RMG RMG 790 User manual

SERVING THE GAS INDUSTRY WORLDWIDE
RMG REGEL + MESSTECHNIK GMBH
Operating Manual
TESTING DEVICE FOR WATER - RMG 790

2
TESTING DEVICE FOR WATER - RMG 790
A
E
3
1
2
4
5
6
7 8
9
10
C
D
B
Operating Manual
Water
Gas
100 bar 16 bar

3
TESTING DEVICE FOR WATER SAV RMG 790
CONNECTION: TO: TYPE OF CONNECTION:
A Gas – Inlet Auxiliary energy, gas
Pipe connection DIN 2353light-duty seriesouter
diameter of pipes
B Gas – Outlet Outdoor line
C Water – Outlet Heat exchanger
D Water – Inlet Funnel Quick coupling
E Water – Overowvalve Collector Hosenipple12mmwithcock
COMPONENTS:
1 Pressure vessel
2Funnelwithquickcoupling
3 Gas stop ball valve at inlet
4 Water stop ball valve at outlet
5 Adjustable inlet control valve
6 Adjustable outlet control valve
7 Fixed control valve
8Safetyblow-ovalve,setto12bar
9 Pressure gauge, gas
10
Pressuregauge,water
TECHNICAL SPECIFICATIONS:
Inlet pressure, max.: pe max = 100 bar
Operating pressure, max.: pe max = 16 bar
Water tank: V ~ 6.5
Operating Manual

4
TESTING DEVICE FOR WATER - RMG 790
•ClosestopvalvesbetweenheatingandRMG790inowandreturnpipes.
•ConnectwateroutletconnectionCofthetestingdevicetotestconnectionI(heatexchangerside!)ofanRMG
790 or directly to the heat exchanger.
•Openstopballvalve4.Compensatepressurebetweenheatexchangerandtestingdevice.
•Observewaterpressuregauge10 .
Caution. Tank1isunderpressure!DonotopenconnectionDbyinsertingwaterfunnel2.
Operating Manual
1. Filling with water
Caution. Depending on application, it may be necessary to use antifreeze or similar agents.
•Insertfunnel2withquickcoupling.ConnectionDisopen.
•Openoutletcontrolvalve6.
•Closestopballvalves3and4.
•OpenoverowvalveEabit.(Releaseairwhenllingpressurevessel1.)
•Fillwithwater.
•Removefunnel2,connectionDisclosed.
•CloseoverowvalveE.
2. Connect to SAV RMG 790 or heat exchanger
It is also possible
to connect di-
rectly to the heat
exchanger.
Heat exchanger
Flowpipes
Return
pipes Stop valve
Stop valve
Test connection I
Test connection II
Test connection II Test connection I
Test connection

5
TESTING DEVICE FOR WATER SAV RMG 790
4. Connect auxiliary energy (gas).
•Closestopballvalve3.
•Closeoutletcontrolvalve5.
•Openoutletcontrolvalve6.
•Connectauxiliaryenergy.(ph> ps SAV)
5. Testing
•Openstopballvalve3.
•Adjusttestpressureadjustingcontrolvalves5and6.
By applying the test pressure to the pressure vessel on the gas side, the pressure in the heat exchanger is raised
simultaneouslysothatthetestingdeviceonRMG790opensassoonasthesetvalueisreached.Youwillnoticea
smallamountofwaterleakingfromthetestingdevice.
AfurtherincreaseinthepressurewillclosetheSAVs.ThepressureatthepressuregaugeofSAVtestconnectionII
willfallbacktothesetvalueofthetestingdevice.Next,youmustraisethetestpressureanadditional2to3bars
(butnotbeyond10bar).Trapthepressureintheheatexchangerbyclosingtheconnectionofthetestingdevice.If
thepressureremainsstable,theconnectionistightandtheRMG790worksproperly.
•Whileapplyingthepressureandcarryingoutthetest,keepaneyeonpressuregauges9(gas)and10(water)on
the testing device. Both pressure gauges must indicate the same pressure.
6. Completing the test
•Closestopballvalve3.
•Openoutletcontrolvalve6.Reducegaspressure.
•Closestopballvalve4.
•OpenoverowvalveE.Reducewaterpressure.
•Removetestingdeviceconnection.
•Drainingthewaterfromtestingdevice:
Openstopballvalve4anddrainpressurevessel1usingwateroverowconnectionE.
Rememberantifreeze,ifnecessary(collector).
Operating Manual
3. Connect outlet connection B to outdoor pipe.

SERVING THE GAS INDUSTRY WORLDWIDE
WWW.RMG.COM
RMGisyourworldwidepartnerforgascontrolequipment,
ranging from exploration to consumer supply. The com-
prehensiverangeofRMGproductsandsystemsprovides
youwithatotalsolutionforallyourgasandmeasurement
needs.Modernmanufacturingtechniquescombinedwith
ourexpertiseandspecialistknowledgeinthedesignand
buildofgascontrolequipment,includingfullyautomated
stations,hasearnedRMGaworldwidereputationforsup-
plyofsave,accurateandreliableequipment.
RMG…Welcomestheopportunitytomeetyourbusiness
requirements.
Lastupdate11/2007TestingdeviceforSAVRMG790Technicalmodicationsreserved
WÄGAWÄRME-GASTECHNIKGMBH
Osterholzstraße 45
D-34123Kassel(Germany)
Tel +49(0)561.5007-0
Fax+49(0)561.5007-207
RMG-GASELANREGEL+MESSTECHNIKGMBH
Julius-Pintsch-Ring3
D-15517Fürstenwalde(Germany)
Tel +49(0)3361.356-60
Fax+49(0)3361.356-836
CANADA
BRYANDONKINRMGCANADALTD.
50 Clarke Street South, Woodstock
Ontario N4S 7Y5, Canada
Tel +1. 519 53 98 531
Fax +1. 519 53 73 339
GERMANY
RMGREGEL+MESSTECHNIKGMBH
Osterholzstraße 45
D-34123Kassel(Germany)
Tel +49(0)561.5007-0
Fax+49(0)561.5007-107
RMGMESSTECHNIKGMBH
Otto-Hahn-Straße 5
D-35510Butzbach(Germany)
Tel +49(0)6033.897-0
Fax+49(0)6033.897-130
Ebersberg location:
-Softwaredevelopment-
Anzinger Straße 5
D-85560Ebersberg(Germany)
Tel +49(0)8092.2097-0
Fax+49(0)8092.2097-10
ENGLAND
BRYANDONKINRMGGASCONTROLSLTD.
EnterpriseDrive,Holmewood
ChestereldS425UZ,England
Tel +44. 12 46 501-501
Fax +44. 12 46 501-500
POLAND
GAZOMETSP.ZO.O.
ul.Sarnowska2
63-900Rawicz,Poland
Tel +48. 65 546 24 01
Fax +48. 65 546 24 08
Table of contents