RTS ADAM 2 User manual

ADAM 2
ADAM 2 FRAME 110‑220 V, ADAM 2 FRAME 110‑220 V installed,
ADAM 2 FRAME WITHOUT POWER SUPPLIES
en Technical Manual


ADAM 2 Table of contents | en 3
Bosch Security Systems, LLC Technical Manual 2020-11 | 01 | F.01U.388.223
Table of contents
1Safety 4
1.1 Copyright and Disclaimer 4
1.2 Notices 4
1.3 Important safety instructions 6
2Introduction 7
3Mounting the central matrix components 8
4ADAM 2 Reference Drawing 9
5ADAM 2 circuit cards 11
5.1 Front card access 11
5.2 Card installation and removal 11
5.3 Unused back card slots 14
5.4 Master controller card DIP switches 14
6Power supply sled removal and installation 15
7AC power connection 16
7.1 AC fuse replacement 16
8ADAM frame power-up 17
9Circuit card reset and fail indication 18
10 Alarm operation 19
11 Frame mapping (multi-frame systems only) 20
12 Intercom port connections 21
12.1 Port allocation table 21
13 KP Series keypanels 24
14 Program source notes 25
15 TIF installation notes 26
16 Device connections 27
16.1 Common cable assemblies 27
17 Configuration computer connection and check 32
18 PAP-5032 program assign panel 33
18.1 Viewing the program source for an IFB 33
18.2 Viewing IFB program source feeds 33
18.3 Key assignment from the front panel 34
19 UIO-256/GPIO-16 35
19.1 Connecting a single UIO-256/GPIO-16 36
19.2 Connecting Additional UIO-256/GPIO-16 37
19.3 Programming the UIO-256/GPIO-16 37
20 DSI-2008 38
20.1 4-wire audio connections 38
20.2 Audio connections for other 4-wire communications systems 38
20.3 4-wire call signal connections 39
20.4 Call signal connections for other 4-wire communications systems 39
21 SSA-324 40
21.1 Installation 40
21.2 Operation 42
22 Power Supply 44
22.1 Voltage Adjustment 44
22.2 Fuse Replacement 46
23 Technical data 48

4en | Safety ADAM 2
2020-11 | 01 | F.01U.388.223 Technical Manual Bosch Security Systems, LLC
1 Safety
1.1 Copyright and Disclaimer
All rights reserved. The product information and design disclosed herein were originated by
and are the property of Bosch Security Systems, LLC. Bosch reserves all patent, proprietary
design, manufacturing, reproduction, use and sales rights thereto, and to any article disclosed
therein, except to the extent rights are expressly granted to others.
No part of this document may be reproduced or transmitted in any form by any means,
electronic, mechanical, photocopying, recording, or otherwise, without the prior written
permission of the publisher. For information on getting permission for reprints and excerpts,
contact Bosch Security Systems, LLC.
All other trademarks are property of their respective owners.
The content and illustrations are subject to change without prior notice.
1.2 Notices
The lightning flash and
arrowhead within the triangle
is a warning sign alerting you
of dangerous voltage inside
the product.
Caution: To reduce the risk of
electric shock, do not remove
cover. No user-serviceable
parts inside. Refer servicing
to qualified service personnel
The exclamation point within
the triangle is a warning sign
alerting you of important
instructions accompanying
the product.
See marking on bottom/back of product.
!
Warning!
Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids,
such as vases, shall be placed on the apparatus.
!
Warning!
The main power plug must remain readily operable.
!
Caution!
To reduce the risk of electric shock, grounding of the center pin of this plug must be
maintained.

ADAM 2 Safety | en 5
Bosch Security Systems, LLC Technical Manual 2020-11 | 01 | F.01U.388.223
!
Warning!
To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
This product is AC only.
CE Compliant and UL Certified
!
Warning!
This is a CLASS A product. In a domestic environment, this product may cause radio
interference, in which case the user may be required to take adequate measures.
i
Notice!
Equipment is intended for installation in Restricted Access Area.

6en | Safety ADAM 2
2020-11 | 01 | F.01U.388.223 Technical Manual Bosch Security Systems, LLC
1.3 Important safety instructions
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with a dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer's
instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other
apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug
has two blades with one wider than the other. A grounding type plug has two blades and
a third grounding prong. The wide blade or the third prong is provided for your safety. If
the provided plug does not fit into your outlet, consult an electrician for replacement of
the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs,
convenience receptacles, and the point where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or
with the apparatus. When a cart is used, use caution when moving the cart/apparatus
combination to avoid injury from tip-over.
13. Unplug the apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the
apparatus has been damaged in any way, such as power-supply cord or plug is damaged,
liquid has been spilled or objects have fallen into the apparatus, the apparatus has been
exposed to rain or moisture, does not operate normally, or has been dropped.

ADAM 2 Introduction | en 7
Bosch Security Systems, LLC Technical Manual 2020-11 | 01 | F.01U.388.223
2 Introduction
The RTS family of Digital Intercom Matrices is the most extensive, widely used, scalable and
backwards compatible line of intercoms in the world today. The high-end ADAM 2 Matrix
supports 8 to 880 users per system; 512 ports possible in just a seven RU (Rack Units) frame.
Utilizing a patented TDM (Time Division Multiplex) technique, the ADAM 2 grows linearly as
users are added. The system comes standard with redundant universal power supplies
(100-240 VAC), and supports redundant controllers, allowing for automatic change-over in the
event of failure.
ADAM 2 is available with a wide variety of Interface cards in the industry, including the
MADI-16, OMI, AIO-16A, and RVON + interfaces. It also has the wide variety of cabling options,
including RJ11, RJ45, DB9, jack fields, and many others.
With its second generation controller card, Ethernet connectivity is achieved between the
ADAM 2 Intercom and AZedit. ADAM 2 can support 32 simultaneous AZedit sessions.
Features
– Supports all standards including VoIP, OMNEO, DANTE, Analog, SMPTE 2110, MADI, and
more depending on cards populated in the frame.
– The new ADAM 2 is designed with quieter fans, universal power supplies that operate in
all countries and is compatible with ALL current and legacy RTS keypanels and
accessories. It comes standard with multi-level IFB, ISO, Party-Lines, Groups, and GPIs. It
supports from 8 to 880 users.
– Supports real-time monitoring online and offline configuration and RTS UPL (User
Programmable Language) for custom system configurations via pull-down menus.
– In addition to digital and VoIP cards, the analog dual-purpose ports support both
keypanel and 4-wire audio.
– Integrated support for RTS Intelligent Trunking of 255 matrices (ADAM, ADAM-CS, ADAM-
M, ADAM 2, Cronus, Zeus III, and ODIN).
Unpacking the components
– Unpack the contents of the shipping crates and carefully inspect for damage.
– Notify the freight carrier immediately if any damage is noted.
– Check off all items as noted in the packing lists.
!
Caution!
Use caution when lifting the system components.
A fully loaded ADAM 2 card frame weighs approximately 75 lbs (34 kg).

8en | Mounting the central matrix components ADAM 2
2020-11 | 01 | F.01U.388.223 Technical Manual Bosch Security Systems, LLC
3 Mounting the central matrix components
Bolt the frame into the front of the equipment rack. Make sure the ventilation holes on the
front and back are unobstructed. The rack space behind the frame should be completely clear
to allow for connections and card installation and removal (at least two feet).
i
Notice!
There is an LED fail indicator and reset switch located near the top-front of each front card.
The LED indicators are only visible when the center of the card frame is at or above eye level.
Considerations
– Mount station breakout panels and translation panels in the back of the equipment rack
to allow intercom station cabling to exit the frame at the top and bottom of the unit, as
required.
– Mount optional UIO-256/GPIO-16 frames in the front of an equipment rack. Position a
UIO-256/GPIO-16 to give visibility of the front panel LEDS, which provide visual indication
for any active inputs and outputs.
– Mount PAPs (program assign panels) in the front of an equipment rack. To allow for
viewing of the front panel indicators and easy activation of the front panel controls,
position the PAP slightly below eye level when sitting or standing.

ADAM 2 ADAM 2 Reference Drawing | en 9
Bosch Security Systems, LLC Technical Manual 2020-11 | 01 | F.01U.388.223
4 ADAM 2 Reference Drawing
11
223 3
4
5
6
7
8
8
9
9 10
10

10 en | ADAM 2 Reference Drawing ADAM 2
2020-11 | 01 | F.01U.388.223 Technical Manual Bosch Security Systems, LLC
1. Power supply rail LED indicators
2. Power supply sled
3. Power supply sled power switch
4. Thumb screw (x 3)
5. Chassis Handle (x 2)
6. Alarm Override switch
7. Card slots
8. AC power connector
9. AC Fuse
10. ADAM 2 power switch

ADAM 2 ADAM 2 circuit cards | en 11
Bosch Security Systems, LLC Technical Manual 2020-11 | 01 | F.01U.388.223
5 ADAM 2 circuit cards
5.1 Front card access
To access the front cards, do the following:
1. Loosen the thumb screws securing the front glass door.
2. Swing the door down.
5.2 Card installation and removal
It is not necessary to turn off the power to the ADAM 2 frame before installing or removing
cards in the frame. This permits continuous operation of the intercom system with no
interruptions to unaffected ports in the event of a card failure.
Removal of a front or back audio card from the frame causes asterisks to appear on any
keypanel connected to the card. When the card is reinserted into the frame, it takes a few
minutes for the keypanel display to return to normal.
The card in slot 9 determines all system clock functions. The card in slot 8 serves as a backup
to the card in slot 9.
!
Caution!
Never remove cards in slot 8 and 9 at the same time.
This causes the intercom system to stop working.
i
Notice!
Read all instructions before installation.
Damage to connector pins located on the back plane inside the ADAM 2 frame can occur by
improper or hurried insertion of the circuit cards.

12 en | ADAM 2 circuit cards ADAM 2
2020-11 | 01 | F.01U.388.223 Technical Manual Bosch Security Systems, LLC
Figure5.1: Back card installation
To insert back cards, do the following:
1. Orient the card so the side connector edge is toward the bottom.
2. Insert the card edges into the upper and lower guides in the back of the ADAM 2 frame.
3. Push the card in until the mounting plate is flush with the ADAM 2 frame.
4. Install mounting screws (M2.5 x 10 mm) in the top and bottom of the card plate to lock
it in place.

ADAM 2 ADAM 2 circuit cards | en 13
Bosch Security Systems, LLC Technical Manual 2020-11 | 01 | F.01U.388.223
Figure5.2: Front card installation
To insert front cards, do the following:
i
Notice!
Orient the front card so that the indicator LED and reset switch are at the top front.
1. Insert the card edges into the upper and lower card guides in the front of the ADAM 2
frame.
2. Push the card straight into the slot until you feel an initial resistance.
3. Apply slightly more pressure to engage the connector pins.
4. Press firmly to completely seat the connectors.
The card mounting plate should be flush with the ADAM 2 frame.
i
Notice!
For mobile installations, use mounting screws (M2.5 x 10 mm) to secure the front cards.

14 en | ADAM 2 circuit cards ADAM 2
2020-11 | 01 | F.01U.388.223 Technical Manual Bosch Security Systems, LLC
To remove the front card, do the following:
1. Unscrew the top and bottom screws, if installed.
2. Simultaneously press down on the lower ejector lever and press up on the upper ejector
lever.
3. Pull the front card straight out of the frame.
To remove a back card, do the following:
1. Unscrew the top and bottom screws on the back card.
The screws do not completely come out.
2. Simultaneously press down on the lower ejector lever and press up on the upper ejector
lever.
3. Remove the back card from the frame.
5.3 Unused back card slots
Use a card blank to cover the opening when there are unused back card slots to ensure proper
air flow.
5.4 Master controller card DIP switches
All master controller card DIP switches are set to the factory default operation position. These
settings are satisfactory for most applications. Optional settings are summarized in table
below. Be sure the main and backup controller cards are set the same if changes are made to
these settings.
DIP Switch 1 Debug Only! Must be in the OPEN position.
DIP Switch 2 Sets the baud rate for AZedit serial connection via J1.
By default, AZedit is set for COM1 and 38,400 kbps (38.4k). The
baud rate set in AZedit must match the baud rate setting of the
Master Controllers in the frame.
Default: Closed
Open: 9,600 baud
Closed: 38.4k baud
DIP Switch 3, 4, and 5 Reserved, keep in the OPEN position.
DIP Switch 6 Debug Only! Must be in the OPEN position.
DIP Switch 7 Determines the Master/Slave frame in a multi-frame system.
Default: Closed
Open: Slave Frame
Closed: Master Frame
DIP Switch 8 Debug Only! Must be in the OPEN position
Tab.5.1: MCII-e Factory set DIP Switch Settings
!
Caution!
DIP switches 1, 6, and 8 should always be left in the OPEN position. These are reserved for
debugging and can have unintended consequences if not left in the OPEN position.

ADAM 2 Power supply sled removal and installation | en 15
Bosch Security Systems, LLC Technical Manual 2020-11 | 01 | F.01U.388.223
6 Power supply sled removal and installation
To remove the power supply sled, do the following:
1. Turn the power supply sled power switch off.
i
Notice!
The power supply sleds can be removed while power is applied, it is recommended to turn
the power supply sled off for the sled to be removed.
2. Loosen the two captive thumb screws on the front of the power sled.
3. Grasp the handle.
4. Pull the power supply sled from the frame.
To install the power supply sled, do the following:
1. Push the power supply sled firmly into the designated slot in the ADAM 2 frame.
2. Tighten the captive thumb screws.
3. Turn the power supply sled power switch on.

16 en | AC power connection ADAM 2
2020-11 | 01 | F.01U.388.223 Technical Manual Bosch Security Systems, LLC
7 AC power connection
To connect power to the ADAM 2 frame, do the following:
1. Place the ADAM 2 power switches on the back panel to the off position.
2. Place the power supply power switch on the front of each power supply sled to the off
position.
3. Attach a power cable to each AC power connector on the back of the ADAM 2 frame.
i
Notice!
Connecting both AC inputs insures continued operation of the ADAM 2 frame in the event that
one power supply fails. If desired, connect two separate AC power phases. This protects
against a power supply failure and against a loss of power to one phase.
7.1 AC fuse replacement
To replace the AC fuse, do the following:
1. Place the ADAM 2 power switches on the back panel to the off position.
2. Place the power supply power switch on the front of each power supply to the off
position.
3. Remove both power cables from the AC power connectors on the back of the ADAM 2
frame.
4. Using a flat head screwdriver, turn the AC fuse cap to remove the fuse.
The cap is spring-loaded and pops out when the fuse cap is loosened.
5. Remove the old AC fuse from the fuse cap.
6. Insert the new AC fuse in the fuse cap.
i
Notice!
Required fuse:
Eaton Bussmann S500-10-R
5 x 20 mm 10 Amp 250 VAC fast blow
7. Using the flat head screwdriver, push and turn the AC fuse cap to secure it in place.

ADAM 2 ADAM frame power-up | en 17
Bosch Security Systems, LLC Technical Manual 2020-11 | 01 | F.01U.388.223
8 ADAM frame power-up
i
Notice!
Install at least two front cards in the frame before turning on the power to ensure proper
power supply loading.
To power on the ADAM 2 frame, do the following:
1. Place the ADAM 2 power switches in the on position.
i
Notice!
The ADAM 2 power switch in the on position illuminates the power supply sled power switch
LED.
2. Place the alarm override switch in the on position.
3. Place the power supply sled power switch in the on position.
The four power supply rail LED indicators on the power sled front light, the fans start,
and the alarm shuts off.
i
Notice!
The red LED fail indicators light on all circuit cards while the intercom system initializes.
Allow 15 to 30 seconds for all indicators to turn off. If the red LED fail indicators do not turn
off, use AZedit to configure the card slot properly.

18 en | Circuit card reset and fail indication ADAM 2
2020-11 | 01 | F.01U.388.223 Technical Manual Bosch Security Systems, LLC
9 Circuit card reset and fail indication
Each front card has a reset button located near the top of the card. Directly under the reset
button is a red LED fail indicator. The LED indicator remains off during normal operation. If
the LED fail indicator turns on, first attempt to resort normal operation by momentarily
pressing the reset button. Allow 15 to 30 seconds for reset. If the LED fail indicator does not
turn off after this time, replace the affected card.
Figure9.1: Reset Switch

ADAM 2 Alarm operation | en 19
Bosch Security Systems, LLC Technical Manual 2020-11 | 01 | F.01U.388.223
10 Alarm operation
If there is a power supply sled fault during operation, the audible alarm sounds and one or
more power rail LED indicator lights on the affected power sled turn off.
To deactivate the alarm, do the following:
1. Set the alarm override switch to the off position.
2. Turn off the defective power supply sled.
3. Repair or replace the power supply sled.
For information on replacing the power supply sled, refer to
Power supply sled removal and
installation, page 15
.
i
Notice!
The alarm also sounds if a power sled is off and the alarm override switch is on. Either turn
on the power supply sled or turn off the alarm override switch.

20 en | Frame mapping (multi-frame systems only) ADAM 2
2020-11 | 01 | F.01U.388.223 Technical Manual Bosch Security Systems, LLC
11 Frame mapping (multi-frame systems only)
Frame Mapping is used to assign the position of each frame in a multi-frame system intercom
system. The frame order determines the port range assigned. For example, when mapping a 2-
frame system, with each frame having 128 ports, the first frame is given ports 1 through 128.
The second frame is assigned ports 129 through 256.
To order the frames in a system, a frame mapping table must be configured.
To map frames from AZedit, do the following:
1. From the Options menu, select Frame Mapping.
The Frame Mapping Table appears.
2. Click the Browse icon to select a frame to add to the table.
The Select Frame screen appears.
3. Select the IP address of the desired frame.
4. Click the OK button.
The Select Frame screen closes and the frame information is added to the frame mapping
table.
5. Repeat steps 3 and 4, as necessary.
6. Click the Test button to validate the table.
A valid or not valid message appears.
7. Click OK.
The message closes.
8. Click Apply.
The modifications are applied to the frame mapping table.
9. Click Done.
The Frame Mapping Table closes.
Table of contents