MODEL FC-48H-PLC
Plus
PlusPlus
Plus
P/N 121-690
Listed, File No. E183233
Input: 240 VAC
50/60 HZ.
Output: 0-240 VAC
Single Unit Fuse Size: 15 AMPS
80% Duty Cycle at Rated AMPS
© 2000 RODIX
INC.
..
.
1. SELECTING 60 OR 120 PULSE
OPERATION
A. For 60 pulse output - Set switch (S1) to 60 on
"master control" P.C. card (No. 24-489).
B. For 120 pulse output - Set switch (S1) to 120 on
"master control" P.C. card.
Note: Readjust MAX pot after changing pulse
switch setting.
2. LIMITING THE MAXIMUM
OUTPUT OF CONTROL
Adjust the MAX Output trimpot so that the output to
the feeder reaches its desired maximum level when
the MAIN CONTROL DIAL is turned fully clockwise.
The MAX Output trimpot should be adjusted to keep
the vibratory feeder from hammering when thecontrol
is turned up to full power.
NOTE: Output to feeder must be connected and
the control set for proper output frequency(60 or
120 pulse) setting. The Run Jumper must be
connected as shown on the wiring diagram.
A. Power input should be OFF or disconnected.
B. Rotate MAIN CONTROL DIAL onfront cover to0
or its minimum setting.
C. Open cover to allow access to printed circuit
card.
D. Using CAUTION, turn power ON (no output
should be present).
E. Rotate the MAIN CONTROL DIAL on front cover
slowly to its highest setting.
F. Adjust the MAX Output trimpot so that the output
to the feeder reaches its desired maximum level
when the MAIN CONTROL DIAL is turned fully
clockwise. Turning the MAX Output trimpot
clockwise increases the maximum output
level.
3. REMOTE OFF/ON CONTROL
Note: a Run Jumper has been installed at the
factory as shown on the enclosed wiring diagram.
Remote OFF/ON operation of the FC-40
Plus
PlusPlus
Plus
Series
SeriesSeries
Series
Feeder Cube®control can be configured
to operate in one of the following ways.
A. A low current switch such as a paddle switch
can replace the factory-installed Run jumper
"J1." The "Run Contact" connects to
terminals 6 and 7. The contact must be able
to switch 5VDC and 2mA. The control will
then run only when the contact is closed.
Refer to Section A of the OFF/ON CONTROL
GUIDE.
B. Feeder Bowl/Hopper Interlock allows the
Hopper control to operate onlywhen the Bowl
is running and the paddle switch contact is
closed. The interlock input on terminals 11
and 12 of TB2 is controlled by the interlock
output of a "Parts Sensing Feeder Bowl
Control" such as an FC-90 Plus
PlusPlus
Plus.
Remove jumper "J1" of this control from
terminals 6 and 7. Connect the Hopper
Paddle switch to alternate terminals 5 and 6.
Connect TB2 terminals 11 and 12 of this
control to the "Parts Sensing Control". Refer
to Section B of the OFF/ON CONTROL
GUIDE. Check specific instructions for the
"Parts Sensing Control" wiring.
Note: Only use the Bowl/Hopper Interlock with
a FC-90 and FC-40 Series control. Two FC-
40 Series controls will not interlock to each
other since neither one has an interlock
output.
48h-plc.doc 9/28/2009
RODIX INC.
FEEDER CUBE


FC-40
Plus Series
Plus SeriesPlus Series
Plus Series
OIL RESISTANT
ADJUSTMENTS AND
SET UP



C. Low Voltage DC can be used to turn the
control ON and OFF. Move jumper "J1" from
terminal 7, to terminal 5, (6 remains the
same).
Connect a +5 to 30VDC (10mA) signal to
terminal 12 and the reference (GND) to
terminal 11 of TB2. The control will now turn
ON when the DC signal is present at terminals
11 and 12 of TB2. This input is optically
isolated. Refer to Section C of the OFF/ON
CONTROL GUIDE.
D. AC Voltage may be used to turn the control
ON and OFF. This requires a 105-250VAC
signal, with 2mA leakage maximum. Set up
the control by moving the jumper "J1" from
terminal 7, to terminal 5, (6 remains the
same). Connect the 105-250VAC Signal to
terminal 12 (L1) and the common (L2) to
terminal 10 of TB2. The FC-40 control will
now turn ON whenever the AC signal is
applied to terminals 10 and 12 of TB2. This
input is optically isolated. Refer to Section D
of the OFF/ON CONTROL GUIDE.
TB-2 terminals 5-7 are transformer isolated from
the line voltage circuit.
4. MAIN CONTROL DIAL
The output power is controlled by the MAIN
CONTROL DIAL. A special logarithmic-tapered
power out curve (non-linear) spreads the power
broadly across the MAIN CONTROL DIAL to help
give maximum "Fine Control" over the output
speed of the vibratory feeder.
5. SETTING THE SOFT-START
The start-up of the control output can be adjusted
to ramp up to the desired output level instead of
starting abruptly. This keeps parts from falling off
the tooling of a vibratory feeder when it turns on; it
can reduce hammering during turn on; it can also
simulate a paddle switch ON delay. Adjust the
SOFT Start trimpot clockwise for the gentlest start
(about a 10-second ramp up to full output). Turn
the trimpot fully counter-clockwise for no softstart.
6. LINE VOLTAGE COMPENSATION
Fluctuations in the line Voltage can cause a feeder
bowl to vary its feed rate. The line voltage
compensation feature adjusts the control's output to
help compensate for fluctuations in the supply
voltage. If it becomes necessary to disable this
feature, remove resistor R4 from the bottom of the
board with a pair of pliers, twist R4 to snap it off.
7. REMOTE SPEED CONTROL
Remote control of the power signal level can be
accomplished by the following methods:
A. 0-5VDC Analog input signal may be applied in
place of the Main Control Dial. For further
information, contact RODIX.
B. 4-20mA signal from a PLC can be used to
remotely vary the output of the control instead of
the Main Control Dial. This feature is automatically
turned on whenever a 4-20mA signal is applied to
the control. To return control to the Main Control
Dial, remove the 4-20mA signal by turning it off or
use a switch to open the circuit. The 4-20mAinput
is transformer isolated from the power line.
C. Remote control of the output power level can be
accomplished by using an optionalStep Up/Down
Remote Speed Interface P/N 123-148.
WARNING:
Fuses should be replaced with Littelfuse 3AB
"Fast Acting" type or equivalent of manufacturer's
original value.
Mounting this control on a vibrating surface will
void the warranty.
WARRANTY
Rodix Control Products are Warranted to be free
from defects in material and workmanship under
normal use for a period of two years from date of
shipment. For the full description of the warranty,
terms, and software license, please contact the
factory.
For assistance installing or operating your Rodix
Control please call the factory. Technical help is
available to answer your questions and Fax any
needed information. To return a control for IN or
OUT of Warranty Service, please ship it prepaid
to: Rodix Inc., ATTN: Repair Department
If under Warranty,Rodix will repair or replace your
control at no charge; If out of Warranty, we will
repair it and you will be billed for the repair charges
(Time and Material) plus the return freight. Quotes
for repairs are available upon request. A brief note
describing the symptoms is appreciated by our
Technicians.
Feeder Cube®is a registered TM of Rodix Inc.
DIMENSIONS
RODIX, INC.
2316 23rd Avenue, Rockford, IL 61104
Toll Free (800) 562-1868
E-mail custserv[email protected]
FAX (815) 316-4701
www.rodix.com
48h-plc.doc 9/28/2009
RODIX FEEDER CUBE
RODIX INC. ROCKFORD IL 61104-7337
FC-40
Plus Series
Plus SeriesPlus Series
Plus Series
APPLICATION NOTE
OIL RESISTANT MODEL
RODIX INC.
FEEDER CUBE


FC-48H-PLC
Plus
PlusPlus
Plus
ALL PURPOSE
OIL RESISTANT MODEL
IMPORTANT: APPLICATION NOTE
MODEL INPUT VAC AMPS OUTPUT
FC-48H-PLC PLUS 240VAC 15A 0-240
FC48H plc.doc 4/29/2005 page 3



Customer supplied wiring
is shown by dashed lines
C)
SWITCH
7
L1
10
2
J1
10
5
11
1
6
10
OFF/ON CONTROL
7
7
See section 3 of the Application Note for more
details
L2
11 9
5-30 VDC INPUT VOLTAGE
5
12
5
8
OFF/ON CONTROL
LOW CURRENT
SWITCH
6
11
9
4
A)
FEEDER BOWL/HOPPER INTERLOCK
FC-40 PLUS SERIES TERM STRIP TB-2, INPUT
-
4
10
FC-40 PLUS SERIES TERM STRIP TB-2
7
7
OFF/ON CONTROL GUIDE
6
3
AC VOLTAGE INPUT SWITCHING
TERM STRIP TB-2, OUTPUT
5
5
FC-90 PLUS SERIES
8
12
4
98
B)
4
105-250 VAC INPUT VOLTAGE
FC-40 PLUS SERIES TERM STRIP TB-2
6
12
5
6
11
+
56
7
7
5
6
LOW VOLTAGE INPUT SWITCHING
9
D)
7
FC-40 PLUS SERIES TERM STRIP TB-2
J1
8
12
PADDLE
6
MAIN TERM
STRIP
TRIAC REFERENCE GUIDE
A2
A1 GATE
CONTROL CARD
-
4
120
TB1
A2
-
MAX
J1
MAIN
7
L1
TRIAC
12 10
43
VDC:
6 7
FC-40-PLC PLUS
-
1/8W MIN
100K
VAC:
(TALL)
4-20mA
6
A1
TERM. STRIP
6
INTERLOCK
2
TB2
(SMALL)
11
G
8
AUX FEATURE
11
cw
7
GND
TB2
CONTROL
9
POT
60
TB1
LOAD
1
P/N 24-489
10
1
S1
LINE VOLTAGE
GND
MAIN TERMINAL
5
GATE
TERM. STRIP
L2
POWER
OUTPUT POWER
SIG
5
+
J1
L1
L1 L2
+
8
Transformer
L2
L1 +
CHASSIS
L2
12
INPUT
INPUT POWER
9
3
2
1
5
SOFT
Torque to 9 in. lbs.
RODIX SOLUTION
Good wiring practices for
avoiding electrical noise
problems.
Rodix controls have been designed with a
high degree of immunity to electrical
noise; however, depending on the control
installation, electrical noise can cause
problems. These problems occur in less
than 1% of the product installations. Most
electrical noise problems can be avoided
by following some simple guidelines.
Good wiring practices need to be used to
prevent electrical noise from interfering
with your control’s operation. Another
name for electrical noise is Electro-
Magnetic Interference (EMI).
Symptoms of Electrical Noise
The symptoms of electrical noise would
appear as follows: a brief pause or a brief
“bump” in the vibratory feeder’s output
that the control automatically recovers
from. In rare cases the control will either
stop operating or run continuously at full
power in 120 pulse mode until the power
switch is slowly cycled OFF and ON.
Sources of Electrical Noise
Electrical noise is generated by devices
like relay coils, solenoid valves,
contactors, servo motors, and variable
frequency inverter drives. The electrical
noise is then transferred to another
device by one of three ways. The noise
could be conducted through the power
wires, or capacitively coupled from wire to
adjacent wire, or it is transmitted from the
wires of a noise source.
Solutions for Electrical Noise
1. Use shielded wires for all I/O (Input
/ Output) signals. The I/O signals may
include: 4-20mA input, Run input, Sensor
input, 0-5VDC input, Interlock input or
AUX output. The shield “drain” wire
should be tied to the chassis in the Rodix
control. The drain wire should be kept
shorter than 2”. Please see the enclosed
picture.
Example of a “drain” wire termination
2. Never run I/O signal wires in the
same conduit or raceway as AC power
lines such as wires to motors, solenoids,
heaters, welders and Rodix controls, etc.
3. I/O wires within an enclosure
should be routed as far away as possible
from relays, solenoids, transformers,
power wiring and other noisy equipment.
Keep the I/O signal wires separate from
the control’s input and output power
wiring. Secure the wires in place.
4. Whenever relays or solenoid
valves are used, install a Snubber on
them to reduce electrical noise. Use a
diode on a DC coil. Use a RC Snubber
on an AC coil.
5. In extremely high EMI
environments, Power Line Filters and
ferrite beads can be effective. Install
ferrite beads on I/O signal wires as close
as possible to the circuit board terminal
strip. Loop the wire through the bead
several times or use several beads on
each wire for additional protection.
RODIX, INC.
2316 23rd Ave. Rockford, IL 61104
Toll Free (800) 562-1868, FAX (815) 316-4701
E-mail custserv[email protected]
www.rodix.com
2000, 2003 RODIX INC. Solution 408 11/17/03
RODIX INC.
FEEDER CUBE


Plus Series
Plus SeriesPlus Series
Plus Series
RODIX SOLUTION
.408



Drain
Wire
RELAY
COILSNUBBER
VAC
104M06QC47
QUENCH-ARC
RECTIFIER
DIODE RELAY
COIL
1N4006
VDC
+
-

This manual suits for next models

2

Other Rodix Industrial Equipment manuals

Rodix FEEDER CUBE VF-9-2 User manual

Rodix

Rodix FEEDER CUBE VF-9-2 User manual

Rodix FEEDER CUBE FC-40 Plus Series Setup guide

Rodix

Rodix FEEDER CUBE FC-40 Plus Series Setup guide

Rodix FEEDER CUBE FC-90 Plus Series User manual

Rodix

Rodix FEEDER CUBE FC-90 Plus Series User manual

Rodix Plus Series User manual

Rodix

Rodix Plus Series User manual

Rodix FEEDER CUBE VF-3-2 User manual

Rodix

Rodix FEEDER CUBE VF-3-2 User manual

Rodix FEEDER CUBE VF-12 User manual

Rodix

Rodix FEEDER CUBE VF-12 User manual

Rodix FEEDER CUBE VF-9 User manual

Rodix

Rodix FEEDER CUBE VF-9 User manual

Rodix FC-40 Plus Series Setup guide

Rodix

Rodix FC-40 Plus Series Setup guide

Rodix FEEDER CUBE FC-40 Plus Series Setup guide

Rodix

Rodix FEEDER CUBE FC-40 Plus Series Setup guide

Rodix FEEDER CUBE VF-3-3 User manual

Rodix

Rodix FEEDER CUBE VF-3-3 User manual

Rodix FEEDER CUBE VF-18 User manual

Rodix

Rodix FEEDER CUBE VF-18 User manual

Rodix FEEDER CUBE CE-40 Plus Series Setup guide

Rodix

Rodix FEEDER CUBE CE-40 Plus Series Setup guide

Rodix FEEDER CUBE FC-40 Plus Series Setup guide

Rodix

Rodix FEEDER CUBE FC-40 Plus Series Setup guide

Rodix 24-210 User manual

Rodix

Rodix 24-210 User manual

Rodix FEEDER CUBE FC-41-480 Series Setup guide

Rodix

Rodix FEEDER CUBE FC-41-480 Series Setup guide

Rodix FEEDER CUBE VF-9-OR User manual

Rodix

Rodix FEEDER CUBE VF-9-OR User manual

Rodix FEEDER CUBE FC-40 Plus Series Setup guide

Rodix

Rodix FEEDER CUBE FC-40 Plus Series Setup guide

Rodix FEEDER CUBE FC-40 Plus Series Setup guide

Rodix

Rodix FEEDER CUBE FC-40 Plus Series Setup guide

Rodix FEEDER CUBE VF-393 User manual

Rodix

Rodix FEEDER CUBE VF-393 User manual

Rodix FEEDER CUBE FC-100 Plus Series Setup guide

Rodix

Rodix FEEDER CUBE FC-100 Plus Series Setup guide

Rodix FEEDER CUBE FC-40 Plus Series Setup guide

Rodix

Rodix FEEDER CUBE FC-40 Plus Series Setup guide

Rodix Autotune Series User manual

Rodix

Rodix Autotune Series User manual

Rodix FEEDER CUBE FC-40 Plus Series Setup guide

Rodix

Rodix FEEDER CUBE FC-40 Plus Series Setup guide

Rodix FEEDER CUBE FC-100 Plus Series Setup guide

Rodix

Rodix FEEDER CUBE FC-100 Plus Series Setup guide

Popular Industrial Equipment manuals by other brands

Rittal SK 3378.200 Assembly and operating instructions

Rittal

Rittal SK 3378.200 Assembly and operating instructions

ABB FDPI-02 user manual

ABB

ABB FDPI-02 user manual

McLaughlin MCL 36C Repair manual

McLaughlin

McLaughlin MCL 36C Repair manual

Ammeraal Beltech uni chains uni M-QNB Series Instructions and installation

Ammeraal Beltech

Ammeraal Beltech uni chains uni M-QNB Series Instructions and installation

ABB HT612300 Operation manual

ABB

ABB HT612300 Operation manual

Graco G3 Series instructions

Graco

Graco G3 Series instructions

Abicor Binzel MFS-V3 M-Drive operating instructions

Abicor Binzel

Abicor Binzel MFS-V3 M-Drive operating instructions

Multi-Mover 3XL 30TO User manual and parts list

Multi-Mover

Multi-Mover 3XL 30TO User manual and parts list

flexfactory flexfeeder X Series Assembly instructions

flexfactory

flexfactory flexfeeder X Series Assembly instructions

Komet JEL JSF manual

Komet

Komet JEL JSF manual

Ammeraal Beltech uni AMB Series Instructions and installation

Ammeraal Beltech

Ammeraal Beltech uni AMB Series Instructions and installation

Jäger Z62-D260.12 S2A manual

Jäger

Jäger Z62-D260.12 S2A manual

Siemens Reyrolle 7SR5 manual

Siemens

Siemens Reyrolle 7SR5 manual

Peri 019200 Instructions for use

Peri

Peri 019200 Instructions for use

Shini SAL-G Series manual

Shini

Shini SAL-G Series manual

Envirotainer RKN e1 Operation manual

Envirotainer

Envirotainer RKN e1 Operation manual

e+p Elektrik Handels HDT 300 Quick installation guide

e+p Elektrik Handels

e+p Elektrik Handels HDT 300 Quick installation guide

YoraHome 6550 user manual

YoraHome

YoraHome 6550 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.