Rotenso Dorai D10W User manual

ENG
User
manual
DORAI W
Dorai D10W
Dorai D12W

Dorai W - Dehumidier
2User manual
DORAI W DEHUMIDIFIER
User manual
Contents
SAFETY PRECAUTIONS................................................................................................................................... 3
PART 1. FUNCTIONS..................................................................................................................................... 12
Touch control panel and functions ............................................................................................................................................12
Other features ....................................................................................................................................................................................13
PART 2. OPERATING THE UNIT.................................................................................................................... 14
Identication of parts......................................................................................................................................................................14
Positioning the unit..........................................................................................................................................................................14
When using the unit ........................................................................................................................................................................15
Removing the collected water.....................................................................................................................................................16
PART 3. CARE AND MAINTENANCE............................................................................................................ 18
Care and cleaning of the dehumidier.....................................................................................................................................18
PART 4. TROUBLESHOOTING TIPS.............................................................................................................. 20
CAUTION: Risk of re/ammable material

Dorai W - Dehumidier
3
User manual
SAFETY PRECAUTIONS
Read the following if you use the device in European countries:
The device can not be operated by children over 7 years old, disabled people and oraz people without
experience and knowledge. Instructions should include a description of the correct and safe handling of the
device and oraz information about possible dangers. Children should not play with the device. Cleaning and
servicing should be carried out by authorized persons.
UTILIZATION:
Do not dispose of this product together with unsorted municipal waste.
It’s necessary to transfer this type of waste for special processing.
It’s illegal to throw the device together with other household waste.
There are several ways to get rid of this type of equipment:w
A. The city organizes electronic waste collection, you can pass the device without the cost.
B. When you buy a new device the seller will accept the old device without any fees.
C. Manufacturer will take the product from buyer produkt without charging it with costs.
D. Products of this type, contains valuable elements, it can be sold sprzedane on purchase of metals.
Throwing the device ,,on wild” exposes you to the risk of losing your health. Dangerous substances from the
device can penetrate to groundwater screating a danger of getting through to people’s food chain.
WARNING
Only qualied personnel should install and service the equipment. The installation, starting up, and
servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specic
knowledge and training. Improperly installed, adjusted or altered equipment by an unqualied person
could result in death or serious injury. When working on the equipment, observe all precautions in the
literature and on the tags, stickers, and labels that are attached to the equipment.

Dorai W - Dehumidier
4User manual
PART 1. SAFETY INFORMATION
To prevent injury to the user or other people and property damage, the following instructions must be
followed. Incorrect operation due to ignoring of instructions may cause harm or damage.
CAUTION
• Please Carefully read this operation instruction before use. Please keep it properly with your invoice
after reading.
• The company reserves the nal interpretation right of this operation instruction.
• Product appearance shall be subject to material object.
• Products shall be subject to technology or software upgrades without additional notices.
1. WARNINGS
Action with this sign should be strictly operated according to the instruction. Otherwise it
may cause damage to the product or endanger the personal security of the user.
Warning Sign
Action with this sign should be paid attention by the user. Otherwise operation error can
cause damage to the product or other losses.
Notice Sign
Never do this.
Always do this.
Do not exceed the rating of the power
outlet or connection device.
Otherwise, it may cause electric shock or
re due to excess heat generation.
Do not operate or stop the unit by
switching on or o the power supply.
It may cause electric shock or re due to
heat generation.
Do not damage or use an unspecied
power cord.
It may cause electric shock or re.
Do not modify power cord length or
share the outlet with other appliances
It may cause electric shock or re due to
heat generation.
Do not insert or pull out plug with wet
hands.
It may cause electric shock.
Do not place the unit near a heat
source.
Plastic parts may melt and cause a re.
Disconnect the power if strange sounds,
smell, or smoke comes from it.
It may cause re and electric shock.
You should never try to take apart or
repair the unit by yourself.
It may cause failure of machine or elec-
tric shock.

Dorai W - Dehumidier
5
User manual
PART 1. SAFETY INFORMATION
Before cleaning, turn o the power and
unplug the unit.
It may cause electrical shock or injury.
Do not use the machine near amma-
ble gas or combustibles, such as gaso-
line, benzene, thinner, etc.
It may cause an explosion or re.
Do not drink or use the water drained
from the unit.
It contains contaminants and could make
you sick.
Do not take the water bucket out dur-
ing operation.
It may cause bucket full protect of the
unit and cause electric shock.
2. CAUTIONS
Do not use the unit in small spaces.
Lack of ventilation can cause overheating
and re.
Do not climb up on or sit on the unit.
You may be injured if you fall or if the
unit falls over.
Care should be taken when using the
unit in a room with the following per-
sons:
Infants, children, elderly people, and peo-
ple not sensitive to humidity.
Do not use in areas where chemicals
are handled.
This will cause the unit deterioration
due to chemicals and solvents dissolved
in the air.
Do not put in places where water may splash onto the unit.
Water may enter the unit and degrade the insulation. It may cause an electric shock or re.
Never insert your nger or other foreign objects into grills or openings. Take special care to
warn children of these dangers.
It may cause electric shock or failure of appliance.
Do not place heavy object on the power
cord and take care so that the cord is not
compressed.
There is danger of re or electric shock.
Do not cover the intake or exhaust
openings with cloths or towels.
A lack of air ow can lead to overheating
and re.
Always insert the lters securely. Clean
lter once every two weeks.
Operation without lters may cause failure.
If water enters the unit, turn the unit
o and disconnect the power, contact
a qualied service technician.
It may cause failure of appliance or ac-
cident
Do not place ower vases or other water container on top of the unit.
Water may spill inside the unit, causing insulation failure and electrical shock or re.
Place the unit on a level, sturdy section of the oor.
If the unit falls over, it may cause water to spill and damage belongings, or cause electrical shock
or re.

Dorai W - Dehumidier
6User manual
PART 1. SAFETY INFORMATION
CAUTION
• This appliance can be used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a safe way and understand the hazards
involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made
by children.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualied persons in order to avoid a hazard.
• The appliance shall be installed in accordance with national wiring regulations.
• Contact the authorised service technician for repair or maintenance of this unit.
• Do not use the socket if it is loose or damaged.
• Do not operate your dehumidier in a wet room such as a bathroom or laundry room.
• Do not use this product for functions other than those described in this instruction manual.
• If the device is knocked over during use, turn o the unit and unplug it from the main power supply
immediately. Visually inspect the unit to ensure there is no damage. If you suspect the unit has been
damaged, contact a technician or customer service for assistance.
• In a thunderstorm, the power must be cut o to avoid damage to the machine due to lightning.
• To reduce the risk of re or electric shock, do not use this fan with any solid-state speed control device.
• Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do
not route cord under furniture or appliances. Arrange cord away from trac area and where it will not
be tripped over.
• Do not open the unit during operation.
• When the air lter is to be removed, do not touch the metal parts of the unit.
• Hold the plug by the head of the power plug when taking it out.
3. ELECTRICAL INFORMATION
1. The manufactures nameplate is located on the rear panel of the unit and contains electrical and other
technical data specic to this unit.
2. Be sure the unit is properly grounded. To minimize shock and re hazards, proper grounding is important.
The power cord is equipped with a three-prong grounding plug for protection against shock hazards.
3. Your unit must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not
adequately grounded or protected by a time delay fuse or circuit breaker(the fuse or circuit breaker needed
is determined by the maximum current of the unit. The maximum current is indicated on the nameplate
located on unit), have a qualied electrician install the proper receptacle.
4. Ensure the receptacle is accessible after the unit installation.
5. Do not use extension cords or an adapter plugs with this unit. However, if it is necessary to use an extension
cord, use an approved Dehumidier extension cord only (available at most local hardware stores).
6. To avoid the possibility of personal injury, always disconnect the power supply to the unit, before installing
and/or servicing.
7. All wiring must be performed strictly in accordance with the wiring diagram located on the middle bae of
the unit (behind the water bucket).

Dorai W - Dehumidier
7
User manual
PART 1. SAFETY INFORMATION
TAKE NOTE THE FUSE SPECIFICATIONS
The units circuit board (PCB) is designed with a fuse to provide overcurrent protection. The specications of the
fuse are printed on the circuit board, such as: T 3.15A/250V (or 350V), etc
NOTE: All the pictures in the manual are for explanation purposes only. The actual shape of the unit you
purchased may be slightly dierent, but the operations and functions are the same.
NOTE ABOUT FLUORINATED GASSES
1. Fluorinated greenhouse gases are contained in hermetically sealed equipment. For specic information on
the type, the amount and the CO equivalent in tonnes of the uorinated greenhouse gas(on some models),
please refer to the relevant label on the unit itself.
2. Installation, service, maintenance and repair of this unit must be performed by a certied technician.
3. Product uninstallation and recycling must be performed by a certied technician
CAUTION
• Do not use means to accelerate the defrosting process or to clean, other than those recommended by
the manufacturer.
• The appliance shall be stored in a room without continuously operating ignition sources (for example:
open ames, an operating gas appliance or an operating electric heater).
• Do not pierce or burn.
• Be aware that the refrigerants may not contain an odour.
• Appliance should be installed, operated and stored in a room with a oor area larger than 4m2.
• Compliance with national gas regulations shall be observed.
• Keep ventilation openings clear of obstruction.
• The appliance shall be stored so as to prevent mechanical damage from occurring.
• A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds
to the room area as specied for operation.
• Any person who is involved with working on or breaking into a refrigerant circuit should hold a current
valid certicate from an industry-accredited assessment authority, which authorises their competence
to handle refrigerants safely in accordance with an industry recognised assessment specication.
• Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and
repair requiring the assistance of other skilled personnel shall be carried out under the supervision of
the person competent in the use of ammable refrigerants.
CAUTION
Risk of re/ammable materials
(Required for R32/R290 units only)
IMPORTANT NOTE
Read this manual carefully before installing or
operating your new air conditioning unit. Make
sure to save this manual for future reference.

Dorai W - Dehumidier
8User manual
PART 1. SAFETY INFORMATION
Explanation of symbols displayed on the unit (for the unit adopts R32/R290 Refrigerant only):
WARNING
This symbol shows that this appliance used a ammable refrigerant. If the
refrigerant is leaked and exposed to an external ignition source, there is a
risk of re.
CAUTION This symbol shows that the operation manual should be read carefully.
CAUTION This symbol shows that a service personnel should be handling this
equipment with reference to the installation manual.
CAUTION This symbol shows that information is available such as the operating
manual or installation manual.
4. WARNINGS FOR USING R290/R32 REFRIGERANT ONLY
1. Transport of equipment containing ammable refrigerants
See transport regulations
2. Marking of equipment using signs
See local regulations
3. Disposal of equipment using ammable refrigerants
See national regulations.
4. Storage of equipment/appliances
The storage of equipment should be in accordance with the manufacturer’s instructions.
5. Storage of packed (unsold) equipment
Storage package protection should be constructed such that mechanical damage to the equipment inside
the package will not cause a leak of the refrigerant charge.
6. Information on servicing
1) Checks to the area
Prior to beginning work on systems containing ammable refrigerants, safety checks are necessary
to ensure that the risk of ignition is minimised. For repair to the refrigerating system, the following
precautions shall be complied with prior to conducting work on the system.
2) Work procedure
Work shall be undertaken under a controlled procedure so as to minimise the risk of a ammable gas or
vapour being present while the work is being performed.
3) General work area
All maintenance sta and others working in the local area shall be instructed on the nature of work being
carried out. Work in conned spaces shall be avoided. The area around the workspace shall be sectioned
o. Ensure that the conditions within the area have been made safe by control of ammable material.
4) Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure
the technician is aware of potentially ammable atmospheres. Ensure that the leak detection equipment
being used is suitable for use with ammable refrigerants, i.e. non-sparking, adequately sealed or
intrinsically safe.
5) Presence of re extinguisher
If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate re
extinguishing equipment shall be available to hand. Have a dry powder or CO2re extinguisher adjacent

Dorai W - Dehumidier
9
User manual
PART 1. SAFETY INFORMATION
to the charging area.
6) No ignition sources
No person carrying out work in relation to a refrigeration system which involves exposing any pipe work
that contains or has contained ammable refrigerant shall use any sources of ignition in such a manner
that it may lead to the risk of re or explosion. All possible ignition sources, including cigarette smoking,
should be kept suciently far away from the site of installation, repairing, removing and disposal, during
which ammable refrigerant can possibly be released to the surrounding space. Prior to work taking
place, the area around the equipment is to be surveyed to make sure that there are no ammable hazards
or ignition risks. No Smoking signs shall be displayed.
7) Ventilated area
Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or
conducting any hot work. A degree of ventilation shall continue during the period that the work is carried
out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into
the atmosphere.
8) Checks to the refrigeration equipment
Where electrical components are being changed, they shall be t for the purpose and to the correct
specication. At all times the manufacturer’s maintenance and service guidelines shall be followed. If
in doubt consult the manufacturer’s technical department for assistance. The following checks shall be
applied to installations using ammable refrigerants:
• The ventilation machinery and outlets are operating adequately and are not obstructed;
• If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of
refrigerant;
• Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be
corrected;
• Refrigeration pipe or components are installed in a position where they are unlikely to be exposed
to any substance which may corrode refrigerant containing components, unless the components are
constructed of materials which are inherently resistant to being corroded or are suitably protected
against being so corroded.
9) Checks to electrical devices
If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit
until it is satisfactorily dealt with. This shall be reported to the owner of the equipment so all parties are
advised.
Initial safety checks shall include:
That capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking;
That there no live electrical components and wiring are exposed while charging, recovering or purging the
system;
That there is continuity of earth bonding.
7. Repairs to sealed components
1) During repairs to sealed components, all electrical supplies shall be disconnected from the equipment
being worked upon prior to any removal of sealed covers, etc. If it is absolutely necessary to have an
electrical supply to equipment during servicing, then a permanently operating form of leak detection
shall be located at the most critical point to warn of a potentially hazardous situation.
2) Particular attention shall be paid to the following to ensure that by working on electrical components,
the casing is not altered in such a way that the level of protection is aected. This shall include damage to
cables, excessive number of connections, terminals not made to original specication, damage to seals,
incorrect tting of glands, etc.
3) Ensure that apparatus is mounted securely.

Dorai W - Dehumidier
10 User manual
PART 1. SAFETY INFORMATION
4) Ensure that seals or sealing materials have not degraded.
NOTE: The use of silicon sealant may inhibit the eectiveness of some types of leak detection equipment.
8. Repair to intrinsically safe components
Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not
exceed the permissible voltage and current permitted for the equipment in use. Intrinsically safe components
are the only types that can be worked on while live in the presence of a ammable atmosphere. Replace
components only with parts specied by the manufacturer. Other parts may result in the ignition of refrigerant in
the atmosphere from a leak.
9. Cabling
Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any
other adverse environmental eects. The check shall also take into account the eects of aging or continual
vibration from sources such as compressors or fans.
10. Detection of ammable refrigerants
Under no circumstances shall potential sources of ignition be used in the searching for or detection of
refrigerant leaks. A halide torch (or any other detector using a naked ame) shall not be used.
11. Leak detection methods
Electronic leak detectors shall be used to detect ammable refrigerants, but the sensitivity may not be
adequate, or may need re-calibration. (Detection equipment shall be calibrated in a refrigerant-free area.)
Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used. Leak
detection uids are suitable for use with most refrigerants but the use of detergents containing chlorine
shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe-work. If a leak
is suspected, all naked ames shall be removed/ extinguished. If a leakage of refrigerant is found which
requires brazing, all of the refrigerant shall be recovered from the system, or isolated (by means of shut o
valves) in a part of the system remote from the leak.
12. Removal and evacuation
The following procedure shall be adhered to:
• Remove refrigerant;
• Purge the circuit with inert gas;
• Evacuate;
• Purge again with inert gas;
• Open the circuit by cutting or brazing.
The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be ushed
with OFN to render the unit safe. This process may need to be repeated several times. Compressed air or
oxygen shall not be used for this task.
Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation
available.
13. Charging procedures
• Ensure that contamination of dierent refrigerants does not occur when using charging equipment.
• Hoses or lines shall be as short as possible to minimise the amount of refrigerant contained in them.
• Cylinders shall be kept upright.
• Ensure that the refrigeration system is earthed prior to charging the system with refrigerant.
• Label the system when charging is complete (if not already).
• Extreme care shall be taken not to overll the refrigeration system.
• Prior to recharging the system it shall be pressure tested with OFN.
• The system shall be leak tested on completion of charging but prior to commissioning. A follow up leak

Dorai W - Dehumidier
11
User manual
PART 1. SAFETY INFORMATION
test shall be carried out prior to leaving the site.
14. Decommissioning
It’s necessary to transfer this type of waste for special processing. It’s illegal to throw the device together with
other household waste.
15. Labelling
Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant. The label
shall be dated and signed. Ensure that there are labels on the equipment stating the equipment contains
ammable refrigerant.
16. Recovery
When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good
practice that all refrigerants are removed safely.
When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are
employed.
All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant (i.e.
special cylinders for the recovery of refrigerant). Cylinders shall be complete with pressure relief valve and
associated shut-o valves in good working order. The recovery equipment shall be in good working order
with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of
ammable refrigerants.
Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the
recovery machine, check that it is in satisfactory working order, has been properly maintained and that any
associated electrical components are sealed to prevent ignition in the event of a refrigerant release. Consult
manufacturer if in doubt.
The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and
the relevant Waste Transfer Note arranged. Do not mix refrigerants in recovery units and especially not in
cylinders. If compressors or compressor oils are to be removed, ensure that they have been evacuated to an
acceptable level to make certain that ammable refrigerant does not remain within the lubricant.

Dorai W - Dehumidier
12 User manual
PART 1. FUNCTIONS
1. DEHUMIDIFIER LED INDICATOR
Continuous dehumidifying mode light
2. INDICATOR LED
Bucket full light
3. POWER LED INDICATOR
POWER light
4. Power Pad
Press to turn the dehumidier on and o.
It illuminates when the unit is switched on and turns dark when the unit is switched o. When
Humidity/Temperature sensor malfunction occurs, the power light blinks at 5 times per second.
5. Up pad
Humidity Set Control Pads .
The humidity level can be set within a range of 35% RH (Relative Humidity) to 85% RH (Relative
Humidity) in 5% increments.
For damper air, press the pad and set a higher percent value(%).
Down pad
Humidity Set Control Pads The humidity level can be set within a range of 35% RH (Relative
Humidity) to 85% RH (Relative Humidity) in 5% increments.
For drier air, press the pad and set to a lower percent value(%).
6. Continue pad
Select for the dehumidier to operate continuously for maximum dehumidication until the
bucket is full. The Humidity set control pads cannot be used when Continuous operation is on.
Press this pad again to cancel Continuous operation and enter dehumidifying mode.
1 2 36 4
7 5
5
1. TOUCH CONTROL PANEL AND FUNCTIONS
Fig.1

Dorai W - Dehumidier
13
User manual
PART 1. FUNCTIONS
7. LED Display
Shows the set % humidity level from 35% to 85%, then shows the actual (5% accuracy) room %
humidity level in a range of 30% RH(Relative Humidity) to 90%RH(Relative Humidity).
Error Codes:
ES- Tube temperature sensor error;
AS- Room temperature sensor error;
Protection Codes:
P2- Bucket is full or bucket is not in the right position -- Empty the bucket and replace in the
right position.
NOTE: When one of the above malfunctions occurs, turn o the unit, and check for any
obstructions. Restart the unit, if the malfunction is still present, turn o the unit and unplug
the power cord. Contact the manufacturer or its service agents or a similar qualied person
for service. When reading the humidity level, please look right at the LED display window.
2. OTHER FEATURES
1. Bucket Full Light
Glows when the bucket is ready to be emptied, or when the bucket is removed or not replaced in the proper
position.
2. Auto Shut O
The dehumidier shuts o when the bucket is full, or when the bucket is removed or not replaced in the
proper position. For some models, the fan motor will continue operating for 30 seconds.
3. Wait 3 minutes before resuming operation
After the unit has stopped, it can not be restart opertation in the rst 3 minutes. This is to protect the unit.
Operation will automatically start after 3 minutes
4. Auto Defrost
When frost builds up on the evaporator coils, the compressor will cycle o and the fan will continue to run
until the frost disappears.
5. Auto-Restart
If the unit breaks o unexpectedly due to the power cut, it will restart with the previous function setting
automatically when the power resumes.

Dorai W - Dehumidier
14 User manual
PART 2. OPERATING THE UNIT
1. IDENTIFICATION OF PARTS
1
2
1. Control panel
2. Air outlet grille
3. Bucket
4. Water level window
5. Caster
6. Handale
7. Air intake grille
3
4
5
8. Air lter
(behind the grill)
9. Drain hose outlet
10.Power cord band
(used only when storing the unit)
11.Power cord
12.Power plug
6
7
8
9
10
11
12
NOTE: All the pictures in the manual are for explanation purposes only. Your unit may be slightly dierent. The
actual shape shall prevail. The operations and functions are the same.
2. POSITIONING THE UNIT
A dehumidier operating in a basement will have little or no eect in drying an adjacent enclosed storage area,
such as a closet, unless there is adequate circulation of air in and out of the area.
• Do not use outdoors.
• This dehumidier is intended for indoor residential applications only. This dehumidier should not be
used for commercial or industrial applications.
• Place the dehumidier on a smooth, level oor strong enough to support the unit with a full bucket of
water.
• Allow at least 20cm of air space on all sides of the unit for good air circulation.
• Place the unit in an area where the temperature will not fall below 5°C (41°F). The coils can become
covered with frost at temperatures below 5°C (41°F), which may reduce performance.
Fig. 2 Fig. 3

Dorai W - Dehumidier
15
User manual
PART 2. OPERATING THE UNIT
• Place the unit away from the clothes dryer, heater or radiator.
• Use the unit to prevent moisture damage anywhere books or valuables are stored.
• Use the dehumidier in a basement to help prevent moisture damage.
• The dehumidier must be operated in an enclosed area to be most eective.
• Close all doors, windows and other outside openings to the room.
Fig. 4
40 cm
or more
Air outlet grille
Air intake grille
20 cm
or more
20 cm or more
20 cm
or more
20 cm or more
NOTE
Casters (Install at four points on the bottom of unit)
• Do not force casters to move over carpet, nor move the unit with water in the bucket. (The unit may
tip over and spill water.)
NOTE: Casters is optional,
3. WHEN USING THE UNIT
• When rst using the dehumidier, operate the unit continuously 24 hours.
• This unit is designed to operate with a working environment between 5°C/41°F and 32°C/90°F, and
between 30% (RH) and 80% (RH).
• If the unit has been switched o and needs to be switched on again quickly, allow approximately three
minutes for the correct operation to resume.
• Do not connect the dehumidier to a multiple socket outlet, which is also being used for other electrical
appliances.
• Select a suitable location, making sure you have easy access to an electrical outlet.
• Plug the unit into a electrical socket-outlet with earth connection.
• Make sure the Water bucket is correctly tted otherwise the unit will not operate properly.

Dorai W - Dehumidier
16 User manual
PART 2. OPERATING THE UNIT
NOTE: When the water in the bucket reaches to a certain level,please be careful to move the machine to avoid it
falling down.
4. REMOVING THE COLLECTED WATER
1. The rst way - use the bucket
• When the bucket is full, the Full indicator light will
illuminate, the digital display shows P2.
• Slowly pull out the bucket. Grip the left and right
handles securely, and carefully pull out straight so
water does not spill. Do not put the bucket on the
oor because the bottom of the bucket is uneven.
Otherwise the bucket will fall and cause the water to
spill.
• Throw away the water and replace the bucket. The
bucket must be in place and securely seated for the
dehumidier to operate.
• The machine will restore to its original state when the
bucket is replaced in its correct position.
NOTE
• When you remove the bucket, do not touch any
parts inside of the unit. Doing so may damage the
product.
• Be sure to push the bucket gently all the way into
the unit. Banging the bucket against anything or
failing to push it in securely may cause the unit not
to operate.
• When you remove the bucket,if there is some
water in the unit you must dry it .
Fig. 5
1. Pull out the bucket a little
Water outlet
2. Hold both sides of the bucket with even
strength, and pull it out from the unit.
3. Pour the water out.
Fig. 6
Fig. 7
2. The second way - continuous draining
• Water can be automatically emptied into a oor drain by attaching the unit with a water hose (not included).
• Remove the rubber plug from the back drain hose outlet. Attach a drain hose(ID=13.5mm) and lead it to the
oor drain or a suitable drainage facility(see Fig.8 and Fig.9).
• Make sure the hose is secure so there are no leaks.
• Direct the hose toward the drain,making sure that there are no kinks that will stop the warter owing.
• Place the end of the hose into the drain and make sure the end of the hose is level or down to let the water
ow smoothly. Donever let it up.

Dorai W - Dehumidier
17
User manual
PART 2. OPERATING THE UNIT
Remove the cover
Drain hose
Fig. 8 Fig. 9
NOTE
When the continuous drain feature is not being used,remove the drain hose from the outlet and attach the
rubber plug back to the drain outlet
• Make sure the water hose is lower than the drain hose outlet.
• Select the desired humidity setting and fan speed on the unit for continuous draining to start.

Dorai W - Dehumidier
18 User manual
PART 3. CARE AND MAINTENANCE
Turn the dehumidier o and remove the plug from the wall outlet before cleaning.
1. CARE AND CLEANING OF THE DEHUMIDIFIER
1. Clean the Grille and Case.
• Use water and a mild detergent. Do not use bleach or abrasives.
• Do not splash water directly onto the main unit. Doing so may cause an electrical shock, cause the insula-
tion to deteriorate, or cause the unit to rust.
• The air intake and outlet grilles get soiled easily, so use a vacuum attachment or brush to clean.
2. Clean the bucket
• Every few weeks, clean the bucket to prevent growth of mold, mildew and bacteria. Partially ll the bucket
with clean water and add a little mild detergent. Swish it around in the bucket, empty and rinse.
3. Clean the air lter
The air lter behind the front grille should be checked and cleaned at least every two weeks or more often
if necessary.
To remove:
• Grip the tab on the lter and pull it upward, then pull it out as shown in Fig.10.
• Clean the lter with warm, soapy water. Rinse and let the lter dry before replacing it. Do not clean the
lter in a dishwasher.
To attach:
• Insert the air lter into the unit from underside to upside.
NOTE
Do not use a dishwasher to clean the bucket. After clean, the bucket must be in place and securely seated for
the dehumidier to operate.
Fig.10
NOTE
DO NOT RINSE OR PUT THE FILTER IN AN AUTOMATIC DISHWASHER

Dorai W - Dehumidier
19
User manual
PART 3. CARE AND MAINTENANCE
1. When not using the unit for long time periods
• After turning o the unit, wait one day before emptying the bucket.
• Clean the main unit, water bucket and air lter.
• Cover the unit with a plastic bag.
• Store the unit upright in a dry, well-ventilated place.
NOTE
When re-install the lter, please pat the middle buckles of the lter rst and then pat the bottom bukcle.
CAUTION
DO NOT operate the dehumidier without a lter because dirt and lint will clog it and reduce perfor-
mance.
NOTE
The cabinet and front may be dusted with an oil-free cloth or washed with a cloth dampened in a solution
of warm water and mild liquid dish washing detergent. Rinse thoroughly and wipe dry. Never use harsh
cleansers, wax or polish on the cabinet front. Be sure to wring excess water from the cloth before wiping
around the controls. Excess water in or around the controls may cause damage to the unit.

Dorai W - Dehumidier
20 User manual
PART 4. TROUBLESHOOTING TIPS
Before calling for service, review the chart below rst yourself.
Problem What to check
Unit does not start
• Make sure the dehumidier s plug is pushed completely
into the outlet.
• Check the house fuse/circuit breaker box.
• Dehumidier has reached its present level or bucket is full.
• Bucket is not in the proper position.
Dehumidier does not
dry the air as it should
• Did not allow enough time to remove the moisture.
• Make sure there are no curtains, blinds or furniture
blocking the front or back of the dehumidier.
• The humidity selector may not be set low enough.
• Check that all doors, windows and other openings are securely
closed.
• Room temperature is too low, below 5°C(41°F).
• There is a kerosene heater or something giving o water
vapor in the room.
The unit makes a loud
noise when operating
• The air lter is clogged.
• The unit is tilted instead of upright as it should be.
• The oor surface is not level.
Frost appears on the coils • This is normal. The unit has Auto defrost feature.
Water on oor
• Hose to connector or hose connection may be loose.
• Intend to use the bucket to collect water, but the back
drain plug is removed.
ES, AS or P2 appear in the
display
• These are error codes and protection codes. See the
CONTROL PADS ON THE DEHUMIDIFIER section.