi
Tx 1310 nm / Rx 1550 nm
62.5 μm
EF4-01-2
Bi-Directional
Multimode SC
B
2 km/1.2 mi
Tx 1550 nm / Rx 1310 nm
62.5 μm
EF4-02-2
Single-mode
ST
-
20km/12.4mi.
1310 nm
8~9 μm
EF4-50-2
Single-mode
ST
-
60km / 37mi.
1310 nm
8~9 μm
EF4-51-2
Single-mode
ST
-
120km / 74 mi.
1310 nm
8~9 μm
EF4-52-2
Single-mode
ST
-
60km / 37mi.
1550 nm
8~9 μm
EF4-54-2
Single-mode
ST
-
120km / 74 mi.
1550 nm
8~9 μm
EF4-55-2
Single-mode
SC
-
20km/12.4mi.
1310 nm
8~9 μm
EF4-40-2
Single-mode
SC
-
60km / 37mi.
1310 nm
8~9 μm
EF4-41-2
Single-mode
SC
-
120km / 74 mi.
1310 nm
8~9 μm
EF4-42-2
Single-mode
SC
-
60km / 37mi.
1550 nm
8~9 μm
EF4-44-2
Single-mode
SC
-
120km / 74 mi.
1550 nm
8~9 μm
EF4-45-2
Bi-Directional
Single-mode
SC
A
20km/12.4mi.
Tx 1310 nm / Rx 1550 nm
8~9 μm
EF4-10-2
Bi-Directional
Single-mode
SC
B
20km/12.4mi.
Tx 1550 nm / Rx 1310 nm
8~9 μm
EF4-11-2
Bi-Directional
Single-mode
SC
A
60km / 37mi.
Tx 1310 nm / Rx 1550 nm
8~9 μm
EF4-14-2
Bi-Directional
Single-mode
SC
B
60km / 37mi.
Tx 1550 nm / Rx 1310 nm
8~9 μm
EF4-15-2
Optics are dual fiber unless connectors are Bi-Di.
Bidirectional single fiber models require both an A Side and B Side unit for a complete system.
Please contact your RLH sales representative for pricing and delivery information.
!RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com!Page 7

General Specifications
Protocols
100BASE-FX, 10BASE-T, or 100BASE-TX
100BASE-FX, 10BASE-T, or 100BASE-TX
100BASE-FX, 10BASE-T, or 100BASE-TX
100BASE-FX, 10BASE-T, or 100BASE-TX
100BASE-FX, 10BASE-T, or 100BASE-TX
Copper
Connector
RJ45 UTP
RJ45 UTP
RJ45 UTP
RJ45 UTP
RJ45 UTP
Copper Distance
100m / 328 feet
100m / 328 feet
100m / 328 feet
100m / 328 feet
100m / 328 feet
Fiber Connector
ST, SC or FC
ST, SC or FC
ST, SC or FC
ST, SC or FC
ST, SC or FC
Fiber Connector
Dual fiber or single fiber (bi-directional) connectors
Dual fiber or single fiber (bi-directional) connectors
Dual fiber or single fiber (bi-directional) connectors
Dual fiber or single fiber (bi-directional) connectors
Dual fiber or single fiber (bi-directional) connectors
Dual Fiber Optics
Fiber Type
Multimode
Single-mode
Single-mode
Single-mode
Dual Fiber Optics
Wavelength TX/RX (nm)
1310
1310
1310
1310
Dual Fiber Optics
Distance
2km / 1.2 mi.
20km / 12 mi.
60km / 36 mi.
120km / 74 mi.
Dual Fiber Optics
Min. TX PWR (dBm)
-18
-15
-6
0
Dual Fiber Optics
Max. TX PWR (dBm)
-10
-8
-3
+5
Dual Fiber Optics
RX Sensitivity (dBm)
-31
-34
-34
-34
Dual Fiber Optics
Link Loss Budget (dBm)
13
19
28
34
Single Fiber
Optics
(Bi-directional)
Fiber Type
Multimode
Single-mode
Single-mode
Single-mode
Single Fiber
Optics
(Bi-directional)
Wavelength (nm)
1310/1550
1310/1550
1310/1550
-
Single Fiber
Optics
(Bi-directional)
Distance
2km / 1.2 mi.
20km / 12 mi.
60km / 36 mi.
-
Single Fiber
Optics
(Bi-directional)
Min. TX PWR (dBm)
2-17
-14
-9
-
Single Fiber
Optics
(Bi-directional)
Max. TX PWR (dBm)
-10
-8
-5
-
Single Fiber
Optics
(Bi-directional)
RX Sensitivity (dBm)
-31
-34
-34
-
Single Fiber
Optics
(Bi-directional)
Link Loss Budget (dBm)
14
20
25
-
LED Indicators
FXL (Fiber)
Fiber port link - ON: link OK, OFF: link fail, Blink: activity
Fiber port link - ON: link OK, OFF: link fail, Blink: activity
Fiber port link - ON: link OK, OFF: link fail, Blink: activity
Fiber port link - ON: link OK, OFF: link fail, Blink: activity
LED Indicators
FDX (Fiber)
Fiber port full duplex - ON: full, OFF: half, Blink: half & collisions
Fiber port full duplex - ON: full, OFF: half, Blink: half & collisions
Fiber port full duplex - ON: full, OFF: half, Blink: half & collisions
Fiber port full duplex - ON: full, OFF: half, Blink: half & collisions
LED Indicators
FSD
Fiber signal detect - ON: signal detected, OFF: fiber disconnected
Fiber signal detect - ON: signal detected, OFF: fiber disconnected
Fiber signal detect - ON: signal detected, OFF: fiber disconnected
Fiber signal detect - ON: signal detected, OFF: fiber disconnected
LED Indicators
FEFD
Far end fault detection - OFF: normal operation, Blinking: far end fault
detected
Far end fault detection - OFF: normal operation, Blinking: far end fault
detected
Far end fault detection - OFF: normal operation, Blinking: far end fault
detected
Far end fault detection - OFF: normal operation, Blinking: far end fault
detected
LED Indicators
TDX
TP port full duplex - ON: full, OFF: half, Blink: half & collisions
TP port full duplex - ON: full, OFF: half, Blink: half & collisions
TP port full duplex - ON: full, OFF: half, Blink: half & collisions
TP port full duplex - ON: full, OFF: half, Blink: half & collisions
LED Indicators
PWR
Power - ON: power applied, OFF: no power
Power - ON: power applied, OFF: no power
Power - ON: power applied, OFF: no power
Power - ON: power applied, OFF: no power
LED Indicators
10/100
TP port speed - ON: 100m, OFF: 10M
TP port speed - ON: 100m, OFF: 10M
TP port speed - ON: 100m, OFF: 10M
TP port speed - ON: 100m, OFF: 10M
LED Indicators
LINK/ACT
TP port link - ON: link OK, OFF: no link, Blink: activity
TP port link - ON: link OK, OFF: no link, Blink: activity
TP port link - ON: link OK, OFF: no link, Blink: activity
TP port link - ON: link OK, OFF: no link, Blink: activity
Power Input
24~56VDC @ 3W
24~56VDC @ 3W
24~56VDC @ 3W
24~56VDC @ 3W
24~56VDC @ 3W
Dimensions
7.0” x 4.0” x 1.0”
7.0” x 4.0” x 1.0”
7.0” x 4.0” x 1.0”
7.0” x 4.0” x 1.0”
7.0” x 4.0” x 1.0”
Temperature
Operating
-40˚F to +158˚F (-40˚C to +70˚C)
-40˚F to +158˚F (-40˚C to +70˚C)
-40˚F to +158˚F (-40˚C to +70˚C)
-40˚F to +158˚F (-40˚C to +70˚C)
Temperature
Storage
-40˚F to +176˚F (-40˚C to +80˚C)
-40˚F to +176˚F (-40˚C to +80˚C)
-40˚F to +176˚F (-40˚C to +80˚C)
-40˚F to +176˚F (-40˚C to +80˚C)
Humidity
5~95% non-condensing
5~95% non-condensing
5~95% non-condensing
5~95% non-condensing
5~95% non-condensing
Specifications subject to change without notice.
Page 8!!!RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com

Warranty
This product is covered by our UNCONDITIONAL LIFETIME WARRANTY. RLH is
recognized throughout the U.S. and offers the only warranty of its kind in the
telecommunications industry. We are very proud of our warranty which simply states
that our transmission products are guaranteed to be free of defects in material and
workmanship for the LIFE OF THE PRODUCT. Look for the warranty badge.
We can offer this warranty because:
•We believe our customers shouldn't have to incur additional costs due to failure or damage.
•We engineer and manufacture our Fiber Link Cards in the USA, with total confidence in our quality.
•We understand how safety and reliability have an impact on the total cost of ownership.
•We know that customer support extends beyond the initial sale, so we stand behind our products.
RLH will replace these products or components that fail FOR ANY REASON. This warranty is
UNCONDITIONAL and valid even when products have been abused or mishandled, when unauthorized
repairs have been attempted or performed, or damaged as a result of a natural disaster. Compare this
warranty to our competitors and it becomes clear how RLH products will reduce your costs and simplify
your maintenance activities.
To make a warranty claim, or schedule repair or replacement of your RLH product, contact us for an RMA
number. You will be promptly assisted by one of our warranty specialists. An RMA number is required
before we can receive any items.
Technical Support
Email:
support@fiberopticlink.com
24/7 technical support:
Toll Free 1-855-RLH-24X7
Toll Free 1-855-754-2497
Contact Information
Corporate Headquarters:
RLH Industries, Inc.
936 N. Main Street
Orange, CA 92867 USA
Phone:
(714) 532-1672
Toll Free 1-800-877-1672
Toll Free 1-866-DO-FIBER
Fax:
(714) 532-1885
Email:
info@fiberopticlink.com
Web site:
www.fiberopticlink.com
!RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com!Page 9

RLH Industries, Inc.
6/$0/%*5*0/"--*'&5*.&8"33"/5:
."%&*/64"
RLH INDUSTRIES, INC. FIBER OPTIC LINK products are warranted to be free of defects in materials and workmanship
for the LIFE OF THE PRODUCT. This lifetime warranty is effective for RLH fiber optic link products sold since the date
RLH was founded, February 2, 1988, with the exception of fiber cable products which are warranted to free of defects
in manufacturing, and batteries which carry a 10-year unconditional replacement warranty.
RLH Industries, Inc. will repair or replace these products that fail FOR ANY REASON, provided the defective part is
returned to RLH freight prepaid.
This warranty is UNCONDITIONAL and valid even when products have been abused or mishandled, when unauthorized
repairs have been attempted or performed, or damaged as a result of a natural disaster.
Authorized by:
J. RANDALL MEARS, Vice President, Engineering
RLH Industries, Inc.
936 N. Main Street, Orange, CA 92867 USA
T: (714) 532-1672
F: (714) 532-1885
Please contact your RLH sales representative for
pricing and delivery information.
Specifications subject to change without notice.
Page 10!!!RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com
Table of contents